Safety Contactors 100S-D Specifications Conformity Standards
Top Searches for this datasheetContactors Control Relays Safety Contactors 100S-D Specifications Conformity Standards 60947-4 60947-4 Annex 60947 Type Coordination 22.2 Approvals Description Bulletin 100S-D safety contactors designed provide safe isolation hazardous motion loads, utilizing "mirror contact" performance. Mirror contacts provide reliable indication about open/closed status main power poles. marked applicable directives Certified Listed SUVA Certified Features 45.220 @500V 60.600 @460V 75.700 @575V Electronic Conventional Coils Integrated Interface Power Pick-Up Hold-In Wide Voltage Ranges Complete Range Accessories Environmentally-Friendly Compact Dimensions Contactors Control Relays Safety Contactors 100S-D Product Selection 3-pole Contactors Conventional Electronic Coils Main Contacts Non-Reversing 60°C 40°C Switching 3-Phase Motors-AC-2, AC-3 Auxiliary Contacts N.O. N.C. AC-3 AC-1 230V 400V 415V 1000 500V 690V 1000V 200V 230V 460V 575V Catalogue Number 100S-D9522C 100S-D11022C 100S-D14022C 100S-D18022C 100S-D21022C 100S-D25022C 100S-D30022C 100S-D42022C 100S-D63022C 100S-D86022C 80/90 110/132 90/110 132/160 Coil Voltage Code Catalogue Number listed incomplete. Select coil voltage code from table below complete Catalogue Number. Example: 120V Catalogue Number 104S-C09210C becomes Catalogue Number 104S-C09D210C. Conventional Coil 100S-D95. 100S-D180 100S-D95. 100S-D110 50/60 220. 380. Electronic Coil w/PLC Interface 100S-D95. 100S-D250 100S-D300. 100S-D420 100S-D630. 100S-D860 50/60 50/60 50/60 110. 208. 380. 440. N.C. contacts meet 60947-4 Annex requirements mirror contact performance. N.C. mirror contacts wired series parallel must used monitoring contacts with feedback safety circuit. Signal voltage Cat. 100S-D. electronic interface:Ue: DC/Ie: Pick-Up Voltage: 13.0V DC.30.2V Drop-Out Voltage: -3.0V DC.+5.0V Higher rating only applies contactors with electronic coil. 9-10 Contactors Control Relays Safety Contactors 100S-D Product Selection 3-Pole Contactors Conventional Electronic Coils Main Contacts Non-Reversing 60°C 40°C Switching 3-Phase Motors-AC-2, AC-3 Auxiliary Contacts N.O. N.C. AC-3 AC-1 230V 400V 415V 500V 690V 1000V 200V 230V 460V 575V 2/1L 2/1L 2/1L Catalogue Number 100S-D9533LC 100S-D9522C 100S-D11033LC 100S-D11022C 100S-D14033LC 100S-D14022C 100S-D18022C 100S-D21022C 100S-D25022C 100S-D30022C 100S-D42022C 100S-D63022C 100S-D86022C 1000 Coil Voltage Code Catalogue Number listed incomplete. Select coil voltage code from table below complete Catalogue Number. Example: 120V Catalogue Number 104S-C09210C becomes Catalogue Number 104S-C09D210C. Conventional Coil 100S-D95.100S-D140 Electronic Coil w/EI Interface 100S-D95.100S-D300 100S-D420 100S-D630.860 48.72 110.130 200.255 N.C. contacts meet 60947-4 Annex requirements mirror contact performance. N.C. mirror contacts wired series parallel must used monitoring contacts with feedback safety circuit. conventional coil only. pickup winding must interconnected with N.C. late-breaking auxiliary contacts. Signal voltage Cat. 100S-D. electronic interface:Ue: DC/Ie: Pick-Up Voltage: 13.0V DC.30.2V Drop-Out Voltage: -3.0V DC.+5.0V Higher rating only applies contactors with electronic coil. 9-11 Contactors Control Relays Safety Contactors 100S-C General Ratings Catalogue Number 100S-C09.100S-C85 Rated Isolation Voltage IEC, SEV, 0660; Rated Impulse Voltage Uimp Rated Voltage Main Contacts 50/60Hz Operating Frequency Loads 115, 200, 208, 230, 240, 380, 400, 415, 460, 500, 575, 690V 110, 115, 220, 230, 300, 440V 50.60 690V 600V Switching Motor Loads Catalogue Number Standard Ratings 230V 240V 400V 415V 500V AC-2, AC-3, AC-4-50Hz Reversing 690V 230V 240V 400V 415V 500V 690V 1-Ph 115V 230V 3-Ph 200V AC-2, AC-3, AC-4-60Hz Reversing UL/CSA/IEC [kW] [kW] [kW] [kW] [kW] [kW] [HP] [HP] [HP] [HP] [HP] [HP] 7-1/2 7-1/2 17.5 15.2 26.5 26.5 17.5 7-1/2 25.3 7-1/2 18.5 18.5 32.2 7-1/2 32.2 18.5 18.5 48.3 62.1 7-1/2 78.2 100SC09 100SC12 100SC16 100SC23 100SC30 100SC37 100SC43 100SC60 100SC72 100SC85 9-12 Contactors Control Relays Safety Contactors 100S-D General Ratings Catalogue Number 100S-D95.100S-D860 Rated Isolation Voltage IEC, SEV, 0660; Rated Impulse Voltage Uimp Rated Voltage Main Contacts 50/60Hz Operating Frequency Loads 115, 200, 208, 230, 240, 380, 400, 415, 460, 500, 575, 690, 1000V 110, 115, 220, 230, 300, 440V 50.60 690V 600V 12kV Switching Motor Loads Catalogue Number Conventional Coil Type Electronic-EI Standard Ratings 230V 240V 400V 415V 500V 690V AC-2, AC-3, AC-4-50Hz Reversing 1000V 230V 240V 400V 415V 500V 690V 1000V 1-Ph 115V 230V 3-Ph 200V AC-2, AC-3, AC-4-60Hz Reversing UL/CSA/IEC [kW] [kW] [kW] [kW] [kW] [kW] [kW] [HP] [HP] [HP] [HP] [HP] [HP] 78.2 100SD95 100SD110 100SD140 100SD140 100SD180 100SD180 100SD210 100SD250 100SD300 100SD420 100SD630 100SD860 9-13 Contactors Control Relays Safety Contactors 100S-C Coil Data Catalogue Number Voltage Range 50/60 Pick-up Dropout Pick-up Dropout Coil Consumption 50/60 Operating Time 50/60 with Suppressor with Integ. Suppres. with Diode Suppres. Pick-up Hold-in Pick-up Hold-in [VA/W] [VA/W] 70/50 8/2.6 70/50 8/2.6 70/50 8/2.6 70/50 80/60 80/60 130/90 10/3.2 10.1 10.1 200/110 16/4.5 200/110 16/4.5 200/110 16/4.5 0.3.0.6 0.8.1.1 0.1.0.6 100S-C09 100SC12 100SC16 100SC23 100SC30 100SC37 100SC43 100SC60 100SC72 100SC85 0.85.1.1 Pick-up Dropout Dropout Pick-up Dropout Dropout Dropout [ms] [ms] [ms] [ms] [ms] [ms] [ms] 15.30 10.60 10.60 40.70 7.15 14.20 70.95 15.30 10.60 10.60 40.70 7.15 14.20 70.95 15.30 10.60 10.60 40.70 7.15 14.20 70.95 15.30 10.60 10.60 40.70 7.15 17.23 80.125 15.30 10.60 10.60 50.80 7.15 17.23 80.125 15.30 10.60 10.60 50.80 7.15 17.23 80.125 15.30 10.60 10.60 50.80 7.15 17.23 80.125 20.40 10.60 10.60 20.40 20.35 80.125 20.40 10.60 10.60 20.40 20.35 80.125 20.40 10.60 10.60 20.40 20.35 80.125 9-14 Contactors Control Relays Safety Contactors 100S-D Coil Data Catalogue Number Conventional Coil Type Electronic-EI Voltage Range 50/60 Pick-up Dropout Pick-up Dropout Coil Consumption 50/60 Operating Time 50/60 with Suppressor with Integ. Suppres. with Diode Suppres. Pick-up Hold-in Pick-up Hold-in [VA/W] [VA/W] 75.90 Pick-up Dropout Dropout Pick-up Dropout Dropout Dropout [ms] [ms] [ms] [ms] [ms] [ms] [ms] 30.60 75.90 30.60 75.90 30.60 75.90 30.60 1980 60.100 70.145 60.100 70.145 0.3.0.5 0.85.1.1 0.3.0.5 370/243 12/6 590/355 15/7 0.3.0.8 0.80.1.1 0.3.0.8 1915/1720 33/30 0.85.1.1 100SD95 100SD110 100SD140 100SD140 100SD180 100SD180 100SD210 100SD250 100SD300 100SD420 100S-D630 100S-D860 0.85.1.1 Electronic coil drives designed minimize coil consumption. However, this design cause large inrush (<1ms) when energizing. This must taken into account when sizing power supplies, all-or-nothing relays cross-sections coil wires. 9-15 Contactors Control Relays Safety Contactors Connections 3-Pole Safety Contactors 100S-C0905C.C2305C 100S-C0914C.C2314C 100S-C3004C.C8504C 4-Pole Safety Contactors 100S-C09404C.C23404C 100S-C09304C.C23304C Reversing Safety Contactors 104S-C09210C.C23210C 104S-C30010C.C85010C 9-16 Other recent searchesUT54ACS164245S - UT54ACS164245S UT54ACS164245S Datasheet SAA7231 - SAA7231 SAA7231 Datasheet INA-30311 - INA-30311 INA-30311 Datasheet FYL-3017EGW1A - FYL-3017EGW1A FYL-3017EGW1A Datasheet EMC48S50-04 - EMC48S50-04 EMC48S50-04 Datasheet IAC53a - IAC53a IAC53a Datasheet CAT580 - CAT580 CAT580 Datasheet BPW36 - BPW36 BPW36 Datasheet BPW37 - BPW37 BPW37 Datasheet AD668 - AD668 AD668 Datasheet AD-3136 - AD-3136 AD-3136 Datasheet
Privacy Policy | Disclaimer |