| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
INNOVATION EXCELLENCE Dual Output A-Series, Models A-SE
Top Searches for this datasheetINNOVATION EXCELLENCE Dual Output A-Series, Models A-SERIES High-Reliability, 15-20 Watt, DC/DC Converters Features cost! Highly reliable! Proven SMT-on-pcb construction Qual tested; HALT tested; tested Designed meet EN60950, BASIC insulation (48VIN models) mark available (48VIN models) Output voltages: Volts Ultra-wide input voltage ranges: 4.7-7.5V, 9-36V 18-75V Small packages, 0.45" Industry-standard pinouts Fully isolated, 1500Vdc guaranteed Guaranteed efficiencies +100°C operating temperature Modifications customs OEM's your mid-range power requirements, it's hard beat combination cost, proven reliability outstanding electrical performance offered 15-20W, dual-output models DATEL's A-Series DC/DC converters. These highly efficient, rugged converters combine straightforward circuit topologies, newest components, proven SMT-on-pcb construction methods, highly repeatable automatic-assembly techniques. Their superior durability substantiated rigorous in-house qualification program that includes HALT (Highly Accelerated Life Testing). ultra-wide input voltage ranges A-Series duals (4.7-7.5V "D5A" models, 9-36V "D12A" models 18-75V "D48A" models) make them excellent candidates battery-powered systems distributed power architectures. Their Volt outputs cover virtually standard applications. These popular power converters fully isolated (1500Vdc guaranteed) display excellent line load regulation (with specs ±0.3% max. line ±0.5% max. load). They completely protected (input overvoltage shutdown reverse-polarity protection, output current limiting overvoltage protection) contain input type) output filtering reduce noise. They require external components offer true "plug-and-play" convenience. These extremely reliable, cost-effective power converters housed standard 0.45" metal packages coated with electrically non-conductive materials. They offer industry-standard pinouts ideally suited high-volume computer, telecom/datacom, instrumentation applications. +VIN +VOUT COMMON -VIN -VOUT ON/OFF CONTROL CONTROLLER OPTO ISOLATION REFERENCE ERROR TRIM Figure Simplified Schematic DATEL, Inc., Mansfield, 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 Email: sales@datel.com Internet: www.datel.com Series Performance Specifications Ordering Guide Output Model BWR-5/1500-D5A BWR-5/1700-D12A BWR-5/1700-D48A BWR-12/625-D5A BWR-12/830-D12A BWR-12/830-D48A BWR-15/500-D5A BWR-15/670-D12A BWR-15/670-D48A Input Regulation (Max.) Line ±0.5% ±0.3% ±0.3% ±0.5% ±0.3% ±0.4% ±0.5% ±0.3% ±0.3% VOUT (Volts) IOUT (mA) ±1500 ±1700 ±1700 ±625 ±830 ±830 ±500 ±670 ±670 (mVp-p) Typ. Max. Load ±1.0% ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% Nom. (Volts) Range (Volts) 4.7-7.5 9-36 18-75 4.7-7.5 9-36 18-75 4.7-7.5 9-36 18-75 (mA) 75/3750 15/753 15/377 75/3750 30/1000 15/510 75/3659 30/979 15/484 Efficiency Min. 80.5% 81.5% Typ. Package (Case, Pinout) Typical +25°C under nominal line voltage full-load conditions unless otherwise noted. Ripple/Noise (R/N) measured over 20MHz bandwidth. Balanced loads, 100% load. Nominal line voltage, no-load/full-load conditions. 2.00 (50.80) Output Configuration: Bipolar Wide Range Input Nominal Output Voltages: Volts A-Series High Reliability Input Voltage Range: 4.7-7.5 Volts nominal) 9-36 Volts (24V nominal) 18-75 Volts (48V nominal) Maximum Output Current from each output 0.45 (11.43) METAL CASE Case INSULATED BASE 0.20 (5.08) 0.040 ±0.002 DIA. (1.016 ±0.051) 1.800 (45.72) 0.10 (2.54) 0.200 (5.08) 0.400 (10.16) 0.100 (2.54) BOTTOM VIEW DIMENSIONS INCHES (MM) 1.200 (30.48) 0.400 (10.16) 2.00 (50.80) 0.40 (10.16) Output Power (Watts) BWR-5/1500-D5A BWR-5/1700-D12A BWR-5/1700-D48A BWR-12/625-D5A BWR-12/830-D12A BWR-12/830-D48A BWR-15/500-D5A BWR-15/670-D12A BWR-15/670-D48A Connections Function +Input -Input On/Off Control +Output Cpmmon -Output Trim Notes: "D5A" "D12A" models, case connected (-VIN). "D48A" models, case connected (+VIN). Ambient Temperature (°C) Models Performance/Functional Specifications Typical +25°C under nominal line voltage full-load conditions, unless noted. Input Input Voltage Range: Models D12A Models D48A Models Input Current Input Filter Type Overvoltage Shutdown: Models D12A Models D48A Models Reverse-Polarity Protection On/Off (Sync.) Control (Pin VOUT Accuracy (50% load): Outputs ±9/12/15V Outputs Temperature Coefficient Ripple/Noise (20MHz Line/Load Regulation Efficiency Isolation Voltage Isolation Capacitance Current Limiting Overvoltage Protection Transient Response (50% load step) Switching Frequency Operating Temperature (ambient): Without Derating With Derating Storage Temperature Dimensions Shielding Case Connection: D12A Models D48A Models Case Material 4.7-7.5 Volts nominal) 9-36 Volts (24V nominal) 18-75 Volts (48V nominal) Ordering Guide Volts Volts Volts (Instantaneous, maximum) high off, open) Input Voltage: Models D12A Models D48A Models Absolute Maximum Ratings Volts Volts Volts Current must <10A. Brief duration only. Fusing recommended. Volts, limited duration Volts, limited duration Volts, limited duration Current limited. Max. current short-circuit duration model dependent. +105°C +300°C Input Reverse-Polarity Protection Output Overvoltage Protection Outputs ±12V Outputs ±15V Outputs Output Current Output ±1.5%, maximum ±1%, maximum ±0.02% Ordering Guide Ordering Guide Ordering Guide 1500Vdc, minimum 550pF Auto-recovery Zener/transorb clamps, magnetic feedback Storage Temperature Lead Temperature (soldering, sec.) These stress ratings. Exposure devices these conditions adversely affect long-term reliability. Proper operation under conditions other than those listed Performance/Functional Specifications Table implied. TECHNICAL NOTES Floating Outputs Since these isolated DC/DC converters, their outputs "floating." model configured produce output 10V, (for ±5V, ±12V ±15V models, respectively) applying load across +Output -Output pins (pins with either output grounded. Common (pin should left open. Minimum loading recommended under these conditions. total output voltage span externally trimmed described below. Filtering Noise Reduction A-Series 15-20 Watt DC/DC Converters achieve their rated ripple noise specifications without external input/output capacitors. critical applications, input/output ripple noise further reduced installing electrolytic capacitors across input terminals and/or low-ESR tantalum electrolytic capacitors across output terminals. Output capacitors should connected between their respective output (pin Common (pin shown Figure caps should located close power converters possible. Typical values listed tables below. many applications, using values greater than those listed will yield better results. Reduce Input Ripple Models D12A Models D48A Models Reduce Output Ripple Outputs ±9/12/15V Outputs 47µF, 20µF, 20µF, 100V 47µF, 10V, 22µF, 20V, Dynamic Characteristics 200µsec max. ±1.5% final value 165kHz (±15kHz) Environmental +50/55/60°C (Model dependent) +100°C (See Derating Curves) +105°C Physical 0.45" 11.4mm) 5-sided (-VIN) (+VIN) Corrosion resistant steel with non-conductive, epoxy-based, black enamel finish plastic baseplate Brass, solder coated ounces (75.6 grams) Material Weight These converters require minimum loading each output maintain specified regulation. Operation under no-load conditions will damage these devices; however they meet listed specifications. Application-specific internal input/output filtering recommended perhaps added internally upon request. Contact DATEL Applications Engineering details. Applying voltage Control when input power applied converter cause permanent damage converter. "D48A" models have BASIC, "D5A" "D12A" models have Functional insulation. Devices screened modified higher guaranteed isolation voltages. Contact DATEL Applications Engineering details. critical, space-sensitive applications, DATEL able tailor internal input/output filtering these units meet your specific requirements. Contact Applications Engineering Group additional details. Series +OUTPUT +INPUT -INPUT COMMON +OUTPUT COUT TRIM COUT LOAD +INPUT COMMON -INPUT -OUTPUT 5-10 Turns LOAD -OUTPUT Figure Using External Capacitors Reduce Input/Output Ripple/Noise Figure Trim Connections Using Trimpot Input Fusing Certain applications and/or safety agencies require installation fuses inputs power conversion components. DATEL A-Series 15-20 Watt DC/DC Converters, should slow-blow type fuses with values greater than following: Range D12A D48A On/Off Control On/Off Control (pin used remote on/off operation. logic high Volts, 250µA max.) applied disables converter. logic +0.8 Volts, 70µA max.), connection, enables converter. Control voltages should referenced (-Input). Applying voltage Control when input power applied converter cause permanent damage converter. Synchronization critical applications employing multiple switching DC/DC converters, desirable intentionally synchronize switching selected converters system noise reduced with notch filtering) purposely desynchronize converters lessen current-carrying requirements intermediate buses). multiple A-Series Converters, external clock applied (Control) each device. should square wave with maximum 1µsec "high" duration amplitude between (see On/Off Control) referenced (-Input). frequency synchronizing clock should higher than that individual converter. Therefore, should 185kHz ±5kHz. Output Trimming total output voltage span, from +Output (pin -Output (pin trimmed single external trimpot fixed resistor. trimpot should connected shown Figure with wiper connected (Trim). trimpot used determine value single fixed resistor which should connected shown Figures Connect resistor between (Trim) (+Output) trim "down" output voltages. Connect resistor between pins (-Output) trim "up" output voltages. Fixed resistors should metal-film types with absolute TCR's less than 100ppm/°C ensure stability. +INPUT +OUTPUT +INPUT TRIM -INPUT COMMON LOAD LOAD -OUTPUT Fuse Value Figure Fixed-Value Trim Down Resistor +OUTPUT COMMON TRIM -INPUT LOAD LOAD -OUTPUT Figure Fixed-Value Trim Resistor Models DATEL's world-class design, development manufacturing team stands ready work with deliver exact power converter need your demanding, large volume, applications. we'll time within budget! experienced applications design staffs; quick-turn prototype capability; highly automated, assembly facilities; in-line qualitycontrol techniques combine give unique ability design deliver quantity power converters highest standards quality reliability. have compiled large library DC/DC designs that currently used variety telecom, medical, computer, railway, aerospace industrial applications. already have converter need. Contact goal provide highest-quality, most cost-effective you're designing with mind, please note that DATEL's 15-20 Watt A-Series DC/DC Converters have been characterized radiated conducted emissions EMI/EMC laboratory. Testing conducted EMCO 5305 GTEM test cell utilizing EMCO automated test software. Radiated emissions tested limits Part Class CISPR 55022), Class Correlation other specifications supplied upon request. Radiated emissions plots CISPR model BWR-5/1700-D48A appear below. Published test reports available each model number. Contact DATEL's Applications Engineering Department more details. BWR-5/1700-D48A Radiated Emissions Part Class Meters Converter Output ±5Vdc ±1.6A Radiated Emissions (dBµV/M) Class Limit Radiated Emissions 1000 Frequency (MHz) BWR-5/1700-D48A Radiated Emissions 55022 Class Meters Converter Output ±5Vdc ±1.6A Radiated Emissions (dBµV/M) 55022 Class Limit Radiated Emissions 1000 Frequency (MHz) Series Quality Reliability A-Series first DC/DC Converters emerge from DATEL's new, company-wide approach designing manufacturing most reliable power converters available. five-pronged program draws Quality Assurance function into aspects new-product design, development, characterization, qualification manufacturing. Design Reliability Design Reliability woven throughout multi-phased, new-productdevelopment process. Design-for-reliability practices fully documented begin early new-product development cycle with following goals: work from approved components/vendors list ensuring reliable components rigorous qualification components. design with safety margins adhering strict derating guidelines performing theoretical worst-case analyses. locate potential design weaknesses early product-development cycle using extensive HALT (Highly Accelerated Life Testing). prove that early design improvements effective employing thorough FRACA (Failure Reporting Analysis Corrective Action) system. HALT Testing goal accelerated-stress techniques used DATEL force device maturity, short period time, exposing devices excessive levels "every stimulus potential value." HALT (Highly Accelerated Life Testing) repeatedly during design early manufacturing phases detect potential electrical mechanical design weaknesses that could result possible future field failures. During HALT, prototype pre-production DC/DC converters subjected progressively higher stress levels induced thermal cycling, rate temperature change, vibration, power cycling, product-specific stresses (such voltage variation) combined environments. stresses meant simulate field environments expose weaknesses product's electro/mechanical design and/or assembly processes. goal HALT make products fail that device weaknesses analyzed strengthened appropriate. Applied stresses continually stepped Typical HALT Profile Temperature (°C) Random Vibration (G's) until products eventually fail. After corrective actions and/or design changes, stresses stepped again cycle repeated until "fundamental limit technology" determined. DATEL invested Qualmark OVS-1 HALT tester capable applying voltage temperature extremes well 6-axis, linear rotational, random vibration. typical HALT profile (shown above) consists thermal cycling (-55 +125°C, 30°C/minute) simultaneous, gradually increasing, random longitudinal rotational vibration 20G's with load cycling applied-voltage extremes added desired. Many devices DATEL's A-Series could made fail prior reaching either limits HALT chamber some previously known physical limit device. also HALT chamber ability rapidly cool devices verify their "cold-start" capabilities. Qualification each product, electrical performance verified comprehensive characterization process long-term reliability confirmed rigorous qualification procedure. qual procedure includes such strenuous tests thermal shock hour life. Qual testing summarized below. Qualification Testing Qualification Test HALT High Temperature Storage Thermal Shock Temperature/Humidity Lead Integrity Life Test Marking Permanency Point Electrical Tests Interim electrical test hours. Method/Comments DATEL in-house procedure Max. rated temp., 1,000 hours cycles, +125°C +85°C, humidity, hours DATEL in-house procedure +70°C, hours* DATEL in-house procedure product specification In-Line Process Controls Screening combination statistical sampling 100% inspection techniques keeps assembly line under constant control. Parameters such solder-paste thickness, component placement, cleanliness, etc. statistically sampled, charted fine tuned necessary. Visual inspections performed trained operators after pick-and-place, soldering cleaning operations. Units 100% electrically tested prior potting. devices temperature cycled, burned-in, hi-pot tested final-electrical tested prior external visual examination, packing shipping. Rapid Response Problems DATEL employs outstanding corrective-action system immediately address detected shortcomings either products processes. Whenever assembly, quality engineering personnel spot product/process problem, product returned with potential defect, immediately perform detailed failure analysis and, necessary, undertake corrective actions. Over time, this system helped refine assembly operation yield lowest product defect rates industry. Test Time (minutes) INNOVATION EXCELLENCE 9001 REGISTERED DS-0323A 8/02 DATEL, Inc. Cabot Boulevard, Mansfield, 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Bretonneux, France Tel: 01-34-60-01-01 DATEL GmbH Germany Tel: 89-544334-0 DATEL Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025 DATEL makes representation that products circuits described herein, other technical information contained herein, will infringe upon existing future patent rights. descriptions contained herein imply granting licenses make, use, sell equipment constructed accordance therewith. Specifications subject change without notice. DATEL logo registered DATEL, Inc. trademark. Other recent searchesTDA7476 - TDA7476 TDA7476 Datasheet TA48S018 - TA48S018 TA48S018 Datasheet TA48S018F - TA48S018F TA48S018F Datasheet TA48S02F - TA48S02F TA48S02F Datasheet TA48S025F - TA48S025F TA48S025F Datasheet TA48S03F - TA48S03F TA48S03F Datasheet TA48S033F - TA48S033F TA48S033F Datasheet TA48S05F - TA48S05F TA48S05F Datasheet LOG102 - LOG102 LOG102 Datasheet LND150 - LND150 LND150 Datasheet LND250 - LND250 LND250 Datasheet LFCN-3000 - LFCN-3000 LFCN-3000 Datasheet IDT723626 - IDT723626 IDT723626 Datasheet IDT723636 - IDT723636 IDT723636 Datasheet IDT723646 - IDT723646 IDT723646 Datasheet FCH20A06 - FCH20A06 FCH20A06 Datasheet AZ100E111 - AZ100E111 AZ100E111 Datasheet
Privacy Policy | Disclaimer |