The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Chameleon Adaptable Module General Medical Applications Recognize


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Series
Chameleon Adaptable Module General Medical Applications
Recognized Certified Approved
Unfiltered
Filtered
Series
series power entry module offers full flexibility design most compact package. first module provide five power entry functions compact design, "Chameleon" readily adapts environment needs international markets. Snap-in flange mounting power line connector Both North American European fusing capabilities voltage selection Optional DPST on/off switch Filtering options general purpose medical applications. Chameleon's compact design modular construction will allow select power entry features require without altering panel cutout. Chameleon, with adapters, will standard panel cutout currently have designed. Chameleon filter options. models offer protection general purpose applications where line-toground line-to-line noise must controlled. filters designed meet leakage requirements portable equipment. They available current ratings amps. models provide susceptibility protection without leakage current associated with line-to-ground capacitors, designed allow equipment meet patient care nonpatient care equipment. Also available interconnection block, models. block connects voltage selection terminals unfiltered Chameleon with switch connector reduce external wiring.
filter with Shield
Libertyville, (847) 680-7400
Series
Series Part Number Schematic
Part numbers constructed selecting alphanumeric character which represents desired feature.
Mounting Style
Extender Options*
Switch Options
Voltage Select
Fuse Options
Filter Type
Filter Current
Shield Options
Mounting ears Snap-in
None FN260 Series series
Dual fuse Single fuse
shield Filter shield Complete shield
Blank Double pole single throw
filter Interconnection block Medical filter General purpose filter amps amps amps
Single voltage Dual voltage select (SMPS) Dual voltage select (series/parallel)
part number PSJ0XSS60 would represent equivalent Corcom's 6J4. part would feature extender current panel cutout, includes switch, dual voltage select, single fusing, general purpose filter.
Extender J-Series others
Pricing
Consult your local Corcom sales representative pricing.
Fuseholder
Part PS000S000 PS0SXS000 PS0S0SBX0 PS000SH30 PS00SDH3A PS0S0SH60 PS0SSDH6A PS00SSHXA PS0SSSHX0 PS000SS30 PS0S0SS30 PS0SSSS6B
Part PS0SXDS60 PSJ0XSS60 PSLS0SS60 PS0SXSS60 PS00SSSXA PSOSSSSX0 PE0SSS000 PE0SSSH60 PE000SS30 PE0S0SS30 PE000SS60 PE0SSSSX0
Optional switch
Optional filter
Additional extender which allows series adapt Corcom's series cutout, well panel cutout Schaffner Delta parts, available. *Extenders cannot added units with shields. When using interconnection block, last digits part number BXO.
Libertyville, (847) 680-7400
Series
Voltage Selection
series power entry modules provides dual voltage selector which integrated with fuseholder. simplify wiring each individual application, Corcom provides dedicated voltage selectors different voltage selection schemes. most popular schemes parallel serial dual primary transformers "SPST switch" switching mode power supplies (jumper types.) series products with fifth digit specifically designed "jumper" type applications associated with switching mode power supplies. series products with fifth digit specifically designed dual primary transformer applications. voltage selector installed will allow proper wiring from these applications. matter what voltage selection scheme used, wiring always made same four terminals.
Interconnection Block
Installation unfiltered versions series involves wiring socket switch switch fuseholder. Labor eliminated ordering product with interconnection block. This feature, designated seventh eighth digits, prewires module easier installation. wiring protected with plastic case prevent access terminals connections. Wiring further simplified ordering PA100 connector assembly. page accessories. dimensions this alternative same filtered versions.
Filter Options
filtering options available three current ratings. models (those with seventh digit) provide general purpose filtering both line-to-ground lineto-line noise. increased inductance series allows better performance than most power entry modules market. models will generally allow compliance with limits linear power supplies. models greatly reduce line-to-ground capacitance compliance with leakage current specification. Model
Fuseholder
Another feature series power entry module versatile fusing arrangement. fuseholder hold 1/4" 1-1/4" 20mm fuses. also converted accept fuse with conversion clip that bridges fuse chambers. conversion clip installed Chameleon power entry modules single fusing, those with part numbers with sixth digit. Units with sixth digit include conversion clip.
Model
Shield
feature available series shield. metal shield, available filtered models, provides shielding from radiated emissions provides additional ground filter case. Shield shield available options, shield filter components (designated ninth digit) complete shield (designated ninth digit). shield covers filter portion module increases performance filter protecting components from radiated noise. This shield improves ground connection case while still allowing Chameleon extender. shield covers entire power entry module with metal, protecting equipment from radiated noise. Used with filter, shield provides most secure protection from noise problems. shield cannot used with extender. Libertyville, (847) 680-7400
Shield
Series
Specifications Unfiltered Models
Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Rated voltage: Rated current, unfiltered models: Operating voltages: Selectable fixed Fuseholder: Accepts fuses Conversion clip provided fuseholder single fuse models. Switch Double-insulated rated 10,000 operations full load. inrush capability. Terminals: 0.187" 0.032" terminal tabs Terminals: 1/4" 1-1/4" 115/230 1500 1450 50/60 120/250
0.25mA .50mA
Specifications Filtered Models
Maximum leakage current, each line-to-ground: models models models models Hipot rating (one minute): line-to-ground line-to-line Operating voltages: Selectable fixed Operating frequency: Rated voltage:
1500 1450 115/230 50/60 120/250
Conversion clip provided fuseholder single fuse models. Switch: Double-insulated rated 10,000 operations full load. inrush capability. 0.187" 0.032" terminal tabs
Voltage Selection Schemes
Dual Primary Transformer Type:
115V Power on/off Note Ground Note Neutral Note Note Transformer primary Provision single fusing 115V 115V 230V
Minimum insertion loss Line-to-ground circuit Current Frequency-MHz Rating Models Models
Jumper Type
115V Power on/off Note Ground Note Neutral Note Provision single fusing Note SMPS Power input Sel. Jumpers 230V
Line-to-line circuit Current Frequency-MHz Rating Models Models
Note Jumpers required filter interconnection module used. Note Location optional filter. Jumpers required filter interconnection module used.
Libertyville, (847) 680-7400
Series
Case Dimensions Unfiltered Models
Metric shown italics. Part (max) (max) (max)
Case Styles
Metric shown italics.
PS/PSL Unfiltered
(+.008 -.000) (+.008 -.000)
1.98 1.93 2.31 1.122 50.29 49.02 58.67 28.5 1.24 1.93 2.31 1.06 31.49 49.02 58.67 26.93 1.24 1.93 2.81 1.06 31.49 49.02 63.75 26.92 1.24 1.93 2.72 1.06 31.49 49.02 69.09 26.92 1.24 1.93 2.31 1.12 31.49 49.02 58.67 28.45
2.201 1.575 55.91 40.0 2.201* 55.91 2.52 64.01 66.0 2.201* 55.91
Panel cutout thickness .031 .079 (.08 2.0). panel thickness .083-.114 (2.1-2.9) 2.213 (56.21).
Panel cutout thickness 0.06-0.09. 0.02R .508
PSC/PSJ Unfiltered
Panel Cutout
0.225 5.72
Panel Cutout
0.02R .508 .125 3.18
Mounting holes snap-in applications, sides cutout must have (.508) radius installation side.
Note: Snap-in models allow front mounting only. recommended plastic panels.
Dia.
Countersunk holes
Libertyville, (847) 680-7400
Series
Case Styles Filtered
Metric shown italics.
Case Dimensions Filtered
Metric shown italics. (max) (max) (max) 1.98 2.13 50.29 54.1 1.24 2.13 31.49 54.1 1.24 2.13 31.49 54.1 1.24 2.13 31.49 54.1 1.24 2.13 31.49 54.1
Part
(+.008 -.000) (+.008 -.000)
2.31 1.122 2.201 1.575 58.67 28.5 55.91 40.0 2.31 1.06 2.201* 58.67 26.93 55.91 2.51 1.06 2.52 63.75 26.92 64.01 2.72 1.06 2.6+ 69.09 26.92 66.0 2.31 1.12 2.201* 58.67 28.45 55.91
0.225 5.72 0.06R 1.52
Shielded Models
Panel cutout thickness .031 .079 (.08 2.0). panel thickness
0.020R .508
.083-.114 (2.1-2.9) 2.213 (56.21). Panel cutout thickness 0.06-0.09.
recommended with plastic panels.
shielded models 1.12 .000 Shields used only with filtered models. Shields approximately 0.06" depth. shield used with extender.
.008
PS/PE with Shield
0.225 .508
.225 5.72
Panel Cutout
PS/PE with Shield
snap-in applications, sides cutout must have (.508) radius installation side.
0.225 .508
easy wiring connection, accessories PA100 PA101 page 117.
Libertyville, (847) 680-7400

Other recent searches


Xilinx - Xilinx   Xilinx Datasheet
XAPP250 - XAPP250   XAPP250 Datasheet
Clock - Clock   Clock Datasheet
Data - Data   Data Datasheet
Recovery - Recovery   Recovery Datasheet
with - with   with Datasheet
Coded - Coded   Coded Datasheet
Data - Data   Data Datasheet
Streams - Streams   Streams Datasheet
Application - Application   Application Datasheet
Note - Note   Note Datasheet
SRA06102 - SRA06102   SRA06102 Datasheet
Si2328DS - Si2328DS   Si2328DS Datasheet
SED152A - SED152A   SED152A Datasheet
SED1521 - SED1521   SED1521 Datasheet
PS45SX-0305 - PS45SX-0305   PS45SX-0305 Datasheet
PLA140L - PLA140L   PLA140L Datasheet
MPC9817 - MPC9817   MPC9817 Datasheet
LQFP-44 - LQFP-44   LQFP-44 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive