POLARIZED RELAY SINGLE SIDE STABLE FEATURES profile compact board


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



AZ832
POLARIZED RELAY SINGLE SIDE STABLE
FEATURES profile compact board spacing coils High sensitivity, pickup Life expectancy million operations High switching capacity, Fits standard socket Epoxy sealed automatic wave soldering cleaning Meets Part 68.302 1500 lightning surge Meets Part 68.304 1000 dielectric file E43203 GENERAL DATA
DPDT Form Bifurcated crossbar contacts Resistive load: Max. switched power: Max. switched current: Max. switched voltage:
*Note: switching voltage greater than VDC, special precautions must taken. Please contact factory.
CONTACTS
Arrangement Ratings
Life Expectancy Mechanical Electrical Operate Time (typical) Release Time (typical) Bounce (typical)
Minimum operations nominal coil voltage nominal coil voltage (with coil suppression) 1500 Vrms contact coil 1000 Vrms between contact sets 1000 Vrms across contacts Meets Part 68.302 lightning surge Meets Part 68.304 dielectric 1000 megohms min. 20°C, VDC, Greater than nominal coil voltage nominal coil voltage -40°C (-40°F) 85°C (185°F) -40°C (-40°F) 115°C (239°F) 10-500 P.B.T. polyester Tinned copper alloy, P.C. 270°C (518°F) seconds 80°C (176°F) seconds grams
Rated Load Material
resistive resistive Gold plated silver against palladium silver. Gold plated palladium silver against palladium silver (Suffix "A") Gold plated silver against gold plated silver (Suffix approved) milliohms initially
Dielectric Strength level)
Insulation Resistance Dropout Ambient Temperature Operating Storage
Resistance
COIL
Power Pickup Voltage (typical) Max. Continuous Dissipation Temperature Standard coil: Sensitive coil: 20°C (68°F) Max. 115°C (239°F)
Vibration Shock Enclosure Terminals Max. Solder Temp. Max. Solder Time Max. Solvent Temp. Max. Immersion Time Weight
NOTES
values 20°C (68°F). Relay pull with less than "Must Operate" value. Relay fixed coil polarity. complete isolation between relay's magnetic fields, recommended that .197" (5.0 space provided between adjacent relays. Relay adjustment affected undue pressure exerted relay case. Specifications subject change without notice.
7/24/02W
AZ832
RELAY ORDERING DATA
ULTRA SENSITIVE COIL COIL SPECIFICATIONS
Nominal Coil Max. Continuous 12.3 14.5 21.0 29.0 43.5 57.0 Coil Resistance 2160 3840 Must Operate 14.4 19.2
ORDER NUMBER*
AZ832-2C-5DSE AZ832-2C-6DSE AZ832-2C-9DSE AZ832-2C-12DSE AZ832-2C-18DSE AZ832-2C-24DSE
SENSITIVE COIL COIL SPECIFICATIONS
Nominal Coil Max. Continuous 10.6 12.7 19.1 25.5 38.3 50.9 101.8 Coil Resistance 45.0 1620 2,880 11,520 Must Operate 14.4 19.2 38.4
ORDER NUMBER*
AZ832-2C-3DE AZ832-2C-5DE AZ832-2C-6DE AZ832-2C-9DE AZ832-2C-12DE AZ832-2C-18DE AZ832-2C-24DE AZ832-2C-48DE
STANDARD COIL COIL SPECIFICATIONS
Nominal Coil Max. Continuous 11.0 23.2 34.8 44.6 93.7 Coil Resistance 1350 2210 9750 Must Operate 2.25 3.75 13.5 18.0 36.0
ORDER NUMBER*
AZ832-2C-3DME AZ832-2C-5DME AZ832-2C-6DME AZ832-2C-12DME AZ832-2C-18DME AZ832-2C-24DME AZ832-2C-48DME
NON-SENSITIVE COIL COIL SPECIFICATIONS
Nominal Coil Max. Continuous 12.5 17.8 26.7 34.4 67.3 Coil Resistance 1050 4000 Must Operate 12.6 16.8 33.6
ORDER NUMBER*
AZ832-2C-5DHE AZ832-2C-6DHE AZ832-2C-9DHE AZ832-2C-12DHE AZ832-2C-18DHE AZ832-2C-24DHE AZ832-2C-48DHE
*Add suffix gold plated palladium silver against palladium silver contact material. suffix gold plated silver against gold plated silver contact material (not approved).
7/24/02W
AZ832
MECHANICAL DATA
MECHANICAL DATA
.048 [1.21] .795 MAX. [20.20] .394 MAX. [10.00]
BOARD LAYOUT
.300 [7.62]
.047 [1.19]
.026 [0.66]
.419 MAX. [10.65]
.300 [7.62]
.118 [3.00]
.048 [1.21] .024±.005 [0.61±0.12] .012±.005 [0.30±0.12]
.200 [5.08]
.024 REF. [0.61]
WIRING DIAGRAM
.012 REF. [0.30]
.300 [7.62]
(WATCH POLARITY) VIEWED TOWARD TERMINALS
Dimensions inches with metric equivalents parentheses. Tolerance: .010"
7/24/02W

Other recent searches


ZVA-183+ - ZVA-183+   ZVA-183+ Datasheet
V6123 - V6123   V6123 Datasheet
UEL162 - UEL162   UEL162 Datasheet
STG4159 - STG4159   STG4159 Datasheet
SN67061 - SN67061   SN67061 Datasheet
JDC-20-3-75+ - JDC-20-3-75+   JDC-20-3-75+ Datasheet
HM514265C - HM514265C   HM514265C Datasheet
2SA1006 - 2SA1006   2SA1006 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive