The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

X10461 INTRODUCTION module high power, full wave Phase Angle Cont


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



POWER CONTROLLER
X10461
INTRODUCTION module high power, full wave Phase Angle Controller compact package, capable regulating (25A) 230V PAC2 regulator governs amount power supplied load, controlling phase angle supply. thermal impedance high electrical isolation provides equipment designer with greater flexibility wide variety applications. APPLICATIONS Suitable most power control applications such infra-red, quartz ceramic heaters, lighting. also used inductive loads such transformers motors.
FEATURES
Solid state reliability. S.M.T Simple wiring. Rugged compact High current capability. Internal snubber.
INSTALLATION
INSTALLATION
SPECIFICATIONS
line voltage Unit limiting current Peak cycle surge (10ms) Minimum operating current Isolation voltage Power terminals Storage temperature 230V 50/60 250A 0.05A 3500Vrms 10mm -20°C +85°C line supply fusing peak voltage Leakage current Control Signal Power consumption Max. operating temperature 50mA 600Vac 0-5v watts 65°C
FUSING
recommended semiconductor (fast acting) type fuses circuit breakers (Semiconductor MCB) unit protection appropriate safety fuse unit supply (F1A). initial `switch some loads need increased factor safety unit and/or device protection. (See Datasheet further information).
MARKING
This product family carries marking". These phase angle controllers need suitable remote filter. information recommendation section contact sales desk. (See Declaration Conformity).
RECOMMENDATIONS
Other documents available request, which appropriate your application:CODE IDENTITY DESCRIPTION X10229 Filtering recommendations addressing Directive X10213 Interaction, uses phase angle burst fire control. X10255 Safety requirements addressing Voltage Directive (LVD) including:- Thermal data/cooling "Live" parts warning Earth requirements; Fusing recommendations. AP02/4 Conditions sale. NOTE recommended that installation maintenance this equipment should done with reference current edition I.E.E. wiring regulations (BS7671) suitably qualified/trained personnel. regulations contain important requirements regarding safety electrical equipment (For International Standards refer I.E.C. directive 950).
ORDER CODE
State part number:
Optional extras include: Potentiometer, Filter, Heatsink paste, Heatsink assembly
UNITED AUTOMATION LIMITED
1Southport Business Park Southport, ENGLAND Page Issue Tel: 0044 1704 516500 Main Tel: 0044 1704 516516 Sales Fax: 0044 1704 516501 Enquiry@united-automation.com Date 10/11/01

Other recent searches


SW105S05HISMF - SW105S05HISMF   SW105S05HISMF Datasheet
SW105S12HISMF - SW105S12HISMF   SW105S12HISMF Datasheet
SW105S15HISMF - SW105S15HISMF   SW105S15HISMF Datasheet
SW105D05HISMF - SW105D05HISMF   SW105D05HISMF Datasheet
SW105D12HISMF - SW105D12HISMF   SW105D12HISMF Datasheet
SW105D15HISMF - SW105D15HISMF   SW105D15HISMF Datasheet
SW112S05HISMF - SW112S05HISMF   SW112S05HISMF Datasheet
SW112S12HISMF - SW112S12HISMF   SW112S12HISMF Datasheet
SW112S15HISMF - SW112S15HISMF   SW112S15HISMF Datasheet
SW112D05HISMF - SW112D05HISMF   SW112D05HISMF Datasheet
SW112D12HISMF - SW112D12HISMF   SW112D12HISMF Datasheet
SW112D15HISMF - SW112D15HISMF   SW112D15HISMF Datasheet
SW115S05HISMF - SW115S05HISMF   SW115S05HISMF Datasheet
SW115S12HISMF - SW115S12HISMF   SW115S12HISMF Datasheet
SW115S15HISMF - SW115S15HISMF   SW115S15HISMF Datasheet
SW115D05HISMF - SW115D05HISMF   SW115D05HISMF Datasheet
SW115D12HISMF - SW115D12HISMF   SW115D12HISMF Datasheet
SW115D15HISMF - SW115D15HISMF   SW115D15HISMF Datasheet
STS750 - STS750   STS750 Datasheet
SSM2166 - SSM2166   SSM2166 Datasheet
SSM2165 - SSM2165   SSM2165 Datasheet
EC100-104 - EC100-104   EC100-104 Datasheet
EC100-254 - EC100-254   EC100-254 Datasheet
EC100-504 - EC100-504   EC100-504 Datasheet
EC200-503 - EC200-503   EC200-503 Datasheet
EC200-104 - EC200-104   EC200-104 Datasheet
EC200-254 - EC200-254   EC200-254 Datasheet
EC200-504 - EC200-504   EC200-504 Datasheet
EC300-253 - EC300-253   EC300-253 Datasheet
EC300-503 - EC300-503   EC300-503 Datasheet
EC300-104 - EC300-104   EC300-104 Datasheet
EC300-254 - EC300-254   EC300-254 Datasheet
EC400-253 - EC400-253   EC400-253 Datasheet
EC400-503 - EC400-503   EC400-503 Datasheet
EC400-104 - EC400-104   EC400-104 Datasheet
EC400-124 - EC400-124   EC400-124 Datasheet
EC500-103 - EC500-103   EC500-103 Datasheet
EC500-253 - EC500-253   EC500-253 Datasheet
EC500-503 - EC500-503   EC500-503 Datasheet
EC500-104 - EC500-104   EC500-104 Datasheet
EC600-502 - EC600-502   EC600-502 Datasheet
EC600-103 - EC600-103   EC600-103 Datasheet
EC600-253 - EC600-253   EC600-253 Datasheet
EC600-503 - EC600-503   EC600-503 Datasheet
EC600-104 - EC600-104   EC600-104 Datasheet
EC800-502 - EC800-502   EC800-502 Datasheet
BZT52-T - BZT52-T   BZT52-T Datasheet
BBY59 - BBY59   BBY59 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive