The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Series Recognized Certified Approved Unfiltered PS000SS


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



CORCOM Product Guide CHAMELEON Adaptable Module General, High Performance Medical Applications
Series
Recognized Certified Approved
Unfiltered
PS000SS30
Filtered
Series
series power entry module offers fuller flexibility design more compact package. first module provide five power entry functions compact design, CHAMELEON module readily adapts environment needs international markets. Snap-in flange mounting power line connector Both North American European fusing capabilities voltage selections Optional DPST on/off switch Filtering options general purpose, medical high-performance applications. CHAMELEON modules compact design modular construction will allow select power entry features require without altering panel cutout. Chameleon module, with adapters, will standard panel cutout. CHAMELEON module four filter options. models offer protection general purpose applications where line-to-ground line-to-line noise must controlled. filters designed meet leakage requirements portable equipment. They available current ratings amps.
models provide susceptibility protection without leakage current associated with line-to-ground capacitors designed allow equipment meet patient care non-patient care equipment. Also available interconnection block, models. block connects voltage selection terminals unfiltered CHAMELEON module with switch connector reduce external wiring. Models High performance medical filter versions that designed help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level well part 15J, Class conducted emissions limits while additionally allowing equipment meet UL544, UL2601and EN60601 patient care equipment non-patient care equipment. They available with current ratings amps. High performance versions available with horizontal mounting ears, single voltage, complete shield with options switch, fuses current ratings only. Extenders available. Models High performance filter versions designed help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level well Part 15J, Class conducted emissions limits. They available with current ratings amps. High performance versions available with horizontal mounting ears, extenders, single voltage, complete shield with options switch, fuses current ratings only.
Filter with Shield
Tyco Electronics CORCOM Products
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
CORCOM Product Guide CHAMELEON Adaptable Module General, High Performance Medical Applications (Continued)
Series
Series Part Number Schematic
Part numbers constructed selecting alphanumeric character which represents desired feature.
Mounting Extender Style Options* Switch Options Voltage Select Fuse Options Filter Type Filter Current Shield Options*
Mounting Style Mounting ears (Horizontal) Snap-in Mounting ears (Vertical) Switch Option Blank Double pole single throw (DPST) Fuse Options Dual fuse Single fuse Filter Current filter amps amps amps
Power Entry Modules
part number PSJ0XSS60 would represent equivalent CORCOM Series 6J4. part would feature extender current panel cutout, includes switch, dual voltage select, single fusing, 6-amp general purpose filter.
Extender Option None FN260 Series Series
Input Voltage Select Single voltage Dual voltage select (SMPS) Dual voltage select (series/parallel)
Filter Type filter Interconnection block Medical Filter High Performance Medical General purpose High Performance
Shield Options shield Filter shield Complete Shield Complete (for models)
Part Numbers (partial list)
PS000S000 PS0XSS000 PS0S0SBX0 PS000SH30 PS00SDH3A PS0S0SH60 PS0SSDH6A PS00SSHXA PS0SSSHX0 PS000SS30 PS0S0SS30 PS0SSSS6B PS0SXDS60 PSJ0XSS60 PSLS0SS60 PS0SXSS60 PS00SSSXA PS0SSSSX0 PE000DL6C PE000DLXC PE000DZ6C PE000DZXC PE000SL6C PE000SLXC PE000SZ6C PE000SZXC PE000SS30 PE0S0SS30 PE000SS60 PE0SSSSX0 PE000SZXC PE0SSS000 PE0SSSH60 PE0S0DL6C PE0S0DLXC PE0S0DZ6C PE0S0DZXC PE0S0SL6C PE0S0SLXC PE0S0SZ6C PE0S0SZXC
Extender J-Series others Fuse holder
Optional switch
Optional filter
Additional extender which allows series adapt CORCOM's series product cutout, well panel cutout Schaffner Delta parts available. Extenders cannot added units with shields. When using interconnection block, last digits part number BX(0,
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
CORCOM Product Guide CHAMELEON Adaptable Module General, High Performance Medical Applications (Continued)
Series
Voltage Selection
series power entry modules provides dual voltage selector which integrated with fuseholder. simplify wiring each individual application, Tyco Electronics provides dedicated voltage selectors different voltage selection schemes. most popular schemes parallel serial dual primary transformers "DPST switch" switching mode power supplies (jumper types.) series products with fifth digit specifically designed "jumper" type applications associated with switching mode power supplies. series products with fifth digit specifically designed dual primary transformer applications. voltage selector installed will allow proper wiring from these applications. matter what voltage selection scheme used, wiring always made same four terminals.
Filter Options
Four filtering options available three current ratings. models (those with seventh digit) provide general purpose filtering both line-to-ground lineto-line noise. increased inductance series allows better performance than most power entry modules market. models will generally allow compliance with limits linear power supplies. high-performance models available general applications requiring higher attenuation. models greatly reduce line-to-ground capacitance compliance with leakage current specification. high-performance models available medical applications requiring higher attenuation.
Electrical Schematics
Model
Fuseholder
Another feature series power entry module versatile fusing arrangement. fuseholder hold 1/4" 1-1/4" 20mm fuses. also converted accept fuse with conversion clip that bridges fuse chambers. conversion clip installed Series power entry modules single fusing (those with part numbers with sixth digit). Units with sixth digit include conversion clip.
Model
Model LINE LOAD
Interconnection Block
Installation unfiltered versions series involves wiring socket switch switch fuseholder. Labor eliminated ordering product with interconnection block. This feature, designated seventh eighth digits, prewires module easier installation. wiring protected with plastic case better prevent access terminals connections. Wiring further simplified ordering PA100 connector assembly. page accessories. dimensions this alternative same filtered versions. Model LINE LOAD
Shield
feature available series shield. metal shield, available filtered models, provides shielding from radiated emissions provides additional ground filter case. shield available versions, shield filter components (designated ninth digit) complete shield (designated ninth digit). shield covers filter portion module increases performance filter protecting components from magnetic coupling. This shield improves ground connection case while still allowing Series extender. shield covers entire power entry module with metal, protecting equipment from radiated noise. Used with filter, shield provides most secure protection from noise problems. shield cannot used with extender.
Shield
Shield
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
CORCOM Product Guide CHAMELEON Adaptable Module General, High Performance Medical Applications (Continued)
Series
Specifications Unfiltered Models
Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Rated voltage (max.): Rated current, unfiltered models: 1500 1450 50/60
Specifications Filtered Models
Maximum leakage current, each line-to-ground: Models Models 0.25 Models Models Hipot rating (one minute): line-to-ground 1500 line-to-line 1450 Operating voltages: Selectable fixed 115/230 Operating frequency: 50/60 Rated voltage: 120/250 Conversion clip provided fuseholder single fuse models Switch: Double-insulated, rated 10,000 operations full load. inrush capability. Terminals: .187 .032 [4.8 .81] terminal tabs Minimum insertion loss Line-to-ground circuit Current Frequency-MHz Rating Models Models Current Rating Models Models Frequency-MHz
Operating voltages: Selectable fixed 115/230 Fuseholder: Accepts fuses 1-1/4 Conversion clip provided fuseholder single fuse models. Switch: Double-insulated rated 10,000 operations full load. inrush capability Terminals: .187 .032 [4.8 .81] terminal tabs Recommended connector solder
Power Entry Modules
Voltage Selection Schemes
Dual Primary Transformer Type:
115V Power on/off Note Ground Note Neutral Note
230V
Note
115V 115V Transformer primary
Provision single fusing
Jumper Type:
115V Power on/off Note Ground Note Neutral Note
230V Power input Sel. Jumpers SMPS
Note
Provision single fusing
Note Jumpers required filter interconnection module used. Note Location optional filter. Jumpers required filter interconnection module used.
Line-to-line circuit Current Frequency-MHz Rating Models Models Current Rating Models Models Frequency-MHz
Catalog 1654001 Revised 03-04
Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents.
Dimensions shown reference purposes only. Specifications subject change.
Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0
www.cor.com www.tycoelectronics.com
CORCOM Product Guide CHAMELEON Adaptable Module General, High Performance Medical Applications (Continued)
Series
Case Styles PS/PSL
Unfiltered Filtered Panel Cutout
0.06 Max. 1.52
0.02 Min. .508
.225 Max. 5.72
.225 5.72
snap-in applications, sides cutout must have [.508] radius installation side. Note: Snap-in models allow front mounting only. recommended plastic panels.
Unfiltered
Filtered
Panel Cutout
1.52
.020 .508
.225 Max. 5.72
.225 Max. 5.72
Unfiltered
Filtered
Panel Cutout
.225 Max. 5.72
.225 Max. 5.72
1.52
Catalog 1654001 Revised 03-04
ACTUAL MEASUREMENTS 1.2" 2.13"
Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents.
Dimensions shown reference purposes only. Specifications subject change.
Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0
www.cor.com www.tycoelectronics.com
CORCOM Product Guide CHAMELEON Adaptable Module General, High Performance Medical Applications (Continued)
Series
Case Styles PSC/PSJ
Unfiltered Filtered Panel Cutout
0.06 Max. 1.52
0.02 Min. .508
Power Entry Modules
.225 Max. 5.72
.225 5.72
snap-in applications, sides cutout must have [.508] radius installation side. Note: Snap-in models allow front mounting only. recommended plastic panels.
Filtered Versions
Shield
Case Dimensions
Part 1.24 31.49 1.24 31.49 1.98 50.29 1.24 31.49 1.24 31.49 1.24 31.49 1.93 49.02 1.93 49.02 1.93 49.02 1.93 49.02 1.93 49.02 1.93 49.02 2.13 54.1 2.13 54.1 2.13 54.1 2.13 54.1 2.13 54.1 2.13 54.1 2.31 58.67 2.31 58.67 2.31 58.67 73.66 2.51 63.75 2.72 69.09 1.06 26.93 1.12 28.45 1.122 28.5 1.06 26.93 1.06 26.93 1.06 26.93 (max) (max) (max) (max)
+.008/-.000 +.008/-.000 +.20/-.00 +.20/-.00
0.225 Max. .508
Shield
2.201* 55.91 2.201* 55.91 2.201* 1.575 55.91 40.0 2.13 2.496 54.1 63.4 2.52 64.01 2.6+ 66.0
Panel cutout thickness .031 .079 [0.8 2.0]. panel thickness .083 .114 [2.1 2.9] 2.213 [56.21]. Panel cutout thickness 0.06 0.09 [0.76 2.29]. shielded models D=1.12 +.008/-.000. Shields used only with filtered models. Shields approximately 0.06" depth. shield used with extender.
Rear View
Filtered
0.225 Max. .508
Unfiltered
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com

Other recent searches


SN74LS240 - SN74LS240   SN74LS240 Datasheet
SN74LS241 - SN74LS241   SN74LS241 Datasheet
SN74LS244 - SN74LS244   SN74LS244 Datasheet
SN74S240 - SN74S240   SN74S240 Datasheet
SN74S241 - SN74S241   SN74S241 Datasheet
SN74S244 - SN74S244   SN74S244 Datasheet
SN54LS240 - SN54LS240   SN54LS240 Datasheet
SN54LS241 - SN54LS241   SN54LS241 Datasheet
SN54LS244 - SN54LS244   SN54LS244 Datasheet
SN54S240 - SN54S240   SN54S240 Datasheet
SN54S241 - SN54S241   SN54S241 Datasheet
SN54S244 - SN54S244   SN54S244 Datasheet
NX7660JC - NX7660JC   NX7660JC Datasheet
N4436A - N4436A   N4436A Datasheet
L7810 - L7810   L7810 Datasheet
L7810-02 - L7810-02   L7810-02 Datasheet
L7820 - L7820   L7820 Datasheet
L7820-02 - L7820-02   L7820-02 Datasheet
IRF1010NS - IRF1010NS   IRF1010NS Datasheet
HJS18Z - HJS18Z   HJS18Z Datasheet
74AUP2G157 - 74AUP2G157   74AUP2G157 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive