Pressure transmitters oxygen applications ENGINEERING PROPOSAL


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



OxyProof Series
Pressure transmitters oxygen applications
ENGINEERING PROPOSAL
FEATURES safety approval oxygen applications11 0.-1 0.350 bar, gage absolute 0.10 0.5.4.5 4.20 output Field interchangeable
MEDIA COMPATIBILITY
Pressure inlet: media compatible with stainless steel 1.4404 (316L), ceramic Al2O3 Housing: stainless steel, protection class IP65 according DIN400501
SPECIFICATIONS9,10
Maximum ratings
ELECTRICAL CONNECTION
0.10 0.5.4.5 output
Supply voltage (reverse polarity protection) 0.10 output 12.30 0.5.4.5 output 9.30 4.20 output2 9.30 Maximum load current (source) voltage outputs Temperature limits Storage Operating Compensated Humidity limits Vibration Mechanical shock Proof pressure3
Vout
sensor
gRMS rated pressure
4.20 output
sensor
March 2008
www.sensortechnics.com
OxyProof Series
Pressure transmitters oxygen applications
ENGINEERING PROPOSAL
COMMON PERFORMANCE CHARACTERISTICS
tamb 25°C
Characteristics
Operating pressures
Min.
Typ.
Max.
0.05 0.05
Unit
Thermal effects °C)4 Thermal effects (-40 Non-linearity, hysteresis (BSL) repeatability5 Long term stability6 Output noise kHz) Response time Power supply rejection
Offset Span Offset Span others
0.02 0.02 0.03 0.03 ±0.20 ±0.15 ±0.3 ±0.04
%FSO/°C
±0.40 ±0.25 %FSO
Offset Span
voltage output current output voltage output current output
0.002 0.05 0.002 0.08
%FSO/V
March 2008
www.sensortechnics.com
OxyProof Series
Pressure transmitters oxygen applications
ENGINEERING PROPOSAL
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0.10 output tamb 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption load) 0.±1 devices others 0.±1 devices others
Min.
Typ.
0.03
Max.
10.1
Unit
0.5.4.5 output tamb 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption load) 0.±1 devices others 0.±1 devices others
Min.
2.450 0.450 1.950 3.950
Typ.
Max.
2.550 0.550 2.050 4.050
Unit
output tamb 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption load)
4.20 output tamb 25°C)
Min.
2.45 2.45 4.95
Typ.
0.03
Max.
2.55 0.08 2.55 5.05
Unit
0.±1 devices others 0.±1 devices others
Characteristics
Zero pressure offset Full scale span7 Power consumption 0.±1 devices others 0.±1 devices others
Min.
11.9 15.9
Typ.
12.0 16.0
Max.
12.1 16.1
Unit
March 2008
www.sensortechnics.com
OxyProof Series
Pressure transmitters oxygen applications
ENGINEERING PROPOSAL
ELECTROMAGNETIC CAPABILITY8
Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) EN61000-4-3: Grade V/m, 1000 kHz) Criterion Interference %FSO %FSO %FSO %FSO
Electrical fast transient burst immunity (EFT) EN61000-4-4: Grade Electrostatic discharge immunity test (ESD) Immunity conducted disturbances induced radio-frequency fields EN61000-4-2: Grade contact discharge EN61000-4-6: Grade 0.15 kHz)
LOAD LIMITATION
4.20 output version
1400 1200 1000
ratin
RECOMMENDED PLUG (DIN 43650-A)
Plug profile washer included delivery!
supply voltage
dimensions
Specification notes (for devices):
package all-sealed housing. IP65 protection given when connector locked with rubber washer. proper function gage port vented atmosphere through connector/cable assembly. Thus cable must have access ambient pressure. minimum supply voltage directly proportional load resistance seen transmitter. more details load limitation diagram. Proof pressure maximum pressure which applied without causing damage sensing element. Thermal effects tested guaranteed from 60°C relative 25°C. specifications shown relative 25°C. Non-linearity refers Best Straight Line measured offset, full scale span full scale span. Long term stability change output after year million pressure cycles. Span arithmetic difference transmitter output signal measured zero pressure maximum operating pressure. Test accordance with EN61000-6-2, April 1999. CE-labelling accordance with 89/336/EEC. pressure transmitters must used safety accessories according article 2.1.3 directive 97/23/EC. certification-No: BAM/ZBA/001/07. certificate refers only burn-out safety materials oxygen service.
March 2008
www.sensortechnics.com
OxyProof Series
Pressure transmitters oxygen applications
ENGINEERING PROPOSAL
OUTLINE DRAWING
Electrical termination: 43650-A Pressure connection: 1/4" (1/4" BSP)
(0.18) (1.06)
(0.47)
(2.86) (0.33) (0.47)
vent hole
G1/4" (1/4" BSP)
27.0 (1.06) diam.
mass:
dimensions (inches)
Note: Other pressure ranges, output signals, electrical terminations pressure connections available request. Minimum order quantity apply. Please contact your nearest Sensortechnics sales office further information.
Sensortechnics reserves right make changes products herein. Sensortechnics does assume liability arising application product circuit described herein, neither does convey license under patent rights rights others.
March 2008
www.sensortechnics.com

Other recent searches


YG975C6R - YG975C6R   YG975C6R Datasheet
uPA1742TP - uPA1742TP   uPA1742TP Datasheet
SP5668 - SP5668   SP5668 Datasheet
DS4538 - DS4538   DS4538 Datasheet
SML-311 - SML-311   SML-311 Datasheet
NJM2277 - NJM2277   NJM2277 Datasheet
NJM2277G - NJM2277G   NJM2277G Datasheet
NJM2277M - NJM2277M   NJM2277M Datasheet
MSM6568A - MSM6568A   MSM6568A Datasheet
2N3507L - 2N3507L   2N3507L Datasheet
2N3507LJ - 2N3507LJ   2N3507LJ Datasheet
2N3507LJX - 2N3507LJX   2N3507LJX Datasheet
2N3507LJV - 2N3507LJV   2N3507LJV Datasheet
2N3507LJS - 2N3507LJS   2N3507LJS Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive