Galvanic Isolator EN50020-EN50039, FM3610, CSA22.2 No.157, UL913


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Hazardous Location Pneumatic Switches
Galvanic Isolator
EN50020-EN50039, FM3610, CSA22.2 No.157, UL913 Approvals CSA, CENELEC (PTB) approved marked applicable directives Power Supply 32mA 18-35V Number Inputs Signal Range 8.2mA Input Switching Current 2.1mA 1.2mA Input Resistance 1000 ohms Isolation Protection 1500V Output SPST Output Contact Rating 2A/250V 2A/120V 2A/24V Switching Frequency 15Hz Switch Delay 15ms 15ms Indication LEDs Green Power Yellow Output Closed Wire Break/Short Operating Temperature -20°C +65°C (-4°F +149°F) Humidity Housing Material Polyamide Enclosure Protection IP30 Mounting 35mm rail Conductor Size 0.2-2.5mm2 (24-14AWG) Weight Mechanical Contact Life 120g (0.26lbs) 20,000,000 cycles Standards
APPROVED
Description
galvanic isolators active protective interface assemblies isolate intrinsically safe circuits from intrinsically safe circuits worldwide standards. Galvanic isolators offer economical solutions instrumentation control systems hazardous locations. Unlike zener diode barriers, galvanic isolators require grounding. Allen-Bradley's galvanic isolators provide 1500 volt isolation between hazardous area hazardous area terminals volt isolation between input/output external power terminals. switches provide convenient programming output diagnostic functions. Multiple LEDs allow easy visual indication module circuit status. Wiring intrinsically safe systems must identified such through light blue jacketing and/or through appropriate labels. Such labels required Article ANSI/ISA RP-12.6 placed more than foot intervals. When installing intrinsically safe equipment user should refer relevant national standards and/or those standards forth "authority having jurisdiction" installation site.
Entity Table
Groups E,F, 10.6V 29.7mA 2.5uF 15uF 40mH 150mH
Features
Galvanic isolation input-to-output Reverse polarity protected 500V isolation between input output separate intrinsically safe grounding required 18mm (0.71in) wide housing 35mm rail mount
16-6
Hazardous Location Pneumatic Switches
Galvanic Isolator
Product Selection
Product Galvanic Isolator External Power 32mA 18-35VDC Output type SPST 250V Catalog Number 897H-G231
Approximate Dimensions-mm (inches) Block Diagram
(0.71) (4.5)
(3.15)
Switch Settings
1234 1111
Typical Wiring Diagrams
Hazardous Location U.S. Class III, European Zone EExia Entity Parameters 897H Groups Bulletin 800E Latching E-stop Galvanic Isolator 897H-G231 Stop hazardous Location (Aux) Start (Aux)
Reset
440K Tongue Interlock
Input
6.8K Resistors 1492-WD4RA682 Open Switch Settings 1234 LMinotaur Dual Channel Safety Relay
Input
Safety Gate
Ground
440F MatGuard Pressure Sensitive Safety
6.8K Resistor 1492-WD4RA682 440F GuardEdge Pressure Sensitive Sensing Edge
16-7

Other recent searches


TH8053 - TH8053   TH8053 Datasheet
SV6111 - SV6111   SV6111 Datasheet
SG723 - SG723   SG723 Datasheet
KBPC25 - KBPC25   KBPC25 Datasheet
FTLF8528P2BNV-AS - FTLF8528P2BNV-AS   FTLF8528P2BNV-AS Datasheet
FM4728A-FM4764A - FM4728A-FM4764A   FM4728A-FM4764A Datasheet
EN3416B - EN3416B   EN3416B Datasheet
LB1662D - LB1662D   LB1662D Datasheet
LB1662M - LB1662M   LB1662M Datasheet
BHC44 - BHC44   BHC44 Datasheet
AS7C4096A - AS7C4096A   AS7C4096A Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive