| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
PART NUMBER: VWRAS2 series DESCRIPTION: dc/dc converter Desc
Top Searches for this datasheet02/2008 PART NUMBER: VWRAS2 series DESCRIPTION: dc/dc converter Description Designed convert wide input voltage range into isolated regulated voltage, VWRAS2-SIP series well suited providing board-mount local supplies wide range applications, including mixed analog/digital circuits, test measurement equip., process/machine controls, datacom/telecom fields, etc. Features (2:1) input range efficiency voltage output Isolation 1500VDC heatsink required circuit protection on/off >1,000,000 range: -40°C~+85°C Model Number VWRAS2-D5-D5-SIP VWRAS2-D5-D9-SIP VWRAS2-D5-D12-SIP VWRAS2-D5-D15-SIP VWRAS2-D12-D5-SIP VWRAS2-D12-D9-SIP VWRAS2-D12-D12-SIP VWRAS2-D12-D15-SIP VWRAS2-D24-D5-SIP VWRAS2-D24-D9-SIP VWRAS2-D24-D12-SIP VWRAS2-D24-D15-SIP VWRAS2-D48-D5-SIP VWRAS2-D48-D9-SIP VWRAS2-D48-D12-SIP VWRAS2-D48-D15-SIP Nominal Input Voltage Range 4.5~9.0 4.5~9.0 4.5~9.0 4.5~9.0 9.0~18.0 9.0~18.0 9.0~18.0 9.0~18.0 18.0~36.0 18.0~36.0 18.0~36.0 18.0~36.0 36.0~72.0 36.0~72.0 36.0~72.0 36.0~72.0 Max. Output Voltage Output Current Max. ±200 ±111 ±200 ±111 ±200 ±111 ±200 ±111 Min. Efficiency Package Style Note: specifications measured TA=25°C, humidity <75%, nominal input voltage rated output load unless otherwise specified. Output Specifications Item Output power Output voltage accuracy Line Regulation Load Regulation Temperature drift Output ripple& noise Switching frequency Test conditions Refer recommended circuit Input Voltage from high 100% full load Refer recommended circuit Bandwidth 100% load, nominal input Min. Typ. ±0.2 ±0.5 Max. ±0.5 ±1.0 0.03 550K Units %/°C mVp-p 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date 02/2008 PART NUMBER: VWRAS2 series DESCRIPTION: dc/dc converter General Specifications Output short circuit protection Temperature rise full load Cooling No-load power consumption Operating temperature range Storage temperature range Soldering temperature Storage humidity range Case material MTBF Continuous 15°C typ., 35°C max. Free convection 100mW (typical) -40°C +85°C -50°C +125°C 300°C (1.5mm from case 10sec.) <95% Plastic (UL94-V0) >1,000,000 hrs. Isolation Specifications Item Isolation Voltage Isolation Resistance Isolation Capacitance Test Conditions Flash tested min. Test Input/Output Min. 1500 1000 Typ. Max. Units Typical Characteristics RVc/I Recommended circuit best test with full load test without load. further reduce output ripple, increase external capacitor, choose capacitor with ESR, external inductor circuit shown left. General: Cin: 100µF 24V, 10µF 47µF Cout:100µF(typ) Lin: 4.7µH Lout: 2.2µH 10µH Outline Dimensions Recommended Layout Pattern First Angle Projection RECOMMENDED FOOTPRINT view,grid:2.54mm(0.1inch), diameter:1.00mm Dual Output Single Output +0.020 (0.866) 4.10 +0.50 12.00 FOOTPRINT DETAILS Dual CTRL Note: Unit:mm(inch) tolerances: +0.10mm( +0.004inch) General tolerances: +0.25mm( +0.010inch) 0.50 NC:No Connection 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date 02/2008 PART NUMBER: VWRAS2 series DESCRIPTION: dc/dc converter Application Notes: VWRAS2-SIP Series have been tested according following recommended testing circuit before leaving factory. This series should tested under load(Figure want further decrease input/output ripple, increase capacitance properly choose capacitors with ESR. However, capacitance should high(Table Input current Nominal input voltage range. input current power supply must sufficient startup current (Ip) DC/DC module (Figure Input Current(A) Table External Capacitor Table Single Vout(VDC) 9820 Cout(uF) 2200 1000 Dual Vout(VDC) Cout(uF) ±560 ±470 ±330 ±270 Input Voltage Range Input Voltage Output Load order ensure product operates efficiently reliably, make sure specified range input voltage exceeded. parallel connection plug play. Figure Temperature Derating Graph Terminals Unless otherwise specified, terminals series used converter's interior circuit connection, allowed connection external circuit. Operating Temp.( Remote on/off control (see figure When control (CTRL open 0.5mA, converter will have normal output. OFF: With 3-10mA input current (Ic) output will disabled. Under conditions should input current (Ic) exceed 20mA. Value Figure derived follows: 0.65V Voltage control input Diode (D1) voltage drop (.7V voltage drop typical Input Current (5mA recommended disable current) example Logic circuit Apply logic signal disable output 0.7V 0.65V .005A Choose resistor example Short Apply disable output 0.7V 0.65V 2130 .005A Choose resistor 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 Other recent searchesuPD61151 - uPD61151 uPD61151 Datasheet uPD61151MPEG2 - uPD61151MPEG2 uPD61151MPEG2 Datasheet uPD61151MPEG2MPEGDSP32RISC - uPD61151MPEG2MPEGDSP32RISC uPD61151MPEG2MPEGDSP32RISC Datasheet uPD61152uPD611151 - uPD61152uPD611151 uPD61152uPD611151 Datasheet uPD61151 - uPD61151 uPD61151 Datasheet Si4392DY - Si4392DY Si4392DY Datasheet MCF5249 - MCF5249 MCF5249 Datasheet LS393 - LS393 LS393 Datasheet HC393A - HC393A HC393A Datasheet L74VHC1G66 - L74VHC1G66 L74VHC1G66 Datasheet L74VHC4066 - L74VHC4066 L74VHC4066 Datasheet AP62T03GH - AP62T03GH AP62T03GH Datasheet A0704-01R1 - A0704-01R1 A0704-01R1 Datasheet
Privacy Policy | Disclaimer |