| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter
Top Searches for this datasheet04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter description VHK50W series rugged DC-DC converters designed high reliability applications, featuring integral heat sink, over-temperature protection, over-current protection input transient voltage protection. With external input fuse, converter protect accidental input polarity reversal. wide input range (9-36V 1875V) very useful stabilize input source like batteries various discharging charging conditions. Additionally, high efficiency, fast response, tight regulations, remote sense remote On/Off control make these converters very useful many industrial communications applications. features isolated output Compliant input range output short circuit protection enclosure with integrated heatsink design shutdown MODEL VHK50W-Q24-S3R3 VHK50W-Q24-S5 VHK50W-Q24-S12 VHK50W-Q24-S15 VHK50W-Q24-S24 VHK50W-Q48-S3R3 VHK50W-Q48-S5 VHK50W-Q48-S12 VHK50W-Q48-S15 VHK50W-Q48-S24 notes: input voltage nominal range output voltage output current input current load full load (mA) (mA) efficiency typ. 9.0~36.0 9.0~36.0 9.0~36.0 9.0~36.0 9.0~36.0 18.0~75.0 18.0~75.0 18.0~75.0 18.0~75.0 18.0~75.0 4.16 3.33 2.08 4.16 3.33 2.08 1785 2570 2510 2510 2510 1270 1240 1240 1240 output derating curve (page INPUT parameter input voltage range under voltage lockout conditions/description units remote on/off control input filter notes: power power down power power down section application notes type suffix model number negative logic on/off control *V-Infinity reserves right make changes products discontinue product service without notice, advise customers verify most up-todate product information before placing orders. V-Infinity assumes liability responsibility customer's applications using V-Infinity products other than repair replacing V-I's option) V-Infinity products meeting V-I's published specifications. Nothing will covered outside standard product warranty. 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 page date 04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter OUTPUT parameter voltage accuracy transient response external trim adj. range ripple noise (20MHz conditions/description step load change 3.3V, 12V& temperature coefficient short circuit protection continuous line regulation load regulation over voltage protection trip range, nom. over current protection nominal output ±0.03 ±0.2 ±0.2 units pk-pk pk-pk pk-pk %/°C GENERAL SPECIFICATIONS parameter switching frequency operating ambient temp. storage temperature thermal shutdown case temp. case material conditions/description aluminum steel units ISOLATION SPECIFICATIONS parameter isolation voltage conditions/description input/output input/case output/case 1500 1500 1500 units isolation resistance notes: measured from high line line full load measured from full load zero load nominal input output derating curve (page *V-Infinity reserves right make changes products discontinue product service without notice, advise customers verify most up-todate product information before placing orders. V-Infinity assumes liability responsibility customer's applications using V-Infinity products other than repair replacing V-I's option) V-Infinity products meeting V-I's published specifications. Nothing will covered outside standard product warranty. 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 REV. DESCRIPTION DRAWING DATE 4/22/2008 86.3 3.398 108.0 4.252 38.00 1.496 16.0 0.630 (TYP) 101.76 4.006 91.0 3.583 PLCS) 0.382 (TYP) 19.0 0.748 70.0 2.756 TOLERANCE: ±0.3mm UNLESS OTHERWISE SPECIFIED 26.18 1.031 0.380 (TYP) Terminal Description Trim Case Remote 20050 112th Ave. Tualatin, 97062 Phone: 503-612-2300 800-275-4899 Fax: 503-612-2383 Website: www.cui.com TITLE: RoHS VHKXXW Series APPROVED UNITS: REV: PART [INCHES] SCALE: FILE NAME: DRAWN VHKXXW Series COPYRIGHT 2008 INC. Material Aluminum/Steel page date 04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter APPLICATION NOTES OUTPUT DE-RATING operating ambient temperature range VHK50W +85°C, with actual output power subject following de-rating curves free-air convection forced conditions. ensure long-term reliability, important ensure proper cooling worst operating conditions. VHK50W Power Derating Curves 115% Natural Convection 100% (100LFM) Relative Output Power nominal output (200LFM) (300LFM) (400LFM) (500LFM) (600LFM) (700LFM) Ambient Temperature degrees FIGURE OUTPUT DERATING INPUT VOLTAGE RANGE important ensure input voltage measured converter input pins within range that converter. Make sure wire losses voltage ripples accounted for. possible problem driving converter with linear unregulated power supply. example, average voltage measured with voltage ripple 3Vpp, actual input swing from 7.5V 10.5V. This will outside specified input range 9-36V converter function properly. other end, make sure actual input voltage does exceed highest voltage or75V. LEAD WIRES Make sure input output wires adequate size minimize voltage drop, ensure voltage across input terminals above converter's rated minimum voltage times. recommended have wire pairs twisted, respectively input pair output pair, minimize noise pickup. 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 page date 04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter INPUT CURRENT input voltage source must able provide enough current converter, otherwise start operate properly. typical symptom starting unusually output voltage. general, recommended able provide least: Ipeak 150%*Pout/( *Vmin) where Pout maximum output power, Vmin minimum input voltage converter's efficiency. example, VHK50W-Q24-S5 operate with 9~36V input, output efficiency 81%, minimum source current recommended Ipeak 150% (81% 10.29A. INPUT FUSE limit input current facilitate input reversal protection input protection, fast-acting input fuse recommended input line. fuse rating will depend input range should allow maximum current lowest input volt age, shown this equation: Ipeak 150%*Pout/( *Vmin). previous example VHK50W-Q24-S5, peak input current calculated 10.29A. fuse suitable this application. Make sure fuse voltage rating higher than maximum input voltage. INPUT important ensure input voltage does exceed maximum rated input voltage that model. suppress voltage transients short durations, converter includes transient voltage suppression device (TVS) input. built-in rated breakdown voltage VHK50W-Q24-XX models VHK50W-Q48 models. With small transients short-durations, will limit input voltage without interrupting converters operations. large transients, conduct large amount current that trip input fuse. Without input fuse, converter suffer permanent damages. When fuse open, replace with same type ratings. INPUT REVERSAL PROTECTION input voltage reversed reason, built-in protection circuits converter will limit reverse voltage diode drop which more than With external input fuse connected, fuse will open thus remove power from converter. Check wiring make corrections needed. input fuse will need replaced. Make sure fuse same type rating. Without input fuse, converter suffer permanent damages. REMOTE SENSE converter provides regulated outputs output terminals. When there large current and/or output cable some length, voltage output cable noticeably lower than terminals. converter compensate 0.5V voltage drop through remote sense terminals. ensure accurate regulation, separate wires (twisted) from desired regulation points remote sense terminals, shown below. Trim FIGURE REMOTE SENSE Load 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 page date 04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter OUTPUT TRIMMING (OPTIONAL) output voltages preset nominal values indicated models table factory. desired, output voltage optionally trimmed different value (+/- 10%) with external resistors and/or potentiometer shown below. +Vin FIGURE TRIMMING WITH EXTERNAL POTENTIOMETER Trim Trimpot load -Vin trim output voltage with fixed resistors, output voltage calculated follows. Trim-Up +Vin Trim trim-up load Trim-Down +Vin trim-down Trim -Vin load -Vin FIGURE TRIM-UP VOLTAGE SETUP value trim-up defined FIGURE TRIM-DOWN VOLTAGE SETUP value trim-down defined Where: trim-up external resistor o,nom nominal output voltage. desired output voltage. internal unit defined Table example, trim-up output voltage 5.0V module (VHK50W-Q48-S5) 5.4V, trim-up calculated follows: Where: trim-down external resistor o,nom nominal output voltage. desired output voltage. internal unit defined Table example, trim-up output voltage 5.0V module (VHK50W-Q48-S5) 4.6V, trim-down calculated follows: Table 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 page date 04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter OUTPUT SHORT-CIRCUIT PROTECTION Output overload short circuit conditional will cause output voltage decline shutdown altogether. case temperature over 85°C, output recovers automatically when short conditions removed. case slight overloading, output voltage shut down, converter build heat over time, causing over-temperature shutdown. OVER-TEMPERATURE PROTECTION When case temperature reaches about 85°C, converter's built-in protection circuit will shut down output. When temperature reduced enough safe operating level, converter will recover normal operations automatically. OUTPUT case output voltage exceeds threshold, converter shuts down. OUTPUT PARALLEL CONNECTIONS converter designed load share output. However, redundancy, outputs more converters connected parallel through O-Ring diodes, shown below. +Vin -Vin FIGURE OUTPUT PARALLEL CONNECTIONS +Vin -Vin OUTPUT SERIES CONNECTIONS more converters connected series obtain higher output voltage. prevent output reverse biasing each other case short, Schottky diode each output reverse polarity, shown diagram. event short, converters will forward-bias diodes output reversal will limited diode drop (about 0.5V) only, damage converters. forward current will cause each converter into short-circuit protection. proper diode selection, make sure that: diodes voltage rating higher than each converter output; rated diode current carry short-circuit current; diodes overheat before short removed. +Vin -Vin FIGURE OUTPUT SERIES CONNECTIONS +Vin -Vin 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 page date 04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter REMOTE OUTPUT ON/OFF CONTROL converter output enabled disabled through On/Off pin. control logic shown this table. common control circuit shown below. (pin High signal here disable output -Vin -Vin (pin FIGURE REMOTE ON/OFF CONTROL WITH TRANSISTOR SWITCH FIGURE REMOTE ON/OFF CONTROL Logic Table Negative logic Closed <0.8 Output Open >2.4 Output ISOLATION Positive logic Output Output input output converter electrically isolated. needed, output terminal connected input terminal, resulting converter non-isolated. INPUT FILTERING INTERFERENCE VHK50W converters have input capacitors that control input current ripple associated interference. However, been tested formal standard conducted emissions. Additional filtering needed ensure compliance standard. Refer FIGURE reference circuit. FIGURE FILTER VHK50W +Vin -Vin CASE VHK50W Series meet class meet class 47µF/50V ESR<0.60 220µF/50V ESR<0.120 47µF/50V ESR<0.60 220µF/50V ESR<0.120 2200pF/2KV 2200pF/2KV Short Short 2.5µH 1.5µH NOTE: recommended components starting point guaranteed meeting these requirements. More less filtering required specific application meet other standards, e.g. MIL-STD-461. 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 page date 04/2008 PART NUMBER: VHK50W DESCRIPTION: chassis mount dc-dc converter OUTPUT FILTERING converter built-in capacitors output control ripple noise. desired, additional output capacitance introduced input powered equipment. Recommended starting point: tantalum ceramic capacitor parallel output. OUTPUT NOISE MEASUREMENT SCHEMATIC proper output ripple noise measurement, connect tantalum ceramic capacitor across output. scope bandwidth 20MHz. Probe directly capacitors, using small ground clip minimize measurement error. +Vin Trim Ceramic 1.0µF Resistor Load -Vin Solid Tantalum 10µF Scope FIGURE OUTPUT NOISE MEASUREMENT CIRCUIT 20050 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 503.612.2382 Other recent searchesR2005200P1 - R2005200P1 R2005200P1 Datasheet R2005200P12 - R2005200P12 R2005200P12 Datasheet MN863584 - MN863584 MN863584 Datasheet LT1425 - LT1425 LT1425 Datasheet KTC2020D - KTC2020D KTC2020D Datasheet HM62W4100HC - HM62W4100HC HM62W4100HC Datasheet B05S - B05S B05S Datasheet B10S - B10S B10S Datasheet
Privacy Policy | Disclaimer |