| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Features: Vin, Isolated, Fixed Conversion Ratio Watt Output Vin, Watt
Top Searches for this datasheetEUS20-120 Model Features: Vin, Isolated, Fixed Conversion Ratio Watt Output Vin, Watt Output Vin, Industry Standard Brick Footprint Remote Enable (Primary Side, Positive Negative) Over-temperature Over Current Protection Direct Parallel Operation Higher Power RoHS Compliant Table Input Characteristics Input Voltage Operating Range Input Voltage Absolute Maximum Input Undervoltage Lockout Notes Conditions -0.1 -0.1 Table Output Characteristics Output Voltage Point (Vo=Vin/4 +0/-0.5%) Output Load Regulation Output Voltage Total Regulation Output Ripple Voltage Noise Output Current Operating Range Output Current Share Accuracy Efficiency Turn-On Time Start-up Inhibit Time Transient Response Maximum Output Capacitance Notes Conditions 48.0 Bandwidth Percent deviation from ideal present: Enable Vout Enabled: applied Vout step, 0.1A/s, Recovery Time 95.5 2000 11.94 Typ. 11.98 12.0 13.75 13.25 Units Typ. 37.5 35.5 Units Input Overvoltage Lockout Maximum Input Current No-Load Input Current Disabled Input Current Input Reflected Ripple Current Inrush Current Transient Enable Negative Logic Version Internal pull-up Enable Positive Logic Version Internal pull-down GND. Turn-on Threshold Turn-off Threshold Hysteresis Voltage Turn-on Threshold Turn-off Threshold Hysteresis Voltage Steady-State out) Enabled state, load Vin) Disabled state Vin) Note (10) State range State range State range State range Technical enquiries email: sales@murata-ps.com tel: +508 3000 EUS20-120-6200921520.B01 18/04/08 Murata Power Solutions CONVERTER EUS20-120 Model Table Protection Characteristics Output Over-Current Shutdown Over Temperature Shutdown Over Temperature Restart Hysteresis Notes Conditions Non-Latching Re-start rate Non-Latching Typ. Units msec Table General Specifications Isolation Voltage Isolation Resistance Storage Temperature Range Operating Temperature Range Thermal Measurement Location Temperature Material Flammability MTBF Notes Conditions Input Output Input Output Non-condensing Ambient mechanical drawing location 94V-0 Calculated (Bellcore TR-332) Demonstrated 2.28"L 0.9"W 0.48"H (max) (57.9L 22.9W 12.19H max) 2250 Typ. Units Mohm Dimension Weight grams Table Standards Compliance UL/CSA 60950 EN60950 Notes Conditions Basic Insulation Certified Notes: 48Vdc, Airflow data unless otherwise noted. Output ripple voltage noise specified when measured with 10uF tantalum ceramic capacitor converter output pins. Transient response specified without capacitor output converter. Product operates with external capacitance significantly greater than specified. However, values higher than 2000uF please contact representative. Thermal shutdown monitored Thermal Measurement Location (TML). `Mechanical Information' page location. `Safety Considerations' shown last page. De-rating curves conducted controlled environment. application testing required ensure Thermal Measurement Location temperature below maximum specified. Recommended airflow direction from (transverse airflow). Current share accuracy optimized when source load impedance presented each converter equal. Input Reflected Ripple specified when measured with 12uH source inductance. EUS20-120-6200921520.B01 18/04/08 Murata Power Solutions Mechanical Information CONVERTER EUS20-120 Model Figure Assignment Table Name Vi(+) Vi(-) Vo(-) Vo(+) Function Positive Input Voltage Input Enable Disable Negative Input Voltage Negative Output Voltage Positive Output Voltage Referenced Vi(-). Positive Logic: Floating Enabled Negative Logic: Floating Disabled Notes Conditions EUS20-120-6200921520.B01 18/04/08 Murata Power Solutions CONVERTER EUS20-120 Model Efficiency Curves Efficiency Iout 55Vin 48Vin 42Vin 38Vin Output Voltage Current EUS20-120-6200921520.B01 18/04/08 Murata Power Solutions CONVERTER EUS20-120 Model Airflow from Iout Tamb Flow (LFM) Thermal Derating Curves (Transverse) TTML=120C Iout Tamb Flow (LFM) Iout Tamb Flow (LFM) Iout Tamb Flow (LFM) Output Power Curves function Ambient Temperature Ambient Temperature EUS20-120-6200921520.B01 18/04/08 Murata Power Solutions Turn-on from (Enable CONVERTER EUS20-120 Model Turn-on from Enable (Vin present) Figure Ch1: Vin; Ch2: Vout Vin=48V, Io=20A, Co=1000uF Figure Enable; Ch2: Vout Vin=48V, Io=20A, Co=1000uF Output Ripple/Noise Thermal Image 140.0°C SP01: 83.4 SP03: 78.0 SP02: 77.0 SP05: 91.2 SP04: 86.7 40.0°C Figure Vin=48V, Io=20A Vripple mVpp Figure Vi=48 Iout=20 bottom side EUS20-120-6200921520.B01 18/04/08 Safety Considerations series converters certified standards listed `Standards Compliance' section table above. this product built into information technology equipment, installation must comply with above standard. external input fuse recommended), must used meet above requirements. output converter [Vo(+)/Vo(-)] considered remain within SELV limits when input converter meets SELV TNV-2 requirements. converters materials meet 94V-0 flammability ratings. Figure Ordering Information EUS20-120-6200921520.B01 18/04/08 Other recent searchesSN74HC20 - SN74HC20 SN74HC20 Datasheet SN54HC20 - SN54HC20 SN54HC20 Datasheet RPS-75 - RPS-75 RPS-75 Datasheet MMDT4403 - MMDT4403 MMDT4403 Datasheet LL61126 - LL61126 LL61126 Datasheet ICS553 - ICS553 ICS553 Datasheet ICS552-02 - ICS552-02 ICS552-02 Datasheet BD3867AS - BD3867AS BD3867AS Datasheet AKD4556-B - AKD4556-B AKD4556-B Datasheet 2SC4940 - 2SC4940 2SC4940 Datasheet 2SA1646 - 2SA1646 2SA1646 Datasheet
Privacy Policy | Disclaimer |