| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter
Top Searches for this datasheetPART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter features industry standard high efficiency switching frequency 8.3-14 wide input range 0.75-5.0 wide output range over temperature protection continuous short circuit protection remote on/off cost-efficient open frame design UL/C-UL60950-1 (E222736) certified INTRODUCTION VPOL5A-12-SIP CONVERTER FEATURES GENERAL DESCRIPTION Electrical Description Thermal Packaging Physical Design. TECHNICAL SPECIFICATIONS MAIN FEATURES FUNCTIONS Operating Temperature Range Over-Temperature Protection (OTP) Output Voltage Adjustment Safe Operating Area (SOA) Over Current Protection Remote ON/OFF UVLO (Under-Voltage Lockout) SAFETY Input Fusing Safety Considerations. APPLICATIONS APPLICATIONS Layout Design Challenges. Convection Requirements Cooling Thermal Considerations Power De-Rating Curves Efficiency Load Curves Input Capacitance Power Module Test Set-Up VPOL5A-12-SIP Output Voltage Adustment. Output Ripple Noise Measurement 7.10 Output Capacitance MECHANICAL OUTLINE DIAGRAMS VPOL5A-12-SIP Mechanical Outline Diagrams 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter converter overloaded ambient temperature gets Introduction This application note describes features functions V-Infinity's VPOL5A-12-SIP series non-isolated dc-dc converters. These highly efficient, reliable compact, high power density, single output DC/DC converters. These "Point Load" modules serve needs specifically fixed mobile telecommunications computing market, employing economical distributed Power Architectures. VPOL5A-12-SIP series provide precisely regulated output voltage range from 0.75V 5.0Vdc over wide range input voltage (Vi=8.3 14Vdc) operate over ambient temperature range -40°C +85°C. Ultr a-high efficiency operation achieved through synchronous rectification drive control techniques. modules fully protected against short circuit overtemperature conditions. V-Infinity's world class automated manufacturing methods, together with extensive testing qualification program, ensure that VPOL5A-12-SIP series converters extremely reliable. high, converter will shut down protect unit. +VIN ON/OFF trim TRIM Figure Electrical Block Diagram Thermal Packaging Physical Design. VPOL5A-12-SIP series uses multi-layer construction. surface mount power components placed side PCB, low-power control components placed other side. Thus, Heat dissipation power components optimized, ensuring that control components thermally stressed. converter open-frame product case case pin. open-frame design several advantages over encapsulated closed devices. Among these advantages are: Efficient Thermal Management: heat removed from heat generating components without heating more sensitive, small signal control components. Environmental: Lead free open-frame converters more easily re-cycled. Cost Efficient: encapsulation. Cost efficient open-frame construction. Reliable: Efficient cooling provided open frame construction offers high reliability easy diagnostics. VPOL5A-12-SIP Converter Features High efficiency topology, typically 3.3Vdc Industry standard footprint Wide ambient temperature range, -40°C +85°C Cost efficient open frame design Programmable output voltage external resistor from 0.75 5.0Vdc minimum load requirement (Stable loads) Remote ON/OFF Fixed switching frequency Continuous short-circuit protection over current protection Over-temperature protection (OTP) Monotonic Startup with pre-bias output. UL/IEC/EN60950 Certified. General Description Electrical Description block diagram VPOL5A-12-SIP Series converter shown Figure Extremely high efficiency power conversion achieved through synchronous rectification drive techniques. Essentially, powerful VPOL5A-12-SIP series topology based non-isolated synchronous buck converter. control loop optimized unconditional stability, fast transient response very tight line load regulation. typical pre-bias application VPOL5A-12SIP series converters draw reverse current start-up. output voltage adjusted from 0.75 5.0vdc, using TRIM with external resistor. converter shut down remote ON/OFF input that referenced ground. This input compatible with popular logic devices; 'positive' logic input supplied standard. Positive logic implies that converter enabled remote ON/OFF input high floating), disabled low. converter also protected against over-temperature conditions. 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter Technical Specifications (All specifications typical nominal input, full load 25°C unless otherwise noted.) PARAMETER ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Operating Temp erature Thermal Considerations Section Storage Temperature NOTES CONDITIONS Device Min. Typical Max. Units +125 INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Hysteresis Voltage Maximum Input Current Vin=0 14Vdc Io=Io,max. Vo=0.75V Vo=1.2V Vo=1.5V Vo=1.8V Vo=2.0V Vo=2.5V Vo=3.3V Vo=5.0V Shutdown input idle current No-Load Input Current Converter Input Current Inrush Current Input Reflected-Ripple Current thru inductor, 20MHz OUTPUT CHARACTERISTIC Output Voltage Point Output Voltage Trim Adjustment Range Output Voltage Regulation Load Regulation Line Regulation Tempera ture Coefficient Output Voltage Ripple Noise Peak-to-Peak External Capacitive Load Operating Output Current Range Output Current-Limit Inception Shout Circuit Protection Output Voltage =90% Nominal Output Voltage Continuous with Hiccup Mode Io=Io.min Io.max Vin=low line high line Ta=-40°C 85°C 20MHz bandwidth Full Load, ceramic 10uF tantalum Full Load, ceramic 10uF tantalum Other Voltages Vo=5V Other Voltages Vo=5V 3000 -0.5 -0.2 -0.03 +0.5 +0.2 +0.03 %/°C Vin=Nominal Io=Io.max, Tc=25 Selected external resistor -1.5% Vo,set +1.5% 0.7525 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter PARAMETER DYNAMIC CHARACTERISTICS Output Voltage Transient Response Error Brand Setting Time (within Vout nominal) NOTES CONDITIONS Device Min. Typical Max. Units Step Load Change, di/dt=0.1A/us Step Load Change, di/dt=0.1A/us EFFICIENCY Vo=0.75V Vo=1.2V Vo=1.5V Vo=1.8V Vo=2.0V Vo=2.5V Vo=3.3V Vo=5.0V Non-isolation 100% Load ISOLATION CHARACTERISTICS Input Output FEATURE CHARACTERISTICS Switching Frequency ON/OFF Control, Positive Logic Remote On/Off Logic (Module Off) Logic High (Module Standard Model Open Circuit Suffix Model 0.9x0.4x0.22 inches (22.9x10.16x5.6 hours grams ON/OFF Control, Negative Logic Remote On/Off Open Circuit Logic (Module Logic High (Module Off) ON/OFF Current (for both remote on/off logic) Leakage Current (for both remote on/off logic) Turn-On Delay Rise Time Turn-On Delay Time, From On/Off Control Turn-On Delay Time, From Input Output Voltage Rise Time Over Temperature Protection Ion/off Von/off =0.0V Logic High, Von/off=14V Von/off 10%Vo,set Vin,min. 10%Vo,set 10%Vo,set 90%Vo,set GENERAL SPECIFICATIONS MTBF Weight Dimensions VPOL5A-12-SIP packages Io=100%of Io.max;Ta=2 MIL-HDBK217F 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter Main Features Functions Operating Temperature Range V-Infinity's VPOL5A-12-SIP series converters highly efficient converter design resulted ability operate over wide ambient temperature environment -40° 85°C). consideration must given de-rating curves when ascertaining maximum power that drawn from converter. maximum power drawn influenced number factors, such Input voltage range. velocity (forced natural convection). Mounting orientation converter with respect Airflow. Motherboard design, especially ground power planes. These effective heat sinks converter. Safe Operating Area (SOA) Figure provides graphical representation Safe Operating Area (SOA) converter. This representation assumes ambient operating conditions such airflow thermal guidelines provided Sections 7.3. Vo,nom VOLTAGE Output load current. Safe Operating Area Over-Temperature Protection (OTP) VPOL5A-12-SIP Series converters equipped with non-latching over-temperature protection. mperature sensor monitors temperature spot (typically, switch). temperature exceeds threshold 120°C (typical) converter will shut down, disabling output. When temperature decreased converter will automatically restart. over-temperature condition induced variety reasons such external overload condition system failure. Io,max Io,CL CURRENT Figure Maximum Output Current Safe Operating Area Over Current Protection different voltage models have full continuous short-circuit protection. unit will auto recover once short circuit removed. provide otection fault condition, unit equipped with internal over-current protection. unit operates normally once fault condition removed. power module will supply 150% rated current. event over current converter will into hiccup mode protection. Output Voltage Adjustment Section describes detail trim output voltage with respect point. output voltage models trimmable range 0.75 5.0Vdc. Remote ON/OFF remote ON/OFF input feature converter allows external circuitry turn converter OFF. Active-high remote ON/OFF available standard. VPOL5A-12-SIP series converters turned remote ON/OFF high, left open floating. Setting will turn converter `Off'. signal level remote on/off input defined with respect ground. using remote on/off pin, leave open (module will on). part number suffix Negative remote ON/OFF version. unit guaranteed over full temperature range this voltage level exceeds 2.8Vdc. converters turned on/off input left open. recommended VPOL5A-12-SIP remote on/off drive circuit shown figure 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter +Vin Remote ON/OFF Applications Layout Design Challenges. optimizing thermal design utilized heat sink. Also some heat transferred from VPOL5A-12-SIP module main board through connecting pins. system designer user must ensure that other components metal vicinity VPOL5A-12-SIP series meet spacing requirements which system approved. resistance inductance layout traces norm should used where possible. consideration must also given proper impedance tracks between power module, input output grounds. recommended VPOL5A-12-SIP footprint shown figure ON/OFF Control VPOL5A-12-SIP Common Common Figure Positive Remote ON/OFF Input Drive Circuit +Vin VPOL5A-12-SIP ON/OFF Control Remote ON/OFF Common Common 1.1mm PLATED OUGH HOLE 1.6mm SIZE 0.20(5.1) LAYOUT TTERN VIEW 0.24(6.1) Figure Negative Remote ON/OFF Input Drive Circuit Dimmension Inches(mm) erance .XX= ±0.02 ±0.5 .XXX= ±0.010 ±0.25 UVLO (Under-Voltage Lockout) voltage determines start operation Converter. When input rises exceeds about 8.0V converter initiates soft start. UVLO function converter hysteresis (about 100mV) built provide noise immunity start-up. Figure Recommended VPOL5A-12-SIP Footprint Safety Input Fusing Safety Considerations. Agency Approvals: power Supply shall submitted receive formal approval from following test agencies. 1.The power supply shall approved nationally recognized testing laboratory UL/CSA 60950 Edition (North America) EN60950 (International) Certificate from internationally recognized test house accordance with 60950. VPOL5A-12-SIP series converters have internal fuse. However, achieve maximum safety system protection, always input line fuse. safety agencies require time-delay fuse with maximum rating 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter Convection Requirements Cooling predict proximate cooling needed module, refer Power De-rating curves Figures These de-rating curves approximations ambient temperatures airflows required keep power module temperature below maximum rating. Once module assembled actual system, module's temperature should checked shown Figure ensure does exceed 110°C. Proper cooling verified measuring power module's temperature Q1-pin shown Figure Tunnel Bakelite 25.4(1.0) Figure Temperature Measurement Location VPOL5A-12-SIP Power Module Thermal Considerations power module operates variety thermal environments; however, sufficient cooling should provided help ensure reliable operation unit. Heat removed conduction, convection, radiation surrounding environment. thermal data presented based measurements taken set-up shown Figure Figures represent test data. Note that airflow parallel long axis module shown Figure VPOL5A-12- 76.2(3.0) Thermocuple Location measuring ambient temperature airflow 12.7(0.5) SIP. temperature either location should exceed output power module should exceed rated power module (VO, max). SMT05 thermal data presented based measurements taken wind tunnel. test setup shown Figure need solder 33mm 40.38mm(1.300'' 1.59'') test pcb. Note that airflow parallel long axis module shown flow Note Dimensions millimeters (inches) Figure Thermal Test Setup 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter TYPICAL POWER DERATING Vout Output Current(A) Ambient Temperature( 0LFM 100LFM 200LFM Figure Typical Power De-rating 3.3Vout NOTE: specific input output derating curves available, please contact V-Infinity detail 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter VPOL5A-12-SIP Vo=1.8V (Eff 100% 100% VPOL5A-12-SIP Vo=1.5V (Eff Efficincy Efficincy 8.3V 8.3V Current Load Current Load VPOL5A-12-SIP Vo=1.2V (Eff 100% VPOL5A-12-SIP Vo=0.75V (Eff Efficincy Efficincy 8.3V 8.3V Current Load Current Load 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter Where: Input Capacitance Power Module VPOL5A-12-SIP converters must connected source impedance. avoid probl with loop stability source inductance should low. Also, input capacitors should placed close converter input pins de-couple distribution inductance. However, external input capacitors chosen suitable ripple handling capability. polymers good choice. They have high capacitance, high ripple rating (typical <100mohm). Electrolytic capacitors should avoided. Circuit shown Figure represents typical measurement methods ripple current. Input reflected-ripple current measured with simulated source Inductance 1uH. Current measured input module. Power Supply output voltage full load output voltage load value line regulation defined Line.reg 100% Where: output voltage maximum input voltage full load. output voltage minimum input voltage full load. Current Meter +Vin +Sense 47uF 10UF VPOL5A-12-SIP Common Common Load CERAMIC Oscilloscope Power Supply 2*100uF Tantalum 220uF ESR<0.1ohm Common Figure Input Reflected-Ripple Test Setup Voltage Meter Figure VPOL5A-12-SIP Test Setup +Vin VPOL5A-12-SIP Test Set-Up basic test set-up measure parameters such efficiency load regulation shown Figure Things note that this converter non-isolated, such input output share common ground. These grounds should connected together impedance ground plane application circuit. When testing converter bench set-up, ensure that -Vin connected together impedance short ensure proper efficiency load regulation measurements being made. When testing V-Infinity's VPOL5A-12-SIP under transient conditions please ensure that transient response source sufficient power equipment under test. calculate Efficiency Load regulation line regulation. value efficiency defined Where: 100% output voltage, output current, input voltage, input current. value load regulation defined Load .reg 100% 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter VPOL5A-12-SIP Output Voltage Adustment. output Voltage VPOL5A-12-SIP adjusted range 0.75V 5.0V connecting single resistor motherboard (shown trim) Figure When Trim resistor connected output voltage defaults 0.75V Output Ripple Noise Measurement test set-up noise ripple measurements shown Figure coaxial cable with 50ohm termination used prevent impedance mismatch reflections disturbing noise readings higher frequencies. +Vin +Vin Trim R-Load VPOL5A-12-SIP Common Common 10uF Tant. Ceramic R-Load Test Jack VPOL5A-12-SIP trim-up Common Common Figure Output Voltage Ripple Noise Measurement Set-Up Figure Trim-up Voltage Setup value Rtrim-up defined 7.10 Output Capacitance V-Infinity's VPOL5A-12-SIP converters provide unconditional stability with without external capacitors. good transient response output capacitors should located close point load. high current applications point already been made layout considerations resistance inductance tracks. Output capacitors with associated values have impact loop stability bandwidth. V-Infinity's converters designed work with load capacitance up-to 3,000uF. reco mmended that additional capacitance, Maximum 3,000uF ESR, connected close point load outside remote compensation point. Rtrim Where: 10500 1000 0.75 Rtrim-up external resistor ohm, desired output voltage give mple above calculation, voltage 3.3Vdc, Rtrim given Rtrim Rtrim 3118 10500 1000 0.75 various output values various resistors calculated provided Table nvenience. Vo,set 0.75 Rtrim (Kohm) Open 22.33 13.00 9.00 7.40 5.00 3.12 1.47 Table Trim Resistor Values 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL5A-12-SIP DESCRIPTION: point load converter Mechanical Outline Diagrams VPOL5A-12-SIP Mechanical Outline Diagrams Dimensions millimeters inches Tolerance: x.xx ±0.02 (0.5mm) x.xxx ±0.010 (0.25 unless otherwise noted SIZE VPOL5A-12-SIP 0.90(22.9) 0.22(5.6)Max. CONNECTION FUNCTION +Output Trim Common Input On/Off 0.14(3.6) 0.400(10.16) 0.025(0.64) 0.025(0.64) 0.19(4.7) 0.100(2.54) 0.200(5.08) 0.700(17.78) 0.800(20.32) Figure VPOL5A-12-SIP Mechanical Outline Diagram 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 Other recent searchesSN74LVC00A - SN74LVC00A SN74LVC00A Datasheet SN54LVC00A - SN54LVC00A SN54LVC00A Datasheet GLT6100L08 - GLT6100L08 GLT6100L08 Datasheet EDS2532CABJ - EDS2532CABJ EDS2532CABJ Datasheet DDS-315-023 - DDS-315-023 DDS-315-023 Datasheet bq2011 - bq2011 bq2011 Datasheet BHP4417FS - BHP4417FS BHP4417FS Datasheet 2N5784 - 2N5784 2N5784 Datasheet 2N5785 - 2N5785 2N5785 Datasheet 2N5786 - 2N5786 2N5786 Datasheet 2N5859 - 2N5859 2N5859 Datasheet 2N5861 - 2N5861 2N5861 Datasheet 2N6190 - 2N6190 2N6190 Datasheet 2N6191 - 2N6191 2N6191 Datasheet 2N6192 - 2N6192 2N6192 Datasheet 2N6193 - 2N6193 2N6193 Datasheet
Privacy Policy | Disclaimer |