Capacitors, Switch

Download

PDF Abstract Text:

Chassis-mounting filter with feedthrough options


· · · · 10 to 40A current ratings X1 capacitors for extra immunity to high voltage transients performance maintained at high frequencies additional X capacitor option for higher differential-mode attenuation

Chassis-mounting filter with feedthrough options
· · · · 10 to 40A current ratings X1 capacitors for extra immunity to high voltage transients performance maintained at high frequencies additional X capacitor option for higher differential-mode attenuation
FN 2110 / FN 2120
Technical specifications
Maximum operating voltage: 250VAC at 40°C Maximum operating frequency: DC to 400Hz at 40°C Hipot test voltage: PNE 2000VAC PN 1100VDC MTBF at 40°C, 230V per Mil-HB-217F: FN 2110 1, 228, 000 hours FN 2120 903, 000 hours Overload: 4 times rated current at switch on, then 1.5 times rated current for 1 minute, once per hour Temperature range: -25°C to +85°C Flammability class: UL 94V0
Approvals
EN 133200
Filter
Current ratings
Leakage current
(230V / 50Hz) mA / phase 0.4 0.4 0.86 0.86 0.4 0.4 0.86 0.86
Power loss max.
Component values
Connections
Weight
W 2.4 4.0 5.4 9.6 2.4 4.0 5.4 9.6
L mH 0.8 0.6 0.67 0.5 0.8 0.6 0.67 0.5
Cx µF 0.22 0.22 0.47 0.47 0.22 0.22 0.47 0.47
Cy nF 4.7 4.7 10 10 4.7 4.7 10 10
g 150 260 470 700 150 260 470 700
Note: / 07 connection only on load side.
Electrical schematics
FN 2110 / FN 2120 insertion loss
dB 70 60 50 40 30 A 20 10 0 - 10 -20 10k 100k 1M 10M 100M 1G B A
50 / 50 sym.
dB 70 60 B 50 40 30 20 A 10 0 -10 -20 10k 100k 1M 10M 100M 1G
50 / 50 sym.
Mechanical data 10A versions
/ 06 connection
/ 07 connection
20A versions
/ 06 connection
/ 07 connection
/ 08 connection
Mechanical data
30A versions
/ 07 connection
/ 08 connection
40A versions
/ 07 connection
/ 08 connection