| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Pressure transmitters oxygen applications ENGINEERING PROPOSAL
Top Searches for this datasheetOxyProof Series Pressure transmitters oxygen applications ENGINEERING PROPOSAL FEATURES safety approval oxygen applications11 0.-1 0.350 bar, gage absolute 0.10 0.5.4.5 4.20 output Field interchangeable MEDIA COMPATIBILITY Pressure inlet: media compatible with stainless steel 1.4404 (316L), ceramic Al2O3 Housing: stainless steel, protection class IP65 according DIN400501 SPECIFICATIONS9,10 Maximum ratings ELECTRICAL CONNECTION 0.10 0.5.4.5 output Supply voltage (reverse polarity protection) 0.10 output 12.30 0.5.4.5 output 9.30 4.20 output2 9.30 Maximum load current (source) voltage outputs Temperature limits Storage Operating Compensated Humidity limits Vibration Mechanical shock Proof pressure3 Vout sensor gRMS rated pressure 4.20 output sensor March 2008 www.sensortechnics.com OxyProof Series Pressure transmitters oxygen applications ENGINEERING PROPOSAL COMMON PERFORMANCE CHARACTERISTICS tamb 25°C Characteristics Operating pressures Min. Typ. Max. 0.05 0.05 Unit Thermal effects °C)4 Thermal effects (-40 Non-linearity, hysteresis (BSL) repeatability5 Long term stability6 Output noise kHz) Response time Power supply rejection Offset Span Offset Span others 0.02 0.02 0.03 0.03 ±0.20 ±0.15 ±0.3 ±0.04 %FSO/°C ±0.40 ±0.25 %FSO Offset Span voltage output current output voltage output current output 0.002 0.05 0.002 0.08 %FSO/V March 2008 www.sensortechnics.com OxyProof Series Pressure transmitters oxygen applications ENGINEERING PROPOSAL INDIVIDUAL PERFORMANCE CHARACTERISTICS 0.10 output tamb 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption load) 0.±1 devices others 0.±1 devices others Min. Typ. 0.03 Max. 10.1 Unit 0.5.4.5 output tamb 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption load) 0.±1 devices others 0.±1 devices others Min. 2.450 0.450 1.950 3.950 Typ. Max. 2.550 0.550 2.050 4.050 Unit output tamb 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption load) 4.20 output tamb 25°C) Min. 2.45 2.45 4.95 Typ. 0.03 Max. 2.55 0.08 2.55 5.05 Unit 0.±1 devices others 0.±1 devices others Characteristics Zero pressure offset Full scale span7 Power consumption 0.±1 devices others 0.±1 devices others Min. 11.9 15.9 Typ. 12.0 16.0 Max. 12.1 16.1 Unit March 2008 www.sensortechnics.com OxyProof Series Pressure transmitters oxygen applications ENGINEERING PROPOSAL ELECTROMAGNETIC CAPABILITY8 Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) EN61000-4-3: Grade V/m, 1000 kHz) Criterion Interference %FSO %FSO %FSO %FSO Electrical fast transient burst immunity (EFT) EN61000-4-4: Grade Electrostatic discharge immunity test (ESD) Immunity conducted disturbances induced radio-frequency fields EN61000-4-2: Grade contact discharge EN61000-4-6: Grade 0.15 kHz) LOAD LIMITATION 4.20 output version 1400 1200 1000 ratin RECOMMENDED PLUG (DIN 43650-A) Plug profile washer included delivery! supply voltage dimensions Specification notes (for devices): package all-sealed housing. IP65 protection given when connector locked with rubber washer. proper function gage port vented atmosphere through connector/cable assembly. Thus cable must have access ambient pressure. minimum supply voltage directly proportional load resistance seen transmitter. more details load limitation diagram. Proof pressure maximum pressure which applied without causing damage sensing element. Thermal effects tested guaranteed from 60°C relative 25°C. specifications shown relative 25°C. Non-linearity refers Best Straight Line measured offset, full scale span full scale span. Long term stability change output after year million pressure cycles. Span arithmetic difference transmitter output signal measured zero pressure maximum operating pressure. Test accordance with EN61000-6-2, April 1999. CE-labelling accordance with 89/336/EEC. pressure transmitters must used safety accessories according article 2.1.3 directive 97/23/EC. certification-No: BAM/ZBA/001/07. certificate refers only burn-out safety materials oxygen service. March 2008 www.sensortechnics.com OxyProof Series Pressure transmitters oxygen applications ENGINEERING PROPOSAL OUTLINE DRAWING Electrical termination: 43650-A Pressure connection: 1/4" (1/4" BSP) (0.18) (1.06) (0.47) (2.86) (0.33) (0.47) vent hole G1/4" (1/4" BSP) 27.0 (1.06) diam. mass: dimensions (inches) Note: Other pressure ranges, output signals, electrical terminations pressure connections available request. Minimum order quantity apply. Please contact your nearest Sensortechnics sales office further information. Sensortechnics reserves right make changes products herein. Sensortechnics does assume liability arising application product circuit described herein, neither does convey license under patent rights rights others. March 2008 www.sensortechnics.com Other recent searchesYG975C6R - YG975C6R YG975C6R Datasheet uPA1742TP - uPA1742TP uPA1742TP Datasheet SP5668 - SP5668 SP5668 Datasheet DS4538 - DS4538 DS4538 Datasheet SML-311 - SML-311 SML-311 Datasheet NJM2277 - NJM2277 NJM2277 Datasheet NJM2277G - NJM2277G NJM2277G Datasheet NJM2277M - NJM2277M NJM2277M Datasheet MSM6568A - MSM6568A MSM6568A Datasheet 2N3507L - 2N3507L 2N3507L Datasheet 2N3507LJ - 2N3507LJ 2N3507LJ Datasheet 2N3507LJX - 2N3507LJX 2N3507LJX Datasheet 2N3507LJV - 2N3507LJV 2N3507LJV Datasheet 2N3507LJS - 2N3507LJS 2N3507LJS Datasheet
Privacy Policy | Disclaimer |