| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
H5CX-B 2-Stage Digital Timer with 6-digit Display Forecast Output
Top Searches for this datasheet2-stage Digital Timer H5CX-B 2-Stage Digital Timer with 6-digit Display Forecast Output Wide time setting range from 0.01 99,999.9 (over time ranges). 6-digit display enables cumulative on-delay timing functions. NPN/PNP switchable DC-voltage input. Forecast output 2-stage settings ideal maintenance applications. Programmable display color alert output status change. Supply voltage only available 12-24 VDC. NEMA4/IP66 front. Model Number Structure Model Number Legend H5CX-BWSD Type classifier 6-digit display type Stage setting 2-stage setting Output type Transistor output Supply voltage Ordering Information List Models Stock Note: Shaded models normally stocked. Output type Transistor Supply voltage H5CX-BWSD 6-digit display Screw terminals Accessories (Order Separately) Stock Note: Shaded models normally stocked. Item Flush Mounting Adapter (See note.) Waterproof Packing (See note.) Hard Cover Soft Cover Note: Supplied with H5CX-BWSD. Y92F-30 Y92S-29 Y92A-48 Y92A-48F1 Model 2-stage Digital Timer H5CX-B Specifications Ratings Item Classification Rated supply voltage Operating voltage range Power consumption (See note Mounting method External connections Digital timer (permissible ripple: (p-p) max.) 110% rated supply voltage Approx. Flush mounting Screw terminals H5CX-BWSD Terminal screw tightening max. torque Display (See note 7-segment, negative transmissive LCD; Present value: 9-mm-high characters, value: 6-mm-high characters, green digits 9999.99 (0.01-s unit), (1-s unit), 99999.9 (0.1-min unit), 99999.9 (0.1-h unit) Elapsed time (Up) Signal, reset, gate No-voltage input/voltage input (switchable) No-voltage Input impedance: max. (Leakage current: when residual voltage: max. impedance: min. Voltage Input High (logic) level: (logic) level: (Input resistance: approx. Minimum input signal width: (selectable, same input) Power resets (only mode), external manual reset Minimum power-opening time: (except mode) max. (Control output turned input accepted during sensor waiting time.) Transistor output: open collector, max. residual voltage: max. (Approx. Leakage current: max. Output category according EN60947-5-2 (DC-13; protection Memory backup Ambient temperature Ambient humidity Case color Attachments EEPROM (overwrites: 100,000 times min.) that store data years min. Operating: Storage: Black (N1.5) Waterproof packing, flush mounting adapter, unit label 55°C (-10 50°C timers mounted side side) (with icing condensation) 65°C (with icing condensation) Digits Time ranges Timer mode Input signals Input method Signal, reset, gate Reset system Power reset Sensor waiting time Output modes Control output Note: Inrush current will flow short time when power supply turned Refer Inrush Current (Reference Values) page display only when power 2-stage Digital Timer H5CX-B Characteristics Item Accuracy operating time setting error (including temperature voltage influences) (See note Insulation resistance Dielectric strength Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance Approved safety standards (See note H5CX-BWSD Power-ON start: ±0.02% ±0.05 max. Rated against value Signal start (minimum pulse width ms): ±0.01% ±0.03 max. Rated against value Signal start (minimum pulse width ms): ±0.01% max. value within sensor waiting time startup control output H5CX will turn until sensor waiting time passes. min. VDC) between current-carrying terminal exposed non-current-carrying metal parts 2,000 VAC, 50/60 between current-carrying metal parts non-current-carrying metal parts 1,000 VAC, 50/60 between control output, power supply, input circuit (between power terminals) (between current-carrying terminal exposed non-current-carrying metal parts) ±480 (between power terminals) ±600 (between input terminals), square-wave noise noise simulator (pulse width: ns/1 1-ns rise) Destruction: Malfunction: Destruction: with 0.75-mm single amplitude each three directions, four cycles each cycle) Malfunction: with 0.35-mm single amplitude each three directions, four cycles each cycle) Destruction: m/s2 each three directions Malfunction: m/s2 each three directions UL508/Listing, UL50 Type indoor (enclosure rating), C22.2 conforms EN61010-1 (Pollution degree 2/overvoltage category Conforms VDE0106/P100 (finger protection). (EMI) Emission Enclosure: (EMS) Immunity ESD: Immunity RF-interference: Immunity Conducted Disturbance: Immunity Burst: Immunity Surge: Degree protection Weight EN61326 EN55011 Group class EN61326 EN61000-4-2: contact discharge (level discharge (level EN61000-4-3: (Amplitude-modulated, GHz) (level (Pulse-modulated, MHz) (level EN61000-4-6: EN61000-4-4: EN61000-4-5: (0.15 MHz) (level power-line (level signal-line (level line lines (power output lines) (level line ground (power output lines) (level Panel surface: IP66 NEMA4 (indoors), Type (indoors) (See note Approx. Note: values based value. Y92S-29 Waterproof Packing Y92F-30 Flush Mounting Adapter necessary ensure IP66, NEMA4, Type waterproofing between H5CX installation panel. Inrush Current (Reference Values) Voltage 26.4 Applied voltage Inrush current (peak value) Time 2-stage Digital Timer H5CX-B Connections Block Diagram Output circuit (Basic insulation) Display circuit Input circuit Internal control circuit switch circuit Power supply circuit Functions Inputs Start signal Reset Starts timing. Resets present value. (The present value returns Timing stops control output turns while reset input Reset indicator while reset input Inhibits timer operation. Control output (OUT2) Forecast output (OUT1) Absolute value setting Control output (OUT2) Control output (OUT1) Turns when present value reaches value. Turns when present value reaches forecast value. forecast value value forecast value Turns when present value reaches value Turns when present value reaches value Gate Outputs Forecast value setting 2-stage Digital Timer H5CX-B Terminal Arrangement Signal Reset Reset Gate Input Unused OUT1 OUT2 Note: connect unused terminals relay terminals. power supply input circuit isolated. Terminals connected internally. Terminals have same reset function. same function will performed whichever terminal connected. Terminals connected internally, however, them cross-over wiring. Recommended lead wires: AWG18 AWG24 (cross-sectional area: 0.205 0.823 mm2), single line twisted-pair cable, made copper aluminum. Input Circuits Signal, Reset, Gate Input No-voltage Input (NPN Inputs) Voltage Inputs (PNP Inputs) Approx. Internal circuit Internal circuit 2-stage Digital Timer H5CX-B Input Connections inputs H5CX-B no-voltage (short-circuit open) inputs voltage inputs. No-voltage Inputs (NPN Inputs) Open Collector (Connection open collector output sensor) sensor Voltage Output (Connection voltage output sensor) Sensor Contact Input Two-wire Sensor Signal input Reset input Signal input Reset input Reset input Gate input Signal input Reset input Reset input Gate input Input Reset input Gate input Input Input Operate with transistor Operate with transistor Operate with relay Operate with transistor Applicable Two-wire Sensor Leakage current: Switching capacity: Residual voltage: Operating voltage: max. min. max. No-voltage Input Signal Levels No-contact input Short-circuit level Transistor Residual voltage: max. Impedance when max. (the leakage current when impedance Open level Transistor Impedance when OFF: min. Contact input Note: voltage must max. contact which adequately switch Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) (Connection open collector output sensor) No-contact Input (PNP Transistor) (Connection open collector output sensor) Contact Input Sensor Sensor Signal input Signal input Gate input Reset input Gate input Reset input Gate input Operate with transistor Operate with transistor Operate with relay Voltage Input Signal Levels High level (Input ON): level (Input OFF): Input resistance: Approx. Note: voltage must max. 2-stage Digital Timer H5CX-B Reset input Signal input Reset input Reset input Reset input Input Input Input Gate input Input Signal input Reset input Reset input Nomenclature Indicator Reset Indicator (orange) when reset input Reset Protection Indicator (orange) when Key-protect Switch Control Output Indicator (orange) Forecast value setting: Forecast output Control output Absolute value setting: Control output Control output Present Value (red) Character height: time range decimal point flashes indicate timing operation. Value (green) Character height: Value Display (green) Operation Mode (Changes setting items) Reset (Resets present value output) Keys Sixth digit First digit Front View Switches Key-protect Switch When Key-protect Switch operations prohibited according settings switch pins thus preventing setting errors. Key-protect Switch turned while power Protection Indicator orange when Keyprotect Switch (Default setting) Switch Refer Switch Settings page details setting switch. (Default setting) Unit Label unit label included with Unit. Affix unit label position shown following diagram match time range used. Align right edge label with right edge display window. Unit label 2-stage Digital Timer H5CX-B Dimensions Unit: (inch) Dimensions without Flush Mounting Adapter H5CX-BWSD (Flush Mounting Models) Panel Cutouts Panel cutouts areas shown below. (according DIN43700). min. +0.6 +0.6 min. min. Note: M3.5 terminal screw (effective length: 6mm) Dimensions with Flush Mounting Adapter H5CX-BWSD (Provided with Adapter Waterproof Packing) Note mounting panel thickness should allow easier operability, recommended that Adapters mounted that between sides with hooks least possible mount timers side side, only direction without hooks. side side mounting (48n 2.5) With Y92A-48F1 attached. {48n-2.5 (n-1) With Y92A-48 attached. (51n-5.5) 2-stage Digital Timer H5CX-B Accessories (Order Separately) Hard Cover Y92A-48 Soft Cover Y92A-48F1 Note: Depending operating environment, condition resin products deteriorate, shrink become harder. Therefore, recommended that resin products replaced regularly. H5CX's panel surface water-resistive (conforming IP66) even drops water penetrate gaps between keys, there will adverse effect internal circuits. however, there possibility being present operator's hands, Soft Cover. Soft Cover ensures protection equivalent IP54F against oil. not, however, H5CX locations where would come direct contact with oil. Flush Mounting Adapter (provided with H5CX-BWSD) Y92F-30 Waterproof Packing (provided with H5CX-BWSD) Y92S-29 Note: Order Flush Mounting Adapter separately lost damaged. Note: waterproof packing provide level water protection that complies with NEMA4, Type IP66 standards. Order waterproof packing separately lost damaged. Depending operating environment, waterproof packing deteriorate, contract, harden regular replacement recommended. 2-stage Digital Timer H5CX-B Operating Procedures Setting Values values either offset values (forecast value setting) absolute values. values factory-set forecast value setting. Forecast Value Setting Example: Mode Present value value Forecast value Forecast value Turn power while pressing Key. Timing stopped Timing possible Setting Method Selection Mode Change setting method using Keys Forecast output (OUT1) Control output (OUT (Forecast value setting) (Absolute value setting) Turn power again. Mode OUT1 (forecast output) turns when present value reaches forecast value. forecast value value forecast value forecast value used deviation value. OUT2 (control output) turns when present value reaches value. forecast value value, OUT1 (forecast output) will turn soon timing starts. Move Setting Method Selection Mode turning power while pressing both same time. Select forecast value setting absolute value setting using Keys. When power turned again, Timer will start with selected setting method. Note: Setting Method Selection Mode, outputs timer stopped. When setting method changed, values present value reset outputs OFF. Absolute Value Setting Example: Mode Present value value value Control output (OUT1) Control output (OUT OUT1 (control output turns when present value reaches value OUT2 (control output turns when present value reaches value 2-stage Digital Timer H5CX-B Switch Settings functions using switch. Item Output mode Input signal width NPN/PNP input mode Reset protection protection Mode protection mode Disabled Disabled Disabled mode Enabled Time range 99999.9 0.01 9999.99 99999.9 Time range Refer table right. Enabled Enabled (Default setting) Note: pins factory-set OFF. switch settings effective when power turned again. (Set switch before installation powerup.) shaded characters default settings. Operation Mode each digit value using corresponding Keys. Forecast Value Setting Present value value Present value Each time pressed, sub-display will switch between value ("SET" lit) forecast value ("1" lit). Forecast value Absolute Value Setting Present value value Present value value Each time pressed, sub-display will switch between value ("SET lit) value ("SET lit). 2-stage Digital Timer H5CX-B Timing Charts Mode: Signal delay (Timer resets when power comes ON.) Power Start signal Timing starts when start signal turns While start signal timer starts when power turns when reset input turns OFF. sustained control output used. Timing stops when time Gate Basic Operation Power Reset Timing diagram 999999 value Forecast value OUT1 Start signal input** Forecast output (Control output OUT1 Control output (Control output OUT2 names parentheses used absolute value setting. Timing OUT2 names parentheses used absolute value setting. Output instantaneous when value Start signal input disabled during timing. mode: Cumulative (Timer does reset when power comes ON.) Power Start signal Start signal enables timing (timing stopped when start signal when power OFF). sustained control output used. Timing continues even after time Gate Basic Operation Power Reset Timing diagram 999999 value Forecast value Start signal input Forecast output (Control output OUT1 Control output (Control output OUT2 Timing Sustained Timing OUT1 OUT2 names parentheses used absolute value setting. names parentheses used absolute value setting. Output instantaneous when value Note: Forecast Value Value Forecast Value forecast value used deviation value. Self-diagnostic Function following displays will appear error occurs. Main display Sub-display Memory error (RAM) Memory error (EEP) (See note) Error Output status Correction method value after reset Either press reset reset change power supply. Reset power supply. Reset factory settings using reset key. change Note: This includes times when life EEPROM expired. 2-stage Digital Timer H5CX-B Safety Precautions (Common) Note: following precautions common H5CX models. !Caution This occasionally cause electric shock, fire malfunction. allow metal fragments lead wire scraps fall inside this product. !Caution Loose screws occasionally result fire malfunction. Tighten terminal screws securely. recommended tightening torque !Caution There occasionally risk explosion. product where flammable combustion gases present. !Caution This occasionally cause electric shock, fire malfunction. Ensure that power turned before changing switch settings. Changing switch settings with power turned result electric shock contact with terminals subject high voltages. attention terminal polarity ensure correct wiring. Make sure that fluctuation supply voltage within permissible range. Apply power supply voltage through relay switch such that voltage reaches rated value within voltage applied gradually, power reset unstable output operations result. Leaving H5CX with outputs high temperature long time hasten degradation internal parts (such electrolytic capacitors). Therefore, product combination with relays avoid leaving product long more than month with output turned !Caution Never disassemble, repair modify product. X2/b X1/a X1/a !Caution This occasionally cause electric shock, fire malfunction. allow metal fragments lead wire scraps fall inside this product. Auxiliary relay (e.g., Relay) When product operated with no-voltage input (NPN input), approximately output from input terminals, connect diode external power supply less than !Caution both power supply input device that timer insulated, unwanted current from power supply occasionally burn damage internal parts. Always insulated power supply timer. Sensor Input Precautions Safe following precautions must observed ensure safety. Operating Storage Conditions locations affected excessive vibration shock, locations subject exposure water oil. product locations subject dust, corrosive gases, direct sunlight. Separate input signal devices, input signal cables, product from source noise high-tension cables producing noise. Separate product from source static electricity when using product environment where large amount static electricity produced (e.g., forming compounds, powders, fluid materials being transported pipe). Organic solvents (such paint thinner), well very acidic basic solutions might damage outer casing H5CX. product within ratings specified temperature humidity. product locations where condensation occur high humidity where temperature changes severe. Store specified temperature. H5CX been stored temperature less than -10°C, allow H5CX stand room temperature least hours before use. Install switch circuit-breaker that allows operator immediately turn power, make sure labeled clearly. H5CX's panel surface water-resistive (conforming NEMA Type IP66). order prevent internal circuit from water penetration through space between H5CX operating panel, attach waterproof packing (Y92S-29) between H5CX installation panel secure waterproof packing with Y92F-30 Flush-mounting Adapter. recommended that space between screw head adapter should Tighten mounting screws Adapter. Tighten them alternately, little time, keep them equal tightness. panel screws tightened unequally, water ingress inside panel. Usage Precautions Make sure that voltage applied within specified range, otherwise internal elements counter damaged. load current must within rated current. 2-stage Digital Timer H5CX-B Precautions Correct Power Supplies Turn power using relay with rated capacity minimum prevent contact deterioration inrush current caused turning power OFF. sure that capacity power supply large enough, otherwise Timer start inrush current that flow instant when Timer turned When turning power OFF, input signal reception possible, unstable, impossible shown diagram below. Power supply Input Impossible Unstable Unstable Impossible Response Delay Time When Resetting (Transistor Output) following table shows delay from when reset signal input until output turned OFF. (Reference value) Minimum reset signal width Output delay time Power Failure Backup data stored EEPROM when there power failure. EEPROM overwritten more than 100,000 times. Operating mode Overwriting timing When power turned OFF. When settings changed. Possible mode mode Timer Control with Power Start allow startup time peripheral devices (sensors, etc.), H5CX starts timing operation between after power turned this reason, operations where timing starts from power time display will actually start from value less, time until output turns will fixed value between 250. (Normal operation possible value more.) applications where value less required, start timing with signal input. When H5CX used with power start mode (i.e., accumulative operation with output hold), there will timer error (approximately each time H5CX turned characteristics internal circuitry. H5CX with signal start timer accuracy required. Conformance EN/IEC Standards There insulation between power supply input terminals. Basic insulation between power supply output terminals, between input terminals output terminals. Input output terminals connected devices without exposed charged parts. Input output terminals connected devices with basic insulation that suitable maximum operating voltage. Transistor Output transistor output H5CX insulated from internal circuitry photocoupler, transistor output used both output. Output Output Load Load Power load Power load diode connected collector output transistor used absorb inverted voltage that generated when inductive load connected H5CX. Timer Inductive load Power load 2-stage Digital Timer H5CX-B Safety Precautions (H5CX-B) Precautions Safe Changing Value When changing value during timing operation, output will turn value changed follows because constant read-in system: Forecast Value Setting When present value value, OUT2 (control output) turns When present value forecast value (forecast value value forecast value) OUT1 (forecast output) turns Absolute Value Setting When present value value OUT2 (control output turns When present value value OUT1 (control output turns Precautions Correct Operation with Value When value output turns moment signal input. reset operation turns output. 2-stage Digital Timer H5CX-B Certain Terms Conditions Sale Offer; Acceptance. These terms conditions (these "Terms") deemed part catalogs, manuals other documents, whether electronic writing, relating sale goods services (collectively, "Goods") Omron Electronics subsidiary companies ("Seller"). Seller hereby objects terms conditions proposed Buyer's purchase order other documents which inconsistent with, addition these Terms. Please contact your Omron representative confirm additional terms sales from your Omron company. Prices. prices stated current, subject change without notice Seller. Buyer agrees price effect time shipment. Discounts. Cash discounts, any, will apply only amount invoices sent Buyer after deducting transportation charges, taxes duties, will allowed only invoice paid according Seller's payment terms (ii) Buyer past amounts owing Seller. Orders. Seller will accept order less than $200 billing. Governmental Approvals. Buyer shall responsible for, shall bear costs involved obtaining government approvals required importation sale Goods. Taxes. taxes, duties other governmental charges (other than general real property income taxes), including interest penalties thereon, imposed directly indirectly Seller required collected directly indirectly Seller manufacture, production, sale, delivery, importation, consumption Goods sold hereunder (including customs duties sales, excise, use, turnover license taxes) shall charged remitted Buyer Seller. Financial. financial position Buyer time becomes unsatisfactory Seller, Seller reserves right stop shipments require satisfactory security payment advance. Buyer fails make payment otherwise comply with these Terms related agreement, Seller (without liability addition other remedies) cancel unshipped portion Goods sold hereunder stop Goods transit until Buyer pays amounts, including amounts payable hereunder, whether then due, which owing Buyer. Buyer shall event remain liable unpaid accounts. Cancellation; Etc. Orders subject rescheduling cancellation unless Buyer indemnifies Seller fully against costs expenses arising connection therewith. Force Majeure. Seller shall liable delay failure delivery resulting from causes beyond control, including earthquakes, fires, floods, strikes other labor disputes, shortage labor materials, accidents machinery, acts sabotage, riots, delay lack transportation requirements government authority. Shipping; Delivery. Unless otherwise expressly agreed writing Seller: Shipments shall carrier selected Seller; Such carrier shall agent Buyer delivery such carrier shall constitute delivery Buyer; sales shipments Goods shall shipping point (unless otherwise stated writing Seller), which point title risk loss Goods shall pass from Seller Buyer, provided that Seller shall retain security interest Goods until full purchase price paid Buyer; Delivery shipping dates estimates only. Seller will package Goods deems proper protection against normal handling extra charges apply special conditions. Claims. claim Buyer against Seller shortage damage Goods occurring before delivery carrier must presented writing Seller within days receipt shipment include original transportation bill signed carrier noting that carrier received Goods from Seller condition claimed. Warranties. Exclusive Warranty. Seller's exclusive warranty that Goods will free from defects materials workmanship period twelve months from date sale Seller such other period expressed writing Seller). Seller disclaims other warranties, express implied. Limitations. SELLER MAKES WARRANTY REPRESENTATION, EXPRESS IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY FITNESS PARTICULAR PURPOSE GOODS. BUYER ACKNOWLEDGES THAT ALONE DETERMINED THAT GOODS WILL SUITABLY MEET REQUIREMENTS THEIR INTENDED USE. Seller further disclaims warranties responsibility type claims expenses based infringement Goods otherwise intellectual property right. Buyer Remedy. Seller's sole obligation hereunder shall replace form originally shipped with Buyer responsible labor charges removal replacement thereof) noncomplying Good Seller's election, repay credit Buyer amount equal purchase price Good; provided that event shall Seller responsible warranty, repair, indemnity other claims expenses regarding Goods unless Seller's analysis confirms that Goods were properly handled, stored, installed maintained subject contamination, abuse, misuse inappropriate modification. Return goods Buyer must approved writing Seller before shipment. Seller shall liable suitability unsuitability results from Goods combination with electrical electronic components, circuits, system assemblies other materials substances environments. advice, recommendations information given orally writing, construed amendment addition above warranty. Damage Limits; Etc. SELLER SHALL LIABLE SPECIAL, INDIRECT CONSEQUENTIAL DAMAGES, LOSS PROFITS PRODUCTION COMMERCIAL LOSS CONNECTED WITH GOODS, WHETHER SUCH CLAIM BASED CONTRACT, WARRANTY, NEGLIGENCE STRICT LIABILITY. Further, event shall liability Seller exceed individual price Good which liability asserted. Indemnities. Buyer shall indemnify hold harmless Seller, affiliates employees from against liabilities, losses, claims, costs expenses (including attorney's fees expenses) related claim, investigation, litigation proceeding (whether Seller party) which arises alleged arise from Buyer's acts omissions under these Terms with respect Goods. Without limiting foregoing, Buyer expense) shall indemnify hold harmless Seller defend settle action brought against Seller extent that based claim that Good made Buyer specifications infringed intellectual property rights another party. Property; Confidentiality. intellectual property embodied Goods exclusive property Seller affiliates Buyer shall attempt duplicate without written permission Seller. Notwithstanding charges Buyer engineering tooling, engineering tooling shall remain exclusive property Seller. information materials supplied Seller Buyer relating Goods confidential proprietary, Buyer shall limit distribution thereof trusted employees strictly prevent disclosure third party. Miscellaneous. Waiver. failure delay Seller exercising right course dealing between Buyer Seller shall operate waiver rights Seller. Assignment. Buyer assign rights hereunder without Seller's written consent. Amendment. These Terms constitute entire agreement between Buyer Seller relating Goods, provision changed waived unless writing signed parties. Severability. provision hereof rendered ineffective invalid, such provision shall invalidate other provision. Setoff. Buyer shall have right amounts against amount owing respect this invoice. used herein, "including" means "including without limitation". Certain Precautions Specifications Suitability Use. Seller shall responsible conformity with standards, codes regulations which apply combination Good Buyer's application Good. Buyer's request, Seller will provide applicable third party certification documents identifying ratings limitations which apply Good. This information itself sufficient complete determination suitability Good combination with product, machine, system, other application use. following some examples applications which particular attention must given. This intended exhaustive list possible uses this Good, intended imply that uses listed suitable this Good: Outdoor use, uses involving potential chemical contamination electrical interference, conditions uses described this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, installations subject separate industry government regulations. (iii) Systems, machines equipment that could present risk life property. Please know observe prohibitions applicable this Good. NEVER PRODUCT APPLICATION INVOLVING SERIOUS RISK LIFE PROPERTY WITHOUT ENSURING THAT SYSTEM WHOLE BEEN DESIGNED ADDRESS RISKS, THAT SELLER'S PRODUCT PROPERLY RATED INSTALLED INTENDED WITHIN OVERALL EQUIPMENT SYSTEM. Programmable Products. Seller shall responsible user's programming programmable Good, consequence thereof. Performance Data. Performance data given this catalog provided guide user determining suitability does constitute warranty. represent result Seller's test conditions, user must correlate actual application requirements. Actual performance subject Seller's Warranty Limitations Liability. Change Specifications. Product specifications accessories changed time based improvements other reasons. practice change part numbers when published ratings features changed, when significant construction changes made. However, some specifications Good changed without notice. When doubt, special part numbers assigned establish specifications your application. Please consult with your Seller's representative time confirm actual specifications purchased Good. Errors Omissions. information this catalog been carefully checked believed accurate; however, responsibility assumed clerical, typographical proofreading errors, omissions. 2-stage Digital Timer H5CX-B Complete "Terms Conditions Sale" product purchase Omron's website www.omron.com/oei under "About tab, Legal Matters section. DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. OMRON ELECTRONICS Commerce Drive Schaumburg, 60173 OMRON CANADA, INC. Milner Avenue Toronto, Ontario OMRON ON-LINE Global http://www.omron.com http://www.omron.com/oei Canada http://www.omron.ca 847-843-7900 technical support other inquiries: 416-286-6465 800-556-6766 Cat. L101-E3-01 10/03 Specifications subject change without notice Printed 2-stage Digital Timer H5CX-B Other recent searchesTLV2620 - TLV2620 TLV2620 Datasheet TLV2621 - TLV2621 TLV2621 Datasheet TLV2622 - TLV2622 TLV2622 Datasheet TLV2623 - TLV2623 TLV2623 Datasheet TLV2624 - TLV2624 TLV2624 Datasheet TLV2625 - TLV2625 TLV2625 Datasheet SN74LVC2G79 - SN74LVC2G79 SN74LVC2G79 Datasheet NBSG11 - NBSG11 NBSG11 Datasheet LDC20 - LDC20 LDC20 Datasheet EN25P40 - EN25P40 EN25P40 Datasheet 2SC1573 - 2SC1573 2SC1573 Datasheet 2SC1573A - 2SC1573A 2SC1573A Datasheet 2SC1573B - 2SC1573B 2SC1573B Datasheet 2SA0879 - 2SA0879 2SA0879 Datasheet 2SA879 - 2SA879 2SA879 Datasheet
Privacy Policy | Disclaimer |