| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Wide Input Range, Single Dual Output DC/DC Converters Features:
Top Searches for this datasheetA500RW Series Wide Input Range, Single Dual Output DC/DC Converters Features: Output Power Approved (File E245422) Input Voltage Range 1,500 Isolation Meets EN55022 Class Compact Case Single Dual Outputs MTBF Industry Standard Pin-Out Input Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. Typ. Max. Input Input Input 12.0 16.0 Input 16.0 24.0 32.0 (Pi) Filter (Complies with EN55022 Class "A") 1,000 3,000 Min. Typ. ±0.5 ±0.5 ±0.1 ±0.3 Max. ±1.0 ±2.0 ±0.3 ±1.0 ±6.0 ±0.02 Units Units Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple Noise MHz) (Note Ripple Noise MHz) Ripple Noise MHz) Output Power Protection Transient Recovery Time (Note Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Dual Output Balanced Loads Iout 100% Over Line, Load Temp. Load Step Change Continuous Conditions Seconds kHz, Min. 1,500 1,000 Typ. Max. Units Units ±2.0 ±0.01 RoHS Compliant General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conducted Conditions Min. Typ. Free Convection Non-condensing Six-Side Shielded Metal Case EN55022 Class Ambient Case Max. +125 MicroPower Direct Page Street Suite Stoughton, 02072 (781) 344-8226 (781) 344-8481 sales@micropowerdirect.com www.micropowerdirect.com Physical Case Size Case Material Weight 1.25 0.80 0.40 Inches (31.8 20.3 10.2 Metal with Non-Conductive Base (UL94-V0) 0.42 (12g) Conditions Min. Typ. HDBK 217F, Benign 1950, 60950, 60950 cUL; File E245422 Conditions Input Input Input Input From Case Models Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. Units MHours Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Absolute Maximum Ratings Parameter Input Voltage Surge Sec) Lead Temperature Internal Power Dissipation Max. 10.0 25.0 50.0 100.0 2,500 Units Caution: Exceeding Absolute Maximum Ratings damage module. These continuous operating ratings. Model Selection Guide Model Number A501RW A502RW A503RW A504RW A505RW A506RW A507RW A511RW A512RW A513RW A514RW A515RW A516RW A517RW A521RW A522RW A523RW A524RW A525RW A526RW A527RW A551RW A552RW A553RW A554RW A555RW A556RW A557RW Voltage (VDC) Nominal Range 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 36.0 18.0 36.0 18.0 36.0 18.0 36.0 18.0 36.0 18.0 36.0 18.0 36.0 36.0 75.0 36.0 75.0 36.0 75.0 36.0 75.0 36.0 75.0 36.0 75.0 36.0 75.0 Input Current (mA) Full-Load 1,056 1,265 1,463 1,463 1,265 1,463 1,463 Output Reflected Efficiency Current Ripple Voltage Current Typ) (VDC) (mA, Max) (mA, Min) No-Load Current (mA, Typ) Fuse Rating Slow-Blow (mA) 1,500 1,500 1,500 1,500 1,500 1,500 1,500 3,000 3,000 3,000 3,000 3,000 3,000 3,000 12.0 15.0 ±5.0 ±12.0 ±15.0 12.0 15.0 ±5.0 ±12.0 ±15.0 12.0 15.0 ±5.0 ±12.0 ±15.0 12.0 15.0 ±5.0 ±12.0 ±15.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 Notes: When measuring output ripple, recommended that external 0.47 ceramic capacitor placed from +Vout -Vout single output units from each output common dual output units. noise sensitive applications, capacitors will reduce output ripple. Transient recovery measured within error band load step change 100%. Operation no-load will damage these units. However, they meet specifications. Dual output units connected provide VDC, output. this, connect load across positive (+Vout) negative (-Vout) outputs float output common. converter should connected ac-impedance source. input source with highly inductive impedance affect stability converter. applications where converter output loading high input power supplied over long lines, necessary capacitor input insure start-up. this case, recommended that (ESR <1.0 kHz) capacitor mounted close converter. input units recommended, input units, units recommended that fuse used input power supply protection. table above correct rating. Derating Curve Mechanical Dimensions Connections Single -Vin Dual -Vin Common -Vout Single +Vout -Vout +Vin Dual +Vout Common +Vin Connection Capacitive Load Single Output 6,800 Dual Output ±1,000 Mechanical Notes: dimensions typical inches (mm) Tolerance x.xx ±0.01 (±0.25) Leads gold plated improved solderability. MicroPower Direct www.micropowerdirect.com Page Street Stoughton, 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com Other recent searchesTDA8004AT - TDA8004AT TDA8004AT Datasheet SN74ALS2233A - SN74ALS2233A SN74ALS2233A Datasheet Si7900EDN - Si7900EDN Si7900EDN Datasheet P89LPC922A1 - P89LPC922A1 P89LPC922A1 Datasheet IRLR7833 - IRLR7833 IRLR7833 Datasheet IRLU7833 - IRLU7833 IRLU7833 Datasheet 60DN2E3224 - 60DN2E3224 60DN2E3224 Datasheet 1759610000 - 1759610000 1759610000 Datasheet
Privacy Policy | Disclaimer |