| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
S-87x Series S-87x Series low-power high withstandvoltage regulat
Top Searches for this datasheetHIGH WITHSTAND-VOLTAGE REGURATOR WITH RESET FUNCTION S-87x Series S-87x Series low-power high withstandvoltage regulators with reset function, which integrates high-precision voltage detection voltage regulation circuits single chip. S-87x Series lineups lithium-ion battery packs. Features Accuracy output voltage: ±2.4 (0.1 step) Accuracy detection voltage: ±2.4 (For type, release voltage ±1.1 11.3 (0.1 step) voltage difference: 0.15 typ. IOUT=30 VOUT=5.0 0.45 typ. IOUT=30 VOUT=3.0 current consumption: Operation mode: max. Shutdown mode: max. (Available C/E/G type) Wide operating voltage range: max. Wide operating temperature range: -40°C +85°C Built-in delay circuit shutdown circuit Built-in short-circuit protection circuit Small package: SOT-89-5 Applications Constant voltage power supply reset circuit battery-powered equipment, VTR, camera, communications equipment others. Lithium-ion secondary battery pack Package SOT-89-5 (Package drawing code: UP005-A) Seiko Instruments HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Rev.6.1_10 Block Diagrams type Short-circuit protection circuit Voltage regulator VOUT Voltage detection circuit Delay circuit Figure type Short-circuit protection circuit Voltage regulator VOUT Voltage detection circuit Delay circuit Figure Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series type Short-circuit protection circuit Voltage regulator VOUT Voltage detection circuit Shutdown circuit Figure type Short-circuit protection circuit Voltage regulator Power on/off VOUT SENSE Voltage detection circuit Figure Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series type Short-circuit protection circuit Voltage regulator VOUT Voltage detection circuit Shutdown circuit Figure Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Product Code Structure Function list Table Type name type type type type type type Voltage detector (VD) Detects Detects VOUT Detects Detects VSENSE Detects Detects VOUT Detection voltage (-VDET) accuracy ±2.4 ±2.4 ±2.4 ±2.4 ±2.4 Release voltage (+VDET) accuracy ±1.1 Built-in delay circuit Shutdown function Product name selection guide S-87 direction tape sepecifications Product name (Abbreviation) Package name (Abbreviation) SOT-89-5 Product type Built-in delay circuit, detection (-VDET detection) Built-in delay circuit, VOUT detection Built-in shudown circuit regulator, detection Built-in shudown circuit regulator, VSENSE detection Built-in delay circuit, detection (+VDET detection) Built-in shudown circuit regulator, VOUT detection Detection voltage voltage detector (Ex. When detection voltage voltage detector expressed Output voltage voltage regulator (Ex. When output voltage voltage regulator expressed 26.) Refer taping specifications this document. Refer Table Table Product name list". 10.0 11.0 11.3 Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Product name list Table (1/2) output voltage detection voltage 11.0 S-87xxxxA Series S-875077AUP-AAF-T2 S-875045AUP-AAA-T2 S-875043AUP-AAB-T2 S-875041AUP-AAC-T2 S-875039AUP-AAD-T2 S-875037AUP-AAE-T2 S-873377AUP-0AA-T2 S-873328AUP-0AB-T2 S-873025AUP-ADA-T2 S-873024AUP-ADB-T2 S-873023AUP-ADC-T2 S-873022AUP-ADD-T2 S-873021AUP-ADE-T2 S-87xxxxB Series S-875635BUP-AGA-T2 S-875045BUP-ABA-T2 S-875043BUP-ABB-T2 S-875041BUP-ABC-T2 S-875039BUP-ABD-T2 S-875037BUP-ABE-T2 S-875034BUP-ABF-T2 S-875029BUP-ABH-T2 S-875021BUP-ABG-T2 S-873325BUP-ALA-T2 S-873025BUP-AEA-T2 S-873024BUP-AEB-T2 S-873023BUP-AEC-T2 S-873022BUP-AED-T2 S-873021BUP-AEE-T2 S-872622BUP-OLA-T2 S-87xxxxC Series S-875294CUP-AHC-T2 S-875271CUP-AHA-T2 S-875255CUP-AHB-T2 S-8750B0CUP-ACG-T2 S-875077CUP-ACF-T2 S-875061CUP-ACH-T2 S-875045CUP-ACA-T2 S-875043CUP-ACB-T2 S-875041CUP-ACC-T2 S-875039CUP-ACD-T2 S-875037CUP-ACE-T2 S-873361CUP-AOH-T2 S-873069CUP-AFF-T2 S-873059CUP-AFG-T2 S-873025CUP-AFA-T2 S-873024CUP-AFB-T2 S-873023CUP-AFC-T2 S-873022CUP-AFD-T2 S-873021CUP-AFE-T2 Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Table (2/2) detection S-87xxxxE Series S-87xxxxG Series voltage S-8750B0EUP-AJI-T2 11.0 S-875087EUP-AJG-T2 S-875077EUP-AJF-T2 S-875061EUP-AJH-T2 S-875037GUP-ANE-T2 S-875033EUP-AJA-T2 S-875030EUP-AJB-T2 S-8733B0EUP-APC-T2 11.0 S-8733A0EUP-APF-T2 10.0 S-873372EUP-APE-T2 S-873348EUP-APD-T2 S-873330EUP-APB-T2 11.3 S-8730B3EUP-AMF-T2 S-873082EUP-AMC-T2 S-873062EUP-AMB-T2 S-873050EUP-AME-T2 S-873042EUP-AMD-T2 Caution S-87xxxxB/S-87xxxxG Series, when output voltage voltage regulator close detection voltage voltage detector, transient response voltage regulator cause false detection. Please take transient response into account when deciding voltages. Table output voltage release voltage S-87xxxxF Series S-875087FUP-AKA-T2 output voltage Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Rev.6.1_10 Configuration SOT-89-5 view Table Symbol VOUT (A/B/F type) (C/G type) SENSE type) description Voltage output voltage regulator Ground Connection external capacitor delay voltage detector Input shutdown circuit Voltage monitoring voltage detector Output voltage detector, opendrain output Positive power-supply Figure Absolute Maximum Ratings Table Item Input voltage Symbol (A/B/F type) (Unless otherwise specified: Ta=25°C) Absolute maximum rating Unit VSS-0.3 VSS+26 (C/G type) VSENSE type) Output voltage VOUT VSS-0.3 VIN+0.3 Output voltage voltage detector VSS-0.3 VSS+26 Power dissipation Operating ambient temperature Topr Storage ambient temperature Tstg +125 Even pulse (µs) noise exceeding above input voltage (VSS+26 damage Observe rated input voltage (VSS+26 Caution absolute maximum ratings rated values exceeding which product could suffer physical damage. These values must therefore exceeded under conditions. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Electrical Characteristics S-8750xxA Series/S-8750xxB Series Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Voltage Detector Operating voltage Delay time Tempertue characteristic -VDET Detection voltage Symbol VOUT Vdif VOUT1 VOUT2 VOUT Vopr VDET -VDET Condition VIN=7 IOUT=30 IOUT=30 VIN=6 IOUT=30 VIN=7 IOUT=50 VIN=7 IOUT=30 Ta=-40°C +85°C CD=4.7 Ta=-40°C +85°C S-875045A/B S-875043A/B S-875041A/B S-875039A/B S-875037A/B S-875021B Nch, VIN=1.3 VDS=0.5 VIN=2.4 VIN=3.6 Nch, VDS=24 VIN=10 S-875045A/B S-875043A/B S-875021A/B Input current Current consumption VIN=7 Unloaded (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 4.88 4.392 4.196 4.001 3.806 3.611 2.049 0.25 1.50 3.00 -VDET -VDET 5.00 0.15 ±0.38 ±0.5 4.50 4.30 4.10 3.90 3.70 2.10 0.60 2.60 4.50 5.12 0.40 ±1.52 ±2.0 4.608 4.404 4.199 3.994 3.789 2.151 -VDET -VDET Sink current IDOUT Leakage current Hysteresis width ILEAK VHYS (ms)=(3.18 min., 5.74 typ., 8.73 (nF) Excluding charging current Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series S-8730xxA Series/S-8730xxB Series Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Voltage Detector Operating voltage Delay time Temperature characteristic -VDET Detection voltage Symbol VOUT Vdif VOUT1 VOUT2 VOUT Vopr VDET -VDET Condition VIN=5 IOUT=30 IOUT=30 VIN=4 IOUT=30 VIN=5 IOUT=50 VIN=5 IOUT=30 Ta=-40°C +85°C CD=4.7 Ta=-40°C +85°C S-873025A/B S-873024A/B S-873023A/B S-873022A/B S-873021A/B Nch, VIN=1.3 VDS=0.5 Other than below VIN=2.4 S-873025A/B Nch, VDS=24 VIN=10 VIN=5 Unloaded (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 2.928 2.440 2.342 2.244 2.147 2.049 0.25 1.50 -VDET 3.000 0.45 ±0.23 ±0.3 2.500 2.400 2.300 2.200 2.100 0.60 2.60 3.072 0.70 ±0.92 ±1.2 2.560 2.458 2.356 2.253 2.151 -VDET Sink current IDOUT Leakage current Hysteresis width Input current Current consumption ILEAK VHYS (ms)=(3.18 min., 5.74 typ., 8.73 (nF) Excluding charging current Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series S-875635B Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Voltage Detector Operating voltage Delay time Temperature characteristic -VDET Detection voltage Sink current Leakage current Hysteresis width Input current Current consumption Symbol VOUT Vdif VOUT1 VOUT2 VOUT Vopr VDET -VDET IDOUT ILEAK VHYS Condition VIN=7.6 IOUT=30 IOUT=30 VIN=6.6 IOUT=30 VIN=7.6 IOUT=50 VIN=7.6 IOUT=30 Ta=-40°C +85°C CD=4.7 Ta=-40°C +85°C Nch, VIN=1.3 VDS=0.5 VIN=2.4 Nch, VDS=24 VIN=10 VIN=7.6 Unloaded (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 5.465 3.416 0.25 1.50 -VDET 5.60 0.15 ±0.43 ±0.3 3.50 0.60 2.60 5.735 0.40 ±1.72 ±1.2 3.584 -VDET (ms)=(3.18 min., 5.74 typ., 8.73 (nF) Excluding charging current Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series S-873325B Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Voltage Detector Operating voltage Delay time Temperature characteristic -VDET Detection voltage Sink current Leakage current Hysteresis width Input current Current consumption Symbol VOUT Vdif VOUT1 VOUT2 VOUT Vopr VDET -VDET IDOUT ILEAK VHYS Condition VIN=5.3 IOUT=30 IOUT=30 VIN=4.3 IOUT=30 VIN=5.3 IOUT=50 VIN=5.3 IOUT=30 Ta=-40°C +85°C CD=4.7 Ta=-40°C +85°C Nch, VDS=0.5 VIN=1.3 Nch, VDS=24 VIN=10 VIN=5.3 Unloaded (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 3.220 2.440 0.25 -VDET 3.300 0.45 ±0.25 ±0.2 2.500 0.60 3.380 0.70 ±1.00 ±0.8 2.560 -VDET (ms)=(3.18 min., 5.74 typ., 8.73 (nF) Excluding charging current Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series S-8750xxC Series/S-875037G Table (1/2) Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Shutdown output voltage Voltage Detector Operating voltage Temperature characteristic -VDET Symbol VOUT Vdif VOUT1 VOUT2 VOUT VOUT/OFF Vopr VDET Condition VIN=7 IOUT=30 IOUT=30 VIN=6 IOUT=30 VIN=7 IOUT=50 VIN=7 IOUT=30 Ta=-40°C +85°C VIN=7 ="L", RL=1 Ta=-40°C S-8750B0C +85°C S-875077C S-875061C S-875037C, S-875037G S-8750B0C S-875077C S-875061C S-875045C S-875043C S-875041C S-875039C S-875037C/S-875037G Nch, VIN=1.3 VDS=0.5 VIN=2.4 VIN=3.6 VIN=10 Nch, S-875077C VDS=24 S-875037C, S-875037G VIN=15 S-8750B0C S-875045C S-8750B0C S-875061C, S-875043C S-875037C, S-875037G (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 4.88 10.736 7.515 5.953 4.392 4.196 4.001 3.806 3.611 0.25 1.50 3.00 5.00 0.15 ±0.38 ±0.8 ±0.6 ±0.5 11.00 7.70 6.10 4.50 4.30 4.10 3.90 3.70 0.60 2.60 4.50 5.12 0.40 ±1.52 ±3.2 ±2.4 ±2.0 11.264 7.885 6.247 4.608 4.404 4.199 3.994 3.789 Detection voltage -VDET Sink current IDOUT Leakage current ILEAK Hysteresis width VHYS -VDET -VDET -VDET -VDET Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Table (2/2) Item Input current Current consumption VIN=7 Unloaded S-8750B0C S-875061C S-875045C S-875037C, S-875037G Symbol Condition (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit Shutdown input voltage ="L", Shutdown, VIN=7 ="L", Shutdown, VIN=7 ="H", Power VIN=7 Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series S-8730xxC Series Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Shutdown output voltage Voltage Detector Operating voltage Temperature characteristic -VDET Detection voltage Symbol VOUT Vdif VOUT1 VOUT2 VOUT VOUTOFF Vopr VDET -VDET Ta=-40°C +85°C Condition VIN=5 IOUT=30 IOUT=30 VIN=4 IOUT=30 VIN=5 IOUT=50 VIN=5 IOUT=30 Ta=-40°C +85°C VIN=5V, ="L", RL=1 S-873069C S-873025C S-873021C (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 2.928 6.734 2.440 2.342 2.244 2.147 2.049 0.25 1.50 3.00 -VDET 3.000 0.45 ±0.23 ±0.5 ±0.3 6.900 2.500 2.400 2.300 2.200 2.100 0.60 2.60 4.50 3.072 0.70 ±0.92 ±2.0 ±1.2 7.066 2.560 2.458 2.356 2.253 2.151 -VDET Sink current IDOUT Leakage current Hysteresis width Input current Current consumption Input Voltage Shutdown input voltage ILEAK VHYS S-873069C S-873025C S-873024C S-873023C S-873022C S-873021C Nch, VIN=1.3 VDS=0.5 Other than below VIN=2.4 S-873069C, S-873025C VIN=3.6 S-873069C Nch, VDS=24 VIN=10 VIN=5 Unloaded ="L", Shutdown, VIN=5 ="L", Shutdown, VIN=5 ="H", Power VIN=5 Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series S-875271C, S-875255C Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Shutdown output voltage Voltage Detector Operating voltage Temperature characteristic -VDET Detection voltage Sink current Symbol VOUT Vdif VOUT1 VOUT2 VOUT VOUTOFF Vopr VDET -VDET IDOUT Condition VIN=7.2 IOUT=30 IOUT=30 VIN=6.2 IOUT=30 VIN=7.2 IOUT=50 VIN=7.2 IOUT=30 Ta=-40°C +85°C VIN=7.2V, ="L", RL=1 Ta=-40°C S-875271C +85°C S-875255C S-875271C S-875255C Nch, VIN=1.3V VDS=0.5 VIN=2.4V VIN=3.6V Nch, VDS=24 VIN=10 VIN=7.2 Unloaded ="L", Shutdown, VIN=7.2 ="L", Shutdown, VIN=7.2 ="H", Power VIN=7.2 (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 5.075 6.929 5.368 0.25 1.50 3.00 -VDET 5.20 0.15 ±0.40 ±0.5 ±0.4 7.10 5.50 0.60 2.60 4.50 5.325 0.40 ±1.60 ±2.0 ±1.6 7.271 5.632 -VDET Leakage current Hysteresis width Input current Current consumption ILEAK VHYS Input Voltage Shutdown input voltage Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series S-875294C Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Shutdown output voltage Voltage Detector Operating voltage Temperature characteristic -VDET Detection voltage Sink current Leakage current Hysteresis width Input current Current consumption Symbol VOUT Vdif VOUT1 VOUT2 VOUT VOUTOFF Vopr VDET -VDET IDOUT ILEAK VHYS Input Voltage Shutdown input voltage Nch, VDS=0.5 Condition VIN=14.4 IOUT=30 IOUT=30 VIN=6.2 IOUT=30 VIN=14.4 IOUT=50 VIN=14.4 IOUT=30 Ta=-40°C +85°C VIN=14.4 ="L", RL=1 Ta=-40°C +85°C VIN=1.3 VIN=2.4 VIN=3.6 Nch, VDS=24 VIN=10 VIN=14.4 Unloaded ="L", Shutdown,, VIN=14.4 ="L", Shutdown, VIN=14.4 ="H", Power VIN=14.4 (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 5.075 9.174 0.25 1.50 3.00 -VDET 5.20 0.15 ±0.40 ±0.7 9.40 0.60 2.60 4.50 5.325 0.40 ±1.60 ±2.8 9.626 -VDET Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series S-873361C Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Shutdown output voltage Voltage Detector Operating voltage Temperature characteristic -VDET Detection voltage Sink current Symbol VOUT Vdif VOUT1 VOUT2 VOUT VOUTOFF Vopr VDET -VDET IDOUT Nch, VDS=0.5 Condition VIN=5.3 IOUT=30 IOUT=30 VIN=4.3 IOUT=30 VIN=5.3 IOUT=50 VIN=5.3 IOUT=30 Ta=-40°C +85°C VIN=5.3 ="L", RL=1 Ta=-40°C +85°C VIN=1.3 VIN=2.4 VIN=3.6 Nch, VDS=24 VIN=10 VIN=5.3 Unloaded ="L", Shutdown, VIN=5.3 ="L", Shutdown, VIN=5.3 ="H", Power VIN=5.3 (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 3.220 5.953 0.25 1.50 3.00 -VDET 3.300 0.45 ±0.25 ±0.5 6.100 0.60 2.60 4.50 3.380 0.70 ±1.00 ±2.0 6.247 -VDET Leakage current Hysteresis width Input current Current consumption ILEAK VHYS Input Voltage Shutdown input voltage Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series S-8750xxE Series Table (Unless otherwise specified: Ta=25°C, Connect SENSE pin.) Test Symbol Condition Min. Typ. Max. Unit circuit VOUT Vdif VOUT1 VOUT2 VOUT VOUTOFF Vopr VDET -VDET IDOUT VIN=7 IOUT=30 VSENSE=-VDET (Typ.)+2 IOUT=30 VSENSE=-VDET (Typ.)+2 VIN=6 IOUT=30 VSENSE=-VDET (Typ.)+2 VIN=7 IOUT=50 VSENSE=-VDET (Typ.)+2 VIN=7 IOUT=30 Ta=-40°C +85°C, VSENSE=-VDET (Typ.)+2 VIN=-VDET (Typ.)-1V, RL=1 Ta=-40°C +85°C S-875077E S-875061E Nch, VDS=0.5 S-875077E S-875061E 4.88 7.515 5.953 0.25 1.50 3.00 -VDET 5.00 0.15 ±0.38 ±0.6 ±0.5 7.70 6.10 0.60 2.60 4.50 5.12 0.40 ±1.52 ±2.4 ±2.0 7.885 6.247 -VDET Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Output voltage during voltage detection Voltage Detector Operating voltage Temperature characteristic -VDET Detection voltage Sink current VIN=1.3 VIN=2.4 VIN=3.6 Leakage current SENSE input current ILEAK lSENSE Nch, VDS=24 VIN=-VDET (Typ.) VIN=7 S-875077E VSENSE=-VDET (Typ.) S-875061E VIN=-VDET (Typ.)+2 S-875077E Unloaded S-875061E VIN=-VDET (Typ.)-1 Shutdown Hysteresis width Input current Current consumption VHYS Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series S-8730xxE Series Table (Unless otherwise specified: Ta=25°C, Connect SENSE pin.) Test Symbol Condition Min. Typ. Max. Unit circuit VOUT Vdif VOUT1 VOUT2 VOUT VOUTOFF Vopr VDET -VDET IDOUT VIN=5 IOUT=30 VSENSE=-VDET (Typ.)+2 IOUT=30 VSENSE=-VDET (Typ.)+2 VIN=4 IOUT=30 VSENSE=-VDET (Typ.)+2 VIN=5 IOUT=50 VSENSE=-VDET (Typ.)+2 VIN=5 IOUT=30 Ta=-40°C +85°C, VSENSE=-VDET (Typ.)+2 VIN=-VDET (Typ.)-1 RL=1 Ta=-40°C +85°C S-873082E S-873062E Nch, VDS=0.5 VIN=1.3 VIN=2.4 VIN=3.6 S-873082E S-873062E 2.928 8.003 6.051 0.25 1.50 3.00 -VDET 3.000 0.45 ±0.23 ±0.6 ±0.5 8.200 6.200 0.60 2.60 4.50 3.072 0.70 ±0.92 ±2.4 ±2.0 8.397 6.349 -VDET Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Output voltage during voltage detection Voltage Detector Operating voltage Temperature characteristic -VDET Detection voltage Sink current Leakage current SENSE input current Hysteresis width Input current Current consumption ILEAK lSENSE Nch, VDS=24 VIN=-VDET (Typ.)+2 VIN=5 S-873082E VSENSE=-VDET (Typ.)+ S-873062E VIN=-VDET (Typ.)+2 Unloaded VIN=-VDET (Typ.)-1 Shutdown VHYS Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series S-873330E Table (Unless otherwise specified: Ta=25°C, Connect SENSE pin.) Test Symbol Condition Min. Typ. Max. Unit circuit VOUT Vdif VOUT1 VOUT2 VOUT VOUTOFF Vopr VDET -VDET IDOUT ILEAK lSENSE VHYS VIN=5.3 IOUT=30 VSENSE=-VDET (Typ.)+2 IOUT=30 VSENSE=-VDET (Typ.)+2 VIN=4.3 IOUT=30 VSENSE=-VDET (Typ.)+2 VIN=5.3 IOUT=50 VSENSE=-VDET (Typ.)+2 VIN=5.3 IOUT=30 Ta=-40°C +85°C, VSENSE=-VDET (Typ.)+2 VIN=-VDET (Typ.)-1 RL=1 Ta=-40°C +85°C Nch, VIN=1.3 VDS=0.5 VIN=2.4 Nch, VDS=24 VIN=-VDET (Typ.)+2 VIN=5.3 VSENSE=-VDET (Typ.)+2 VIN=-VDET (Typ.)+2 Unloaded VIN=-VDET (Typ.)-1 Shutdown 3.220 2.928 0.25 1.50 -VDET 3.300 0.45 ±0.25 ±0.2 3.000 0.60 2.60 3.380 0.70 ±1.00 ±0.8 3.072 -VDET Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Output voltage during voltage detection Voltage Detector Operating voltage Temperature characteristic -VDET Detection voltage Sink current Leakage current SENSE input current Hysteresis width Input current Current consumption Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series S-875087F Table Item Voltage Regulator Output voltage voltage difference Line regulation Load regulation Input voltage Temperature coefficient VOUT Voltage Detector Operating voltage Delay time Symbol VOUT Vdif VOUT1 VOUT2 VOUT Vopr VDET +VDET Condition VIN=7 IOUT=30 IOUT=30 VIN=6 IOUT=30 VIN=7 IOUT=50 VIN=7 IOUT=30 Ta=-40°C +85°C CD=4.7 Ta=-40°C +85°C Nch, VDS=0.5 VIN=1.3 VIN=2.4 VIN=3.6 (Unless otherwise specified: Ta=25°C) Test Min. Typ. Max. Unit circuit 4.88 5.00 0.15 ±0.38 5.12 0.40 ±1.52 8.600 0.25 1.50 3.00 0.085 ±0.7 8.700 0.60 2.60 4.50 ±2.8 8.800 0.215 Release voltage Temperature Release voltage (Overcharge detection voltage) Sink current Leakage current Hysteresis width Input current Current consumption IDOUT ILEAK VHYS Nch, VDS=24 VIN=15 VIN=7 Unloaded (ms)=(3.18min., 5.74typ., Excluding charging current Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Test Circuits VOUT (SENSE) VPF) (SENSE) VPF) VOUT Figure VOUT (SENSE) VPF) Figure VOUT Figure (SENSE) Figure VOUT VPF) (SENSE) RL=1 Figure SENSE Figure Figure Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Rev.6.1_10 Operation Timing Charts Voltage regulator (C/G type) VOUT Indicates shutdown state. When load current (IOUT) less than output voltage (VOUT) always level. When VOUT shorted VOUT becomes level. When short VOUT removed VOUT returns normal output. Figure Voltage detector (A/B/F type) VOUT +VDET -VDET VHYS Output delay time (tpd) voltage detector changed with external capacitance value pin. Delay circuit included C/E/G type. Remark Pull through resistor VOUT. Figure Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series When using SENSE type) VIN=VSENSE*1 +VDET -VDET VOUT SENSE connected pin. Remark Pull through resistor VOUT. Figure Technical Terms voltage difference (Vdif) Vdif=VIN1-VOUT1 VOUT1: Initial output voltage VIN1: Input voltage which generates output voltage (VOUT2) decreased from VOUT1 Load regulation (VOUT2) VOUT2=VOUT1-VOUT2 VOUT1: Output voltage when IOUT VOUT2: Output voltage when IOUT Line regulation (VOUT1) VOUT1=VOUT1-VOUT2 VOUT1: Output voltage when VOUT2: Output voltage when (VOUT+1) Hysteresis width (VHYS) VHYS=(+VDET)-(-VDET) +VDET: Release voltage -VDET: Detection voltage Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Rev.6.1_10 Operation Reference voltage circuit reference voltage circuit operates time when voltage applied affected signal. Voltage regulator Figure shows voltage regulator circuit. S-87x Series transistor output control transistor. Reverse current break VOUT potential higher than VIN, because parasitic diode formed between VOUT structure control transistor. Therefore, keep VOUT lower than VIN+0.3 output voltage voltage regulator selected follows: V±2.4 (0.1 step) VREF VOUT Parasitic diode Figure Voltage regulator circuit Caution application with load current less than leakage current control transistor increases output voltage. Short-circuit protection circuit S-87x Series built-in short-circuit protection circuit protect element from break caused large current case short circuit. output short current internally limited approx. Short-circuit protection circuit three kinds characteristics according input voltage (VIN) shown Figure Output: VIN/VOUT2.0 VOUT 1.5VIN/VOUT<2.0 VOUT VIN/VOUT<1.5 VOUT Imax IOUT [mA] IOUT [mA] IOUT [mA] Figure Figure Figure Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Delay circuit delay circuit outputs voltage detector output (VOR) with delay after voltage become release voltage (+VDET) rising pin. Figure when exceeds reference voltage (Vref), output voltage detection voltage output (VOR) changes from high level, providing delay output. When voltage falls under detection voltage (-VDET), transistor turns therefore charge external capacitor (CD) rapidly discharged voltage detector output (VOR) changes from high level without delay. external capacitor (CD) charged with constant current, practically independent voltage. delay time (tpd) expressed following equation: (ms)=Delay coefficient (3.18 min., 5.74 typ., 8.73 (nF) Vref Figure Caution Unless output delay needed, keep open. apply external voltage other than ground potential pin, which cause breakdown. When designing your printed-circuit board layout, take care that leakage current flows external capacitor (CD), otherwise correct delay time obtained. Because value constant current source (IC) only impedance high. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Voltage detection circuit built-in voltage detection circuit (Nch opendrain type) equivalent S-808 Series/S-809 Series voltage detectors. pull-up resistor about required output. Since comparator power this circuit supplied from pin, this circuit operates while voltage applied pin. detection voltage voltage detector selected follows: 11.3 V±2.4 (0.1 step) type, release voltage (+VDET) accuracy ±1.1 responds application overcharge detection lithium-ion battery packs. type, input voltage monitoring voltage detector externally connected SENSE pin. Because this configured resistor only, temporary current such through-type current does flow. Consequently even when resistor (RIN) inserted between input power supply pin, input power voltage accurately monitored connecting SENSE input power supply. Also, when drop SENSE input voltage detected, voltage detector generates reset signal. same time, powers voltage regulator. Caution shown Figure when connecting output type connecting SENSE type, following phenomena occur resistor (RIN) connected between input voltage pin. careful. time voltage detection, voltage regulator shutdown load current cut. Therefore, voltage increases where current flowing into IIN. Hence, exceeds hysterisis width (VHYS), oscillation starts immediately after detection continues. necessary less than VHYS. time voltage release, voltage regulator powered load current flows. Therefore, exceeds hysterisis width (VHYS), oscillation starts immediately after release continues. necessary less than VHYS. Also time voltage release, rush current charge output capacitor (COUT) flows. Hence, oscillation momentarily starts until output regulator (VOUT) rises high enough even though less than VHYS. Short-circuit protection circuit controls rush current less than IMAX Figure this momentary oscillation problem your applicaion, setting less than VHYS/IMAX prevents oscillation. VOUT S-87xxxxCUP COUT Figure Attention connecting example Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series VOUT S-87xxxxEUP SENSE COUT Figure Attention connecting example Power Voltage Voltage +VDET -VDET VHYS drop rush current Figure When VIN>VHYS type, minimum operating voltage becomes voltage. drop voltage occurs load current rush current charged output capacitor when load current voltage regulator powered time release, more. Also, type, when sharply increasing only voltage ms/V less, with SENSE fixed -VDETVSENSE-VDET-2 release pulse output output voltage detector. careful. this case, this release pulse removed setting time constant more with capacitance pull-up resistance. addition, when voltage SENSE fixed between detection voltage release voltage detect condition, sharply increasing only voltage ms/V less, output detector turns release condition. this action problem your system, please connect SENSE pin. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Shutdown circuit (C/E/G type) When goes (0.4 less) type time voltage detection type current voltage regulator shut down, current consumption (excluding current which flows through pull-up resistor) lowers less. During shutdown, transistor voltage regulator shown Figure VOUT pulled down whose value (R1+R2) Input current less. Caution output voltage become when load which makes IOUT under connected during shutdown. keep floating state medium potential (between high levels). Otherwise through-type current flows. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Transient Characteristics undershoot overshoot occur output voltage voltage regulator input voltage load current fluctuates transiently. undershoot large, voltage detector operates output reset signal type which voltage detector detects output voltage regulator. overshoot large, load circuit adversely affected. Therefore important determine capacitor value minimize undershoot overshoot. Line: Transient characteristics input voltage fluctuation Input voltage fluctuation differs depending types signal applied: type which rectangular wave between (VOUT+1) type which rectangular wave from (Refer Figure ringing waveforms parameter dependency each type described below. measuring circuit shown Figure reference. Input voltage (VOUT+1) Overshoot Undershoot Output voltage deviation Fiogure Rectangular wave between (VOUT+1) (Type Input voltage Overshoot Output voltage deviation Remark Rise/fall time (time between Figure Rectangular wave from (Type Fast amplifier S-87x Series P.G. VOUT CL*1 Oscilloscope 10:1 probe Undershoot electrolytic capacitor Figure Measuring circuit Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Type (Rectangle wave between (VOUT+1) IOUT=40 CL=10 Ta=25°C Input voltage V/div] (VOUT+1) Output voltage [200 mV/div] ms/div Overshoot amount: Undershoot amount: Figure Ringing waveform (Type Table Parameter dependency (Type Series S-8750xxx Parameter Load current (IOUT) Load capacitance (CL) Input fluctuation (VIN Conditions CL=10 IOUT=40 CL=10 IOUT=40 Method decrease Method decrease overshoot undershoot Decrease Decrease Increase Increase Decrease Decrease Increase Decrease temperature temperature Increase Decrease Increase Increase Increase Decrease temperature temperature Temperature (Ta) Load current (IOUT) Load capacitance (CL) Input fluctuation (VIN Temperature (Ta) High voltage value voltage value S-8730xxx reference, following pages describe ringing VOUT measured using output load current (IOUT), output load capacitance (CL), input fluctuation width (VIN), temperature (Ta) parameters. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Reference Data: Type S-8750xxx Series IOUT Dependency Ringing amount [mV] IOUT [mA] CL=10 Ta=25°C Dependency 1600 Ringing amount [mV] 1400 1200 1000 [µF] IOUT=40 Ta=25°C Dependency Ringing amount [mV] IOUT=40 CL=10 Ta=25°C Temperature Dependency Ringing amount [mV] [°C] IOUT=40 CL=10 Undershoot Overshoot Remark lower voltage fixed S-8730xxx Series IOUT Dependency Ringing amount [mV] IOUT [mA] CL=10 Ta=25°C Dependency 1600 1400 1200 1000 [µF] Ringing amount [mV] IOUT=40 Ta=25°C Dependency Ringing amount [mV] IOUT=40 CL=10 Ta=25°C Temperature Dependency Ringing amount [mV] IOUT=40 CL=10 Undershoot Overshoot [°C] Remark lower voltage fixed Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Type (Rectangle wave form IOUT=40 CL=10 Ta=25°C Input voltage V/div] Output voltage [500 mV/div] ms/div Overshoot amount: 1300 Undershoot amount: Figure Ringing waveform (Type Table Parameter dependency (Type Series S-8750xxx Parameter Conditions CL=10 IOUT=40 CL=10 IOUT=40 Method decrease Method decrease overshoot undershoot Increase Increase Decrease Decrease Increase Increase temperature temperature Increase Increase Decrease Decrease Increase Increase temperature temperature Load current (IOUT) Load capacitance (CL) Input fluctuation (VIN Temperature (Ta) S-8730xxx Load current (IOUT) Load capacitance (CL) Input fluctuation (VIN Temperature (Ta) High voltage value reference, following pages describe ringing VOUT measured using output load current (IOUT), output load capacitance (CL), input fluctuation width (VIN), temperature (Ta) parameters. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Reference Data: Type S-8750xxx Series IOUT Dependency Ringing amount [mV] CL=10 Ta=25°C Dependency Ringing amount [mV] [µF] IOUT=40 Ta=25°C IOUT [mA] Dependency Ringing amount [mV] IOUT=40 CL=10 Ta=25°C Temperature Dependency Ringing amount [mV] [°C] IOUT=40 CL=47 Undershoot Overshoot Remark lower voltage fixed S-8730xxxSeries IOUT Dependency Ringing amount [mV] CL=10 Ta=25°C Dependency Ringing amount [mV] IOUT=40 Ta=25°C IOUT [mA] [µF] Dependency Ringing amount [mV] IOUT=40 CL=10 Ta=25°C Temperature Dependency Ringing amount [mV] IOUT=40 CL=10 [°C] Overshoot Undershoot Remark lower voltage fixed Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Load transient response characteristics load current fluctuation overshoot undershoot caused output voltage load current changed from while input voltage kept constant. Figure shows output voltage fluctuation change load current. measuring circuit shown Figure reference. latter half this section describes ringing waveform parameter dependency. Load current Output Voltage deviation Overshoot Undershoot Figure Output voltage fluctuation change load current S-87x Series VOUT Power supply CL*3 Oscilloscope 10:1 probe VOUT VOUT electrolytic capacitor Figure Measuring circuit Table Parameter dependency load current fluctuation Series S-8750xxx, S-8730xxx Parameter Load current (IOUT) Load capacitance (CL) Power supply voltage (VIN) Temperature (Ta) Method decrease Method decrease overshoot undershoot Decrease Decrease CL=10 Increase Increase IOUT=40 Increase Increase (VOUT+1) temperature temperature Conditions Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Reference Data S-8750xxxSeries IOUT Dependency Ringing amount [mV] IOUT [mA] CL=10 Ta=25°C, VIN=10 Dependency Ringing amount [mV] [µF] VIN=10 Ta=25°C Remark lower current fixed Dependency CL=10 Ta=25°C Ringing amount [mV] Temperature Dependency Ringing amount [mV] CL=10 VIN=10 Undershoot Overshoot [°C] S-8730xxxSeries IOUT Dependency IOUT [mA] CL=10 Ta=25°C, VIN=10 Ringing amount [mV] Dependency Ringing amount [mV] VIN=10 Ta=25°C Remark lower current fixed Dependency CL=10 Ta=25°C Ringing amount [mV] Ringing amount [mV] [µF] Temperature Dependency VIN=10 Undershoot Overshoot [°C] Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Rev.6.1_10 Standard Circuits A/B/F type VOUT VOUT Figure type VOUT VOUT Figure type SENSE VOUT VOUT Figure Caution above connection diagram constants guarantee correct operation. Perform sufficient evaluation using actual application constants. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Application Circuits Microcomputer power supply reset circuit construct microcomputer power supply reset circuit using conventional ICs, voltage regulator voltage detector delay time generation circuit others required. type allows make these circuits without these ICs, delay time variable. VOUT VOUT RESET Figure Caution above connection diagram constants guarantee correct operation. Perform sufficient evaluation using actual application constants. Output current boost circuit transistor used increase output current. type VOUT VOUT Figure Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series type VOUT VOUT Figure Caution above connection diagram constants guarantee correct operation. Perform sufficient evaluation using actual application constants. Power supply lithium-ion battery pack When lithium-ion battery goes down overdischarge voltage, built-in voltage detector powers voltage regulator, same time transmits RESET signal microcomputer. attached eliminate voltage exceeding absolute maximum ratings charger. attached give delay release RESET signal after power supply voltage microcomputer (VOUT) rises high enough. Charger VOUT S-87xxxxE SENSE Series Micro-computer RESET Figure Caution above connection diagram constants guarantee correct operation. Perform sufficient evaluation using actual application constants. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Power Dissipation Package voltage regulator under specified power dissipation package. Power dissipation (PD) Unassembled case Glass epoxy board (1.7 thick) Copper foiled area:1 Ambient temperature (Ta) [°C] Figure Precautions apply ripple voltage following both conditions pin. (cycle) f1000 VPP0.5 ("f" shows frequency) Figure When connecting another power supply voltage regulator output pin, insert diode protect VOUT Figure apply electrostatic discharge this that exceeds performance ratings built-in electrostatic protection circuit. Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series Rev.6.1_10 Typical Characteristics Voltage regulator Output voltage (VOUT) Temperature (Ta) characteristics S-8750xxx Series 5.10 VOUT 5.05 5.00 4.95 4.90 [°C] VOUT S-8730xxx Series 3.10 3.05 3.00 2.95 2.90 [°C] Line regulation(VOUT1) Temperature (Ta) characteristics S-8750xxx Series VOUT1 [mV] VOUT1 [mV] [°C] S-8730xxx Series [°C] Input voltage (VIN) Output voltage (VOUT) characteristics S-8750xxx Series S-8730xxx Series VOUT VOUT IOUT=50 IOUT=50 Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Load regulation(VOUT2) Temperature (Ta) characteristics S-8750xxx Series VOUT2 (mV) VOUT2 [mV] [°C] S-8730xxx Series [°C] voltage difference (Vdif) Temperature (Ta) characteristics S-8750xxx Series Vdif [mV] Vdif [mV] S-8730xxx Series [°C] [°C] Short-circuit protection circuit characteristics S-8750xxx Series (Ta=25°C) 6.00 5.00 VOUT VOUT VIN=24 6.00 5.00 4.00 3.00 2.00 1.00 0.00 VIN=10 4.00 3.00 2.00 1.00 0.00 VIN=8 VIN=6 IOUT [mA] 6.00 5.00 VOUT IOUT [mA] 6.00 5.00 VOUT 4.00 3.00 2.00 1.00 4.00 3.00 2.00 1.00 0.00 IOUT [mA] 0.00 IOUT [mA] Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series S-8730xxx Series (Ta=25°C) 4.00 VOUT 3.00 2.00 1.00 0.00 S-8730xxx Series VIN=24 4.00 VOUT 3.00 2.00 1.00 0.00 IOUT [mA] IOUT [mA] 4.00 VOUT 3.00 2.00 1.00 0.00 VIN=6 4.00 VOUT 3.00 2.00 1.00 VIN=4 IOUT [mA] 0.00 IOUT [mA] Ripple rejection characteristics S-8750xxx Series VIN=7 IOUT=40 CL=10 Gain [db] [HZ] 100k S-8730xxx Series VIN=5 IOUT=40 CL=10 Gain [db] [HZ] 100k Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Voltage detector Detection voltage (VDET) Temperature (Ta) characteristics S-875045 VDET [mV] [°C] VDET [mV] S-875043 [°C] S-873023 VDET [mV] [°C] Hysteresis width (VHYS) Temperature (Ta) characteristics S-875045 VHYS VHYS [°C] S-875043 [°C] S-873023 VHYS [°C] Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION S-87x Series transistor output current (IDOUT) characteristics Ta=25°C IDOUT [mA] VIN=3.6 VIN=2.4 VIN=1.3 Delay time (tpd) characteristics Delay time (tpd) Temperature (Ta) [ms] [°C] VIN=10 CD=4.7 Total Current consumption (Iss) characteristics Input voltage(VIN) characteristics S-8750xxC Series [µA] Ta=25°C [µA] S-8730xxC Series Ta=25°C Current consumption (Iss) Temperature (Ta) characteristics S-8750xxC Series S-8730xxC Series [µA] [°C] VIN=7 [µA] [°C] VIN=5 Seiko Instruments Inc. HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION Rev.6.1_10 S-87x Series Input voltage shutdown circuit characteristics High level input voltage (VIH) Temperature (Ta) level input voltage (VIL) Temperature (Ta) characteristics characteristics [°C] Ta=25°C VIH, VIN=6 0.75 0.25 [°C] VIN=6 VIH, Power supply voltage dependency characteristics Seiko Instruments Inc. 4.5±0.1 1.6±0.2 1.5±0.1 1.5±0.1 1.5±0.1 0.4±0.05 0.4±0.1 0.45±0.1 0.4±0.1 UP005-A-P-SD-1.1 TITLE SCALE UNIT SOT895-A-PKG Dimensions UP005-A-P-SD-1.1 Seiko Instruments Inc. +0.1 2.0±0.05 4.0±0.1(10 pitches 40.0±0.2) max. +0.1 8.0±0.1 0.3±0.05 2.0±0.1 4.75±0.1 Feed direction UP005-A-C-SD-1.1 TITLE SCALE UNIT SOT895-A-Carrier Tape UP005-A-C-SD-1.1 Seiko Instruments Inc. 16.5max. 13.0±0.3 Enlarged drawing central part (60°) (60°) UP005-A-R-SD-1.1 TITLE SCALE UNIT SOT895-A-Reel UP005-A-R-SD-1.1 QTY. 1,000 Seiko Instruments Inc. information described herein subject change without notice. Seiko Instruments Inc. responsible problems caused circuits diagrams described herein whose related industrial properties, patents, other rights belong third parties. application circuit examples explain typical applications products, guarantee success specific mass-production design. When products described herein regulated products subject Wassenaar Arrangement other agreements, they exported without authorization from appropriate governmental authority. information described herein other purposes and/or reproduction copying without express permission Seiko Instruments Inc. strictly prohibited. products described herein cannot used part device equipment affecting human body, such exercise equipment, medical equipment, security systems, equipment, apparatus installed airplanes other vehicles, without prior written permission Seiko Instruments Inc. Although Seiko Instruments Inc. exerts greatest possible effort ensure high quality reliability, failure malfunction semiconductor products occur. user these products should therefore give thorough consideration safety design, including redundancy, fire-prevention measures, malfunction prevention, prevent accidents, fires, community damage that ensue. Other recent searchesXRA00 - XRA00 XRA00 Datasheet ULN2001A - ULN2001A ULN2001A Datasheet ULN2002A - ULN2002A ULN2002A Datasheet ULN2003A - ULN2003A ULN2003A Datasheet ULN2004A - ULN2004A ULN2004A Datasheet UFT-1 - UFT-1 UFT-1 Datasheet SUD70N02-05P - SUD70N02-05P SUD70N02-05P Datasheet NCP629 - NCP629 NCP629 Datasheet MN100363-X - MN100363-X MN100363-X Datasheet GL5501GL551 - GL5501GL551 GL5501GL551 Datasheet GL550 - GL550 GL550 Datasheet GL551 - GL551 GL551 Datasheet CDC208 - CDC208 CDC208 Datasheet ADSP-21065L - ADSP-21065L ADSP-21065L Datasheet
Privacy Policy | Disclaimer |