| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter
Top Searches for this datasheetPART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter features industry standard high efficiency switching frequency 3.0-5.5 input range 0.9-3.63 wide output range over temperature protection continuous short circuit protection remote on/off cost-efficient open frame design UL/C-UL60950 (E222736) certified INTRODUCTION VPOL15A-5-SMT CONVERTER FEATURES GENERAL DESCRIPTION Electrical Description Thermal Packaging Physical Design. APPLICATIONS Layout Design Challenges. Convection Requirements Cooling Thermal Considerations Power De-Rating Curves Efficiency Load Curves Input Capacitance Power Module Test Set-Up Remote Sense Compensation VPOL15A-5-SMT Series Output Voltage Adustment. 7.10 Output Ripple Noise Measurement 7.11 Output Capacitance 7.12 VPOL15A-5-SMT Reflow Profile TECHNICAL SPECIFICATIONS MAIN FEATURES FUNCTIONS Operating Temperature Range Over-Temperature Protection (OTP) Output Voltage Adjustment Safe Operating Area (SOA) Over Current Protection Remote on/off UVLO (Under-Voltage Lockout) MECHANICAL OUTLINE DIAGRAMS VPOL15A-5-SMT Mechanical Outline Diagrams VPOL15A-5-SMT Tape Reel Dimensions SAFETY Input Fusing Safety Considerations. 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter Introduction This application note describes features functions V-Infinity's VPOL15A-5-SMT series non-isolated dc-dc converters. These highly efficient, reliable compact, high power density, single output dc-dc converters. These "Point Load" modules serve needs specifically fixed mobile telecommunications computing market, employing economical distributed power architectures. VPOL15A-5-SMT series provide precisely regulated output voltage range from 0.9V 3.63Vdc over wide range input voltage (Vi=3.0 5.5Vdc) operate over ambient temperature range -40°C +85°C. Ultr a-high efficiency operation achieved through synchronous rectification drive control techniques. modules fully protected against short circuit overtemperature conditions. V-Infinity's world class automated manufacturing methods, together with extensive testing qualification program, ensure that VPOL15A-5-SMT series converters extremely reliable. converter also protected against over-temperature conditions. converter overloaded ambient temperature gets high, converter will shut down protect unit. +VIN sense +SENSE ON/OFF trim TRIM Figure Electrical Block Diagram VPOL15A-5-SMT Converter Features High efficiency topology, typically 3.3Vdc Industry standard footprint Wide ambient temperature range, -40°C +85°C Cost efficient open frame design Programmable output voltage external resistor from 3.63Vdc minimum load requirement (Stable loads) Remote on/off Remote sense compensation Fixed switching frequency Continuous short-circuit protection over current protection Over-temperature protection (OTP) Monotonic Startup with pre-bias output. UL/IEC/EN60950 Certified. Thermal Packaging Physical Design. VPOL15A-5-SMT series uses multi-layer construction. surface mount power components placed side PCB, low-power control components placed other side. Thus, heat dissipation power components optimized, ensuring that control components thermally stressed. converter open-frame product case case pin. open-frame design several advantages over encapsulated closed devices. Among these advantages are: Efficient Thermal Management: heat removed from heat generating components without heating more sensitive, small signal control components. Environmental: Lead free open-frame converters more easily re-cycled. Cost Efficient: encapsulation. Cost efficient open-frame construction. Reliable: Efficient cooling provided open frame construction offers high reliability easy diagnostics. General Description Electrical Description block diagram VPOL15A-5-SMT Series converter shown Figure Extremely high efficiency power conversion achieved through synchronous rectification drive techniques. Essentially, powerful VPOL15A-5-SMT series topology based non-isolated synchronous buck converter. control loop optimized unconditional stability, fast transient response very tight line load regulation. typical pre-bias application VPOL15A-5-SMT series converters draw reverse current start-up. output voltage adjusted from 3.63vdc, using TRIM with external resistor. converter shut down remote on/off input that referenced ground. This input compatible with popular logic devices; 'positive' logic input supplied standard. Positive logic implies that converter enabled remote on/off input high floating), disabled low. 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter Technical Specifications (All specifications typical nominal input, full load 25°C unless otherwise noted.) PARAMETER ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Operating Temp erature Thermal Considerations Section Storage Temperature NOTES CONDITIONS Device Min. Typical Max. Units +125 INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Hysteresis Voltage Maximum Input Current Vin=3.0 5.5Vdc Io=Io,max. Vo=1.0V Vo=1.2V Vo=1.5V Vo=1.8V Vo=2.0V Vo=2.5V Vo=3.3V Shutdown input idle current Vo=2.7V Vo=3.0V 15.5 No-Load Input Current Converter Input Current Inrush Current Input Reflected-Ripple Current thru inductor, 20MHz OUTPUT CHARACTERISTIC Output Voltage Point Output Voltage Trim Adjustment Range Output Voltage Regulation Load Regulation Line Regulation Tempera ture Coefficient Output Voltage Ripple Noise Peak-to-Peak External Capacitive Load Operating Output Current Range Output Current-Limit Inception Shout Circuit Protection Output Voltage =90% Nominal Output Voltage Continuous with Hiccup Mode Io=Io.min Io.max Vin=low line high line Ta=-40°C 85°C 20MHz bandwidth Full Load, ceramic 10uF tantalum Full Load, ceramic 10uF tantalum 10000 VPOL15A-5SMT -0.5 -0.2 -0.4 +0.5 +0.2 +0.4 ±0.03 %/°C Vin=Nominal Io=Io.max, Tc=25°C Selected external resistor -1.5% Vo,set +1.5% 3.63 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter PARAMETER DYNAMIC CHARACTERISTICS Output Voltage Transient Response Error Brand Setting Time (within Vout nominal) NOTES CONDITIONS Device Min. Typical Max. Units Step Load Change, di/dt=0.1A/us Step Load Change, di/dt=0.1A/us EFFICIENCY Vo=1.0V Vo=1.2V Vo=1.5V Vo=1.8V Vo=2.0V Vo=2.5V Vo=3.3V Non-isolation 100% Load ISOLATION CHARACTERISTICS Input Output FEATURE CHARACTERISTICS Switching Frequency on/off Control, Positive Logic Remote On/Off Logic (Module Off) Logic High (Module on/off Control, Negative Logic Remote On/Off Logic (Module Logic High (Module Off) on/off Current (for both remote on/off logic) Leakage Current (for both remote on/off logic) Turn-On Delay Rise Time Turn-On Delay Time, From On/Off Control Turn-On Delay Time, From Input Output Voltage Rise Time Over Temperature Protection Open Circuit Open Circuit Ion/off Von/off=0.0V Logic High, Von/off=5V Von/off 10%Vo,set Vin,min. 10%Vo,set 10%Vo,set 90%Vo,set hours grams GENERAL SPECIFICATIONS MTBF Weight Io=100%of Io.max;Ta=25 MIL-HDBK-217F 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter current protection. unit operates normally once fault condition Main Features Functions Operating Temperature Range V-Infinity's VPOL15A-5-SMT series converters highly efficient converter design resulted ability operate over wide ambient temperature environment -40° 85°C). consideration must given de-rating curves when ascertaining maximum power that drawn from converter. maximum power drawn influenced number factors, such Input voltage range. Output load current. velocity (forced natural convection). Mounting orientation converter with respect airflow. Motherboard design, especially ground power planes. These effective heat sinks converter. removed. power module will supply 150% rated current. event over current converter will into hiccup mode protection. Remote On/Off remote on/off input feature converter allows external circuitry turn converter off. Active-high remote on/off available standard. VPOL15A-5-SMT series converters turned remote on/off high, left open floating. Setting will turn converter `Off'. signal level remote on/off input defined with respect ground. using remote on/off pin, leave open (module will on). part number suffix negative remote on/off version. unit guaranteed over full temperature range this voltage level exceeds 2.8Vdc. converters turned on/off input left open. recommended VPOL15A-5SMT remote on/off drive circuit shown figures Over-Temperature Protection (OTP) VPOL15A-5-SMT series converters equipped with non-latching over-temperature protection. mperature sensor monitors temperature spot (typically, switch). temperature exceeds threshold 120°C (typical) converter will shut down, disabling output. When temperature decreased converter will automatically restart. over-temperature condition induced variety reasons such external overload condition system failure. Output Voltage Adjustment Section describes detail trim output voltage with respect point. output voltage models trimmable range 3.63Vdc. Safe Operating Area (SOA) Figure provides graphical representation safe operating area (SOA) converter. This representation assumes ambient operating conditions such airflow thermal guidelines provided Sections 7.3. Vo,nom VOLTAGE Safe Operating Area Io,max Io,CL CURRENT Figure Maximum Output Current Safe Operating Area Over Current Protection different voltage models have full continuous short-circuit protection. unit will auto recover once short circuit removed. provide protection fault condition, unit equipped with internal over- 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter +Vin Remote ON/OFF Applications Layout Design Challenges. optimizing thermal design utilized heat sink. Also some heat transferred from VPOL15A-5-SMT module main board through connecting pins. system designer user must ensure that other components metal vicinity VPOL15A-5-SMT series meet spacing requirements which system approved. resistance inductance layout traces norm should used where possible. consideration must also given proper impedance tracks between power module, input output grounds. recommended VPOL15A-5-SMT footprint shown figure ON/OFF Control VPOL15A-5-SMT Common Common Figure Positive Remote on/off Input Drive Circuit +Vin VPOL15A-5-SMT ON/OFF Control Remote ON/OFF Common Common Recommended Layout Dimensions millimetes and(inches) Figure Negative Remote on/off Input Drive Circuit 7.54 (0.297) 4.83 4.83 4.83 7.87 (0.310) UVLO (Under-Voltage Lockout) voltage determines start operation Converter. When input rises exceeds about 2.8V converter initiates soft start. UVLO function converter hysteresis (about 100mV) built provide noise immunity start-up. 10.29 (0.405) (0.190) (0.190) (0.190) +SENSE TRIM 10.92 (0.430) +VIN View Board ON/OFF Safety Input Fusing Safety Considerations. Agency Approvals: power supply shall submitted receive formal approval from following test agencies. 1.The power supply shall approved nationally recognized testing laboratory UL/CSA 60950 Edition (North America) EN60950 (International) Certificate from internationally recognized test house accordance with 60950. VPOL15A-5-SMT series converters have internal fuse. However, achieve maximum safety system protection, always input line fuse. safety agencies require time-delay fuse with maximum rating 20A. 0.64 (0.025) 29.90 (1.177) SIZE MIN:3.556x2.413(0.140x0.095) MAX:4.19x2.79(0.165x0.110) Figure Recommended VPOL15A-5-SMT Footprint 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter TYPICAL POWER DERATING Vout SMT15-05S33A Derating Curve Output Current(A) Ambient Temperature( 0LFM 100LFM 200LFM NOTE: specific input output derating curves available, please contact V-Infinity detail 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter Efficiency Load Curves (Fig. VPOL15A-5-SMT Vo=3.3V (Eff 100% 100% VPOL15A-5-SMT Vo=2.5V (Eff Efficincy Efficincy 4.5V 5.0V 5.5V 3.0V 5.0V 5.5V Current Load VPOL15A-5-SMT Vo=1.8V (Eff 100% Current Load VPOL15A-5-SMT Vo=1.5V (Eff 100% Efficincy Efficincy 3.0V 5.0V 5.5V 3.0V 5.0V 5.5V Current Load Current Load VPOL15A-5-SMT Vo=1.2V (Eff 100% 100% VPOL15A-5-SMT Vo=1.0V (Eff Efficincy Efficincy 3.0V 5.0V 5.5V 3.0V 5.0V 5.5V Current Load Current Load 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter output voltage load Input Capacitance Power Module VPOL15A-5-SMT converters must connected source impedance. avoid probl with loop stability source inductance should low. Also, input capacitors should placed close converter input pins de-couple distribution inductance. However, external input capacitors chosen suitable ripple handling capability. polymers good choice. They have high capacitance, high ripple rating (typical <20mohm). Electrolytic capacitors should avoided. Circuit shown Figure represents typical measurement methods ripple current. Input reflected-ripple current measured with simulated source Inductance 1uH. Current measured input module. Supply Power Voltage 100uF Meter Tant. value line regulation defined Line.reg 100% Current Meter +Vin +Sense Voltage Meter R-Load Where: output voltage maximum input voltage full load. output voltage minimum input voltage full load. Current Meter VPOL15A-5-SMT Oscilloscope Power Supply 2*100uF Tantalum 220uF ESR<0.1ohm Common Figure Input Reflected-Ripple Test Setup +Vin Common Common Figure VPOL15A-5-SMT Series Test Setup Remote Sense Compensation Remote sense regulates output voltage point load. minimizes effects distribution losses such drops across connecting tracks (see Figure 13). Please note however, maximum drop from output point load should exceed 500mV remote compensation work. amount power delivered module defined output voltage multiplied output current IO). When using "Trim Up", output voltage module will increase which, same output current maintained, increases power output module. Make sure that maximum output power module remains below maximum rated power. When remote sense feature being used, leave sense disconnected. VPOL15A-5-SMT Test Set-Up basic test set-up measure parameters such efficiency load regulation shown Figure Things note that this converter non-isolated, such input output share common ground. These grounds should connected together impedance ground plane application circuit. When testing converter bench set-up, ensure that -Vin connected together impedance short ensure proper efficiency load regulation measurements being made. When testing V-Infinity's VPOL15A-5-SMT series under transient conditions please ensure that transient response source sufficient power equipment under test. calculate Efficiency Load regulation line regulation. value efficiency defined Figure Circuit Configuration Remote Sense Operation Distribution Losses +Vin +Sense VPOL15A-5-SMT R-Load Where: 100% output voltage, output current, input voltage, input current. Common Common Distribution Losses value load regulation defined Load .reg Where: 100% output voltage full load 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter VPOL15A-5-SMT Series Output Voltage Adustment. output voltage VPOL15A-5-SMT adjusted range 0.9V 3.63V connecting single resistor motherboard (shown Rtrim) Figure When trim resistor connected output voltage defaults 0.75V 7.10 Output Ripple Noise Measurement test set-up noise ripple measurements shown Figure coaxial cable with 50ohm termination used prevent impedance mismatch reflections disturbing noise readings higher frequencies. +Vin Trim +Vin VPOL15A-5-SMT R-Load trim-up VPOL15A-5-SMT 10uF Tant. Ceramic R-Load Test Jack Common Common Common Common Figure Output Voltage Ripple Noise Measurement Set-Up Figure Trim-up Voltage Setup value Rtrim-up defined 7.11 Output Capacitance V-Infinity's VPOL15A-5-SMT series converters provide unconditional stability with without external capacitors. good transient response output capacitors should located close point load. high current applications point already been made layout considerations resistance inductance tracks. Output capacitors with associated values have impact loop stability bandwidth. V-Infinity's converters designed work with load capacitance up-to 10,000uF. ommended that additional capacitance, typically 1,000uF (<20mohm), connected close point load outside remote compensation point. Rtrim Where: 21070 5110 0.75 Rtrim-up external resistor ohm, desired output voltage give mple above calculation, voltage 3.3Vdc, Rtrim given 21070 Rtrim 5110 0.75 Rtrim 3153 various output values various resistors calculated provided Table nvenience. 7.12 VPOL15A-5-SMT Reflow Profile example VPOL15A-5-SMT reflow profile given Figure Equipment used: REFLOW HD-350SAR Alloy: AMQ-M293TA C-SMQ92 IND-82088 SN63 REFLOW PROFILE Vo,set 0.90 1.00 1.20 1.50 1.80 2.00 2.50 3.30 3.63 Rtrim (Kohm) 135.36 79.17 41.71 22.98 14.96 11.75 6.93 3.15 2.20 TEMPERATURE TIME (SECONDS) Table Trim Resistor Values Figure VPOL15A-5-SMT Reflow Profile 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 rev. page date PART NUMBER: VPOL15A-5-SMT DESCRIPTION: point load converter Mechanical Outline Diagrams VPOL15A-5-SMT Mechanical Outline Diagrams Dimensions millimeters inches Tolerance: x.xx ±0.02 (0.5mm) x.xxx ±0.010 (0.25 unless otherwise noted VPOL15A-5-SMT Tape Reel Dimensions tape reel dimensions VPOL15A-5-SMT module shown Figure BOTTOM VIEW BOARD 33.0 (1.30) 7.87 (0.310) 4.83 4.83 4.83 7.54 (0.297) 1.65 (0.065) 9.30 (0.366) max. (0.190) (0.190) (0.190) TRIM +SENSE 10.29 13.46 (0.405) (0.530) 1.60 (0.063) +VIN ON/OFF SURFACE MOUNT CONTACT 1.91 (0.075) 1.22 (0.048) INDUCTOR 2.84 (0.112) Dimensions millimeters(Inches) lerances :X.X ±0.5mm(0.02in),X.XX ±0.25mm(0.010in),unless otherwise noted. Figure VPOL15A-5-SMT Mechanical Outline Diagram Figure VPOL15A-5-SMT Tape Reel Dimensions 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 Other recent searchesVND600SP - VND600SP VND600SP Datasheet TRR-8B43-001 - TRR-8B43-001 TRR-8B43-001 Datasheet SM0259 - SM0259 SM0259 Datasheet SM0265 - SM0265 SM0265 Datasheet SLA3001M - SLA3001M SLA3001M Datasheet SLA3002M - SLA3002M SLA3002M Datasheet HV-100 - HV-100 HV-100 Datasheet 1N5333B - 1N5333B 1N5333B Datasheet
Privacy Policy | Disclaimer |