10/11 8.19
FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex
HART programmable, (RTD), thermocouples, electrical isolation
Level Information
Input Resistance thermometer wire circuit) Thermocouples Resistance remote signalling unit (0.5000 Voltages, (-125.+1200 Output wire technique 4.20 HART signal Electrical isolation (I/O) Measured error Customer-specific linearization points Continuous sensor self-monitoring Parameter saved permanently EEPROM Monitoring data integrety every Wire break monitoring acc. with NAMUR Substitution strategy case error Approvals explosion protection Intrinsically safe [ia] mount zone mount zone Input functionality (absolute, differential, average value) acc. 50082-2 Parameterization Device Management Tool: SV401 (SMART VISION) Hand held terminals: 691HT, STT04, HHT275 CoMeter (HART configurator/LC display) years warranty
Excellent long term stability Temperature linear output signal Enhanced self diagnostics
Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, (RTD), thermocouples, electrical isolation
10/11 8.19
Technical data
Output
Output signal (temperature linear) 4.20 Residual ripple (peak-to-peak) Current consumption Maximum output current 23.6 Parameterizable current error signal Underranging Overranging Default value 3.6.23.6 Damping 0.30
Sensor short-circuit (for RTD) Sensor break (temperature/resistance measurement wire) Measuring range Measuring range 0.5000 Sensor wire break monitoring accordance with NAMUR Sensor wire break detection wire resistance measurement wire resistance measurement Input filter 50/60
Thermocouples
Types Voltages mV.+ mV.+1200 Minimum measuring span mV/50 Sensor wire break monitoring accordance with NAMUR Pulsed with outside measuring interval Monitoring disconnectible Thermocouple measurement Voltage measurement Input filter 50/60 Internal reference junction 100, software switchable jumper necessary)
Input
Resistance
Resistance thermometer (IEC 751, JIS, SAMA) 100/Ni 1000/Ni 1000; 0.1, 0.2, 0.5, 1.2, 3.10) Min. measuring span K/50 Resistance 0.500 /0.5000 Min. measuring span Maximum line resistance (Rw) core wire Measuring current
Input element Standard Sensor Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Thermocouple type Resistance thermometer Resistance thermometer 1000 Resistance thermometer Resistance thermometer
Measuring range 250.+1820 -250.+1000 -210.+1200 -250.+1372 50.+1768 50.+1768 -200.+ -200.+1350 (+482.+3308 (-418.+1832 (-346.+2192 (-418.+2502 58.+3215 58.+3215 (-328.+ (-328.+2462
Min. measuring span (423 (308 (348 (108
43710 751; JIS; SAMA1) wire 437602) wire Resistance Voltage
-200.+ 76.+ -200.+ (-328.+1112 -200.+ (-328.+1562 -200.+ (-328.+1562 60.+ 76.+ 60.+ 76.+ 0.500 /0.5000 -125 mV.+ -125 mV.+1200
0.00385, 0.003916, SAMA 0.003902 Edison Curve
Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, (RTD), thermocouples, electrical isolation
10/11 8.19
Power supply (poling protected)
Supply voltage application 8.5.30 Application, max. 8.5.29.4 wire methode: power supply wires signal wires Influence supply voltage 0.05 %/10 maximum residual ripple
Mechanical construction
Dimensions Confer dimensional drawing Weight Housing material Polycarbonat black (Non type) blue type)
Power demand indicators (only with AGLHD head)
(Power demand transmitter indicator have added)
Digital indicator CoMeter (HART configutor/LC display)
Electrical connection
Terminals, pluggable mm2, screw terminals (stainless steel screws)
Characteristics rated conditions
According (related °C)1)
Digital measured error Thermocouples Linear resistance /5000 Linear voltage mV/1200 measured error 0.05 measuring span Additional influence internal reference junction
Maximum load
smax smin -23.6
m/200 µV/50
Maximum permissible load
With CoMeter
Influences
Influence ambient temperature 100/resistance measurement2)
(HC)
11,4 14,4 17,3
Z-20160
Power supply
0.05 0.008 Thermocouple/mV3)
General characteristics
Output signal refreshment rate (Input signal change 0.25 K/s) Thermocouples (Input signal change K/s) Vibration resistance Vibration operation Resistance shock Electrical isolation (I/O) Long-term stability p.a. acc. 68T.2 acc. 68T.2
0.14 0.05 0.01 Percentage related measuring span lower range value, upper range value
Percentage related measuring span Specified values corresponds (Gaussian normal distribution) (0.400 °C): Influence ambient temperature (0.05 0.013 %)/10 0.063 %/10 Type (0.1000 °C): Influence ambient temperature (0.05 0.01 0.014 %)/10 0.074 %/10
Environment conditions
Ambient temperature range 40.85 Transport storage temperature 40.100 Relative humidity (100 humidity with isolated terminals only) Condensation Permitted
Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, (RTD), thermocouples, electrical isolation
10/11 8.19
Explosion protection
Intrinsically safe
Zone Marking Type Examination certificate Temperature class T6/T5/T4 Supply circuit Max. voltage Short circuit current Max. power Internal inductance Internal capacitance Output [ib] 29.4 [ia] ATEX 2139 °C/65 °C/85 Input [ia] mA4) 1.55
Electromagnetic compatibility (EMC)
100: measuring range 0.100 span Type test Burst signal/ data lines Static discharge Contact plate (indirect) Terminals supply5) Terminals sensors5) Radiated field MHz.1 Coupling Degree Influence 1000 1000 influence influence influence 1000 1000
According NAMUR recommendation. case input signal change 0.25 Pt100 thermocouples measured value plausibility check performed.
Zone Marking Conformity statement Temperature class T6/T5/T4
ATEX 2216 °C/65 °C/85
discharge distance)
Canadian Standards Association Factory Mutual
Intrinsically Safe Class Div. Groups Class Zone Group Class Div. Div. Groups Class Zone Group (Class Groups Class build BUZH oder AGLH Kopf) Class Div. Groups Class Div. Groups A,B,C,D (Class Groups Class wenn einge baut BUZH oder AGLH Kopf)
Nonincendive
supplement ATEX 2139
Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, (RTD), thermocouples, electrical isolation
10/11 8.19
Displays (option conjunction with AGLHD head)
Digital display
Digital display
Process value, sensor value loop current value indicator through current loop display: digits 1999), digit height segments Standard scaling 0.100 Linear scaling measuring ranges units possible Description physical unit (labels)
CoMeter (HART configurator display)
CoMeter (HART configurator display)
function keys request programming (Code protection) through current loop display: digits 1999), digit height segments Sign floating point segment bargraph (heading measuring range) digits alphanumeric characters segments Dual function HART transmitter programming unit (all HART functions except freely configurable characteristic curve Number) Process value, sensor value loop current value indicator Request function Process variable, analog display value, description measuring point, serial number, error behaviour, lower/upper measuring range limit Change function Sensor type,sensor circuit, measuring range, damping, mains filter, error signalling Special function Zero point adjustment, simulation output signal, adjustment output signal, calibration
Display Response time Measuring error Overvoltage maximum current Temperature Humidity Digital display CoMeter 0.15 input range 50082 20.+70 0.100 condensating permitted
Mind limits application
Communication/parameterization
Hand held terminal 691HT, STT04, HHT275 CoMeter Hart conigurator display Device Management Tool SV401 (SMART VISION) Parameter Sensor type, error signalling, measuring range, general characteristics number), damping, signal simulation output Software interface AMS, Cornerstone
CoMeter
Processinterface Line resistance
(250 min.)*
Isolators Controller Recorders
691HT, STT04, HHT275
Z-20162d
(optional) Modem
necessary
Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, (RTD), thermocouples, electrical isolation
10/11 8.19
Connection diagram
Microprocessor
Input
8,5.30
Output
4.20
Reference junction
Resistance thermometer, wire circuit Resistance thermometer, wire circuit Resistance thermometer, wire circuit Double resistance thermometer, wire circuit (average value differential temperature measurement) Potentiometer input, wire circuit
Thermocouple Double thermocouple (average value differential temperature measurement) Voltage measurement Double voltage measurement (average value differential temperature measurement)
Dimensional diagram (dimensions
Automation Products Contrans
Z-18763h
22,5
Z-20165
Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, (RTD), thermocouples, electrical isolation
10/11 8.19
Ordering information
Catalog TH02/TH 02-Ex V11518(without TH02 Type protection: intrinsically safe ATEX [ia]ib TH02-Ex Zone ATEX TH02-Ex Zone TH02-Ex Class Div. Groups Class Zone Group TH02-Ex Class Div.1 Div. Groups (Class Groups Class build BUZH head, head AGLH head) Nonincendive, Class Div. Groups (Class Groups Class built BUZH head, head AGLH head) TH02-Ex nonincendive, Class Div. Groups Construction display Module 22.5 Module 22.5 with sensor connecting line Module 22.5 with snap-on fixing Module 27.5 mounting measuring module Module built into connection head cover with sensor connecting line BUZH head BUSH head BUKH-Ex head Raised B-head cover head (completely head with raised cover) AUZH head AUSH head head1) without display AGLHD head1) with digital display AGLHD head1) with cometer Attention: sensor connecting lines correspond order type sensor type circuitry Module built into field housing: Aluminium field housing Polyester field housing Aluminium field housing 1.5; with separate terminal block Polyester field housing 1.5; with separate terminal block Notice: Other field housings with several transmitters specially pipe mounting request. Programming Factory standard parameter 100, 0.100 wire circuit, damping off, direct action characteristic overranging sensor device error Customer-specific parameter setting (questionnaire) without Calibration certificates point point 220,50 247,80 247,80 247,80 247,80 Deliv. time wks.
247,80 7,40 9,70 5,40 40,10 40,60 32,60 19,20 22,90 53,60 54,80 77,80 254,10 298,00
70,40 73,00 86,40 94,50
21,50 75,60 107,10
Accessories
modem [EEx (parameter setting installation) Device Management Tool SV401 (SMART VISION) TH02 /-102 /-202 driver software (Rosemount)2)
Catalog Data Sheet 10/63-6.71 Data Sheet 10/63-1.20 7957771
Deliv. time
107,10
Standard: Aluminium, metal-cable-screw-connection protective pipe connection (optional 1.5; 1/2" NPT; 3/4" NPT); applications, data sheet 10/10-3.28 details) already integrated software version higher Notice: lokal programming desk used Hardware universal FSK-Programming-Set (without Parasoft) (see Data Sheet 10/63-6.71 ordering information)
IndustrialIT wordmark mentioned product names form XXXXXXIT registered pending trademarks ABB. Sales Customer Support expertise over countries worldwide. www.abb.com
Company's policy continuous product improvement right reserved modify information contained herein without notice. Printed Fed. Rep. Germany (10.02) 2002
Ltd. Salterbeck Trading Estate Workington, Cumbria CA14 Tel: (0)1946 Fax: (0)1946
Inc. County Line Road Warminster, 18974 Tel: 6000 Fax: 7183
Automation Products GmbH Borsigstr. 63755 Alzenau Germany Tel: 6023 Fax: 6023 3430
10/11 8.19 Rev.

Other recent searches


uPD16804 - uPD16804   uPD16804 Datasheet
SR315 - SR315   SR315 Datasheet
NL6448AC30-12 - NL6448AC30-12   NL6448AC30-12 Datasheet
FTLX1412M3BTL - FTLX1412M3BTL   FTLX1412M3BTL Datasheet
DTB114TK - DTB114TK   DTB114TK Datasheet
DRC4124T - DRC4124T   DRC4124T Datasheet
BA6817F - BA6817F   BA6817F Datasheet
BA6818FS - BA6818FS   BA6818FS Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive