| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Universal input Full range AD-55 series Protections: Sh
Top Searches for this datasheetSingle Output with Battery Charger(UPS Function) Universal input Full range AD-55 series Protections: Short circuit Overload Over voltage Battery protections Cooling free convection 100% full load burn-in test Fixed switching frequency 45KHz years warranty SPECIFICATION MODEL OUTPUT NUMBER VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE AD-55A 13.8V 3.5A 51.38W -1600ms, 50ms/115VAC full load 16ms/115VAC full load 370VDC 13.4V 0.23A -AD-55B 27.6V 1.8A 53.92W 100mVp-p CH1: 1.0% 0.5% 0.5% -CH2 26.5V 0.16A RIPPLE NOISE (max.) Note.2 100mVp-p CH1: 14.5V VOLTAGE TOLERANCE Note.3 1.0% 0.5% 0.5% 800ms, 50ms/230VAC 80ms/230VAC 264VAC 63Hz 1.6A/115VAC 1A/230VAC COLD START 20A/115VAC 40A/230VAC <1mA 240VAC 150% rated output power Protection type Hiccup mode, recovers automatically after fault condition removed CH1:14.49 18.63V CH1:28.98 37.26V FUNCTION Protection type Hiccup mode, recovers automatically after fault condition removed fail PIN2 ALARM SIGNAL(OPTIONAL) Battery under charge voltage 82.5% PIN1 Normal 0.8V max. Abnormal 0.5V (Refer output load derating curve) non-condensing 0.03%/ (0~50 output 500Hz, 10min./1cycle, 60min. each along axes UL60950-1, EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE HARMONIC CURRENT IMMUNITY MTBF OTHERS DIMENSION PACKING SAFETY (Note I/P-O/P, I/P-FG, O/P-FG:100M Ohms 500VDC/ CONDUCTION RADIATION Compliance EN55022 (CISPR22) Class Compliance EN61000-3-2,-3 Compliance EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria 304.3K min. MIL-HDBK-217F 159*97*38mm (L*W*H) 0.5Kg; 24pcs/12.6Kg/0.75CUFT NOTE parameters specially mentioned measured 230VAC input, rated load ambient temperature. Ripple noise measured 20MHz bandwidth using twisted pair-wire terminated with 0.1uf 47uf parallel capacitor. Tolerance includes tolerance, line regulation load regulation. power supply considered component which will installed into final equipment. final equipment must re-confirmed that still meets directives. File Name:AD-55-SPEC 2008-10-08 Single Output with Battery Charger(UPS Function) Mechanical Specification 152.5 AD-55 Case series Unit:mm 8.25 84.5 Terminal Assignment 18.5 Assignment AC/L AC/N OUTPUT Assignment OUTPUT BAT. BAT.-/COM 28.5 Block Diagram fosc 45KHz BAT. CHARGER BACK RECTIFIERS FILTER RECTIFIERS FILTER FILTER POWER SWITCHING COM/B- O.L.P. CONTROL DETECTION CIRCUIT Derating Curve Static Characteristics Ta=25 With 18.2CFM min.(10cm) +13.8V (HORIZONTAL) AMBIENT TEMPERATURE INPUT VOLTAGE 60Hz File Name:AD-55-SPEC 2008-10-08 OUTPUT RIPPLE (mVp-p) +13.8V OUTPUT VOLTAGE LOAD Other recent searchesPS-0610-082 - PS-0610-082 PS-0610-082 Datasheet ML4632 - ML4632 ML4632 Datasheet ML4661 - ML4661 ML4661 Datasheet ML4662 - ML4662 ML4662 Datasheet M38D29FFHP - M38D29FFHP M38D29FFHP Datasheet FC124 - FC124 FC124 Datasheet CY7B144 - CY7B144 CY7B144 Datasheet CY7B145 - CY7B145 CY7B145 Datasheet CSM-20-15G - CSM-20-15G CSM-20-15G Datasheet BUK9514-55A - BUK9514-55A BUK9514-55A Datasheet BUK9614-55A - BUK9614-55A BUK9614-55A Datasheet AN333 - AN333 AN333 Datasheet
Privacy Policy | Disclaimer |