Catalogue 1654741 Product Facts Available circuit configurat


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



.140 MATE-N-LOK Connectors, Large Insulation
Catalogue 1654741
Product Facts
Available circuit configurations panel mounting; circuit configurations free hanging applications Standard natural nylon housings Housings fully polarised Contacts fully protected housings Contacts accept wire size range 20-10 [.55.0 mm2] with insulation diameters from .100 [2.54] .180 [4.57] insertion/extraction forces Dual locking lances promote optimum contact stability Extraction tool removes both pins sockets Contacts .240 [6.09] centerline spacing interrupting current Recognised under Component Program Underwriters Laboratories Inc., File E28476
Certified Canadian Standards Association, File 7189A
Performance Characteristics:
.140 MATE-N-LOK Connector performance characteristics found this page based free hanging panel mount connectors, loaded with contacts crimped stranded wire. Dielectric Withstand Voltage KVAC between adjacent circuits Insulation Resistance 1000 megohms minimum initial between adjacent circuits Voltage Rating 250V Connector Mating max. circuit Connector Unmating min. circuit Contact Retention min. Durability cycles, mating unmating Thermal Shock 55°C 85°C Temperature-Humidity Cycling 25°C 65°C
Maximum Current Maximum current rating .140 MATE-N-LOK connectors limited maximum operating temperature housings which 105°C temperature rise contacts which 30°C. There several variables which have direct effect this maximum current-carrying capability given connector must considered each application. These variables are: Wire Size Larger diameter wire will carry more current since less internal resistance current flow thus generates less heat. Longer wire lengths also enhance current carrying capabilities since wire conducts heat away from connector. Connector Size general, more circuits connector, less current carried. Ambient Temperature higher ambient temperature, less current carried given connector.
Wire Size
Termination Resistance Test Resistance Current Milliohms (Amps) (Max. Init.)
Contact Crimp Tensile Force Force (Min.) lbs.
Note: This total resistance between wire crimps mated socket.
Current Rating Verification Maximum Temperature Rise 100% Energised Wire-to-Wire .140 Calculated Current Table
Number Circuits 28.00 25.00 18.50 23.00 21.00 15.00 Wire 18.50 15.00 17.00 13.50 12.00 10.00 13.50 12.00 9.00 10.50 9.50 7.00
Technical Documents:
Product Specification 108-1032 .140 Diameter MATE-N-LOK Connectors Application Specification 114-1007 .140 Diameter MATE-N-LOK Contacts
Values based initial Temperature Rise versus Current Testing intended guide selection connector family. applications should tested user. values listed circuit fully loaded housings being 100% energised. Note: combinations were tested, this chart contains interpolated extrapolated values.
Minimum Wire Lengths T-Rise Current Testing page 9049
Note: wire lengths used less than those listed, current carrying ability system will reduced less heat being conducted away from connector. customer should fully test applications.
9048
Products Industrial Commercial Applications Dimensions shown reference purposes only. Conversion Rate: 25.4mm inch Dimensions inches millimetres unless otherwise specified. Values brackets metric equivalents. Specifications subject change. www.tycoelectronics.com
very latest product data news visit anglia.com
.140 MATE-N-LOK Connectors, Large Insulation
Contacts
Product Specifications:
diameter-.140 [3.57] Stock thickness-.014 [.357]
.995 [25.27] .795 [20.19]
Catalogue 1654741
Socket Connectors
Related Product Data:
Performance Characteristics page 9048 Keying Plug none Housings pages 9049-9050 Application Tooling pages 9120, 9121 9123
Wire Size Ins. Dia. Range [mm2] Range 20-14 .100-.180 [.5-2.0] 2.54-4.5 Socket
Technical Documents: pages 9048
9119 Product Specification 108-1032 .140 Diameter MATE-N-LOK Connectors Application Specification 114-1007 .140 Diameter MATE-N-LOK Contacts
14-10 .100-.180 [2.0-5.0] 2.54-4.5
Contact Part Numbers Hand Tool Socket Applicator Part Numbers Part Numbers Strip Form Loose Form Strip Form Loose Form 567306-1 Brass. pre-tin 61627-1 350389-1 61626-1 350388-1 567306-2 90247-1 Phos. Brz., pre-tin 61627-2 61626-2 567306-3 567309-1 Brass. pre-tin 350201-1 350391-1 350200-1 350390-1 567309-2 69710-12 Phos. Brz., pre-tin 350201-2 350391-2 350200-2 350390-2 567309-3 Material Finish
Applicator part number ending used AMPOMATOR Machine with Terminators, used AMP-O-LECTRIC Model Machine, used AMP-O-LECTRIC Model Machine. page 9123 further information. Hand Tool 69710-1 uses 58374-1 14-12 58373-1 AWG. Contact Extraction Tool Part Number 453300-1 408-9569
Housings, Free Hanging
Product Specification:
Centerline spacing-.240 [6.09]
Circuit
1.130 [28.70] 1.065 [27.05] 1.180 [29.97]
Material:
Nylon, natural colour Flammability Rating UL94V-2 Cavity Identification (Rear View)
.565 [14.35] .240 [6.09] .865 [21.97] .240 [6.09] .580 [14.73] .950 [24.13] 1.350 [34.29]
.775 [19.68]
Housing (Cap) Part Number 1-480512-0 Part Number 794700-1 (Black Colour)
Socket Housing (Plug) Part Number 1-480510-0
Circuit, Matrix
Plug
1.130 [28.70] .845 [21.46] .240 [6.09] .755 [19.17] .950 [24.13]
.755 [19.17]
.845 [21.46]
.755 [19.17]
Housing (Cap) Part Number 1-480586-0
.240 [6.09]
Socket Housing (Plug) Part Number 1-480585-0
Plug
9049
Products Industrial Commercial Applications Dimensions shown reference purposes only. Conversion Rate: 25.4mm inch Dimensions inches millimetres unless otherwise specified. Values brackets metric equivalents. Specifications subject change. www.tycoelectronics.com
very latest product data news visit anglia.com
.140 MATE-N-LOK Connectors, Large Insulation
Housings, Panel Mount
Product Specification:
Centerline spacing-.240 [6.09]
Catalogue 1654741
Circuit, In-Line
.240 [6.09] .515 [13.08] .815 [20.70] .965 [24.51] .515 [13.08]
Material:
Housing Nylon, natural colour Flammability Rating UL94V-2 Cavity Identification (Rear View)
.950 [24.13]
.275 [6.98]
.365 [9.27]
1.130 [28.70]
Socket Housing (Plug) Part Number 1-350344-0 Part Number 794699-1 (Black Colour)
.240 [6.09]
Housing (Cap) Part Number 1-350345-0
Plug
.755 [19.17] 1.055 [26.79] 1.205 [26.79] .755 [19.17]
.950 [24.13]
.275 [6.98]
.365 [9.27]
1.130 [28.70]
Socket Housing (Plug) Part Number 1-350346-0
Housing (Cap) Part Number 1-350347-0 Part Number 794061-1 (Black Colour)
Plug
Circuit, Matrix
.240 [6.09] .755 [19.17] .950 [24.13] 1.130 [28.70] .910 [23.11] .240 [6.09] .755 [19.17] .950 [24.13] .910 [23.11]
Plug
.240 [6.09]
.240 [6.09]
Socket Housing (Plug) Part Number 1-480672-0
Housing (Cap) Part Number 1-480673-0 Part Number 794683-1 (Black Colour)
Recommended Panel Cutouts
View from housing entry side
Circuit
.0502 [1.27]
Circuit
1.025 [26.03] .765 [19.43]
Related Product Data:
Performance Characteristics page 9048 Keying Plug none Contacts page 9049
.475 [12.06] .050 [1.27]
.288 [7.31]
.190 [4.82]
Notes: Panel thickness .040-.070 [1.02-1.78]. dimensions must within .005 [.127] each other. Panel should punched that housing enters panel same direction punch ease assembly.
Technical Documents: pages 9048
9119 Product Specification 108-1032 .140 Diameter MATE-N-LOK Connectors Application Specification 114-1007 .140 Diameter MATE-N-LOK Contacts
Circuit-.725 [18.42] Circuit- .965 [24.51] .050 .050 [1.27-1.27] tabs corners outlet optional reduce housing float panel.
1.025 .765 [19.43] [26.03]
.190 [4.82]
9050
Products Industrial Commercial Applications Dimensions shown reference purposes only. Conversion Rate: 25.4mm inch Dimensions inches millimetres unless otherwise specified. Values brackets metric equivalents. Specifications subject change. www.tycoelectronics.com
very latest product data news visit anglia.com

Other recent searches


XTL1027 - XTL1027   XTL1027 Datasheet
Si5515DC - Si5515DC   Si5515DC Datasheet
SF-BF-10 - SF-BF-10   SF-BF-10 Datasheet
S2K1 - S2K1   S2K1 Datasheet
PG191 - PG191   PG191 Datasheet
PK025 - PK025   PK025 Datasheet
MC68HC08AB16A - MC68HC08AB16A   MC68HC08AB16A Datasheet
GCQ20A04 - GCQ20A04   GCQ20A04 Datasheet
CN8478 - CN8478   CN8478 Datasheet
CN8474A - CN8474A   CN8474A Datasheet
CN8472A - CN8472A   CN8472A Datasheet
CN8471A - CN8471A   CN8471A Datasheet
2SB1510 - 2SB1510   2SB1510 Datasheet
2SD2284 - 2SD2284   2SD2284 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive