The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Series XM/ZM Recognized Certified Approved Power Entry


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



CORCOM Product Guide Power Entry Module with Optional Power Line Filters General Medical Applications
Series
XM/ZM
Recognized Certified Approved
Power Entry Modules
Series
series power entry modules offer most choices power entry components filtering options specific need. fully configured series expands options manufacturer whose products marketed worldwide. component, fully assembled tested, provides capability interfacing multi-voltage power supply common voltage fusing scheme world, without modification. connector provides internationally accepted power entry termination, which used with variety line cords. selectable fuseholder allows single dual European fuses, single North American fuse. optional DPST on/off switch breaks both sides line labeled with international markings. optional voltage selector provides convenient means change transformer primary connection, available both 2-voltage 4-voltage configurations. series available with four filter circuits meet variety applications, convenient connections provided unfiltered models allow wiring separate filter. series family components offering greater flexibility cost-effectiveness selection primary power components. Wiring modules accomplished .110" terminals labor savings convenience. Four filter circuits provide choice attenuation tailored specific categories susceptibility emissions needs. Models This medical filter provides susceptibility protection without leakage current associated with line-to-ground capacitors. Designed allow equipment meet UL544 patient care non-patient care equipment, filter maximum leakage current Appendix more information medical applications standards.
Models General purpose filter designed susceptibility applications, effectively providing control line-to-ground noise. design compact meets very leakage current requirements portable equipment well (120 Volt) UL544 non-patient medical equipment. Models High performance filter designed bring most digital equipment (including switching power supplies) into compliance with Part 15J, Class conducted emissions limits. Models Premium filter designed bring most digital equipment (including switching power supplies) into compliance with EN55022, Level well Part 15J, Class conducted emissions limits.
Fuse Installation Instructions
Remove power cord. door open socket. Lift swing door into socket. Lift fuse holder housing. Install fuse metric fuses*. Replace fuse holder into housing. Swing snap door back place.
*Install fuses side only, install both metric fuses same time.
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional Power Line Filters General Medical Applications (Continued)
Series
UNFILTERED MODELS
Part Number 6VM1 6VM1C 6VM1S 6VM1SC 6VM2 6VM2S 6VM4 6VM4C 6VM4S 6VM4SC
120V/240V Fixed
Current Rating @120VAC (Amps)
Current Rating 250VAC (Amps)
Available Voltage Selection Position*
DPST On/Off Switch
Mounting Style Flange Snap-in Flange Snap-in Flange Flange Flange Snap-in Flange Snap-in
Fuseholder Type Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable
120/240 Selectable
100V, 120V, 230V, 240V Selectable
Includes DPST switch
FILTERED MODELS
Part Number 5EHM1 5EHM1S 5EHM4 5EHM4S 5EFM1 5EFM1C 5EFM1S 5EFM1SC 5EFM4 5EFM4C 5EFM4S 5EFM4SC 3EXM1S 3EXM4 3EXM4S 3EZM1S 3EZM4 3EZM4S
Current Rating Current Rating Available Voltage DPST Filter @120VAC @250VAC Selection On/Off Type (Amps) (Amps) Position Switch Medical1 Medical1 Medical1 Medical1 General Purpose2 General Purpose2 General Purpose2 General Purpose2 General Purpose2 General Purpose2 General Purpose2 General Purpose2 SMPS FCC-B3 SMPS FCC-B3 SMPS FCC-B3 SMPS EN55022-B4 SMPS EN55022-B4 SMPS EN55022-B4
Mounting Style Flange Flange Flange Flange Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Flange Flange Flange Flange Flange
Fuseholder Type Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable Selectable
Includes DPST switch Medical filter very leakage health care applications. General purpose filter susceptibility applications. Emissions filter switching power supply applications where FCC-B level requirements must met. Emissions filter switching power supply applications where EN55022-B level requirements must met. Refer page more information available filter types. 120V/240V Fixed 100V, 120V, 230V, 240V Selectable
Fuse Changing
European Fusing Arrangement** North American Fusing Arrangement**
**Install fuses side only. install both Metric fuses same time.
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional Power Line Filters General Medical Applications (Continued)
Series
Specifications Unfiltered Models
Hipot rating (one minute): line-to-ground 1500 line-to-line 1450 line-to-load (switch off) 2500 Operating voltages: 100, 120, 230, Operating frequency: 50/60 Switch: Double-insulated, rated 100,000 operations full load. 10,000 operations Amps inrush current. Fuse (not included): Reversible fuseholder, accepts 1/4" 1-1/4" fuse fuses. .110 [2.79] terminals
Specifications Filtered Models
Maximum leakage current,each line-to-ground XM/ZM Hipot rating (one minute): line-to-ground: Models 1500 FM/XM/ZM 1500 line-to-line Models 1450 Operating voltages: 100, 120, 230, Operating frequency: Rated voltage (max.): Switch: 50/60
Power Entry Modules
Terminals:
Double-insulated, rated 100,000 operations full load. 10,000 operations Amps inrush current. Reversible fuseholder, accepts 1/4" 1-1/4" fuse fuses .110 [2.79] terminals
Electrical Schematics Unfiltered Models
(1-Voltage)
Power On/Off Note
Fuse (not included):
Terminals:
Neutral
Note
Minimum insertion loss Line-to-ground circuit
120V
Customer Transformer Primaries
(2-Voltage)
Power On/Off Note 120V
240V
120V
Neutral
Note Note
120V
Current Rating
Frequency-MHz
120V
120V
Note
Line-to-line circuit Current Rating Frequency-MHz
Note Customer Transformer Primaries
(4-Voltage)
Power On/Off Note 120V 100V 230V 240V
100V
Neutral
Note
Note
230V Nomenclature relates pending European CENELEC agreement.
120V
Note Note Note Note
Note
Customer Transformer Primaries
Jumpers required input filter used. Provision dual European style fusing. On/off switch present only with suffix. When using center-tapped transformer, winding should voltage (high current) winding must capable handling full primary current 120V position.
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional Power Line Filters General Medical Applications (Continued)
Series
Case Dimensions Unfiltered Models
Part 6VM1 6VM1C 6VM1S 6VM1SC 6VM2 6VM4 6VM4C 6VM2S 6VM4S 6VM4SC (max) 3.39 86.1 2.56 86.1 4.17 105.9 3.34 84.8 3.88 98.6 3.04 98.6 4.65 118.1 3.82 97.0
±0.01 0.25
Case Dimensions Filtered Models
63.5 63.2 3.28 83.3 3.27 83.1 2.98 75.7 2.97 75.4 3.76 95.5 3.75 95.3 Part 5EFM1 5EHM1 (max)
±0.01 ±0.25
(max) (max) (max) 1.14 29.0 1.14 29.0 1.14 29.0 1.14 29.0 1.14 29.0 1.14 29.0 1.14 29.0 1.14 29.0 2.44 62.0 2.44 62.0 3.22 81.8 3.27 83.1 2.92 74.2 2.92 74.2 3.72 94.5 94.0 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8
(max) (max) (max) 2.44 62.0 2.44 62.0 3.22 81.8 3.27 83.1 2.92 74.2 2.92 74.2 94.0 94.0 3.22 81.8 2.92 74.2 3.72 94.5 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 1.72 43.7 1.72 43.7 1.72 43.7
63.5 2.49 63.2 3.28 83.3 3.27 83.1 2.98 75.7 2.97 75.4 3.76 95.5 3.75 95.3 3.28 83.8 2.98 75.7 3.76 95.5
2.84 72.1 3.62 91.9 3.32 84.3 104.1
Voltage Selection
change selected voltage: open cover, using small blade screwdriver similar tool; aside cover/fuse block assembly; pull voltage selector card straight housing, using indicator pin; orient selector card that desired voltage readable bottom; orient indicator point when desired voltage readable bottom (note that when indicator fixed, successive voltages selected rotating card clockwise); insert voltage selector card into housing, printed side card facing forward toward connector edge containing desired voltage first; replace cover, verify that indicator shows desired voltage. Voltage Selector Card Orientation
3.39 86.1 5EFM1C 2.56 65.0 5EFM1S 4.17 5EHM1S 105.9 5EFM1SC 3.34 84.8 5EFM4 3.88 5EHM4 98.6 5EFM4C 3.04 77.2 5EFM4S 4.65 5EHM4S 118.1 5EFM4SC 3.82 97.0 3EXM1S 4.17 3EZM1S 105.9 3EXM4 3.88 3EZM4 98.6 3EXM4S 4.65 3EZM4S 118.1
1.14 29.0 1.14 29.0 3.62 1.14 91.9 29.0 1.14 29.0 3.32 1.14 84.3 29.0 1.14 29.0 1.14 104.1 29.0 1.14 29.0 3.62 1.14 91.9 29.0 3.32 1.14 84.3 29.0 1.14 104.1 29.0
2.84 72.1
83.8 2.99 75.9 96.5
Recommended Panel Cutout
*Blind insert Models only
29.7 .508 models 1.13 .020 28.7 .508 0.13 3.30
Holes
Models 1.17 .020
1.88 .020 47.8 .508
.570 14.5
.170 Dia. 4.32 .175 4.45
1.145 29.08
100V
120V Note: Snap-in models allow front mount only. models allow back mount only. models allow front back mounting.
230V
240V
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
Accessories series include interconnection assembly, medical standoff bracket, voltage selector cards, insulating shroud. page 131. mounting holes countersunk.
CORCOM Product Guide Power Entry Module with Optional Power Line Filters General Medical Applications (Continued)
Series
Case Styles Unfiltered Models
6VM1 (IEC Connector, Selectable Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
6VM2 6VM4 (IEC Connector, Voltage Selector, Selectable Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
Power Entry Modules
6VM1C (IEC Connector, Selectable Fuseholder, Snap-in)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
6VM4C (IEC Connector, Voltage Selector, Selectable
Fuseholder, Snap-In)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
6VM1S (IEC Connector, DPST On/Off Switch, Selectable Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
6VM2S 6VM4S (IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
6VM1SC (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder, Snap-In)
6VM4SC (IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder, Snap-In)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
Recommended Panel Cutout (Snap-In Only)
0.13 3.30 1.145 29.08
Typical dimensions: Mounting Holes: .155 [3.94] Dia. with .279 [7.09] Dia. Countersunk. mounting holes countersunk. Panel Thickness: [1.53 -2.29]
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional Power Line Filters General Medical Applications (Continued)
Series
Electrical Schematics Filtered Models
(1-Voltage)
Power On/Off
(1-Voltage)
Power On/Off
Neutral
Note Note
Neutral
Note Note Note
Phase
Phase
(4-Voltage)
120V 100V 230V 240V
100V 120V
(4-Voltage)
120V 100V Power On/Off 230V 240V
120V 100V
Neutral
Power On/Off Note Note
Note
Neutral
Note Note Note
Note
Phase
Note
Customer Transformer Primaries
Phase
Note
Customer Transformer Primaries
5EFM1SC (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
ONLY WITH 250V FUSES
Case Styles Filtered Snap-In Models
5EFM1C (IEC Connector, Selectable Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES
5EFM4SC (IEC Connector, DPST On/Off Switch, Voltage
Selector, Selectable Fuseholder)
5EFM4C (IEC Connector, Voltage Selector, Selectable
Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
100V 120V 230V 240V
Note Note Note Note
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents.
Provision dual fusing (Euro standard) Power on/off switch with suffix only models without line-to-ground capacitors Models HM4, FM4, XM4, have added terminals External switch jumper must placed from 230V Nomenclature relates pending European CENELEC agreement.
Dimensions shown reference purposes only. Specifications subject change.
Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0
www.cor.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional Power Line Filters General Medical Applications (Continued)
Series
Case Styles Filtered Models
5EHM1 5EFM1 (IEC Connector, Selectable
Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
Case Styles Filtered Models
3EXM4 3EZM4 (IEC Connector, Voltage Selector, Selectable Fuseholder)
1.88±.020 47.8±.508
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
Thread 6-32 1.13±.020 28.7±.508 3.09 Max. 78.49
100V 120V 230V 240V
Power Entry Modules
5EHM1S 5EFM1S (IEC Connector, DPST On/Off
Switch, Selectable Fuseholder)
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
3EXM1S 3EZM1S (IEC Connector, DPST On/Off Switch, Selectable Fuseholder) 5EHM4 5EFM4 (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
100V 120V 230V 240V
Thread 6-32 1.13±.020 28.7±.508
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
1.88±.020 47.8±.508
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
3.09 Max. 78.49
5EHM4S 5EFM4S (IEC Connector, DPST On/Off
Switch, Voltage Selector, Selectable Fuseholder)
100V 120V 230V 240V
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
3EXM4S 3EZM4S (IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder)
Thread 6-32 1.17±.020 29.7±.508 1.88±.020 47.8±.508
ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
3.09 Max. 78.49
100V 120V 230V 240V
Typical dimensions: Torque: max. Holes: .055 [1.40] Dia. ±.004 [±.10] except solder ground with wire wrap. Mounting Holes: .155 [3.94] Dia. parts typical. Note: Mounting holes tabs countersunk take flathead screw.
Catalog 1654001 Revised 03-04 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com

Other recent searches


XR20M1170 - XR20M1170   XR20M1170 Datasheet
TN2404K - TN2404K   TN2404K Datasheet
TN2404KL - TN2404KL   TN2404KL Datasheet
BS107KL - BS107KL   BS107KL Datasheet
FAN1655 - FAN1655   FAN1655 Datasheet
EPT7059 - EPT7059   EPT7059 Datasheet
EPT7059-RC - EPT7059-RC   EPT7059-RC Datasheet
EID0910A-25 - EID0910A-25   EID0910A-25 Datasheet
BAT60A - BAT60A   BAT60A Datasheet
2SC5130 - 2SC5130   2SC5130 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive