| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Innovations Customer Satisfaction INTEGRAL ELECTRONICS (IEPE
Top Searches for this datasheetQuality Innovations Customer Satisfaction INTEGRAL ELECTRONICS (IEPE) PIEZOELECTRIC ACCELEROMETER Outstanding Dynamic Range Wide Bandwidth Impedance Output Connector Hermetically Sealed Description Sensors Model 2011A stud mounted piezoelectric accelerometer designed general vibration measurement structures objects. features high signal-to-noise ratio, high output sensitivity, wide bandwidth. accelerometer transmits impedance voltage output through same cable that supplies constant current power. Model 2011A design welded stainless steel construction that hermetically sealed against external contamination. Signal ground connected outer case unit. When used with isolated mounting stud, accelerometer electrically isolated from ground. accelerometer features 10-32 connector that used with coaxial cable error-free operation. Sensors Signal Conditioner Models 5005, 5100 5102 recommended with this impedance accelerometer. 10-32(OUT) actual size MODEL 2011A 0.945 10-32 S=0.512 0.598 15.2) (S=13 (mm) Typical Amplitude Response 1000 FREQUENCY (-46) DEVIATION Typical Temperature Response 10000 100000 (10) (66) (121) (177) TEMPERATURE (°C) Sensors California, (949) 3558 (949) 0126 info@vipsensors.com www.vipsensors.com Sensors reserves right modify these specifications without notice. DEVIATION Quality Innovations Customer Satisfaction INTEGRAL ELECTRONICS (IEPE) PIEZOELECTRIC ACCELEROMETER SPECIFICATIONS following performance specifications conform ISA-RP-37.2 (1964) typical values, referenced +75°F (+24°C) unless otherwise noted. Calibration data, traceable National Institute Standards Technology (NIST), supplied. MODEL 2011A UNITS DYNAMIC CHARACTERISTICS Range Voltage Sensitivity, typical Transverse Sensitivity Frequency Response Resonance Frequency Amplitude Response Temperature Response Amplitude Linearity ELECTRICAL CHARACTERISTICS Output Polarity Power Source Voltage (Constant Current) Supply Current Bias Voltage Full Scale Output Voltage (peak) Output Impedance Noise Grounding (mm/s2) (m/s2) mV/g (mV/m/s2) (2451.7) (2.04) Typical Amplitude Response 35,000 6,000 8,000 Typical Temperature Response Acceleration directed from base into transducer defined positive 19.6) Signal ground connected case ENVIRONMENTAL CHARACTERISTICS Temperature Range Humidity Shock Limit (m/s2 Base Strain equiv. /µstrain Magnetic Field Sensitivity equiv. /gauss (/T) Thermal Transient Sensitivity equiv. PHYSICAL CHARACTERISTICS Weight Case Material Mounting Piezoelectric Material Structure Output Connector ACCESSORIES Included: 9005L10 Coaxial Cable 10-32/BNC, 10ft (3.3 9504-8 10-32/10-32 Mounting Stud Calibration Sheet -4°F 248°F (-20°C +120°C) Hermetically sealed, welded construction 3,000 (29,420) 0.0006 2E-5 (grams) (17) Stainless Steel 10-32, torque lbf-in) PZT-5 Center Compression 10-32 receptacle, mounting Optional: 9006L10 Coaxial Cable 10-32/10-32, (3.3 9505-8 10-32/10-32 Isolated Mounting Stud NOTES Short duration shock pulses, such those generated metal-to-metal impacts, excite transducer resonance cause linearity errors. Sensors California, (949) 3558 (949) 0126 info@vipsensors.com www.vipsensors.com Sensors reserves right modify these specifications without notice. Other recent searchesuPD3725A - uPD3725A uPD3725A Datasheet TMS320C6701 - TMS320C6701 TMS320C6701 Datasheet SC7461 - SC7461 SC7461 Datasheet LF147 - LF147 LF147 Datasheet LF247 - LF247 LF247 Datasheet LF347 - LF347 LF347 Datasheet CD74LPT16646 - CD74LPT16646 CD74LPT16646 Datasheet CAT3224 - CAT3224 CAT3224 Datasheet
Privacy Policy | Disclaimer |