| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
TR11 Series E209569 Amps UL1077 Recognized Supplementary Pro
Top Searches for this datasheetAltech UL1077 TR11 Series E209569 Amps UL1077 Recognized Supplementary Protector/ Circuit Breaker Equipment Applications: Protection single phase Motors, Transformers, UPS, Power strips, Solenoids etc., against damage overcurrent conditions. Current Rating Rated Voltage Initial insulation resistance Dielectric strength Overload Switching Capacity Maximum Breaking Capacity Power Loss Operating Temperature Operational Life 2xIn Limited short circuit current Terminals Applicable Standards Approvals Accessories -16.0A 240V 50/60Hz, (VDE) 60934) ohms. 60934) minute. 9.0A 60934) 12.0A Max. from 10.0A 12.0A Max. from 10.0A 12.0A <6.0A MAX. 6.0A Watts Maximum 60°C Ambient 1000 Cycles 1000 Amps Operating Characteristic (min) Trip time 1.05 1.32 0.25" Quick connect 60934, 22.2 235, UL-1077 16.0 upto 12.0A Dust Cover, DC-TR11 (see page Time Current Characteristics: standard characteristic valid ambient temperatures +23°C. device used ambient temperature other than +23°C, allowances must made when selecting current rating according following guidelines: Ambient temp. Correction Factor Example 0.96 1.05 1.12 0.88 Normal Continuous Current Ambient Temperature Correction Factor Recommended Current Rating Select nearest 1.8A 40°C 1.12 1.12 2.016 2.0A Multiple Rated Current Rated current Ambient Temperature 23°C Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908)806-9400 (908)806-9490 www.altechcorp.com Application Examples: Protection single phase Motors, Transformers, UPS, Power strips, Solenoids etc., against damage overcurrent conditions. TR-11 Characteristics Mounting Options E209569 Type/ Cat. TR-11CX630.5A TR-11CX630.9A TR-11CX631A TR-11CX631.2A TR-11CX631.5A TR-11CX631.8A TR-11CX632A TR-11CX632.2A TR-11CX632.5A TR-11CX632.7A TR-11CX633A TR-11CX633.3A TR-11CX634A TR-11CX635A TR-11CX636A TR-11CY636.5A TR-11CY637A TR-11CY638A TR-11CY639A TR-11CY6310A TR-11CY6312A TR-11CY6315A TR-11CY6316A Type/ Cat. Amps Rated Current Type/ Cat. Standard Pack: Weight: 0.27kg (0.6 lb.) Central Mounting Rated Current 0.5A 0.9A 1.0A 1.2A 1.5A 1.8A 2.0A 2.2A 2.5A 2.7A 3.3A 6.5A Rated Current Standard Pack: Weight: 0.27kg (0.6 lb.) Wing Clips* Rated Current Type/ Cat. Standard Pack: Weight: 0.27kg (0.6 lb.) Snap Fitting* Standard Pack: Weight: 0.27kg (0.6 lb.) Integral Mounting* SPECIAL ORDER ONLY. Contact Altech more details. Mounting additional Shunt Terminal available, please contact Altech. Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908)806-9400 (908)806-9490 www.altechcorp.com Altech UL1077 Altech UL1077 TR-11 Dimensions Mounting Options Central Mounting MAXIMUM TORQUE 13.3/14.5 10.8/12 PANEL CUTOUT 27.5 10.2 Wing Clips 10.2 Alternate 14.5 Alternate PANEL CUTOUT 9+0.1 15.5 27.5 12.7 15.2 13.9 +0.1 Snap Fitting 11.2 PANEL CUTOUT 25.6 21.7 +0.1 11.3 +0.1 Integral Mounting 11.2 27.5 Dust Cover Cover suitable central mounting type circuit breaker provide dust splash protection 54). Type/Cat. No.: TR11 Dimensions convert inches multiply 0.03937) Altech Corp.® Royal Road Flemington, 08822-6000 Phone (908)806-9400 (908)806-9490 www.altechcorp.com Other recent searchesuPD44325082-A - uPD44325082-A uPD44325082-A Datasheet uPD44325092-A - uPD44325092-A uPD44325092-A Datasheet uPD44325182-A - uPD44325182-A uPD44325182-A Datasheet uPD44325362-A - uPD44325362-A uPD44325362-A Datasheet PS9701-F3 - PS9701-F3 PS9701-F3 Datasheet PCF8812 - PCF8812 PCF8812 Datasheet ICL7673 - ICL7673 ICL7673 Datasheet GL6CU7 - GL6CU7 GL6CU7 Datasheet CW9100 - CW9100 CW9100 Datasheet BCM5414 - BCM5414 BCM5414 Datasheet
Privacy Policy | Disclaimer |