The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Safety Limit Switches compatible Popular D4D, Providing Full Lineup Co


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Miniature Safety Limit Switch
Safety Limit Switches compatible Popular D4D, Providing Full Lineup Conforming International Standards
Lineup includes three contact models with 2NC/1NO addition 1NC/1NO, contact models. Models with contacts available too. M12-connector models available, saving labor simplifying maintenance. Standardized gold-clad contacts provide high contact reliability. used with both standard loads microloads. Free lead, cadmium, hexavalent chrome, reducing burden environment. Conforms EN115 EN81-1. Lineup includes both slow-action snap-action models with contacts.
!Caution
sure read Safety Precautions page
Note: Contact your sales representative details models with safety standard certification.
Model Number Structure
Model Number Legend
D4N-@@@@
Head Actuator Roller lever (resin lever, resin roller) Roller lever (metal lever, resin roller) Roller lever (metal lever, metal roller) Roller lever (metal lever, bearing roller) Adjustable roller lever, form lock (metal lever, resin roller) Adjustable roller lever, form lock (metal lever, rubber roller) plunger roller plunger One-way roller lever (horizontal) One-way roller lever (vertical) whisker Plastic Fork lever lock (right operation) Fork lever lock (left operation) Conduit/Connector size Pg13.5 (1-conduit) G1/2 (1-conduit) 1/2-14NPT (1-conduit) (1-conduit) Pg13.5 (2-conduit) G1/2 (2-conduit) 1/2-14NPT (2-conduit) (2-conduit) connector (1-conduit) Built-in Switch 1NC/1NO (snap-action) (snap-action) 1NC/1NO (slow-action) (slow-action) 2NC/1NO (slow-action) (slow-action) 1NC/1NO (MBB contact-/-slow-action) 2NC/1NO (MBB contact-/-slow-action)
Miniature Safety Limit Switch
Ordering Information
List Models
Switches with Contacts
Actuator Conduit size 1NC/1NO (Snapaction) Direct opening Roller lever (resin 1-conduit lever, resin roller) Pg13.5 G1/2 1/2-14NPT connector 2-conduit Pg13.5 G1/2 Roller lever (metal 1-conduit lever, resin roller) Pg13.5 G1/2 1/2-14NPT connector 2-conduit Pg13.5 G1/2 Roller lever (metal 1-conduit lever, metal roller) Pg13.5 G1/2 1/2-14NPT connector Roller lever (metal 1-conduit lever, bearing roller) Pg13.5 G1/2 1/2-14NPT connector Plunger 1-conduit Pg13.5 G1/2 1/2-14NPT connector 2-conduit Pg13.5 G1/2 Roller plunger 1-conduit Pg13.5 G1/2 1/2-14NPT connector 2-conduit Pg13.5 G1/2 Prefered types Model D4N-1120 D4N-2120 D4N-3120 D4N-4120 D4N-9120 D4N-5120 D4N-6120 D4N-8120 D4N-1122 D4N-2122 D4N-3122 D4N-4122 D4N-9122 D4N-5122 D4N-6122 D4N-8122 D4N-1125 D4N-2125 D4N-3125 D4N-4125 D4N-9125 D4N-1126 D4N-2126 D4N-3126 D4N-4126 D4N-9126 D4N-1131 D4N-2131 D4N-3131 D4N-4131 D4N-9131 D4N-5131 D4N-6131 D4N-8131 D4N-1132 D4N-2132 D4N-3132 D4N-4132 D4N-9132 D4N-5132 D4N-6132 D4N-8132 Built-in switch mechanism (Snap-action) Direct opening Model D4N-1220 D4N-2220 D4N-3220 D4N-4220 D4N-9220 D4N-5220 D4N-6220 D4N-8220 D4N-1222 D4N-2222 D4N-3222 D4N-4222 D4N-9222 D4N-5222 D4N-6222 D4N-8222 D4N-1225 D4N-2225 D4N-3225 D4N-4225 D4N-9225 D4N-1226 D4N-2226 D4N-3226 D4N-4226 D4N-9226 D4N-1231 D4N-2231 D4N-3231 D4N-4231 D4N-9231 D4N-5231 D4N-6231 D4N-8231 D4N-1232 D4N-2232 D4N-3232 D4N-4232 D4N-9232 D4N-5232 D4N-6232 D4N-8232 1NC/1NO (Slowaction) Direct opening Model D4N-1A20 D4N-2A20 D4N-3A20 D4N-4A20 D4N-9A20 D4N-5A20 D4N-6A20 D4N-8A20 D4N-1A22 D4N-2A22 D4N-3A22 D4N-4A22 D4N-9A22 D4N-5A22 D4N-6A22 D4N-8A22 D4N-1A25 D4N-2A25 D4N-3A25 D4N-4A25 D4N-9A25 D4N-1A26 D4N-2A26 D4N-3A26 D4N-4A26 D4N-9A26 D4N-1A31 D4N-2A31 D4N-3A31 D4N-4A31 D4N-9A31 D4N-5A31 D4N-6A31 D4N-8A31 D4N-1A32 D4N-2A32 D4N-3A32 D4N-4A32 D4N-9A32 D4N-5A32 D4N-6A32 D4N-8A32 (Slow-action) Direct opening Model D4N-1B20 D4N-2B20 D4N-3B20 D4N-4B20 D4N-9B20 D4N-5B20 D4N-6B20 D4N-8B20 D4N-1B22 D4N-2B22 D4N-3B22 D4N-4B22 D4N-9B22 D4N-5B22 D4N-6B22 D4N-8B22 D4N-1B25 D4N-2B25 D4N-3B25 D4N-4B25 D4N-9B25 D4N-1B26 D4N-2B26 D4N-3B26 D4N-4B26 D4N-9B26 D4N-1B31 D4N-2B31 D4N-3B31 D4N-4B31 D4N-9B31 D4N-5B31 D4N-6B31 D4N-8B31 D4N-1B32 D4N-2B32 D4N-3B32 D4N-4B32 D4N-9B32 D4N-5B32 D4N-6B32 D4N-8B32
Miniature Safety Limit Switch
Actuator
Conduit size 1NC/1NO (Snapaction) Direct opening Model D4N-1162 D4N-2162 D4N-3162 D4N-4162 D4N-9162 D4N-5162 D4N-6162 D4N-8162 D4N-1172 D4N-2172 D4N-3172 D4N-4172 D4N-9172 D4N-5172 D4N-6172 D4N-8172 D4N-112G D4N-212G D4N-312G D4N-412G D4N-912G D4N-612G D4N-812G D4N-112H D4N-212H D4N-312H D4N-412H D4N-912H D4N-612H D4N-812H
Built-in switch mechanism (Snap-action) Direct opening Model D4N-1262 D4N-2262 D4N-3262 D4N-4262 D4N-9262 D4N-5262 D4N-6262 D4N-8262 D4N-1272 D4N-2272 D4N-3272 D4N-4272 D4N-9272 D4N-5272 D4N-6272 D4N-8272 D4N-122G D4N-222G D4N-322G D4N-422G D4N-922G D4N-622G D4N-822G D4N-122H D4N-222H D4N-322H D4N-422H D4N-922H D4N-622H D4N-822H 1NC/1NO (Slowaction) Direct opening Model D4N-1A62 D4N-2A62 D4N-3A62 D4N-4A62 D4N-9A62 D4N-5A62 D4N-6A62 D4N-8A62 D4N-1A72 D4N-2A72 D4N-3A72 D4N-4A72 D4N-9A72 D4N-5A72 D4N-6A72 D4N-8A72 D4N-1A2G D4N-2A2G D4N-3A2G D4N-4A2G D4N-9A2G D4N-6A2G D4N-8A2G D4N-1A2H D4N-2A2H D4N-3A2H D4N-4A2H D4N-9A2H D4N-6A2H D4N-8A2H (Slow-action) Direct opening Model D4N-1B62 D4N-2B62 D4N-3B62 D4N-4B62 D4N-9B62 D4N-5B62 D4N-6B62 D4N-8B62 D4N-1B72 D4N-2B72 D4N-3B72 D4N-4B72 D4N-9B72 D4N-5B72 D4N-6B72 D4N-8B72 D4N-1B2G D4N-2B2G D4N-3B2G D4N-4B2G D4N-9B2G D4N-6B2G D4N-8B2G D4N-1B2H D4N-2B2H D4N-3B2H D4N-4B2H D4N-9B2H D4N-6B2H D4N-8B2H
One-way roller lever (horizontal)
1-conduit
Pg13.5 G1/2 1/2-14NPT connector
2-conduit
Pg13.5 G1/2
One-way roller lever (vertical)
1-conduit
Pg13.5 G1/2 1/2-14NPT connector
2-conduit
Pg13.5 G1/2
Adjustable roller 1-conduit lever, form lock (metal lever, resin roller)
Pg13.5 G1/2 1/2-14NPT connector
2-conduit Adjustable roller 1-conduit lever, form lock (metal lever, rubber roller)
G1/2 Pg13.5 G1/2 1/2-14NPT connector
2-conduit
G1/2
Note: recommended that used Switches exported Europe 1/2-14NPT used Switches exported North American countries. Prefered types
Switches with Three Contacts Contacts
Actuator Conduit size 2NC/1NO (Snapaction) Direct opening Roller lever (resin 1-conduit lever, resin roller) Pg13.5 G1/2 1/2-14NPT connector 2-conduit Pg13.5 G1/2 Prefered types Model D4N-1C20 D4N-2C20 D4N-3C20 D4N-4C20 -D4N-5C20 D4N-6C20 D4N-8C20 Built-in switch mechanism (Snap-action) Direct opening Model D4N-1D20 D4N-2D20 D4N-3D20 D4N-4D20 -D4N-5D20 D4N-6D20 D4N-8D20 1NC/1NO (Slow-action) Direct opening Model D4N-1E20 D4N-2E20 D4N-3E20 D4N-4E20 D4N-9E20 D4N-5E20 D4N-6E20 D4N-8E20 2NC/1NO (Slow-action) Direct opening Model D4N-1F20 D4N-2F20 D4N-3F20 D4N-4F20 -D4N-5F20 D4N-6F20 D4N-8F20
Miniature Safety Limit Switch
Actuator
Conduit size 2NC/1NO (Snapaction) Direct opening Model D4N-1C22 D4N-2C22 D4N-3C22 D4N-4C22 -D4N-5C22 D4N-6C22 D4N-8C22 D4N-1C25 D4N-2C25 D4N-3C25 D4N-4C25 -D4N-1C26 D4N-2C26 D4N-3C26 D4N-4C26 -D4N-1C31 D4N-2C31 D4N-3C31 D4N-4C31 -D4N-5C31 D4N-6C31 D4N-8C31 D4N-1C32 D4N-2C32 D4N-3C32 D4N-4C32 -D4N-5C32 D4N-6C32 D4N-8C32 D4N-1C62 D4N-2C62 D4N-3C62 D4N-4C62 -D4N-5C62 D4N-6C62 D4N-8C62 D4N-1C72 D4N-2C72 D4N-3C72 D4N-4C72 -D4N-5C72 D4N-6C72 D4N-8C72
Built-in switch mechanism (Snap-action) Direct opening Model D4N-1D22 D4N-2D22 D4N-3D22 D4N-4D22 -D4N-5D22 D4N-6D22 D4N-8D22 D4N-1D25 D4N-2D25 D4N-3D25 D4N-4D25 -D4N-1D26 D4N-2D26 D4N-3D26 D4N-4D26 -D4N-1D31 D4N-2D31 D4N-3D31 D4N-4D31 -D4N-5D31 D4N-6D31 D4N-8D31 D4N-1D32 D4N-2D32 D4N-3D32 D4N-4D32 -D4N-5D32 D4N-6D32 D4N-8D32 D4N-1D62 D4N-2D62 D4N-3D62 D4N-4D62 -D4N-5D62 D4N-6D62 D4N-8D62 D4N-1D72 D4N-2D72 D4N-3D72 D4N-4D72 -D4N-5D72 D4N-6D72 D4N-8D72 1NC/1NO (Slow-action) Direct opening Model D4N-1E22 D4N-2E22 D4N-3E22 D4N-4E22 D4N-9E22 D4N-5E22 D4N-6E22 D4N-8E22 D4N-1E25 D4N-2E25 D4N-3E25 D4N-4E25 D4N-9E25 D4N-1E26 D4N-2E26 D4N-3E26 D4N-4E26 D4N-9E26 D4N-1E31 D4N-2E31 D4N-3E31 D4N-4E31 D4N-9E31 D4N-5E31 D4N-6E31 D4N-8E31 D4N-1E32 D4N-2E32 D4N-3E32 D4N-4E32 D4N-9E32 D4N-5E32 D4N-6E32 D4N-8E32 D4N-1E62 D4N-2E62 D4N-3E62 D4N-4E62 D4N-9E62 D4N-5E62 D4N-6E62 D4N-8E62 D4N-1E72 D4N-2E72 D4N-3E72 D4N-4E72 D4N-9E72 D4N-5E72 D4N-6E72 D4N-8E72 2NC/1NO (Slow-action) Direct opening Model D4N-1F22 D4N-2F22 D4N-3F22 D4N-4F22 -D4N-5F22 D4N-6F22 D4N-8F22 D4N-1F25 D4N-2F25 D4N-3F25 D4N-4F25 -D4N-1F26 D4N-2F26 D4N-3F26 D4N-4F26 -D4N-1F31 D4N-2F31 D4N-3F31 D4N-4F31 -D4N-5F31 D4N-6F31 D4N-8F31 D4N-1F32 D4N-2F32 D4N-3F32 D4N-4F32 -D4N-5F32 D4N-6F32 D4N-8F32 D4N-1F62 D4N-2F62 D4N-3F62 D4N-4F62 -D4N-5F62 D4N-6F62 D4N-8F62 D4N-1F72 D4N-2F72 D4N-3F72 D4N-4F72 -D4N-5F72 D4N-6F72 D4N-8F72
Roller lever (metal 1-conduit lever, resin roller)
Pg13.5 G1/2 1/2-14NPT connector
2-conduit
Pg13.5 G1/2
Roller lever (metal 1-conduit lever, metal roller)
Pg13.5 G1/2 1/2-14NPT connector
Roller lever (metal 1-conduit lever, bearing roller)
Pg13.5 G1/2 1/2-14NPT connector
Plunger
1-conduit
Pg13.5 G1/2 1/2-14NPT connector
2-conduit
Pg13.5 G1/2
Roller plunger
1-conduit
Pg13.5 G1/2 1/2-14NPT connector
2-conduit
Pg13.5 G1/2
One-way roller lever (horizontal)
1-conduit
Pg13.5 G1/2 1/2-14NPT connector
2-conduit
Pg13.5 G1/2
One-way roller lever (vertical)
1-conduit
Pg13.5 G1/2 1/2-14NPT connector
2-conduit
Pg13.5 G1/2
Prefered types
Miniature Safety Limit Switch
Actuator
Conduit size 2NC/1NO (Snapaction) Direct opening Model D4N-1C2G D4N-2C2G D4N-3C2G D4N-4C2G -D4N-6C2G D4N-8C2G D4N-1C2H D4N-2C2H D4N-3C2H D4N-4C2H -D4N-6C2H D4N-8C2H
Built-in switch mechanism (Snap-action) Direct opening Model D4N-1D2G D4N-2D2G D4N-3D2G D4N-4D2G -D4N-6D2G D4N-8D2G D4N-1D2H D4N-2D2H D4N-3D2H D4N-4D2H -D4N-6D2H D4N-8D2H 1NC/1NO (Slow-action) Direct opening Model D4N-1E2G D4N-2E2G D4N-3E2G D4N-4E2G D4N-9E2G D4N-6E2G D4N-8E2G D4N-1E2H D4N-2E2H D4N-3E2H D4N-4E2H D4N-9E2H D4N-6E2H D4N-8E2H 2NC/1NO (Slow-action) Direct opening Model D4N-1F2G D4N-2F2G D4N-3F2G D4N-4F2G -D4N-6F2G D4N-8F2G D4N-1F2H D4N-2F2H D4N-3F2H D4N-4F2H -D4N-6F2H D4N-8F2H
Adjustable roller 1-conduit lever, form lock (metal lever, resin roller)
Pg13.5 G1/2 1/2-14NPT connector
2-conduit Adjustable roller 1-conduit lever, form lock (metal lever, rubber roller)
G1/2 Pg13.5 G1/2 1/2-14NPT connector
2-conduit
G1/2
Note: recommended that used Switches exported Europe 1/2-14NPT used Switches exported North American countries.
General-purpose Switches with Contacts
Actuator Conduit size 1NC/1NO (Snapaction) Direct opening Fork lever lock (right operation) 1-conduit G1/2 1/2-14NPT 2-conduit Fork lever lock (left operation) 1-conduit G1/2 G1/2 1/2-14NPT 2-conduit whisker 1-conduit G1/2 G1/2 1/2-14NPT 2-conduit Plastic 1-conduit G1/2 G1/2 1/2-14NPT 2-conduit Prefered types Note: recommended that used Switches exported Europe 1/2-14NPT used Switches exported North American countries. Mechanically speaking, these models basic limit switches. G1/2 -D4N-2180 D4N-3180 D4N-4180 D4N-6180 D4N-8180 D4N-2187 D4N-3187 D4N-4187 D4N-6187 D4N-8187 -D4N-2280 D4N-3280 D4N-4280 D4N-6280 D4N-8280 D4N-2287 D4N-3287 D4N-4287 D4N-6287 D4N-8287 -Model Built-in switch mechanism (Snap-action) Direct opening -Model 1NC/1NO (Slowaction) Direct opening -Model (Slow-action) Direct opening Model D4N-2BRE D4N-3BRE D4N-4BRE D4N-6BRE D4N-8BRE D4N-2BLE D4N-3BLE D4N-4BLE D4N-6BLE D4N-8BLE -D4N-2B80 D4N-3B80 D4N-4B80 D4N-6B80 D4N-8B80 D4N-2B87 D4N-3B87 D4N-4B87 D4N-6B87 D4N-8B87
D4N-2ARE -D4N-3ARE D4N-4ARE D4N-6ARE -D4N-8ARE D4N-2ALE -D4N-3ALE D4N-4ALE D4N-6ALE -D4N-8ALE
!WARNING
general purpose switch models applications that require form lock safety reasons
Miniature Safety Limit Switch
General-purpose Switches with Three Contacts Contacts
Actuator Conduit size Built-in switch mechanism Direct 2NC/1NO Direct Direct opening (Slow-action) opening (Slow-action) opening Fork lever lock 1-conduit (right operation) 2-conduit Fork lever lock (left operation) 1-conduit G1/2 1/2-14NPT G1/2 G1/2 1/2-14NPT 2-conduit whisker 1-conduit G1/2 G1/2 1/2-14NPT 2-conduit Plastic 1-conduit G1/2 G1/2 1/2-14NPT 2-conduit G1/2 -D4N-2CRE D4N-3CRE D4N-4CRE D4N-6CRE D4N-8CRE D4N-2CLE D4N-3CLE D4N-4CLE D4N-6CLE D4N-8CLE -D4N-2DRE D4N-3DRE D4N-4DRE D4N-6DRE D4N-8DRE D4N-2DLE D4N-3DLE D4N-4DLE D4N-6DLE D4N-8DLE D4N-2D80 D4N-3D80 D4N-4D80 D4N-6D80 D4N-8D80 D4N-2D87 D4N-3D87 D4N-4D87 D4N-6D87 D4N-8D87 -1NC/1NO Direct 2NC/1NO opening (Slow-action) (Slow-action) D4N-2ERE D4N-3ERE D4N-4ERE D4N-6ERE D4N-8ERE D4N-2ELE D4N-3ELE D4N-4ELE D4N-6ELE D4N-8ELE -D4N-2FRE D4N-3FRE D4N-4FRE D4N-6FRE D4N-8FRE D4N-2FLE D4N-3FLE D4N-4FLE D4N-6FLE D4N-8FLE
Note: recommended that used Switches exported Europe 1/2-14NPT used Switches exported North American countries. !WARNING Mechanically speaking, these models basic limit switches. general purpose switch models applications that require form lock safety reasons
Specifications
Standards Directives
Conforms following Directives: Machinery Directive Voltage Directive EN50047 EN1088 (slow-action models only) GS-ET-15
Approved Standard Ratings
(EN60947-5-1)
Item Utilization category AC-15 DC-13 0.27 Rated operating current (Ie)
Approved Standards
Agency Product Service (See note.) Standard EN60947-5-1 (approved direct opening) UL508, C22.2 No.14 File 39656 E76675
Rated operating voltage (Ue)
Note: 10-A fuse type that conforms IEC269 short-circuit protection device. This fuse built into Switch.
UL/CSA (UL508, C22.2
A300
Rated voltage Carry current Current Make Break Volt-amperes Make Break 7,200
Note: Approval C22.2 authorized mark.
(China Compulsory Certification) Mark
Agency Standard GB14048.5 File Under application
Q300
Rated voltage Carry current Current Make 0.55 0.27 Break 0.55 0.27 Volt-amperes Make Break
Miniature Safety Limit Switch
Characteristics
Degree protection (See note Durability (See note Operating speed Operating frequency Contact resistance Minimum applicable load (See note Rated insulation voltage (Ui) Protection against electric shock Pollution degree (operating environment) Impulse withstand voltage (EN60947-5-1) Mechanical Electrical IP67 (EN60947-5-1) 15,000,000 operations min. (See note 500,000 operations min. resistive load (See note 300,000 operations min. resistive load mm/s (D4N-1120) operations/minute max. max. Resistive load (N-level reference value) Class (double insulation) Level (EN60947-5-1) Between terminals same polarity: Between terminals different polarities: Between other terminals uncharged metallic parts Insulation resistance Contact Vibration resistance Shock resistance Malfunction Destruction Malfunction Conditional short-circuit current Rated open thermal current (Ith) Ambient temperature Ambient humidity Weight min. Snap-action: Slow-action: 0.75-mm single amplitude 1,000 m/s2 min. m/s2 min. (EN60947-5-1) (EN60947-5-1) Operating: with icing Operating: max. Approx. (D4N-1120) Approx. (D4N-5120)
Note: above values initial values. Once contact been used switch standard load, cannot used load smaller capacity. Doing result roughening contact surface contact reliability lost. degree protection tested using method specified standard (EN60947-5-1). Confirm that sealing properties sufficient operating conditions environment beforehand. Although switch protected from dust water penetration, places where foreign material such dust, dirt, oil, water, chemicals penetrate through head. Otherwise, premature wear, Switch damage malfunctioning occur. durability ambient temperature ambient humidity 70%. more details, consult your OMRON representative. ambient temperature greater than pass 3-A, 250-VAC load through more than circuits. This value will vary with switching frequency, environment, reliability level. Confirm that correct operation possible with actual load beforehand. mechanical durability fork lever lock models 10,000,000 operations min.
Miniature Safety Limit Switch
Structure, Names, Functions
Structure
Safety-oriented Lever Setting (Form-lock construction) Grooves which engage lever lever rotary shaft prevent lever from slipping against rotary shaft. There resin-lever metal-lever types.
Head direction switch head varied four directions. (Roller plunger models mounted either directions angle.)
Conduit Opening
wide variety conduits available.
Built-in Switch built-in switch direct opening mechanism that forcibly separates contact even when there contact deposit.
Cover cover, with hinge lower part, opened removing screw cover, which ensures ease maintenance wiring.
Size Pg13.5 G1/2 1/2-14NPT connector
1-conduit
2-conduit
Note: connector types available Switches with three contacts.
Direct Opening Mechanism
1NC/1NO Contact (Slow-action)
Fixed contact (NC) Contact spring Movable contact Fixed contact (NO) Plunger Return spring
Conforms EN60947-5-1 Direct Opening Operation (Only contact side direct opening mechanism.) When metal deposition occurs, contacts separated from each other plunger being pushed
Contact (Slow-action)
Fixed contact (NC) Movable contact Contact spring Plunger
Conforms EN60947-5-1 Direct Opening Operation (Both contacts have direct opening mechanism.)
Return spring
Miniature Safety Limit Switch
Contact Form
Model D4N-@1@ Contact 1NC/1NO (Snap-action)
Contact form
Operating pattern
Remarks
13-14 31-32 Stroke
Only contacts 31-32 have approved direct opening mechanism. terminals 13-14 31-32 used unlike poles. Only contacts 11-12 31-32 have approved direct opening mechanism. terminals 11-12 31-32 used unlike poles. Only contacts 11-12 have approved direct opening mechanism. terminals 11-12 33-34 used unlike poles. Only contacts 11-12 31-32 have approved direct opening mechanism. terminals 11-12 31-32 used unlike poles. Only contacts 11-12 21-22 have approved direct opening mechanism. terminals 11-12, 21-22, 33-34 used unlike poles. Only contacts 11-12, 21-22, 31-32 have approved direct opening mechanism. terminals 11-12, 21-22, 31-32 used unlike poles. Only contacts 11-12 have approved direct opening mechanism. terminals 11-12 33-34 used unlike poles. Only contacts 11-12 21-22 have approved direct opening mechanism. terminals 11-12, 21-22 33-34 used unlike poles.
D4N-@2@
(Snap-action)
11-12 31-32 Stroke
D4N-@A@
1NC/1NO (Slow-action)
11-12 33-34 Stroke
D4N-@B@
(Slow-action)
11-12 31-32 Stroke
D4N-@C@
2NC/1NO (Slow-action)
11-12 21-22 33-34 Stroke
D4N-@D@
(Slow-action)
11-12 21-22 31-32 Stroke
D4N-@E@
1NC/1NO (Slow-action)
11-12 33-34 Stroke
D4N-@F@
2NC/1NO (Slow-action)
11-12 21-22 33-34 Stroke
Note: Terminals numbered according EN50013 contact forms according IEC947-5-1. (Make Before Break) contacts have overlapping structure, that before normally closed contact (NC) opens, normally open contact (NO) closes.
Miniature Safety Limit Switch
Dimensions
Switches
Note: units millimeters unless otherwise indicated.
1-conduit Models
Roller Lever (Resin Lever, Resin Roller) D4N-1@20 D4N-2@20 D4N-3@20 D4N-4@20 D4N-9@20 (See note 17.5 dia. resin roller
(27) 11±0.2
Roller Lever (Metal Lever, Resin Roller) D4N-1@22 D4N-2@22 D4N-3@22 D4N-4@22 39.5± D4N-9@22 (See note 17.5 dia. resin roller
(31) 11±0.2
Resin lever
20.5 20.5
27.5
Metal lever
20.5 20.5
27.5
9±0.2 47±0.2
9±0.2
21.5
20±0.1 22±0.1
21.5
20±0.1 22±0.1
47±0.2
2.15±0.05R mounting holes
2.15±0.05R mounting holes
22±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
22±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
Roller Lever (Metal Lever, Metal Roller) D4N-1@25 D4N-2@25 D4N-3@25 D4N-4@25 D4N-9@25 (See note 17.5 dia.stainless sintered 39.5±
Roller Lever (Metal Lever, Bearing Roller) D4N-1@26 D4N-2@26 D4N-3@26 D4N-4@26 43.6± D4N-9@26 (See note dia.
steel roller
Bearing roller
(31.5) 11±0.2
(31) 11±0.2
Metal lever
Metal lever 20.5 20.5
27.5
9±0.2 47±0.2
20.5 20.5
27.5 21.5
20±0.1 22±0.1
9±0.2
21.5
20±0.1 22±0.1
47±0.2
2.15±0.05R mounting holes
2.15±0.05R mounting holes
22±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
22±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions. Refer page details connectors.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model D4N-@120 D4N-@220 D4N-@B20 D4N-@D20 -(80° D4N-@122 D4N-@222 D4N-@B22 D4N-@D22 D4N-@125 D4N-@225 D4N-@B25 D4N-@D25 D4N-@126 D4N-@226 D4N-@B26 D4N-@D26
Slow-action (1NC/1NO) (2NC/1NO)
Model D4N-@A20 D4N-@C20 D4N-@E20 D4N-@F20 (44° 27.5° 36.5° (18° -(80° D4N-@A22 D4N-@C22 D4N-@E22 D4N-@F22 D4N-@A25 D4N-@C25 D4N-@E25 D4N-@F25 D4N-@A26 D4N-@C26 D4N-@E26 D4N-@F26
max. min. (See note (2nd) (See note (See note (2nd) (See note min. (See note
max. min. min. max. (See note (See note min. (See note min. (See note
min. (See note min. (See note
Note:
Variation occurs simultaneity contact opening/closing operations 2NC, 2NC/1NO, contacts. Check contact operation. Only snap-action models. Reference value. Only slow-action models. safe use, always make sure that minimum values greater provided.
Note: These values possible when contacts open (OFF). These values possible when contacts closed (ON). Only models. Reference values models only. Reference values. safe use, always make sure that minimum values greater provided.
Miniature Safety Limit Switch
1-conduit Models
Plunger D4N-1@31 D4N-2@31 D4N-3@31 D4N-4@31 D4N-9@31 (See note Roller Plunger D4N-1@32 D4N-2@32 D4N-3@32 D4N-4@32 D4N-9@32 (See note
25±0.1
Two, 3±0.05 dia. holes dia. 6-dia. resin plunger
9±0.2 47±0.2 20±0.1 22±0.1
(31.5) 21.5 11±0.2
9±0.2 47±0.2
20.5 20.5 dia. resin roller
25.2
(31.5) 21.5 11±0.2
20±0.1 22±0.1
2.15±0.05R mounting holes
2.15±0.05R mounting holes
22±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
22±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
One-way Roller Lever (Horizontal) D4N-1@62 D4N-2@62 D4N-3@62 D4N-4@62 D4N-9@62 (See note
One-way Roller Lever (Vertical) D4N-1@72 D4N-2@72 D4N-3@72 D4N-4@72 D4N-9@72 (See note
Operating direction
14.8 11±0.2 13.5
dia. resin roller
9±0.2 20±0.1 22±0.1 47±0.2
(31.5) 21.5 11±0.2
11±0.2
dia. resin roller
(31.5) 21.5 11±0.2
14.7 10.2 10.2
9±0.2 47±0.2 20±0.1 22±0.1
19.5±0.2
23.3 19.5±0.2
2.15±0.05R mounting holes Operating direction
2.15±0.05R mounting holes
22±0.2 max. 22±0.2 max.
Conduit
14.2
Conduit
14.2
Two, dia. holes Depth:
+0.15
Two, 4+0.15 dia. holes Depth:
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions. Refer page details connectors.
Miniature Safety Limit Switch
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model D4N-@131 D4N-@231 D4N-@B31 D4N-@D31 18.2 ±0.5 D4N-@132 D4N-@232 D4N-@B32 D4N-@D32 28.6 ±0.8 D4N-@162 D4N-@262 D4N-@B62 D4N-@D62 D4N-@172 D4N-@272 D4N-@B72 D4N-@D72 Note: Variation occurs simultaneity contact opening/closing operations 2NC, 2NC/1NO, contacts. Check contact operation. Only snap-action models. Reference value. Only slow-action models. safe use, always make sure that minimum values greater provided.
max. min. max. min. max. (See note (See note min. (See note min. (See note
±0.8 ±0.8
Slow-action (1NC/1NO) (2NC/1NO)
Model D4N-@A31 D4N-@C31 D4N-@E31 D4N-@F31 (2.9 18.2 ±0.5 17.4 ±0.5 D4N-@A32 D4N-@C32 D4N-@E32 D4N-@F32 (2.9 28.6 ±0.8 D4N-@A62 D4N-@C62 D4N-@E62 D4N-@F62 (5.2 (1.5 D4N-@A72 D4N-@C72 D4N-@E72 D4N-@F72 (4.3 (1.5 Note: These values possible when contacts open (OFF). These values possible when contacts closed (ON). Only models. Reference values models. Only models. Reference value. safe use, always make sure that minimum values greater provided.
max. min. max. (See note (2nd) (See note max. (See note (2nd) (See note min. (See note (See note min. (See note min. (See note
±0.8 ±0.8
±0.8 ±0.8 26.1 ±0.8
Miniature Safety Limit Switch
1-conduit Models
Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) D4N-1@2G D4N-2@2G D4N-3@2G D4N-4@2G D4N-9@2G (See note 17.5 dia.
resin roller
45±1 39.5±1 (31) 11±0.2
Adjustable Roller Lever, Form Lock (with Metal Lever, Rubber Roller) D4N-1@2H D4N-2@2H D4N-3@2H D4N-4@2H D4N-9@2H (See note dia. roller rubber
Bearing
48.2±1 41.3±1 (29.2)
20.5 20.5
11±0.2
27.5
9±0.2 47±0.2 20±0.1 22±0.1
27.5
9±0.2
21.5
47±0.2 20±0.1 22±0.1
21.5
2.15±0.05R mounting holes
2.15±0.05R mounting holes Stainless steel lever
22±0.2 max.
Conduit
14.2 Two, 4+0.15 dia. holes
Depth:
22±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions. Refer following diagrams details connectors.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model D4N-@12H D4N-@22H D4N-@B2H D4N-@D2H -(80° D4N-@12G D4N-@22G D4N-@B2G D4N-@D2G (See note
max. min. min. max. (See note (See note min. (See note min. (See note
Note: Variation occurs simultaneity contact opening/closing operations 2NC, 2NC/1NO, contacts. Check contact operation. operating characteristics these Switches were measured with roller lever Only snap-action models. Reference value. Only slow-action models. safe use, always make sure that minimum values greater provided.
Slow-action (1NC/1NO) (2NC/1NO)
Model D4N-@A2H D4N-@C2H D4N-@E2H D4N-@F2H (44° 27.5° 36.5° (18° -(80° D4N-@A2G D4N-@C2G D4N-@E2G D4N-@F2G (See note
max. min. (See note (2nd) (See note (See note (2nd) (See note min. (See note min. min. (See note
Note: operating characteristics these Switches were measured with roller lever This value possible when contacts open (OFF). This value possible when contacts closed (ON). Only models. Reference value models only. Reference value. safe use, always make sure that minimum values greater provided.
1-conduit Connector D4N-9@@@
(14) 14.2
Miniature Safety Limit Switch
1-conduit Models
Fork Lever Lock (Right Operation) D4N-1@RE D4N-2@RE D4N-3@RE D4N-4@RE
Two, 17.5 dia. rubber rollers
Fork Lever Lock (Left Operation) D4N-1@LE D4N-2@LE D4N-3@LE D4N-4@LE
max. 39.3±1 (27.2) 11±0.2 max. 39.3±1 (27.2) 11±0.2
Two, 17.5 dia. rubber rollers
20.5 20.5
20.5 20.5
27.5
20±0.1 22±0.1 47±0.2
47±0.2
27.5
9±0.2
9±0.2
21.5 21.5
20±0.1 22±0.1
2.15±0.05R mounting holes Two, 4+0.15 dia. holes 14.2 Depth:
2.15±0.05R mounting holes
Conduit
22±0.2 Conduit max.
14.2
Two, dia. holes Depth:
+0.15
22±0.2 max.
Whisker D4N-1@80 D4N-3@80
D4N-2@80 D4N-4@80
1.2-dia. stainless steel wire
Plastic D4N-1@87 D4N-3@87
D4N-2@87 D4N-4@87
20.5 20.5
Resin
(See note 21.5
20.5 20.5 Sealing
(See note 143.1 (50.1)
21.5
16.6 dia. Sealing
12±0.2 47±0.2 20±0.1 22±0.1 9±0.2
16.6 dia.
11±0.2
11±0.2
9±0.2 47±0.2 20±0.1 22±0.1
2.15±0.05R mounting holes
22±0.2 max.
2.15±0.05R mounting holes
Conduit
22±0.2 max.
Conduit
14.2 Two, 4+0.15 dia. holes
14.2 (31.5)
(31.5)
Depth:
Two, 4+0.15 dia. holes Depth:
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions. within actuator keep total travel less.
Slow-action (1NC/1NO) (2NC/1NO) (2NC) (3NC)
Model Force necessary reverse direction lever: max. D4N-@@RE D4N-@@LE ±10° 6.5° (MBB: 18.5° (MBB:
Note: Variation occurs simultaneity contact opening/closing operations 2NC, 2NC/1NO, contacts. Check contact operation.
Movement until lever revers- ±10° Movement until switch operation 6.5° (NC) (MBB: Movement until switch operation 18.5° (NO) (MBB:
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model max. max. D4N-@@80 D4N-@@87
Miniature Safety Limit Switch
2-conduit Models
Roller Lever (Resin Lever, Resin Roller) D4N-5@20 17.5 dia. D4N-6@20 resin roller D4N-8@20
Resin lever
20±0.1 22±0.1 40±0.1 42±0.1 9±0.2 39±0.2
dia.
47±1 40±1 (27) 11±0.2 20.5 20.5 27.5 21.5 20.5
Roller Lever (Metal Lever, Resin Roller) D4N-5@22 D4N-6@22 17.5 dia. resin roller D4N-8@22
Metal lever
45±1 39.5±1 (31) 11±0.2
20.5 20.5
9±0.2 20±0.1 22±0.1 40±0.1 42±0.1 39±0.2
dia.
27.5 21.5 20.5
2.15±0.05R mounting holes Conduit
42±0.2 max.
2.15±0.05R mounting holes Conduit
42±0.2 max.
14.2
Two, 4+0.15 dia. holes Depth:
14.2
Two, 4+0.15 dia. holes Depth:
Plunger D4N-5@31 D4N-6@31 D4N-8@31
25±0.1
dia.
Two, 3±0.05 dia. holes
6-dia. resin plunger
20±0.1 22±0.1 40±0.1 42±0.1 9±0.2 39±0.2
dia.
(31.5) 21.5 11±0.2
Roller Plunger D4N-5@32 D4N-6@32 D4N-8@32
25.2
20.5 20.5
dia. resin roller
9±0.2
(31.5) 21.5 11±0.2
2.15±0.05R mounting holes Conduit
20.5
2.15±0.05R mounting holes Conduit
20±0.1 22±0.1 40±0.1 42±0.1
39±0.2
dia.
20.5
42±0.2 max. 14.2
42±0.2 max.
14.2
Two, 4+0.15 dia. holes Depth:
Two, 4+0.15 dia. holes Depth:
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model D4N-@120 D4N-@220 D4N-@B20 D4N-@D20 -(80° D4N-@122 D4N-@222 D4N-@B22 D4N-@D22 -(80° D4N-@131 D4N-@231 D4N-@B31 D4N-@D31 ±0.5 D4N-@132 D4N-@232 D4N-@B32 D4N-@D32 28.2 ±0.8
Slow-action (1NC/1NO) (2NC/1NO)
Model D4N-@A20 D4N-@C20 D4N-@E20 D4N-@F20 (44° D4N-@A22 D4N-@C22 D4N-@E22 D4N-@F22 (44° D4N-@A31 D4N-@C31 D4N-@E31 D4N-@F31 (2.9 D4N-@A32 D4N-@C32 D4N-@E32 D4N-@F32 (2.9 28.2 ±0.8 ±0.8
max. min. (See note (2nd) (See note (See note (2nd) (See note min. (See note (See note min. (See note min. (See note
max. min. min. max. (See note (See note min. (See note min. (See note
27.5° 36.5° 27.5° 36.5° (18° -(80° (18° -(80° ±0.5 17.4 ±0.5
Note: Variation occurs simultaneity contact opening/closing operations 2NC, 2NC/1NO, contacts. Check contact operation. Only snap-action models. Reference value. Only slow-action models. safe use, always make sure that minimum values greater provided.
Note:
This value possible when contacts open (OFF). This value possible when contacts closed (ON). Only models. Reference value models. Only models. Reference value. use, always safe provided.make sure that minimum values greater
Miniature Safety Limit Switch
2-conduit Models
One-way Roller Lever Operating direction (Horizontal) 14.8 D4N-5@62 dia. D4N-6@62 ±0.2 resin roller D4N-8@62
13.5
(31.5) 21.5 11±0.2
One-way Roller Lever (Vertical) D4N-5@72 D4N-6@72 D4N-8@72 11±0.2
10.2 21.5 20.5
(31.5)
dia. resin roller
14.7
21.5 11±0.2
9±0.2 20±0.1 22±0.1 40±0.1 42±0.1 39±0.2
dia.
23.3 19.5±0.2
10.2
20±0.1 22±0.1 40±0.1 42±0.1 9±0.2
19.5±0.2
2.15±0.05R mounting holes
Conduit
21.5 20.5
39±0.2
dia.
42±0.2 max.
14.2
2.15±0.05R mounting holes Conduit
42±0.2 max.
Two, 4+0.15 dia. holes Depth:
Operating direction
14.2
Two, 4+0.15 dia. holes Depth:
Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) 17.5 dia. D4N-6@2G resin roller D4N-8@2G
Resin lever 2.15±0.05R mounting holes
45±1 39.5±1 (31) 11±0.2
Adjustable Roller Lever, Form Lock (with Metal Lever, Rubber Roller) dia. D4N-6@2H rubber roller D4N-8@2H Bearing
20.5 20.5 2.15±0.05R mounting holes
48.2±1 41.3±1 (29.2)
11±0.2
9±0.2 39±0.2
dia.
27.5 21.5 20.5
Stainless steel lever
9±0.2 39±0.2
dia.
20.5 20.5
27.5 21.5 20.5
20±0.1 22±0.1 40±0.1 42±0.1
42±0.2 max.
Conduit
14.2
20±0.1 22±0.1 40±0.1 42±0.1
42±0.2 max.
Conduit
14.2
Two, 4+0.15 dia. holes Depth:
Two, 4+0.15 dia. holes Depth:
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model D4N-@162 D4N-@262 D4N-@B62 D4N-@D62 ±0.8 D4N-@172 D4N-@272 D4N-@B72 D4N-@D72 ±0.8 D4N-@12G D4N-@22G D4N-@B2G D4N-@D2G (See note -(70° D4N-@12H D4N-@22H D4N-@B2H D4N-@D2H (See note -(70°
Slow-action (1NC/1NO) (2NC/1NO)
Model D4N-@A62 D4N-@C62 D4N-@E62 D4N-@F62 (5.2 (1.5 ±0.8 ±0.8 D4N-@A72 D4N-@C72 D4N-@E72 D4N-@F72 (4.3 (1.5 ±0.8 26.1 ±0.8 D4N-@A2G D4N-@C2G D4N-@E2G D4N-@F2G (See note (44° 27.5° 36.5° (18° -(70° D4N-@A2H D4N-@C2H D4N-@E2H D4N-@F2H (See note (44° 27.5° 36.5° (18° -(70°
max. min. max. (See note (2nd) (See note max. (See note (2nd) (See note min. (See note (See note min. (See note min. (See note Note:
max. min. max. min. max. (See note (See note min. (See note min. (See note Note:
Variation occurs simultaneity contact opening/closing operations 2NC, 2NC/1NO, contacts. Check contact operation. operating characteristics these Switches were measured with roller lever operating characteristics these Switches were measured with roller lever Only snap-action models. Reference value. Only slow-action models. safe use, always make sure that minimum values greater provided.
operating characteristics these Switches were measured with roller lever operating characteristics these Switches were measured with roller lever This value possible when contacts open (OFF). This value possible when contacts closed (ON). Only models. Reference value models only. Only models. Reference value. safe use, always make sure that minimum values greater provided.
Miniature Safety Limit Switch
2-conduit Models
Fork Lever Lock (Right Operation) D4N-5@RE D4N-6@RE D4N-7@RE D4N-8@RE Fork Lever Lock (Left Operation) D4N-5@LE D4N-6@LE D4N-7@LE D4N-8@LE
max. 39.3±1 (27.2) 11±0.2
Two, 17.5 dia. rubber rollers
Two, 17.5 dia. rubber rollers
max. 39.3±1 (27.2) 11±0.2 27.5 21.5
20.5 20.5
20±0.1 22±0.1 40±0.1 42±0.1 9±0.2 39±0.2 dia.
20.5 20.5
20±0.1 22±0.1 40±0.1 42±0.1 9±0.2 39±0.2
dia.
20.5
27.5 21.5 20.5
2.15±0.05R mounting holes
Conduit
2.15±0.05R mounting holes Conduit
Two, 4+0.15 dia. holes Depth:
14.2
42±0.2 max.
42±0.2 max.
14.2 Two, 4+0.15 dia. holes
Depth:
Whisker D4N-5@80 D4N-7@80
D4N-6@80 D4N-8@80
1.2-dia. stainless steel wire
Plastic D4N-5@87 D4N-7@87
D4N-6@87 D4N-8@87
Sealing
20±0.1 22±0.1 40±0.1 42±0.1
(See note 20.5 20.5 143.1 (50.1)
9±0.2
21.5 16.6 dia. 11±0.2
12±0.2
Resin (See note Sealing
9±0.2 20±0.1 22±0.1 40±0.1 42±0.1
21.5 16.6 dia. 11±0.2
2.15±0.05R mounting holes
Conduit
39±0.2 dia.
20.5
42±0.2 max.
2.15±0.05R mounting holes
39±0.2
dia.
20.5
42±0.2 max.
14.2
Conduit
(31.5)
Two, 4+0.15 dia. holes Depth:
14.2 (31.5)
Two, 4+0.15 dia. holes Depth:
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions. within actuator keep total travel less. usable range moving part less entire spring length from spring.
Slow-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Model Force necessary reverse direction lever: max. D4N-@@RE D4N-@@LE ±10° (6.5° (MBB: (18.5° (MBB:
Note: Variation occurs simultaneity contact opening/closing operations 2NC, 2NC/1NO, contacts. Check contact operation.
Movement until lever revers- ±10° Movement until switch operation (6.5° (NC) Movement until switch operation (18.5° (NO)
Snap-action (1NC/1NO), Slow-action (2NC) (3NC)
Model max. max. D4N-@@80 D4N-@@87
Miniature Safety Limit Switch
Levers
Refer following angles positions watchdogs (source: EN50047.)
Roller Lever (D4N-@@20)
Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) (D4N-@@2G) (Reference Values)
40±2 40±2
min.
Adjustable Roller Lever, Form Lock (with Metal Lever, Rubber Roller) (D4N-@@2H) (Reference Values)
30±7 42±2
min.
29±7 11±3
15±3
min.
min.
min.
min.
min.
min.
40+1
min.
70+1 55+1
55+1 35+1
Sealed Plunger (D4N-@@31)
12.5 -2.5
Roller Plunger (D4N-@@32)
12.5 -2.5
10±1.5
Operating position
Operating position
min.
min. 18±0.5 min.
25+1
min.
min. 28±1
min.
One-way Roller Lever (Horizontal) (D4N-@@62)
12.5 -2.5
One-way Roller Lever (Vertical) (Reference Values) (D4N-@@72)
12.5 -2.5
10±2 min. 31+1
max.
min.
min. min.
min.
41±2
22+1 min.
Fork Lever Lock (Right Operation) (D4N-@@RE)
Fork Lever Lock (Left Operation) (D4N-@@LE)
Mounting surface Mounting surface setting range
setting range
Note: Unless otherwise specified, tolerance ±0.4 applies dimensions.
Miniature Safety Limit Switch
Safety Precautions
Refer OMRON SAFETY COMPONENTS SERIES (Y106) common precautions Switches Safety Limit Switches.
Mounting Method
Mounting Screw Tightening Torque
Tighten each screws specified torque. Loose screws result malfunction Switch within short time. Terminal screw Cover clamping screw Head clamping screw Lever clamping screw Body clamping screw Conduit mounting connection, adaptor screw (except 1/214NPT) (1/2-14NPT)
CAUTION
metal connectors metal conduits with this Switch. Doing occasionally result electric shock.
Precautions Safe
drop Switch. Doing result Switch performing full capacity. attempt disassemble modify Switch. Doing cause Switch malfunction. Switch where explosive gas, flammable gas, other hazardous present. Switch submerged water, locations continuously subject splashes water. Doing result water entering Switch interior. (The IP67 degree protection specification Switch refers water penetration while Switch submersed water specified period time.) Protect head from foreign material. Subjecting head foreign material result premature wear damage Switch. Although switch body protected from penetration dust water, head protected from penetration minute particles water. Turn power before wiring. Doing result electric shock. Install cover after wiring. doing result electric shock. Connect fuse Switch series protect Switch from short-circuit damage. fuse with breaking current times larger than rated current. conform ratings, IEC60269-compliant 10-A fuse type switch circuits more standard loads (250 VAC, same time. Doing adversely affect insulation performance. durability Switch greatly affected operating conditions. Evaluate Switch under actual working conditions before permanent installation within number switching operations that will adversely affect Switch's performance. sure indicate machine manufacturer's instruction manual that user must attempt repair maintain Switch must contact machine manufacturer repairs maintenance. Check Switches before inspect regularly, replacing them when necessary. Switch kept pressed extended period time, components deteriorate quickly, Switch release.
Switch Mounting
Mount Switch using screws washers tighten screws specified torque. safety, screws that cannot easily removed, equivalent measure ensure that Switch secure. Secure Switch with bolts washers. Provide studs with diameter 4-0.05/-0.15 height max. places, inserting into holes bottom Switch shown below that Switch firmly fixed four points.
Precautions Correct
Environment
Switch intended indoor only. Switch outdoors. Doing cause Switch malfunction. Switch where hazardous gases (e.g., H2S, SO2, NH3, HNO3, CI2) present locations subject high temperature humidity. Doing result damage Switch caused contact failure corrosion. Switch under following conditions. Locations subject extreme temperature changes. Locations where high humidity condensation occur. Locations subject excessive vibration. Locations where metal dust, processing waste, oil, chemicals penetrate through protective door. Locations subject detergents, thinner, other solvents.
Switch Mounting Holes One-conduit Type
Two, 2.5±0.1 20±0.1 22±0.1 47±0.1
22±0.1
-0.15 dia. Height: max.
-0.05
Miniature Safety Limit Switch
Two-conduit Type
Two, 2.5±0.1 5.35±0.1 20±0.1 22±0.1 40±0.1 42±0.1
dia.: dia.:
39±0.1
Crimp terminal
Terminal screw
42±0.1
4-0.05 dia. -0.15 Height: max.
Make sure that contacts actuator right angle. Applying load switch actuator (roller) slant result deformation damage actuator rotary shaft.
Correct
Incorrect
Contact Arrangement
following diagrams show contact arrangements used screw terminal types connector types.
Screw Terminal Type
Wiring
When connecting terminals insulating tube M3.5 crimp terminals, arrange crimp terminals shown below that they rise onto case cover. Applicable lead wire size: AWG20 AWG18 (0.5 0.75 mm2). lead wires appropriate length, shown below. doing result excess length causing cover rise properly.
D4N-@D@@ (3NC)
D4N-@C@@ (2NC/1NO) D4N-@F@@ (2NC/1NO (MBB))
D4N-@B@@ (2NC) D4N-@2@@ (2NC (SNAP))
D4N-@A@@ (1NC/1NO) D4N-@E@@ (1NC/1NO (MBB))
One-conduit Type Poles)
D4N-@1@@ (1NC/1NO (SNAP))
Tolerance
Connector Type
D4N-9B@@ (2NC) D4N-92@@ (2NC (SNAP))
Two-conduit Type Poles)
Left hand
Right hand
D4N-9A@@ (1NC/1NO) D4N-9E@@ (1NC/1NO (MBB))
Tolerance
D4N-91@@ (1NC/1NO (SNAP))
Tolerance
push crimp terminals into gaps case interior. Doing cause damage deformation case. crimp terminals more than thickness. Otherwise, they will interfere with other components inside case. crimp terminals shown below more than thick. Manufacture J.S.T. Type Wire size
(Terminal No.)
Applicable socket: XS2F (OMRON). Refer G010 Connector Catalog details socket numbers lead wire colors.
FV0.5-3.7 type) AWG20 (0.5 mm2) V0.5-3.7 (straight type)
Socket Tightening (Connector Type)
Turn socket connector screws hand tighten until space remains between socket plug. Make sure that socket connector tightened securely. Otherwise, rated degree protection (IP67) maintained vibration loosen socket connector.
J.S.T Japanese manufacturer.
Conduit Opening
Connect recommended connector opening conduit tighten connector specified torque. case damaged excessive tightening torque applied. When using 1/2-14NPT, wind sealing tape around joint between connector conduit opening that enclosure will conform IP67.
Miniature Safety Limit Switch
cable with suitable diameter connector. Attach tighten conduit unused conduit opening when wiring. Tighten conduit specified torque. conduit provided with Switch (2-conduit types).
LAPP connectors together with seal packing (JPK-16, GP-13.5, GPM20, GPM12), tighten specified tightening torque. Seal packing sold separately. LAPP German manufacturer. Denki Japanese manufacturer. Before using type, attaching provided changing adaptor Switch then connect recommended connector. Before using 2-conduit 1/2-14NPT type, attach provided changing adaptor Switch then connect recommended connector.
Changing Lever
lever mounting screws used lever position position 360° angle 7.5° increments. Grooves incised lever rotary shaft that engage prevent lever from slipping against rotary shaft. screws adjustable roller lever models also loosened change length lever. Remove screws from front lever before mounting lever reverse (front/back), level that operation will completed before exceeding range 180° horizontal.
Storage
store Switch locations where hazardous gases (e.g., H2S, SO2, NH3, HNO3, Cl2) dust present, locations subject high temperatures humidity.
Recommended Connectors
connectors with screws exceeding otherwise screws will protrude into case interior, interfering with other components case. connectors listed following table have connectors with thread sections exceeding recommended connectors ensure conformance IP67. Size G1/2 Manufacturer LAPP Denki Pg13.5 1/2-14NPT LAPP LAPP LAPP LAPP Model ST-PF1/2 5380-1002 OA-W1609 OA-W1611 ST-13.5 5301-5030 ST-M20 5311-1020 ST-NPT1/2 5301-6030 ST-M12 5311-1000 Applicable cable diameter 12.0 11.0 12.0 13.0 12.0
Others
allow load current exceed rated value. Confirm that seal rubber defects before use. seal rubber displaced raised, foreign particles adhered sealing capability seal rubber will adversely affected. correct cover mounting screws only, sealing capability seal rubber will deteriorate. Inspect Switch regularly. Make sure that foreign particles enter head when removing screws from four corners change head position four directions. following recommended countermeasures prevent telegraphing when using adjustable long levers. Make rear edge smooth with angle make shape quadratic curve. Design circuit that error signal will generated. Switch that operated direction only.
Production Termination
Following release D4N, production D4D-N will terminated.
Comparison D4D-N Substitute Products
Model Switch color Dimensions Wiring/connection Mounting method Ratings/performance Operating characteristics Operating method Very similar Very similar Significantly different Completely compatible Very similar Very similar Completely compatible
Date Production Termination
Production D4D-N Series will terminated March 2006.
Product Replacement
Dimensions D4D-N same mounting method, mounting hole. multi-contact structure extra length, however, different. Terminal Numbers 2-contact slow-action model, terminals D4D-N D4N. Recommended Terminals recommended terminals used, Switch compatible. Make sure that Switch compatible with terminals.
Miniature Safety Limit Switch
Dimensions (Unit:
Discontinued Models (1-conduit Plunger-type D4D-N)
dia. ±0.1
Replacement Products (1-conduit Plunger-type D4N)
25±0.1
Two, ±0.05 dia. holes dia.
Two, ±0.05 dia. holes dia.
6-dia. resin plunger
6-dia. resin plunger
9±0.2 20±0.1 22±0.1
(31.5) 21.5 11±0.2
2.15±0.05R mounting holes
47±0.2
2.15±0.05R mounting holes
Two, 4+0.15 dia. holes depth:
max.
(See note.)
22±0.2 max.
Conduit (See note.)
14.2
Two, 4+0.15 dia. holes depth:
Discontinued Models (2-conduit Plunger-type D4D-N)
Two, ±0.05 dia. holes depth:
Replacement Products (2-conduit Plunger-type D4N)
25±0.1
dia. dia.
Two, ±0.05 dia. holes dia.
6-dia. resin plunger
20±0.1 22±0.1 40±0.1 42±0.1 9±0.2 39±0.2 dia.
(31.5) 21.5 11±0.2
2.15±0.05R mounting holes
(See note.)
max.
dia.
2.15±0.05R mounting holes
Conduit (See note.)
20.5
42±0.2 max.
Two, 4+0.15 dia. holes depth:
14.2 Two, 4+0.15 dia. holes
depth:
List Recommended Substitute Products
actuator D4D-N non-safety type. recommended safety applications (form lock type). sure mount correctly. screws recommended comply with European standards. Therefore, type recommended substitute when PG13.5 conduit-type available model.
Safety Limit Switches
D4D-N product discontinued D4D-1120N D4D-2120N D4D-3120N D4D-5120N D4D-6120N D4D-1122N D4D-2122N D4D-3122N D4D-5122N D4D-6122N D4D-1125N D4D-2125N D4D-3125N D4D-1131N D4D-2131N D4D-3131N D4D-5131N Recommended substitute product D4N-1120 D4N-2120 D4N-3120 D4N-5120 D4N-6120 D4N-1122 D4N-2122 D4N-3122 D4N-5122 D4N-6122 D4N-1125 D4N-2125 D4N-3125 D4N-1131 D4N-2131 D4N-3131 D4N-5131 D4D-N product discontinued D4D-1520N D4D-2520N D4D-3520N D4D-5520N D4D-6520N D4D-1522N D4D-2522N D4D-3522N D4D-5522N D4D-6522N D4D-1525N D4D-2525N D4D-3525N D4D-1531N D4D-2531N D4D-3531N D4D-5531N Recommended substitute product D4N-1A20 D4N-2A20 D4N-3A20 D4N-5A20 D4N-6A20 D4N-1A22 D4N-2A22 D4N-3A22 D4N-5A22 D4N-6A22 D4N-1A25 D4N-2A25 D4N-3A25 D4N-1A31 D4N-2A31 D4N-3A31 D4N-5A31 D4D-N product discontinued D4D-1A20N D4D-2A20N D4D-3A20N D4D-5A20N D4D-6A20N D4D-1A22N D4D-2A22N D4D-3A22N D4D-5A22N D4D-6A22N D4D-1A25N D4D-2A25N D4D-3A25N D4D-1A31N D4D-2A31N D4D-3A31N D4D-5A31N Recommended substitute product D4N-1B20 D4N-2B20 D4N-3B20 D4N-5B20 D4N-6B20 D4N-1B22 D4N-2B22 D4N-3B22 D4N-5B22 D4N-6B22 D4N-1B25 D4N-2B25 D4N-3B25 D4N-1B31 D4N-2B31 D4N-3B31 D4N-5B31
Miniature Safety Limit Switch
D4D-N product discontinued D4D-6131N D4D-1132N D4D-2132N D4D-3132N D4D-5132N D4D-6132N D4D-1162N D4D-2162N D4D-3162N D4D-5162N D4D-6162N D4D-1172N D4D-2172N D4D-3172N D4D-5172N D4D-6172N D4D-112HN D4D-212HN D4D-312HN
Recommended substitute product D4N-6131 D4N-1132 D4N-2132 D4N-3132 D4N-5132 D4N-6132 D4N-1162 D4N-2162 D4N-3162 D4N-5162 D4N-6162 D4N-1172 D4N-2172 D4N-3172 D4N-5172 D4N-6172 D4N-112H D4N-212H D4N-312H
D4D-N product discontinued D4D-6531N D4D-1532N D4D-2532N D4D-3532N D4D-5532N D4D-6532N D4D-1562N D4D-2562N D4D-3562N D4D-5562N D4D-6562N D4D-1572N D4D-2572N D4D-3572N D4D-5572N D4D-6572N D4D-152HN D4D-252HN D4D-352HN
Recommended substitute product D4N-6A31 D4N-1A32 D4N-2A32 D4N-3A32 D4N-5A32 D4N-6A32 D4N-1A62 D4N-2A62 D4N-3A62 D4N-5A62 D4N-6A62 D4N-1A72 D4N-2A72 D4N-3A72 D4N-5A72 D4N-6A72 D4N-1A2H D4N-2A2H D4N-3A2H
D4D-N product discontinued D4D-6A31N D4D-1A32N D4D-2A32N D4D-3A32N D4D-5A32N D4D-6A32N D4D-1A62N D4D-2A62N D4D-3A62N D4D-5A62N D4D-6A62N D4D-1A72N D4D-2A72N D4D-3A72N D4D-5A72N D4D-6A72N D4D-1A2HN D4D-2A2HN D4D-3A2HN
Recommended substitute product D4N-6B31 D4N-1B32 D4N-2B32 D4N-3B32 D4N-5B32 D4N-6B32 D4N-1B62 D4N-2B62 D4N-3B62 D4N-5B62 D4N-6B62 D4N-1B72 D4N-2B72 D4N-3B72 D4N-5B72 D4N-6B72 D4N-1B2H D4N-2B2H D4N-3B2H
General-purpose Limit Switches
D4D-N product discontinued D4D-1121N D4D-2121N D4D-3121N D4D-5121N D4D-6121N D4D-1127N D4D-2127N D4D-3127N D4D-5127N D4D-6127N D4D-1180N D4D-2180N D4D-3180N D4D-5180N D4D-6180N D4D-1187N D4D-2187N D4D-3187N D4D-5187N D4D-6187N Recommended substitute product D4N-112G D4N-212G D4N-312G D4N-512G D4N-612G D4N-112H D4N-212H D4N-312H D4N-512H D4N-612H D4N-4180 D4N-2180 D4N-3180 D4N-8180 D4N-6180 D4N-4187 D4N-2187 D4N-3187 D4N-8187 D4N-6187 D4D-N product discontinued D4D-15REN D4D-25REN D4D-35REN D4D-55REN D4D-65REN D4D-15LEN D4D-25LEN D4D-35LEN D4D-55LEN D4D-65LEN D4D-1521N D4D-2521N D4D-3521N D4D-5521N D4D-6521N D4D-1527N D4D-2527N D4D-3527N D4D-5527N D4D-6527N Recommended substitute product D4N-1ARE D4N-2ARE D4N-3ARE D4N-5ARE D4N-6ARE D4N-1ALE D4N-2ALE D4N-3ALE D4N-5ALE D4N-6ALE D4N-1A2G D4N-2A2G D4N-3A2G D4N-5A2G D4N-6A2G D4N-1A2H D4N-2A2H D4N-3A2H D4N-5A2H D4N-6A2H D4D-N product discontinued D4D-1AREN D4D-2AREN D4D-3AREN D4D-5AREN D4D-6AREN D4D-1ALEN D4D-2ALEN D4D-3ALEN D4D-5ALEN D4D-6ALEN D4D-1A21N D4D-2A21N D4D-3A21N D4D-5A21N D4D-6A21N D4D-1A27N D4D-2A27N D4D-3A27N D4D-5A27N D4D-6A27N D4D-1A80N D4D-2A80N D4D-3A80N D4D-5A80N D4D-6A80N D4D-1A87N D4D-2A87N D4D-3A87N D4D-5A87N D4D-6A87N Recommended substitute product D4N-1BRE D4N-2BRE D4N-3BRE D4N-5BRE D4N-6BRE D4N-1BLE D4N-2BLE D4N-3BLE D4N-5BLE D4N-6BLE D4N-1B2G D4N-2B2G D4N-3B2G D4N-5B2G D4N-6B2G D4N-1B2H D4N-2B2H D4N-3B2H D4N-5B2H D4N-6B2H D4N-4B80 D4N-2B80 D4N-3B80 D4N-8B80 D4N-6B80 D4N-4B87 D4N-2B87 D4N-3B87 D4N-8B87 D4N-6B87
Miniature Safety Limit Switch
Warranty Application Considerations
Read Understand this Catalog
Please read understand this catalog before purchasing products. Please consult your OMRON representative have questions comments.
Warranty Limitations Liability
WARRANTY OMRON's exclusive warranty that products free from defects materials workmanship period year other period specified) from date sale OMRON. OMRON MAKES WARRANTY REPRESENTATION, EXPRESS IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, FITNESS PARTICULAR PURPOSE PRODUCTS. BUYER USER ACKNOWLEDGES THAT BUYER USER ALONE DETERMINED THAT PRODUCTS WILL SUITABLY MEET REQUIREMENTS THEIR INTENDED USE. OMRON DISCLAIMS OTHER WARRANTIES, EXPRESS IMPLIED. LIMITATIONS LIABILITY OMRON SHALL RESPONSIBLE SPECIAL, INDIRECT, CONSEQUENTIAL DAMAGES, LOSS PROFITS, COMMERCIAL LOSS CONNECTED WITH PRODUCTS, WHETHER SUCH CLAIM BASED CONTRACT, WARRANTY, NEGLIGENCE, STRICT LIABILITY. event shall responsibility OMRON exceed individual price product which liability asserted. EVENT SHALL OMRON RESPONSIBLE WARRANTY, REPAIR, OTHER CLAIMS REGARDING PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, MAINTAINED SUBJECT CONTAMINATION, ABUSE, MISUSE, INAPPROPRIATE MODIFICATION REPAIR.
Application Considerations
SUITABILITY OMRON shall responsible conformity with standards, codes, regulations that apply combination products customer's application products. Take necessary steps determine suitability product systems, machines, equipment with which will used. Know observe prohibitions applicable this product. NEVER PRODUCTS APPLICATION INVOLVING SERIOUS RISK LIFE PROPERTY WITHOUT ENSURING THAT SYSTEM WHOLE BEEN DESIGNED ADDRESS RISKS, THAT OMRON PRODUCTS PROPERLY RATED INSTALLED INTENDED WITHIN OVERALL EQUIPMENT SYSTEM.
Disclaimers PERFORMANCE DATA
Performance data given this catalog provided guide user determining suitability does constitute warranty. represent result OMRON's test conditions, users must correlate actual application requirements. Actual performance subject OMRON Warranty Limitations Liability. CHANGE SPECIFICATIONS Product specifications accessories changed time based improvements other reasons. Consult with your OMRON representative time confirm actual specifications purchased product. DIMENSIONS WEIGHTS Dimensions weights nominal used manufacturing purposes, even when tolerances shown. DIMENSIONS SHOWN MILLIMETERS.
convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527.
Cat. C130-E1-01A interest product improvement, specifications subject change without notice.
OMRON Corporation
OMRON Corporation Industrial Automation Company Industrial Devices Components Division H.Q. Safety Components Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7093/Fax: (81)75-344-7113
Printed Japan 0204-3M (0204)

Other recent searches


XSUY43D - XSUY43D   XSUY43D Datasheet
TA49312 - TA49312   TA49312 Datasheet
PQ60010EML15 - PQ60010EML15   PQ60010EML15 Datasheet
KSC5302DI - KSC5302DI   KSC5302DI Datasheet
COP87LxxCJ - COP87LxxCJ   COP87LxxCJ Datasheet
BUZ11A - BUZ11A   BUZ11A Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive