| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDAT
Top Searches for this datasheet10/11-8.25 FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus (RTD), thermocouples, independent channels Input Resistance thermometer (2-, 4-wire circuit) Thermocouples Resistance remote signalling unit (0.500 0.4000 Voltages, calibrator (-125.+1200 Input functionality channels Electrcal isolation (I/O) between input output Digital, long-term solid processing measuring values Customer-specific linearization Continuous sensor self-monitoring acc. 61326 NAMUR recommendation Parameterization file Output FOUNDATION Fieldbus acc. specification Certified with Interoperbility Test Campaign Number: 015000 design acc. 61158-2, 31.25 kbit/s Backup function Reserve voltage protection solid current limitation Approvals explosion protection intrinsically safe ATEX Suitable connecting systems according Entity model FISCO model Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus (RTD), thermocouples, independent channels 10/11-8.25 Technical data Device type Link Master Device Link Active Scheduler (LAS) capability implemented Max. line resistance (RW) core 4-wire Measuring current Sensor short-circuit Sensor break (temperature/resistance measurement, 4-wire) Measuring range Measuring range 0.4000 4200 Sensor wire break monitoring accordance with NAMUR Sensor wire break detection 3-wire resistance measurement 4-wire resistance measurement Input filter 50/60 Thermocouples Types Voltages Range Accuracy -100 mV.+1200 mV.+ Power supply transmitter terminals) Supply voltage 9.32 explosion protection application dependent supply unit Supply voltage, poling protected Current consumption Operating (quiescent): 10.5 Fault current limiting: Output Interface/Protocol FOUNDATION Fieldbus 61158-2 FF-H1Version 31.25 kbit/s Registration: IT015000 Interoperbility Test Function blocks tested function blocks operating time: other function blocks Sensor monitoring current between measuring cycles Sensor wire break monitoring accordance with NAMUR Thermocouple measurement Voltage measurement Input filter 50/60 Internal reference junction Pt100, software switchable jumper necessary) Input Resistance (temperature linear) Resistance thermometer Pt100 Pt1000 (IEC 751: 0.1; 0.5; (JIS 1604: 0.1; 0.5; (SAMA: 0.1; 0.5; Ni50, Ni100, Ni120, Ni1000, Cu10, Cu100 Resistance Range 0.500 0.4000 Input element Standard 584-1 Sensor Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Resistance thermometer Pt100 Resistance thermometer Pt1000 Resistance thermometer Ni100 Resistance thermometer Ni1000 Accuracy Measuring range 0.+1820 -270.+1000 -210.+1200 -270.+1372 50.+1768 50.+1768 -270.+ -270.+1300 0.+2315 0.+2315 -200.+ -200.+ -200.+ -200.+ 60.+ 60.+ 0.500 0.4000 -100 mV.+1200 mV.+ ASTME 43710 751; JIS; SAMA1) 4-wire 437602) 4-wire 0.00618) Resistance, 4-wire Voltage 32.+3308 (-454.+1832 (-346.+2192 (-454.+2502 58.+3215 58.+3215 (-454.+ (-454.+2372 32.+4200 32.+4200 (-328.+1652 (-328.+1112 (-328.+1562 (-328.+1562 76.+ 76.+ 0.00385; 0.003916; SAMA 0.003902 Edison Curve No.7 Ni120 Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus (RTD), thermocouples, independent channels 10/11-8.25 General characteristics Response time Vibration resistance Vibration operation Resistance shock Electrical isolation (I/O) Long-term stability acc. 68T.2-6 acc. 68T.2-27 Influences Influence ambient temperature resistance measurement 0.500 0.4000 Thermocouple type voltage measurement -100 mV.+1200 mV.+ 0.025 K/10 m/10 m/10 0.025 K/10 µV/10 µV/10 Characteristics rated conditions acc. (related Measuring error incl. characteristic deviation resistance measurement 0.500 0.4000 Thermocouple type voltage measurement -100 mV.+1200 mV.+ Additional influence internal ref. junction Pt100 0.25 Environment conditions Ambient temperature range -40.+85 Transport storage temperature -40.+100 Relative humidity (100 humidity with isolated terminals only) Condensation permitted Mechanical construction Dimensions dimensional drawing Weight Housing material Polycarbonat Color (Epoxy) black (Non-Ex type), blue (Ex-type) Terminals, pluggable mm2, screw terminals (stainless steel screws) Parameterization structure Type input independent channels), measuring range, input filter, damping, alarm function, limit values, safing data proof against mains failure Standard parameter (factory settings) Channel Pt100, 4-wire circuit, 0.+100 damping unit Channel disabled Electromagnetic compatibility (EMC) According NAMUR recommendation With Pt100 sensor thermocouple Type test Burst signal/ data lines Static disgarge contact discharge contact plate terminals radiated field MHz.2 coupling Degree Standard 61000-4-4 61326 61000-4-2 61000-4-3 61000-4-6 Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus (RTD), thermocouples, independent channels 10/11-8.25 Explosion protection Intrinsically safe Certificate ATEX (Intrinsically safe Zone Mine) Zone Zone Zone T1.T5 Ambient temperature: -20.+60 Ambient temperature: -20.+50 T1.T4 Ambient temperature: -40.+85 Ambient temperature: -40.+65 Ambient temperature: -40.+50 Ambient temperature: -20.+60 sparking "nA" ATEX Certificate Zone (TF02-Ex [nL] T1.T4 Ambient temperature: -40.+85 T1.T5 Ambient temperature: -40.+65 T1.T6 Ambient temperature: -40.+50 Canadian Standards Association Factory Mutual Intrinsically Safe Class Class Class Class Class Div. 1/Div. Groups Zone Zone Div. 1/Div. Groups Div. Groups Div. Groups Mine Supply communication circuit ia/ib Max. voltage Short-circuit current Max. power 2.52 Internal inductance Internal capacitance Supply circuit Supply communication circuit ia/ib 5.32 Measuring circuit ia/ib Nonincendive neglectable Suitable connceting systems according Entity model FISCO model Block diagram Value_1 (T1) Sensor (T1) Block value sensor Status Value_2 (T2) Transducer Block Block value sensor Status Reference junction Pt100 Sensor (T2) Resource Block request only read request read/write Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus (RTD), thermocouples, independent channels 10/11-8.25 Connection diagram Output Microprocessor Input Foundation Fieldbus (H1) Reference junction Resistance thermometer, 2-wire circuit Resistance thermometer, 3-wire circuit Resistance thermometer, 4-wire circuit Double resistance thermometer, 2-wire circuit (average value differential temperature measurement) Potentiometer input (4-wire circuit) Resistance measurement analogous resistance thermometer circuits Thermocouple Double thermocouple (average value differential temperature measurement) Combination thermocouple resistance thermometer Voltage measurement Double voltage measurement (average value differential temperature measurement) Voltage measurement resistance measurement analogous circuit also possible Dimensional drawing (dimensions 44,4 Snap-on fixing rail mounting(35mm) (optionally) 23,8 Automation Products Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus (RTD), thermocouples, independent channels 10/11-8.25 Ordering information Catalog TF02/TF02-Ex V11527Bus system FOUNDATION Fieldbus (H1) acc. Fieldbus standard IEC-61158-2; 31.25 kbit/s functionality standard functionality among using combination with FIO100 800HSE from Explosion protection (without explosion protection) TF02 Type protection: Sparking "nA" ATEX DMT/ATEX TF02-Ex Zone [nL] Type protection: intrinsically safe ATEX DMT/ATEX TF02-Ex Zone Mine: Type protection: intrinsically safe TF02-Ex Class Div. 1/Div. Groups Class Zone oder (Class Groups Class built BUZH head AGLH head) nonincendive, Class Div. Groups (Class Groups Class built BUZH head AGLH head) Class Div. Div. Groups TF02-Ex (Class Groups Class built BUZH head AGLH head) nonincendive, Class Div. Groups A,B,C,D (Class Groups Class built BUZH head AGLH head) Construction Module Module with sensor connecting line Module with snap-on fixing Module built into connection head with sensor connecting line BUZH head BUSH head BUKH-Ex head AUZH head AUSH head AGLH-head without display Attention: sensor connecting lines correspond order type sensor type circuitry Connections head selected with cable screw connections cable screw connection Programming Factory standard parameter 100, 4-wire circuit, channel, 0.100°C, Damping Customer-specified parameter definition (all parameter without user curve) Deliv. time wks. 424,00 455,00 455,00 455,00 455,00 7,62 10,00 41,30 41,80 33,60 55,20 56,40 63,60 19,40 35,90 Accessories Simulation plug TF02/TF202 with system FOUNDATION Fieldbus Catalog 7957851 Deliv. time 12,20 protective pipe connection (optional 1.5; 1/2" NPT; 3/4" NPT) Standard: Aluminum, metal-cable-screw-connection (cable diameter 3.5.8.7 mm); applications, data sheet 10/10-3.28 details) IndustrialIT wordmark mentioned product names form XXXXXXIT registered pending trademarks ABB. Sales Customer Support expertise over countries worldwide. www.abb.com Company's policy continuous product improvement right reserved modify information contained herein without notice. Printed Fed. Rep. Germany (05.04) 2004 Ltd. Salterbeck Trading Estate Workington, Cumbria, CA14 Tel: +44(0)1946-830-611 Fax: +44(0)1946-832-661 Inc. County Line Road Warminster, 18974 Tel: 215-674-6000 Fax: 215-674-7183 Automation Products GmbH Borsigstr. 63755 Alzenau Germany Tel: 905-534 Fax: 905-555 CCC-support.deapr@de.abb.com 10/11-8.25 Rev. Other recent searchesSPN09T10 - SPN09T10 SPN09T10 Datasheet SIR136 - SIR136 SIR136 Datasheet NJM2644 - NJM2644 NJM2644 Datasheet NJM2644M - NJM2644M NJM2644M Datasheet NJM2644RB1 - NJM2644RB1 NJM2644RB1 Datasheet IRF3515S - IRF3515S IRF3515S Datasheet IRF3515L - IRF3515L IRF3515L Datasheet CDAE-279-001 - CDAE-279-001 CDAE-279-001 Datasheet BUL6822BL - BUL6822BL BUL6822BL Datasheet 1945203 - 1945203 1945203 Datasheet
Privacy Policy | Disclaimer |