| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
SIngle triple output Rev.02.15.07 NFS40 Medical Total Power:
Top Searches for this datasheetNFS40 Series SIngle triple output Rev.02.15.07 NFS40 Medical Total Power: Input Voltage: 264VAC 370VDC Outputs: Single, triple Special Features inch package applications) Industry standard package Overvoltage short circuit protection with free convection EN55022, EN55011 conducted noise level safety approvals Available RoHS compliant year warranty Safety NFS40-79XXJ models approved UL2601, CSA22.2 IEC601/VDE0750 standards. NFS40-79XXJ series ordinary, patient-connect applications under UL2601 C22.2 standards, authorised non-critical, non-patient-connect applications under IEC601 standards. NFS40 medical series universal input ac-dc power supply inch card with maximum component height inches medical applications. NFS40 medical series same generic feature standard NFS40 series been designed with lower safety ground leakage higher isolation required medical safety approval. NFS40 provides output power with free convection cooling which boosted with air. Standard features include overvoltage short-circuit protection. series, with full medical safety approval EN60601 UL2601 mark, meets conducted emissions EN55022 level NFS40 medical series designed power medical, dental laboratory applications such dialysis machines, monitoring equipment, instrumentation infusion pump controls. Specifications specifications typical nominal input, full load 25°C unless otherwise stated Rev.02.15.07 NFS40 Medical OUTPUT SPECIFICATIONS Voltage adjustability Line regulation Overshoot/undershoot Transient response Temperature coefficient Overvoltage protection Minimum output current Output power limit Short circuit protection INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Safety ground leakage current Cold start Vac, Cold start Vac, Vac, Vac, 85-264 120-370 47-440 max. max. output triples Vout singles main output auxiliary output turn-on (1.5 step) outputs output (See Note Primary power limited Single Multiple ±5.0% ±5.0% ±0.2% ±1.0% ±120 dev. recovery ±0.02%/°C 6.25 ±0.75 Vout input power limit Continuous Short term CHARACTERISTICS Conducted emissions Radiated emissions contact Surge Fast transients Radiated immunity Conducted immunity GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Switching frequency Approvals standards (See Note Weight MTBF MIL-HDBK-217E Vac, Input/output Input/chassis typical 4000 1500 20-10 VDE0750, IEC601 EN60601-1, UL2601 C22.2 (9.6 170,000 hours EN55022, part EN55022, part EN61000-4-2, level EN61000-4-2, level EN61000-4-5, level EN61000-4-4, level EN61000-4-3, level EN61000-4-6, level Level Level Perf. criteria Perf. criteria Perf. criteria Perf. criteria Perf. criteria Perf. criteria ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating, curve +70°C Non-operating +85°C ambient temp., convection cooled ambient, Forced ambient Derate linearly load Peak seconds) Non-condensing Operating Non-operating 5-500 10,000 feet max. 40,000 feet max. 0.75 peak Relative humidity Altitude Vibration (See Note Specifications Contd. OUTPUT VOLTAGE +5.1 (VA) (VB) Rev.02.15.07 NFS40 Medical OUTPUT CURRENT CONV. 0.35 0.35 0.35 0.35 20CFM MAX. PEAK RIPPLE PK-PK TOTAL REGULATION ±2.0% ±5.0% ±5.0% ±2.0% +10%/-3.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% ±5.0% ±5.0% MODEL NUMBERS (13,14) NFS40-7908J +5.1 (VA) (VB) NFS40-7910J NFS40-7912J NFS40-7915J NFS40-7924J NFS40-7928J +5.1 Notes mating connector Molex 09-50-3031 equivalent with Molex 08-50-0105 equivalent crimp terminal. Natural convection cooling, maximum. Forced air, atmosphere, maximum. Peak output current lasting less than seconds with duty cycle less than 10%. During peak loading, outputs outside total regulation limits. Peak total power must exceed bandwidth, peak-to-peak, measured differentially. Total regulation defined static output regulation including initial tolerance, load currents within stated limits, output voltages adjusted their factory settings. Also, 0.25 maintain stated regulation. minimum load required output obtain full current from negative output. Single output models have floating outputs which referenced either positive negative. Derating curve application specific ambient temperatures optimum reliability part heatsink should exceed semiconductor case temperature should exceed Caution: Allow minimum second after disconnecting power when making thermal measurements. Although minimum output current NFS40-79XXJ minimum load required achieve design MTBF. Three orthogonal axes, sweep octave/min, minute dwell four major resonances. This product only inclusion professional installers within other equipment must operated stand alone product. suffix indicates that these parts Pb-free (RoHS 6/6) compliant. RoHS (non Pb-free) compliant versions available special request, please contact your local sales representative details. NOTICE: Some models support options. Please contact your local Artesyn representative on-line model number search tool find suitable alternative. mating connector Molex 09-91-0600 equivalent with Molex 08-50-0164 equivalent crimp terminal. CONNECTIONS Safety Earth Ground +5.1 +5.1 Return Return +5.1 +5.1 Return Return +Vout +Vout +Vout Return Return Return -7908J, 7928J Line Neutral -7901J Line Neutral SINGLES Line Neutral Rev.02.15.07 NFS40 Medical Mechanical Notes order meet safety requirements, non-metallic stand-off mandatory hole specified mechanical drawing above. ground mounting hole near allows system grounding through metal stand-off. improve conducted noise, ground mounting hole near output connector should connected with ground mounting hole near metal stand-offs attached common metal chassis. This connection also significantly attenuates common mode noise. standard L-bracket cover available mounting which contains screws, connectors necessary mounting hardware. Order part number `NFS40 COVER KIT'. Americas 5810 Allen Carlsbad, 92008 Telephone: 4600 Facsimile: 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, United Kingdom Telephone: 1384 Facsimile: 1384 MAXIMUM COMPONENT HEIGHT inches 0.156 (3.96) Dia. Places) 5.00 (127.00) Asia (HK) 16th 17th Floors, Plaza Wing Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 NON-METALLIC STAND-OFF (SEE NOTE 3.00 (76.2) 3.15A, 250VAC (SEE NOTE 2.550 (64.8) global contact, visit: www.powerconversion.com While every precaution been taken ensure accuracy completeness this literature, Emerson Network Power assumes responsibility, disclaims liability damages resulting from this information errors omissions. 0.22 (5.59) 4.55 (115.8) 0.22 (5.59) DIMENSIONS INCHES (mm) Emerson Network Power. global leader enabling business-critical continuity. Power Connectivity Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring Services EmersonNetworkPower. Emerson Network Power Emerson Network Power logo trademarks service marks Emerson Electric ©2007 Emerson Electric Other recent searchesSKY73089-11 - SKY73089-11 SKY73089-11 Datasheet SEEB0VTF-50728 - SEEB0VTF-50728 SEEB0VTF-50728 Datasheet SC40-18GWA - SC40-18GWA SC40-18GWA Datasheet HCPL-3000 - HCPL-3000 HCPL-3000 Datasheet CWT-9002 - CWT-9002 CWT-9002 Datasheet BL15-6F - BL15-6F BL15-6F Datasheet ADN2816 - ADN2816 ADN2816 Datasheet
Privacy Policy | Disclaimer |