The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Wesentliche Merkmale GaAlAs-LED sehr hohem Wirkungsgrad Hohe Hohe Impu


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



GaAIAs-IR-Lumineszenzdiode (880 GaAIAs Infrared Emitter (880 1047A 1047B
Wesentliche Merkmale GaAlAs-LED sehr hohem Wirkungsgrad Hohe Hohe Impulsbelastbarkeit Gute spektrale Anpassung Vorderseitenmetallisierung: Aluminium Goldlegierung Lieferung: vereinzelt Folie
Features Chip size Very highly efficient GaAlAs High reliability High pulse handling capability Good spectral match silicon photodetectors
Frontside metallization: aluminum Backside metallization: gold alloy Delivery: diced foil Applications remote control hifi sets, video tape recorder, dimmers Remote control steady varying intensity Light-reflection switches (max. kHz) Coin counters Sensor technology Discrete optocouplers
Anwendungen IR-Fernsteuerung Fernseh-, Rundfunkund Lichtdimmern Gleich- Wechsellichtbetrieb Lichtschranken Sensorik Diskrete Optokoppler
Type 1047A 1047B
Bestellnummer Ordering Code request request
Beschreibung Description Infrarot emittierender Chip, Oberseite Kathodenanschluss Infrared emitting die, side cathode connection Infrarot emittierender Chip, Oberseite Kathodenanschluss, aufgerauht Infrared emitting die, side cathode connection, surface frosted
2001-10-04
1047A, 1047B
Elektrische Werte (gemessen TO18-Bodenplatte ohne Verguss, Electrical values (measured TO18 header without resin, Bezeichnung Parameter Strahlung Wavelength peak emission Spektrale Bandbreite Imax, Spectral bandwidth Imax Sperrspannung Reverse voltage 10µA Schaltzeiten, 10%, Switching times, from from 10%, Durchlaspannung Forward voltage Gesamtstrahlungsflu Total radiant flux 1047A 1047B Symbol Symbol min. peak Wert Value typ. max. Einheit Unit
0.5/0.4
1.55
2001-10-04
1047A, 1047B
Mechanische Werte Mechanical values Bezeichnung Parameter Abmessungen aktiven Dimension active chip area Durchmesser Wafers Diameter wafer height Bondpaddurchmesser Diameter bondpad Symbol Symbol min. Wert Value typ. max. Einheit Unit
Bezeichnung Parameter Vorderseitenmetallisierung Metallization frontside Metallization backside Trennverfahren Dicing Verbindung Chip bonding
Wert Value Aluminium Aluminum Goldlegierung Gold alloy Sawing Kleben Epoxy bonding
2001-10-04
1047A, 1047B
Grenzwert (gemessen TO18-Bodenplatte ohne Verguss,TA 25°C) Maximum Ratings (measured TO18 header without resin, Bezeichnung Parameter Betriebstemperatur Operating temperature range Lagertemperatur Storage temperature range Forward current Surge Current Symbol Symbol Tstg Wert Value -40.+100 -40.+100 Einheit Unit
2001-10-04
1047A, 1047B
Relative Spectral Emission Radiant Intensity (IF) Single pulse,
OHR00877
(100mA)
OHR00878
1000
Permissible Pulse Handling Capability duty cycle parameter
OHR00886
Forward Current, (VF) Single pulse,
OHR00881
0.005 0.01 0.02 0.05
above diagramms were obtained using Osram TOPLED (SFH 421) package characterisation
2001-10-04
1047A, 1047B
Chip Outlines
n-contact
0.13 (0.0051)
(0.0118)
0.21 (0.0083)
p-contact
GMOY6031
werden folgt angegeben: (inch) Dimensions specified follows: (inch).
Published OSRAM Opto Semiconductors GmbH Wernerwerkstrasse D-93049 Regensburg Rights Reserved. Attention please! information describes type component shall considered assured characteristics. Terms delivery rights change design reserved. technical requirements components contain dangerous substances. information types question please contact sales organization. Packing Please recycling operators known you. also help touch with your nearest sales office. agreement will take packing material back, sorted. must bear costs transport. packing material that returned unsorted which obliged accept, shall have invoice costs incurred. Components used life-support devices systems must expressly authorized such purpose! Critical components only used life-support devices systems with express written approval OSRAM critical component component used life-support device system whose failure reasonably expected cause failure that life-support device system, affect safety effectiveness that device system. Life support devices systems intended implanted human body, support and/or maintain sustain human life. they fail, reasonable assume that health user endangered.
2001-10-04

Other recent searches


TC1301A - TC1301A   TC1301A Datasheet
TC1301B - TC1301B   TC1301B Datasheet
SP8714 - SP8714   SP8714 Datasheet
DS3562 - DS3562   DS3562 Datasheet
MA05578 - MA05578   MA05578 Datasheet
CX24611 - CX24611   CX24611 Datasheet
BX6034 - BX6034   BX6034 Datasheet
BCM8111 - BCM8111   BCM8111 Datasheet
APTGT150DU120TG - APTGT150DU120TG   APTGT150DU120TG Datasheet
2SK1401 - 2SK1401   2SK1401 Datasheet
2SK1401A - 2SK1401A   2SK1401A Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive