10 / 11-8.17 EN


FieldIT Head mounted Temperature Transmitter TS02 / TS02-Ex

Data Sheet
10 / 11-8.17 EN
FieldIT Head mounted Temperature Transmitter TS02 / TS02-Ex
programmable, Pt 100 (RTD), thermocouples, electrical isolation
Input - Resistance thermometer (2-, 3-, 4-wire circuit) - Thermocouples - Resistance remote signalling unit (0..5000 ) - Voltages, mV (-125..+1200 mV) Output - 2-wire technique - 4..20 mA, digital signal Electrical isolation (I / O) between input and output Digital low drift processing of measurement values Customer specific linearization - 64 tie points Continuous sensor and self-monitoring - Parameter saved permanently in EEPROM - Monitoring of data integrety every 10 s Substitution strategy in case of error (NE 43) Approvals for explosion protection - intrinsically safe II 2 (1) G EEx iaib IIC T6, mount in zone 1 II 3 G EEx n A II T6, mount in zone 2 Input functionality (absolute, differential, average value) EMC acc. to EN 50082-2 and NE 21 CE conformable Parameterization - Device Management Tool: DSV401 (SMART VISION) - Parasoft 5 years warranty
Head mounted Temperature Transmitter TS02 / TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation
10 / 11-8.17 EN
Technical data
Output
Thermocouples
Types B, E, J, K, L, N, R, S, T, U Voltages -125 mV..+125 mV -125 mV..+1200 mV Min. span 2 mV / 50 mV Sensor monitoring current 70 nA Input filter 50 / 60 Hz Internal reference junction Pt 100, via software switchable (no jumper necessary)
Input
Resistance
Resistance thermometer Pt 100, Pt 200..Pt 1000 Ni 100, Ni 500 min. span: 20 K (15 K) Resistance 0..500 / 0..5000 min. span: 5 / 50 Input element Standard IEC 584-1 Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N Thermocouple type L Thermocouple type U Resistance thermometer Pt 100 Resistance thermometer Pt 1000 Resistance thermometer Ni 100 Resistance thermometer Ni 500 mV
Measuring range 250..+1820 °C -250..+1000 °C -210..+1200 °C -250..+1372 °C - 50..+1768 °C - 50..+1768 °C -200..+ 400 °C -200..+1350 °C -200..+ 900 °C -200..+ 600 °C -200..+ 850 °C -200..+ 850 °C - 60..+ 250 °C - 60..+ 250 °C (+482..+3308 °F) (-418..+1832 °F) (-346..+2192 °F) (-418..+2502 °F) (- 58..+3215 °F) (- 58..+3215 °F) (-328..+ 752 °F) (-328..+2462 °F) (-328..+1652 °F) (-328..+1112 °F) (-328..+1562 °F) (-328..+1562 °F) (- 76..+ 482 °F) (- 76..+ 482 °F) 2 mV 50 mV
Min. measuring span 235 °C 30 °C 37 °C 54 °C 171 °C 193 °C 50 °C 61 °C 36 °C 40 °C 15 °C 50 °C 8 °C 15 °C 5 / 50 (455 °F) ( 86 °F) ( 98 °F) (129 °F) (339 °F) (379 °F) (122 °F) (141 °F) ( 96 °F) (104 °F) ( 59 °F) (122 °F) ( 46 °F) ( 59 °F)
DIN 43710 IEC 751 JIS MIL1) 2-, 3- and 4-wire DIN 437602) 2-, 3- and 4-wire Resistance Voltage
0..500 / 0..5000 -125 mV..+ 125 mV -125 mV..+1200 mV
Head mounted Temperature Transmitter TS02 / TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation
10 / 11-8.17 EN
Power supply
Mechanical construction
Dimensions see dimensional drawing Weight 55 g Housing material Polycarbonat Color (Epoxy) black (Non Ex type) blue (Ex type)
Power demand of indicators (only with AGLHD head) (Power demand of transmitter and indicator have to be added)
Electrical connection
Terminals 2.5 mm2, screw terminals (stainless steel screws)
Characteristics at rated conditions
Maximum load
Maximum permissible load R
With ProMeter
Influences
Z-20155-2
V DC Supply voltage
General characteristics
Environment conditions
Head mounted Temperature Transmitter TS02 / TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation
10 / 11-8.17 EN
Explosion protection
Intrinsically safe
Zone 1 Marking EC certificate Temperature class T6 / T5 / T4 Supply circuit Max. voltage Short-circuit current Max. power Internal inductance Internal capacitance
Electromagnetic compatibility (EMC)
Pt 100: measuring range 0..100 °C, span 100 K Type of test burst to signal / data lines static discharge contact discharge to: contact plate terminals for supply2) terminals for sensors2) radiated field 80 MHz..1 GHz coupling 150 kHz - 80 MHz
Degree 3 kV
IEC 1000-4-4 1000-4-2
no effect no effect no effect 1000-4-3
Air discharge (1 mm distance)
Zone 2 Marking Conformity declaration Temperature class T6 / T5 / T4
GOST Standard
Marking EEx ia ib IIC T6
Canadian Standards Association and Factory Mutual
Intrinsically Safe FM / CSA FM CSA Nonincendive FM / CSA Class I, Div. 1, Groups A, B, C, D, T6 Class II, Div. 1, Groups E, F, G, T6 Class III, T6 Class I, Zone 1, AEx ia ib IIC T6 Class I, Zone 1, Ex ia ib IIC T6 Class I, Div. 2, Groups A, B, C, D, T6 Class II, Div. 2, Groups F, G, T6 Class III, T6
Communication / parameterization
Device Management Tool DSV401 (SMART VISION) Parameter Sensor type, error signalling, measuring range, general characteristics (i. e. TAG number), damping, signal simulation of output
Processinterface Line resistance
(250 min.)
or Isolators Controller Recorder ..
Software DSV401 (SMART VISION) or Parasoft
Z-20162b
FSK Modem
(optional)
if necessary
Head mounted Temperature Transmitter TS02 / TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation
10 / 11-8.17 EN
Connection diagram
Microprocessor
Input
Output
4..20 mA
Reference junction
a) Resistance thermometer, 2 wire circuit b) Resistance thermometer, 3 wire circuit c) Resistance thermometer, 4 wire circuit d) Double resistance thermometer, 2-wire circuit (average value or differential temperature measurement) e) Potentiometer input (4 wire circuit)
f) Thermocouple g) Double thermocouple (average value or differential temperature measurement) h) Voltage measurement (average value or differential temperature measurement) i) Double voltage measurement (average value or differential temperature measurement)
Dimensional diagram (dimensions in mm)
Automation - Products Contrans TS 02
Messumformer / Transmitter / Transducteur
Snap-on fixing for DIN rail mounting (35 mm), (optionally)
Z-18763
Z-20165
Head mounted Temperature Transmitter TS02 / TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation
10 / 11-8.17 EN
Display (Option, only in conjunction with AGLHD head)
Analog display
ProMeter
Display Response time Measuring error Max. current EMC Temperature operating range Humidity
Mind limits of application
ESC key
ENTER key
Bargraph for analog output indication
NEXT key
ProMeter
PREV key
Configuration menu
Anzeige
ENTER ESC NEXT PREV ESC NEXT PREV ESC NEXT PREV ESC NEXT PREV
ConF MANUAL
ESC ENTER NEXT PREV
ConF CURRENT
ESC ENTER
ConF PERCENT
ESC ENTER
ConF PASSWD
NEXT PREV
ENTER
NEXT PREV
ENTER
ENTER ENTER
SET 4..20 mA INDICATION
NEXT PREV
LINEAR SQR
ENTER
NEXT PREV
04000 04000 04000 00000 00000 ZERO
ENTER
20000 20000 20000 20000 20000 FULL SC
ENTER
KPA TORR A MPA IN H2O
ENTER
OUTPUT
LINEAR SQR
ENTER
UPDATE NEW PASSWORD
Note: When using the ProMeter for process value or sensor value indication, its zero and full scale programming must be in accordance with the transmitter temperature range or sensor range.
ENTER
4000 ZERO
NEXT PREV
20000 FULL SC
NEXT PREV
UNITS
00000 01000 01200 01230 01234 PASSWD
Head mounted Temperature Transmitter TS02 / TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation
10 / 11-8.17 EN
Ordering information
Head mounted Temperature Transmitter TS02 / TS02-Ex programmable, Pt 100 (RTD), thermocouples, electrical isolation
10 / 11-8.17 EN
Accessories
TS02 / TS102 / TS202 programming set NHA102-NX, parameterization in hazardous area HART-FSK Modem II-Ex (sep. transmitter supply required) Electrical isolation, IS input EEx ib II C, incl. connection lead 4 / 2 mm and 4 / 4 mm Device Management Tool DSV401 (SMART VISION) 1) 1) Catalog No. see Data Sheet 10 / 63-6.71 EN see Data Sheet 10 / 63-6.71 EN EUR Deliv. time
see Data Sheet 10 / 63-1.20 EN
1) The programming set consists of head mounted transmitter adapter with 250 Ohms load, power supply and modem. Two adapter cables will be delivered in addition for connection with rail mounted transmitters TS102, TH102 and other HART devices Note: The universal programming set with software DSV401 (SMART VISION) can be used for local programming of the TS02 / TS102 / TS202 devices, but also for programming of HART devices, for example TH02 / TH102 / TH202 ..
The IndustrialIT wordmark and all mentioned product names in the form XXXXXXIT are registered or pending trademarks of ABB. ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com
ABB Ltd. Salterbeck Trading Estate Workington, Cumbria, CA14 5DS UK Tel: +44 (0)1946-830-611 Fax: +44 (0)1946-832-661
ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215-674-6000 Fax: +1 215-674-7183
ABB Automation Products GmbH Borsigstr. 2 63755 Alzenau Germany Tel: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com
10 / 11-8.17 EN Rev. B