Top Searches for this datasheetSmart Motor Controllers SMC-2 Cat. 150-A05. 150-A09. 150-A16. 150-A24. 150-A35. 150-A54. 150-A68. 150-A97. Electrical Ratings Rated Operating Current Maximum Heat Dissipation (Watts) Power Terminals 1.5.6 1.5.6 1.5.6 Cable #14.#12 #14.#12 #14.#12 Size Interface Option Terminals #1/0 Rated Operational Voltage 200.240, 380.480, 500.600V 50/60 3-phase (+10%, -15%) Thermal Capacity (S1), NEMA 100/120V 200/240V, 50/60 1-phase Interface Option Voltage (+10%, -15%) Power Requirements Maximum Heatsink Auxiliary Contact Rating NEMA C300 AC-15 Electrical Design Specifications/Test Requirements Repetitive Peak Inverse Voltage Rating Selectable Soft Start Times Current Limit Times Selectable Across-the-Line Starting Soft Stop Times Noise Immunity DV/DT Protection Transient Protection (Optional) Vibration Shock Construction Power Poles: Control: Metal Parts: Power Terminals: Control Terminals: Power Terminal Markings: Wiring Adjustments Modes Protection 1200V 240V Line, 1400V 480V Line, 1600V 600V Line seconds seconds 1/10 second seconds Surge Transient Peak 3400V. Showering 1500V Snubber Network Metal Oxide Varistors: joules) minutes mSecs High temperature thermoplastic moldings Thermoplastic moldings Anodized aluminum, plated brass, copper hole with clamping plate 6-32 Screw with self-tilting clamp plate CENELEC EN50 012, NEMA Mechanical Design Specifications/Test Requirements Terminals Functional Design Standard Set-up Features Starting SMC-2 Controller without options wired series with motor starter. SMC-2 Controller configured with switches rotary digital switch. Soft Start, Current Limit, Full Voltage unit. controller pre-start protection from phase loss shorted SCRs. provided indicate status unit. when 3-phase power applied. flashing indicates conditions: shorted phase loss during start, stalled motor during run. Protection Stall protection available during starting condition additional motor protection. Energy Level Built-in energy saver available load conditions. 3-wire control wider variety applications. Interface option requires additional space Wiring factory field installed. Auxiliary Selectable auxiliary contact available either up-to-speed instantaneous operation. Contact Module allows soft stopping minimize load shifting. Also adjusted from standard switches. Operating Storage 0°C.+50°C (32°F.+122°F) Running Optional Set-up Interface Features Starting Stopping Environmental Temperature Altitude Humidity -40°C.+85°C (-40°F.+185°F) 2000 meters (6560 feet) 5.95% Relative Humidity (non-condensing) Fuse Clip Sizing Type Fusible Combination Controllers Horsepower 480V Fuse Clip Size/Type A/Class A/Class A/Class A/Class A/Class A/Class A/Class A/Class Fuse Size Range 0.30 31.60 31.60 31.60 61.100 61.100 101.200 101.200 Consult Handbook proper fuse sizing guidelines. Optional fuse clip sizes types available upon request. Consult Allen-Bradley Sales Office. Product Selection Page Other recent searchesTDA2170 - TDA2170 TDA2170 Datasheet MSM6295 - MSM6295 MSM6295 Datasheet DS1307 - DS1307 DS1307 Datasheet 1308 - 1308 1308 Datasheet DS5000 - DS5000 DS5000 Datasheet DEMO908GZ60 - DEMO908GZ60 DEMO908GZ60 Datasheet 74LVC16245A - 74LVC16245A 74LVC16245A Datasheet 74LVCH16245A - 74LVCH16245A 74LVCH16245A Datasheet
Privacy Policy | Disclaimer |