| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
AAT2806 dual charge pump designed support both white backlight flash a
Top Searches for this datasheetDual High Efficiency Charge Pump White Flash Applications General Description AAT2806 dual charge pump designed support both white backlight flash applications systems operating with lithium-ion/polymer batteries. backlight charge pump capable driving four LEDs total 80mA. current sinks operated individually parallel driving higher current LEDs. maximize power efficiency, charge pump operates 1.5X, mode, where mode operation automatically selected comparing forward voltage each with input voltage. AnalogicTech's S2Cwire(Simple Serial ControlTM) serial digital input used enable, disable, current each with eight-level logarithmic scale plus four low-current settings down 50µA optimized efficiency, with typical operating quiescent current less than 50µA. flash charge pump charge pump doubler with regulated output voltage. designed deliver 120mA continuous current 250mA pulsed current. independent enable improved power savings. AAT2806 thermal protection built-in soft-start circuitry. low-current shutdown feature disconnects load from reduces quiescent current less than 1µA. AAT2806 available Pb-free, space-saving, thermally-enhanced TDFN44-16 package rated over -40°C +85°C temperature range. AAT2806 ChargePump Range: 2.7V 5.5V Dual Charge Pump Support Backlight Flash LEDs Backlight Charge Pump: Regulated Current Four Current Sink Inputs S2Cwire Brightness Control Tri-Mode Charge Pump Maximum 20mA Current Input (50µA) Light Load Mode Flash Charge Pump: Regulated Output Voltage 250mA Pulsed Current Independent Backlight/Flash Control Noise 1MHz Constant Frequency Operation Automatic Soft Start Inductors Available TDFN44-16 Package Applications Color (RGB) Lighting White Backlighting White Photo Flash Typical Application C3VOUT_FL COUT VOUT_FLASH Flash AAT2806 VOUT_BL Backlight EN/SET EN_FLSH EN/SET EN_FLSH COUT 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Descriptions AAT2806 Symbol C3C3+ VOUT_FL EN/SET C1VOUT_BL C2EN_FLSH Function Flying capacitor negative terminal. Flying capacitor positive terminal. Connect capacitor between C3-. Regulated output voltage flash LED. Requires capacitor connected between this ground. Input power supply. Requires capacitor connected between this ground. Current sink input Current sink input Current sink input Current sink input Ground. S2Cwire serial interface control pin. used enable/disable backlight charge pump control brightness white LEDs. Flying capacitor positive terminal. Connect capacitor between C1-. Flying capacitor negative terminal. Regulated output voltage white LEDs. Requires capacitor connected between this ground. Flying capacitor positive terminal. Connect capacitor between C2-. Flying capacitor negative terminal. Enable/disable flash charge pump. Exposed paddle (bottom); connect directly beneath package. Configuration TDFN44-16 (Top View) C3C3+ VOUT_FL EN_FLSH C2C2+ VOUT_BL C1C1+ EN/SET 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Absolute Maximum Ratings1 Symbol VEN/SET; EN_FL TLEAD AAT2806 Description Input Voltage EN/SET; EN_FL Voltage Maximum Soldering Temperature leads, sec) Value -0.3 -0.3 Units Thermal Information2 Symbol Description Maximum Power Dissipation Maximum Thermal Resistance Value Units °C/W Stresses above those listed Absolute Maximum Ratings cause permanent damage device. Functional operation conditions other than operating conditions specified implied. Only Absolute Maximum Rating should applied time. Mounted board. Derate 6.25mW/°C above 25°C. 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Electrical Characteristics1 3.6V; COUT 1.0µF; -40°C +85°C, unless otherwise noted. Typical values 25°C. Symbol AAT2806 Description Operation Range Conditions Units 4.68 Input Power Supply ISHDN I(D-Match) RSINK VOUT_FL IOUT_FL FCLK VEN(L) VEN(H) TEN/SET TEN/SET_HI_MIN TEN/SET_HI_MAX TOFF TLAT Mode, 5.5, Active, Load Current; EN_FLSH GND, EN/SET 1.5X Mode, 5.5, Active, Load Current; EN_FLSH GND, EN/SET Mode, 5.5, Active, Load Operating Current Current; EN_FLSH GND, EN/SET EN_FLSH GND, 50µA Output Setting, Mode 5.5, Load Current; EN_FLSH VIN, EN/SET Shutdown Current EN_FLSH EN/SET Input Current Accuracy ISET 20mA ISET 4.1mA; 25°C Current Matching Between VD1:D4 3.6V, 3.5V Current Sink Inputs2, Sink Switch Impedance (each)2 3.0V IOUT 100mA; 4.32 Flash Charge Pump Output EN_FLSH 3.0V IOUT 150mA; Voltage EN_FLSH Maximum Continuous IOUT5 3.6V; VOUT 4.5V; EN_FLSH Maximum Pulsed IOUT5 3.6V; VOUT 4.5V; IPULSED 500ms Soft-Start Time Clock Frequency Enable Threshold Enable Threshold High EN/SET Time Minimum EN/SET High Time Maximum EN/SET High Time EN/SET Timeout EN/SET Latch Timeout Enable EN/SET Input -1.0 Leakage AAT2806 guaranteed meet performance specifications over -40°C +85°C operating temperature range assured design, characterization, correlation with statistical process controls. Specification applies only tri-mode charge pump. Determined average active channels. Current matching defined deviation sink current from average active channels. Specification applies only charge pump doubler. 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Typical Characteristics- Flash Driver Charge Pump Section Output Voltage Output Current (VOUT_FL 4.5V; EN_FL VIN; EN/SET GND) 4.60 AAT2806 Maximum Current Pulse Supply Voltage (VOUT_FL 4.5V; EN_FL VIN; EN/SET GND) Maximum Current Pulse (mA) Output Voltage 4.56 4.52 4.48 4.44 One-shot pulse duration 250ms VOUT 4.0V 3.6V 3.0V 2.7V 3.3V 4.40 10.0 100.0 1000.0 Output Current (mA) Supply Voltage Start-Up Time (50mA Load) Start-Up Time (100mA Load) EN_FLSH (1V/div) EN_FLSH (1V/div) VOUT_FL (1V/div) VOUT_FL (1V/div) Time (100µs/div) Time (100µs/div) Load Response Time (50mA Load) 3.5V VOUT_FL (10mV/div) VOUT_FL (10mV/div) Load Response Time (100mA Load) 3.5V IOUT (20mA/div) IOUT (50mA/div) Time (5ms/div) Time (5ms/div) 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Typical Characteristics- Flash Driver Charge Pump Section Output Ripple Voltage Time (IOUT 50mA 3.5V) (10mV/div) VOUT (10mV/div) (10mV/div) VOUT (20mV/div) AAT2806 Output Ripple Voltage Time (IOUT 100mA 3.5V) (10mA/div) (10mA/div) Time (500ns/div) Time (500ns/div) Supply Current Supply Voltage IOUT VEN_FL Oscillator Frequency Supply Voltage Oscillator Frequency (MHz) 1.30 3.00 Supply Current (mA) 2.75 2.50 2.25 2.00 1.75 1.50 1.25 1.00 1.25 +25°C 1.20 +85°C -40°C 1.15 1.10 Supply Voltage Supply Voltage 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Typical Characteristics- White Backlight Driver Section Turn-On Mode (VIN 4.2V; 20mA Load) AAT2806 Turn-On 1.5X Mode (VIN 3.5V; 20mA Load) (2V/div) (2V/div) VSINK (500mV/div) (200mA/div) Time (100µs/div) (2V/div) (2V/div) VSINK (500mV/div) (200mA/div) Time (100µs/div) Turn-On Mode (VIN 2.8V; 20mA Load) (2V/div) (1V/div) Turn-Off from 1.5X Mode (VIN 3.5V; 20mA Load) (2V/div) (2V/div) VSINK (500mV/div) (200mA/div) (100mA/div) Time (100µs/div) Time (500µs/div) Efficiency Supply Voltage 10mA 3.1V 20mA 3.4V 20.4 20.2 Current Matching Temperature Channel Channel Channel Channel Efficiency Current (mA) 20.0 19.8 19.6 19.4 19.2 19.0 Supply Voltage Temperature (°C) 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Typical Characteristics- White Backlight Driver Section Load Characteristics (VIN 3.7V; 1.5X Mode; 14mA Load) AAT2806 Load Characteristics (VIN 2.7V; Mode; 14mA Load) (40mV/div) (40mV/div) (40mV/div) (40mV/div) VSINK (40mV/div) VSINK (40mV/div) Time (500ns/div) Time (500ns/div) Load Characteristics (VIN 3.9V; 1.5X Mode; 20mA Load) Load Characteristics (VIN 2.9V; Mode; 20mA Load) (40mV/div) (40mV/div) VSINK (40mV/div) (40mV/div) (40mV/div) VSINK (40mV/div) Time (500ns/div) Time (500ns/div) EN/SET Latch Timeout Input Voltage EN/SET Latch Timeout EN/SET Timeout Input Voltage EN/SET Timeout -40°C -40°C 25°C 85°C 25°C 85°C Input Voltage Input Voltage 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Typical Characteristics- White Backlight Driver Section Input Ripple Input Voltage Enable Threshold High AAT2806 Enable Threshold High Input Voltage Amplitude (mV) 2.50 2.67 2.84 3.01 3.18 3.35 3.52 3.69 3.86 4.03 4.20 -40°C 20mA 25°C 85°C 10mA Input Voltage Input Voltage Enable Threshold Input Voltage Enable Threshold -40°C 25°C 85°C Input Voltage 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Functional Block Diagram Soft-Start AAT2806 EN_FLSH 1MHz Oscillator Charge Pump VOUT_FLSH VREF Soft-Start Control 1MHz Oscillator Voltage Reference 1.5X Charge Pump C1C2+ C2VOUT_BL EN/SET Control Logic Functional Description AAT2806 dual charge pump designed flash white applications. backlight charge pump tri-mode load switch (1X) high efficiency (1.5X charge pump device. maximize power conversion efficiency, internal sensing circuit monitors voltage required each constant current sink input sets load switch charge pump modes based input battery voltage current sink input voltage. battery voltage discharges over time, white charge pump enabled when four current sink inputs near dropout. charge pump initially starts 1.5X mode. charge pump output drops enough current source output become close dropout, charge pump will automatically transition mode. four constant current sink inputs drive four individual LEDs with maximum current 20mA LED. unused sink inputs must connected VOUT_BL; otherwise, part will operate only charge pump mode. S2Cwire serial interface enables sets constant current sink magnitudes. S2Cwire addressing allows main channels controlled independently from sub-channel 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications flash charge pump charge pump doubler with regulated output voltage. designed deliver 120mA continuous current 250mA pulsed current. AAT2806 requires external components: three ceramic capacitors charge pump flying capacitors (C1, C3), ceramic input capacitor (CIN), 0.33µF ceramic capacitor backlight charge pump output capacitor (COUT), ceramic capacitor flash charge pump output capacitor (COUT). IOUT (mA) D1-D3 Sub-Group 0.05 0.05 AAT2806 Data Constant Current Output Level Settings constant current level channels S2Cwire serial interface (see Table Because inputs true independent constant current sinks, voltage observed single given input will determined difference between VOUT actual forward voltage (VF) being driven. Since constant current levels programmable, (pulse width modulation) additional control circuitry needed control brightness. This feature greatly reduces burden microcontroller system manage display brightness, allowing user "set forget it." With high-speed serial interface (>1MHz data rate), current drive changed successively brighten LEDs, smooth transitions (e.g., fade-out) abrupt steps, giving user complete programmability realtime control brightness. AAT2806 offers additional Current mode with reduced quiescent current (Data 16). This mode especially useful low-current applications where continuous, low-current state maintained. reduction quiescent current significantly reduces impact maintaining continuous backlighting state. Table Constant Current Programming Levels. S2Cwire Serial Interface current sink input magnitude backlight charge pump controlled AnalogicTech's S2Cwire serial digital input. interface relies number rising edges EN/SET address load registers. S2Cwire latches data address after EN/SET been held high time TLAT. interface records rising edges EN/SET decodes them into different states, indicated Table There four brightness levels main sub-display group with possibility individually turning each group. further optimize power efficiency, device also offers four low-current levels operation (Data 16). During this low-current mode, internal supply current reduces only 50µA typical. counter clocked speeds 1MHz, such that intermediate states visible. first rising edge EN/SET enables initially sets output current 20mA. Once final clock cycle input desired brightness level, EN/SET held high maintain device output current programmed level. device disabled 500µs (TOFF) after EN/SET transitions logic state. 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications S2Cwire Serial Interface Timing Diagram TLAT TOFF AAT2806 EN/SET Data Disabled Current Sinks backlight charge pump equipped with auto-disable feature protect against failure condition. Current sink inputs that used should disabled. disable properly terminate unused current sink inputs, they must tied VOUT. left unconnected terminated ground, part will forced operate charge pump mode. Properly terminating unused current sink inputs important prevent charge pump modes from activating prematurely. When properly terminated, only small sense current flows each disabled channel. sense current each disabled channel less than 10µA. some instances (e.g., high-luminous-output applications such photo-flash), necessary drive high-VF type LEDs. low-dropout current-sinks AAT2806 make capable driving LEDs with forward voltages high 4.3V full current from input supply 3.0V. Outputs paralleled drive high-current LEDs without complication. Device Switching Noise Performance AAT2806 operates fixed frequency approximately 1MHz control noise limit harmonics that interfere with operation cellular telephone handsets other communication devices. Back-injected noise appearing input charge pump 20mV peak-to-peak, typically times less than inductor-based DC/DC boost converter white backlight solutions. AAT2806 soft-start feature prevents noise transient effects associated with inrush currents during startup charge pump circuit. Applications Information Selection AAT2806 specifically intended driving white LEDs. However, device design will allow AAT2806 drive most types LEDs with forward voltage specifications ranging from 2.0V 4.3V. applications include main display backlighting, camera photo-flash applications, color (RGB) LEDs, infrared (IR) diodes remotes, other loads benefiting from controlled output current generated from varying input voltage. Since input current sinks matched with negligible voltage dependence, brightness will matched regardless specific forward voltage (VF) levels. Capacitor Selection Careful selection external capacitors CIN, COUT (for backlight flash) important because they will affect turn-on time, output ripple, transient performance. Optimum performance will obtained when equivalent series resistance (ESR) ceramic capacitors used. general, defined less than 100m. value capacitors good starting point when choosing capacitors. 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Capacitor Characteristics Ceramic composition capacitors highly recommended over other types capacitors with AAT2806. Ceramic capacitors offer many advantages over their tantalum aluminum electrolytic counterparts. ceramic capacitor typically very ESR, lowest cost, smaller footprint, non-polarized. ceramic capacitors help maximize charge pump transient response. Since ceramic capacitors non-polarized, they prone incorrect connection damage. AAT2806 Charge Pump Power Efficiency Backlight Charge Pump: charge pump efficiency discussion following sections only accounts efficiency charge pump section itself. unique circuit architecture, very difficult measure efficiency terms percent value comparing input power over output power. Since outputs pure constant current sinks typically drive individual loads, difficult measure output voltage given output derive overall output power measurement. given application, white forward voltage levels differ, output drive current will maintained constant. This makes quantifying output power difficult task when taken context comparing other white driver circuit topologies. better quantify total device efficiency observe total input power device given current drive level. best white driver given application should based trade-offs size, external components count, reliability, operating range, total energy usage.not just efficiency." Efficiency AAT2806 quantified under very specific conditions dependent upon input voltage versus output voltage seen across loads applied outputs through given constant current setting. Depending combination voltages sensed current sinks, device will operate load switch mode. When voltages sensed current sinks nears dropout, device will operate 1.5X charge pump mode. Each these modes will yield different efficiency values. Refer following sections explanations each operational mode. Load Switch Mode Efficiency: load switch mode operational times functions alone enhance device power conversion efficiency when greater than voltage across load. When load switch mode, voltage conversion efficiency defined output power divided input power: Equivalent Series Resistance important characteristic consider when selecting capacitor. resistance internal capacitor that caused leads, internal connections, size area, material composition, ambient temperature. Capacitor typically measured milliohms ceramic capacitors range more than several ohms tantalum aluminum electrolytic capacitors. Ceramic Capacitor Materials Ceramic capacitors less than 0.1µF typically made from materials. materials generally have tight tolerance very stable over temperature. Larger capacitor values usually composed X7R, X5R, Z5U, dielectric materials. Large ceramic capacitors (i.e., greater than 2.2µF) often available lowcost dielectrics, capacitors greater than typically required AAT2806 applications. Capacitor area another contributor ESR. Capacitors that physically large will have lower when compared equivalent material smaller capacitor. These larger devices improve circuit transient response when compared equal value capacitor smaller package size. Thermal Protection AAT2806 thermal protection circuit that will shut down charge pumps temperature rises above thermal limit. POUT 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications expression define ideal efficiency rewritten POUT VOUT IOUT VOUT IOUT AAT2806 VOUT charge pump with output nominal input 3.5V, theoretical efficiency 95%. internal switching losses quiescent current consumption, actual efficiency measured 93%. These figures close agreement output load conditions from 100mA. Efficiency will decrease load current drops below 0.05mA when level approaches VOUT. Flash Charge Pump: flash charge pump regulated output voltage doubling charge pump. efficiency defined linear voltage regulator with effective output voltage that equal times input voltage. expression define ideal efficiency written POUT VOUT IOUT VOUT 2.0IOUT 2.0VIN Charge Pump Mode Efficiency: Fractional charge pumps will boost input supply voltage event where less than voltage required constant current source outputs. efficiency simply defined linear voltage regulator with effective output voltage that equal half times input voltage. Efficiency ideal 1.5X charge pump typically expressed output power divided input power: VOUT 2.0VIN POUT addition, with ideal 1.5X charge pump, output current expressed input current. expression define ideal efficiency rewritten VOUT IOUT VOUT POUT 1.5IOUT 1.5VIN charge pump with output nominal input theoretical efficiency 83.3%. internal switching losses quiescent current consumption, actual efficiency measured approximately 82%. Efficiency will decrease level approaches that regulated VOUT. Refer device typical characteristics curves expected actual efficiency based either input voltage load current. VOUT 1.5VIN 2806.2006.04.1.8 Dual High Efficiency Charge Pump White Flash Applications Ordering Information Package TDFN44-16 AAT2806 Marking1 NPXYY Part Number (Tape Reel)2 AAT2806IXN-4.5-T1 AnalogicTech products offered Pb-free packaging. term "Pb-free" means semiconductor products that compliance with current RoHS standards, including requirement that lead exceed 0.1% weight homogeneous materials. more information, please visit website Package Information Index Area (D/2 E/2) TDFN44-16 Detail 4.00 0.05 3.30 0.05 0.10 0.16 0.375 0.125 0.075 0.075 Detail View Bottom View Indicator (optional) 7.5° 7.5° 0.05 -0.20 0.229 0.051 Detail Option C0.30 (4x) Chamfered corner Option R0.30 (4x) Round corner 0.05 0.05 Side View dimensions millimeters. Detail assembly date code. Sample stock generally held part numbers listed BOLD. 2806.2006.04.1.8 0.23 0.05 0.45 0.05 4.00 0.05 2.60 0.05 Dual High Efficiency Charge Pump White Flash Applications AAT2806 Advanced Analogic Technologies, Inc. AnalogicTech cannot assume responsibility circuitry other than circuitry entirely embodied AnalogicTech product. circuit patent licenses, copyrights, mask work rights, other intellectual property rights implied. AnalogicTech reserves right make changes their products specifications discontinue product service without notice. Customers advised obtain latest version relevant information verify, before placing orders, that information being relied current complete. products sold subject terms conditions sale supplied time order acknowledgement, including those pertaining warranty, patent infringement, limitation liability. AnalogicTech warrants performance semiconductor products specifications applicable time sale accordance with AnalogicTech's standard warranty. Testing other quality control techniques utilized extent AnalogicTech deems necessary support this warranty. Specific testing parameters each device necessarily performed. AnalogicTech AnalogicTech logo trademarks Advanced Analogic Technologies Incorporated. other brand product names appearing this document registered trademarks trademarks their respective holders. Advanced Analogic Technologies, Inc. Arques Avenue, Sunnyvale, 94085 Phone (408) 737-4600 (408) 737-4611 2806.2006.04.1.8 Other recent searchesTN6707A - TN6707A TN6707A Datasheet PCN12895 - PCN12895 PCN12895 Datasheet LS-40EB - LS-40EB LS-40EB Datasheet IXR100 - IXR100 IXR100 Datasheet FMC7G50US60 - FMC7G50US60 FMC7G50US60 Datasheet 74AC86 - 74AC86 74AC86 Datasheet 2N7002K - 2N7002K 2N7002K Datasheet
Privacy Policy | Disclaimer |