| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Field mounted Temperature transmitters, analog, (RTD), fixed measuring
Top Searches for this datasheet204-Ex Field mounted Temperature transmitters, analog, (RTD), fixed measuring ranges 10/11-8.59 Input Resistance thermometer 3-wire circuit) optionally 4-wire circuit Approvals explosion protection intrinsically safe pressure-proof mount zone mount zone mount zone Output 2-wire methode 4.20 Digital, drift processing measuring values Error signalization sensor break sensor short-circuit acc. 50082-2 years warranty 204-Ex Field mounted temperature transmitters, analog Technical data Output Output signal (temperature linear)4.20 Output current, max. Underranging Overranging 2.5.< 10/11-8.59 Power supply (2-wire methode) Supply voltage (protected against wrong polarity) 10.5.30 explosion protection application, max. Influence supply voltage max. residual ripple (IEC 751) -200 °C.850 ordering information (3-wire, 4-wire) %/10 (3-wire, 4-wire) additionally (2-wire) Maximum permissible load .29.4 0.05 %/10 (peak-to-peak) Input Resistance Resistance thermometer Measuring ranges min. span Sensor lead resistance (max.) Sensor lead influence Sensor lead influence 100-measuring current Maximum Load Usmax Usmin Power demand indicator (Power demands transmitter indicator have added) Analog indicator Digital indicator Sensor break monitoring Overranging, (standard) Break Underranging, (optionally) Break With digital display Sensor short-circuit monitoring, underranging short circuit Lower range value Upper range value Measuring span Percentage related span 10,5 12,5 Z-20155a Supply voltage Display (optionally) Analog indicator Clearly arranged display scale Available scalings: 0.100 linear (special scalings request) Digital indicator display digits 1999), digit height segments standard scaling 0.100 Linear scaling measuring ranges dimensions possible Description physical unit (labels) Display Rise time Measuring error Overvoltage Temperature Humidity Mind limits application. Analog Digital input range 50082-2 -20.+70 0.100 condensation permissible Page 03.2000 204-Ex Field mounted temperature transmitters, analog Technical data General characteristics Response time 3-wire 4-wire Vibration resistance Vibration operation Long-term stability acc. part. %/year Supply circuit Max. voltage -40.85 Output 29.4 neglectable 10/11-8.59 Explosion protection Intrinsically safety Zone certificate Temperature class T6/T5/T4 ATEX 2053 °C/65 °C/85 Input mA3) ATEX 2215 °C/65 °C/85 ATEX 1144 50°C/65 °C/85 Environment conditions Ambient temperature range Transport- storage temperature-40.100 Relative humidity (100 humidity with isolated terminals only) Condensation permissible Short-circuit current Max. power Internal inductance Internal capacitance neglectable Zone Load current connected intrinsically safe primary element Mechanic design Dimensions Weight Housing (material) Degree protection Color (Epoxy) Electrical connections Thread pcs. pcs. 1/2" NPT, pcs. 3/4" pcs. (metal) mm2, screw terminals dimensional diagram (without accessories) aluminium/stainless steel light grey (RAL 9002) Conformity declaration Temperature class T6/T5/T4 Pressure-proof enclosure certificate Temperature class T6/T5/T4 Canadian Standards Association Factory Mutual preparation) with cable screw connections Ground screw ext./int. Terminals Intrinsically Safe FM/CSA Class Div.1/Div.2, Group Class Div.1/Div.2, Group Class Class Zone Class Zone Non-incendive FM/CSA Class Div.2, Group Class Div.1/Div. Group Class Explosionsproof FM/CSA Class Div.1/Div.1, Group Class Div.1/Div. Group Class Flameproof Class Zone Class Zone Characteristics rated conditions1) (acc. (related °C)) Measuring error incl. characteristic deviation 100/resistance measurement Balancing error Spans Spans <100 Linearity error 0.15 0.10 Influences Ambient temperature influences (whichever value greater) Electromagnetic compatibility (EMC) 100: measuring range 0.100 span 3-wire acc. NAMUR recommendation Type test burst signal/ data lines static discharge contact discharge contact plate terminals supply terminals sensors radiated field MHz.1 coupling Degree Influence 1000-4-4 1000-4-2 1000-4-3 1000-4-6 Example: Balancing error (0.1 Percentage related measuring span lower range value, upper range value 03.2000 Page 204-Ex Field mounted temperature transmitters, analog Ordering information Catalog V11521TR 204-Ex (without explosion protection) Type protection: intrinsically safe ATEX (zone 204-Ex Class Div. Group A,B,C,D 204-Ex Class Div. Div. Group E,F,G Class Class Zone Class Zone (zone2) 204-Ex ATEX Class Div. Group A,B,C,D, noninc. Class Div. Group E,F,G, Class Type protection: pressure-proof enclosure explosion-proof 204-Ex ATEX Class Div. Div. Group A,B,C,D, 204-Ex Class Div. Div. Group E,F,G, Class Type protection: flameproof Class Zone 204-Ex Class Zone AGLF housing without display Display construction AGLFH housing (raised cover transmitters AGLFD housing with analog indicator AGLFD housing with digital indicator Aluminium Material Stainless steel pieces: 1,51 Connections with cable-screw-connections pieces: pressure-proof1 Thread (without screw connection) 1/2" 3/4" 1/2" without Mounting field housing Wall mounting (STT37) Wall mounting (stainless steel) Pipe mounting (STT Pipe mounting (stainless steel) Standard measuring ranges °C.60 Measuring ranges °C.40 °C.40 °C.60 °C.100 °C.120 °C.150 °C.200 °C.250 °C.300 °C.400 °C.600 Standard meas. range Special meas. range (span (span Sensor circuit 2-wire 3-wire optional: 4-wire Sensor break idendification: sensor braek overranging 22mA, standard version) sensor break underranging 3mA, optional) without Calibration certificates Two-point calibration certificate 9-point calibration certificate metal-screw-connection bzw. (cable-diameter 509,00 579,00 579,00 10/11-8.59 LZ/deliv. 579,00 579,00 579,00 579,00 35,00 149,00 299,00 A./o.r. 60,00 75,00 0,00 30,00 55,00 60,00 95,00 40,00 40,00 80,00 0,00 50,00 140,00 200,00 Page 03.2000 204-Ex Field mounted temperature transmitters, analog Connection diagram 10/11-8.59 10,5.30 Output Signal conditioning Input 4.20 Z-20187 Resistance thermometer, 2-wire circuit Resistance thermometer, 3-wire circuit Resistance thermometer, 4-wire circuit (optional) Dimensional drawings (dimensions AGLFD housing +123.4 Electrical connections AGLF housing Electrical connections 03.2000 Lockscrew Thread Thread Potential equalisation screw Z-20161 Page Automation Products GmbH Sensycon Alzenau D-63755 Alzenau Tel. http://www.abb.com/automation Subject technical changes. Printed Fed. Rep. Germany Data sheet 10/11-8.59 03.2000 Other recent searchesTN2404K - TN2404K TN2404K Datasheet TN2404KL - TN2404KL TN2404KL Datasheet BS107KL - BS107KL BS107KL Datasheet TDA7052B - TDA7052B TDA7052B Datasheet RGP02-12E - RGP02-12E RGP02-12E Datasheet OD-50W - OD-50W OD-50W Datasheet HHM1545 - HHM1545 HHM1545 Datasheet EN485 - EN485 EN485 Datasheet RS485 - RS485 RS485 Datasheet 2SK3403 - 2SK3403 2SK3403 Datasheet
Privacy Policy | Disclaimer |