| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Innovations Customer Satisfaction INTEGRAL ELECTRONICS (IEPE
Top Searches for this datasheetQuality Innovations Customer Satisfaction INTEGRAL ELECTRONICS (IEPE) PIEZOELECTRIC ACCELEROMETER Measurement Range Ground Isolation Impedance Output Connector Stud Mounted actual size MODEL 2012A Description Sensors Model 2012A stud mounted piezoelectric accelerometer designed general vibration measurement structures objects. offers measurement range with sensitivity mV/g. accelerometer transmits impedance voltage output through same cable that supplies constant current power. Model 2012A design sealed against external contamination. Signal return isolated from outer case unit. accelerometer features 10-32 connector that used with coaxial cable error-free operation. Sensors Signal Conditioner Models 5005, 5100 5102 recommended with this impedance accelerometer. M5(OUT) 10-32 (OUT) 10-32 S=0.689 S=17.5 (mm) 1.181 0.787 Typical Amplitude Response Typical Temperature Response 1000 10000 100000 FREQUENCY DEVIATION (-46) (10) (66) (121) (177) TEMPERATURE (°C) Sensors California, (949) 3558 (949) 0126 info@vipsensors.com www.vipsensors.com Sensors reserves right modify these specifications without notice. DEVIATION Quality Innovations Customer Satisfaction INTEGRAL ELECTRONICS (IEPE) PIEZOELECTRIC ACCELEROMETER SPECIFICATIONS following performance specifications conform ISA-RP-37.2 (1964) typical values, referenced +75°F (+24°C) unless otherwise noted. Calibration data, traceable National Institute Standards Technology (NIST), supplied. MODEL 2012A UNITS DYNAMIC CHARACTERISTICS Range Voltage Sensitivity, typical Transverse Sensitivity Frequency Response Resonance Frequency Amplitude Response Temperature Response Amplitude Linearity ELECTRICAL CHARACTERISTICS Output Polarity Power Source Voltage (Constant Current) Supply Current Bias Voltage Full Scale Output Voltage (peak) Output Impedance Noise Grounding (mm/s2) (m/s2) mV/g (mV/m/s2) (980.7) (5.10) Typical Amplitude Response 15,000 3,500 4,000 Typical Temperature Response Acceleration directed from base into transducer defined positive 7.8) Signal return isolated from case ENVIRONMENTAL CHARACTERISTICS Temperature Range Humidity Shock Limit (m/s2 Base Strain equiv. /µstrain Magnetic Field Sensitivity equiv. /gauss (/T) Thermal Transient Sensitivity equiv. PHYSICAL CHARACTERISTICS Weight Case Material Mounting Piezoelectric Material Structure Output Connector ACCESSORIES Included: 9005L10 Coaxial Cable 10-32/BNC, 10ft (3.3 9504-8 10-32/10-32 Mounting Stud Calibration Sheet -4°F 248°F (-20°C +120°C) Epoxy sealed 1,000 (9807) 0.0002 2E-5 0.008 (grams) (26) Stainless Steel 10-32, torque lbf-in) PZT-5 Annular Shear 10-32 receptacle, mounting Optional: 9006L10 Coaxial Cable 10-32/10-32, (3.3 9505-1 M5/10-32 Isolated Mounting Stud NOTES Short duration shock pulses, such those generated metal-to-metal impacts, excite transducer resonance cause linearity errors. Sensors California, (949) 3558 (949) 0126 info@vipsensors.com www.vipsensors.com Sensors reserves right modify these specifications without notice. Other recent searchesLM7301 - LM7301 LM7301 Datasheet CM900HB-90H - CM900HB-90H CM900HB-90H Datasheet 1SS337 - 1SS337 1SS337 Datasheet 1980950000 - 1980950000 1980950000 Datasheet
Privacy Policy | Disclaimer |