BU-63705
Make sure next Card purchase has.
MIL-STD-1553 DUAL REDUNDANT REMOTE TERMINAL HYBRID SPACE-RT-II
FEATURES
Drop Replacement BU-65142 Radiation Tolerant Radiation Hardened versions Space Based Applications Complete Integrated Remote Terminal Including: Low-Power Transceivers Complete Protocol Multiple Ordering Options; (Only), +5V/-15V, +5V/-12V Direct Interface Systems with Processor High Reliability Screening
DESCRIPTION
BU-63705, "SPACE-RT-II", Hi-Rel radiation tolerant complete dual redundant MIL-STD-1553 Remote Terminal Unit (RTU). SPACE-RT-II drop Replacement BU-65142. device based upon custom ICs, which includes monolithic bipolar power transceivers RICMOSprotocol chip containing data buffers timing control logic. supports mode codes dual redundant operation, combination which illegalized. Parallel data transfers accomplished with type handshaking, compatible with most types. Data transfers to/from memory simplified latched command word word count outputs. Error detection recovery enhanced BU-63705 special features. 14-bit built-in-test word register stores information, sends Controller response Mode Command Transmit Word. BU-63705 performs continuous on-line wraparound self-test, provides four error flags host CPU. Inputs provided host control bits Status Word. integrated hermetic package, -55°C +125°C operating temperature range, complete operation make BU-63705 ideal MIL-STD-1553 applications requiring hardware microprocessor subsystems.
MORE INFORMATION CONTACT:
Data Device Corporation Wilbur Place Bohemia, York 11716 631-567-5600 Fax: 631-567-7358 www.ddc-web.com
Technical Support: 1-800-DDC-5757 ext. 7771
trademarks property their respective owners. 2005 Data Device Corporation
Data Device Corporation www.ddc-web.com
DATA
ENCODER/ DECODER PROCESSOR BUFFER
TRANSCEIVER
DB0-DB15
WATCHDOG TIMEOUT
TRANSFER CONTROLS
DTREQ DTGRT DTACK DTSTR
DATA
ENCODER/ DECODER PROCESSOR
TRANSCEIVER
CURRENT WORD COUNTER
A0-A4 A5-A10
COMMAND LATCH
ADDRESS PARITY
PROTOCOL SEQUENCER CONTROL LOGIC
STATUS REGISTER
DAT/CMD (ME) ADBC FLAG BUSY FLAG ERROR FLAGS MESS FAIL FAIL RTADD TIMING FLAGS NBGT INCMD BITEN STATEN
CLOCK
CUSTOM CHIP
BU-63705 A-04/05-1M
FIGURE BU-63705 SERIES BLOCK DIAGRAM
TABLE SPACE-RT-II SERIES SPEC'S
PARAMETER ABSOLUTE MAXIMUM RATING Supply Voltage Logic Transceiver -15V (BU-63705X1) -12V (BU-63705X2) Receiver Differential Input Voltage Logic Voltage Input Range RECEIVER Differential Input Impedance (BU-63705 X1/X2) MHz) Differential Input Resistance (BU-63705X3) Input Threshold Level Direct Coupled (BU-63705 X1/X2) Transformer Coupled, Measured Stub (BU-63705X3) CMRR MHz) MHz) TRANSMITTER Differential Output Voltage Direct Coupled Across Measured Transformer Coupled Across Measured Stub Output Noise, Differential (Direct Coupled) Output Offset Voltage, (Transformer Coupled Across ohms) Rise/Fall Time LOGIC (VCC =5.5V) (VCC 4.5V) (VCC 5.5V, VCC) (VCC 5.5V, 0.0V) 16MHz_IN other inputs (VCC 4.5V, max) (VCC 4.5V, max) (VCC 4.5V) (Note (VCC 4.5V) 1MHz) 1MHz) POWER SUPPLY REQUIREMENTS Logic Power Logic Current Drain BU-63705X1 (Ch. -15V (VA, BU-63705X2 (Ch. -12V (VA, BU-63705X3 (+5V Only) (Ch. UNITS
TABLE SPACE-RT-II SERIES SPEC'S (CONT)
PARAMETER POWER SUPPLY REQUIREMENTS (CONTINUED) Current Drain BU-63705X1 -15V (Ch.A Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle BU-63705X2 -12V (Ch.A Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle BU-63705X3 (Ch.A Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle POWER DISSIPATION (NOTE Total Hybrid BU-63705X1 Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle BU-63705X2 Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle BU-63705X3 Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle Hottest BU-63705X1 Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle BU-63705X2 Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle BU-63705X3 Idle Transmitter Duty Cycle Transmitter Duty Cycle 100% Transmitter Duty Cycle UNITS
-0.5 -0.5 -18.0 -18.0
40.0 Vcc+0.5
Vp-p
-0.5
0.28
0.200
1.20 0.860 Vp-p Vp-p
Vp-p Vp-p mVp-p, diff mVp-p, diff nsec
-250 -600
+250
1.475 1.856 2.238 3.000 1.295 1.680 2.065 2.895 0.687 0.92 1.15 1.60
0.680 1.010 1.350 2.030 0.290 0.540 0.790 1.290 0.280 0.510 0.750 1.220
-15.75 -15.0
-14.25
-12.6 -12.0
-11.4
4.75
5.25
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE SPACE-RT-II SERIES SPEC'S (CONT)
PARAMETER CLOCK INPUT Frequency Nominal Value Long Term Tolerance 1553A Compliance 1553B Compliance Short Term Tolerance, 1553A Compliance 1553B Compliance Duty Cycle 1553 MESSAGE TIMING Response Timeout Response Time Transmitter Watchdog Timeout THERMAL Thermal Resistance, Junction-to -Case, Hottest (ThetaJC) Operating Junction Temperature Storage Temperature Lead Temperature (soldering sec.) PHYSICAL CHARACTERISTICS Size 78-pin Ceramic (BU-63705D) UNITS
HIGH-REL SCREENING
committed design manufacture hybrids transformers with enhanced processing screening spaceborne applications other systems requiring highest levels reliability. These platforms include launch vehicles, satellites International Space Station. tailored design methodologies optimize fabrication space level hybrids. intent design guidelines minimize number wirebonds, minimize number substrate layers, maximize space between components. DDC's space grade products combine analog bipolar hard CMOS technology provide various levels radiation tolerance. BU-63705 packaged 78-pin ceramic package. contrast Kovar (metal) packages, ceramic eliminates hermeticity problems associated with glass beads used metal packages. addition, ceramic packages provide more rigid leads, better thermal properties, easier wirebonding, lower weight. production space level hybrids entail enhanced screening steps beyond DDC's standard flow. This includes Condition visual inspection, analysis, element evaluation integrated circuit die. hybrids, additional screening includes Particle Impact Noise Detection (PIND), 320hour burn-in (standard this device), 100% non-destructive wirebond pull (standard this device), X-ray analysis, well Destructive Physical Analysis (DPA) testing, extended temperature cycling testing, moisture content limit 5000 PPM. TABLE summarizes procurement screening, element evaluation, hybrid screening used production BU-63705.
-0.01 -0.10 -0.001 -0.01 0.01 0.10 0.001 0.01
17.5
18.5
19.5
7.55
°C/W
1.80 2.10 0.21 (45.7 53.3 5.3) 1.80 2.10 0.21 (45.7 53.3 5.3) (48.2)
(mm) (mm)
78-pin Ceramic Flat Pack (BU-63705F) Weight Notes (for TABLE
Minus sign indicates direction current flow. Power dissipation specifications assume transformer coupled configuration, with external dissipation (while transmitting) 0.14 watts active isolation transformer, 0.08 watts active coupling transformer, 0.45 watts each isolation resistors, 0.15 watts each termination resistors.
RADIATION TOLERANCE
hybrids inherently immune Latchup. transceiver bipolar/BiCMOS, digital logic implemented Honeywell RICMOSIV Gate Array (HX2000 Series).
TABLE BU-63705 SERIES RADIATION SPECIFICATIONS
PART NUMBER TOTAL DOSE SINGLE EVENT UPSET SINGLE EVENT LATCHUP
BU-63705 X1/X2
300K Rad*
10-8 errors/device-day, (LET Threshold MeV-cm2/mg) 10-8 errors/device-day, (LET Threshold MeV-cm2/mg)
Immune
BU-63705
100K
Immune
Consult factory Version
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE HIGH RELIABILITY SCREENING OPTIONS
ELEMENT EVALUATION Visual Inspection: Integrated Circuits Transistors Diodes Passive Components METHOD MIL-STD-883, Method 2010 Condition MIL-STD-750, Method 2072 2073 MIL-STD-883, Method 2032 Class
Analysis Integrated MIL-STD-883, Method 2018 Circuits Element Evaluation: Visual, Electrical, Wire Bondability, 24-Hour Stabilization Bake,10 Temperature Cycles 5000 constant acceleration MIL-H-38534 240-Hour Powered Burn-In 1000-Hour Life Test (Burn-In 1000-Hour Life Test Only Required Active Components.) ASSEMBLY TEST Particle Impact Noise Detection (PIND) 320-Hour Burn-In (standard this device) 100% Non-Destructive Wirebond Pull (standard this device) Radiographic (X-Ray) Analysis TESTING Extended Temperature Cycling: Cycles Including Radiographic (X-Ray) Testing Moisture Content Limit 5000 MIL-STD-883, Method 2020 Condition MIL-STD-883, Method 1015
BU-63705 allows subsystem host control bits status word. particular interest Illegal Command input which used message error illegalize command word. BU-63705 provides four error flags subsystem host evaluating condition. addition continuous on-line self-test performed BU63705 every transmission. last Transmitted Word every message wrapped around into decoder compared with Actual Word. discrepancy flagged error.
TIMING
Interfacing subsystem host BU-63705 simple compatible with most microprocessors. FIGURES illustrate typical MIL-STD-1553 messages Transmit data Receive data. FIGURES illustrate transfers. each case NBGT identifies start message, INCMD identifies that command being processed. handshake sequence DTREQ, DTGRT, DTACK used transfer each word over parallel data highway. DTSTR RD/WR used control transfers memory. identifies "good block received", when received message passed validation checks correct word count. BUFENA (Buffer Enable) must applied enable internal tri-state buffers.
ERROR FLAGS
MIL-STD-883, Method 2023
Four error flags output subsystem provide information condition BU-63705. (Message Error) line goes following error conditions exist: format error word count error invalid word sync error address error error RTFAIL (Remote Terminal Failure) line goes whenever results continuous wraparound self-test shows discrepancy, transmitter watchdog timeout occurred. HSFAIL (Handshake Failure) line goes whenever system does issue DTGRT response DTREQ before timing-out. RTADR Address Error) line goes whenever address lines parity lines show parity error (the terminal will respond commands while this error condition exists).
MIL-STD-883, Method 2012
MIL-STD-883, Method 1010 Condition MIL-STD-883, Method 2012
MIL-STD-883, Method 1018
INTRODUCTION
BU-63705 complete dual redundant Remote Terminal Unit (RTU). fully compliant with MIL-STD-1553B supports message formats. shown FIGURE includes transceivers custom chip containing encoders decoders, processors, protocol sequencer control logic, output latches, buffers. With addition data transformers, BU-63705 ready connection MIL-STD-1553 data bus. Data transferred from subsystem host over 16bit parallel highway, which isolated bi-directional buffers. transfers made with type handshake sequence request, grant acknowledge. Read/write data strobes provided simplify interfacing external RAM. Also simplifying interface availability latched command word auto-incrementing word counter. These signals used address data directly from RAM. Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
STATUS REGISTER
inputs BU-63705 allow subsystem host control bits status word. Illegal Command input used Message Error Status Word suppress transmission data controller. This line allows illegalization combination commands. latched Command Word connected address pins optional external PROM, which would drive illegal Command line when identifies command programmed illegal.
BUILT-IN-TEST
BU-63705 contains 14-bit Built-In-Test (BIT) word register which stores information about condition RTU. When mode code received transmit word, contents register transmitted over 1553 bus. FIGURE shows fault assigned each word. Conditions monitored are; transmitter timeouts, loop test failures, transmitter shutdown, subsystem handshake failure, results individual message validations.
STATUS REGISTER ASSIGNMENTS
(Subsystem Request) line used Status Word service request bit. ADBC (Accept Dynamic Control) line used Status Word control bit. RTFLAG Flag) Line used Status Word terminal flag bit. BUSY (Busy) line used Status Word busy bit, inhibit subsystem requests data. SSFLAG (SubSystem Flag) line used Status Word subsystem (fault) flag.
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
DIRECT COUPLED (SHORT STUB) 1.4:1
DATA
-15V
BU-63705X1
ISOLATION TRANSFORMER
TRANSFORMER COUPLED (LONG STUB) 1:1.4
0.75 0.75
ISOLATION TRANSFORMER
COUPLING TRANSFORMER
DIRECT COUPLED (SHORT STUB) 1:0.83
-12V
BU-63705X2
ISOLATION TRANSFORMER
TRANSFORMER COUPLED (LONG STUB) 1:0.67 1:1.4
0.75 0.75
ISOLATION TRANSFORMER
COUPLING TRANSFORMER
DIRECT COUPLED (SHORT STUB) 1:2.5
BU-63705X3
11.6
ISOLATION TRANSFORMER
TRANSFORMER COUPLED (LONG STUB) 1:1.79 1:1.4
0.75 0.75
11.6VPP
ISOLATION TRANSFORMER
COUPLING TRANSFORMER
FIGURE INTERFACE 1553
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
TRANSFORMER CONSIDERATIONS BU-63705X3 (+5V ONLY VERSIONS)
selecting isolation transformers used BU-63705 (+5V only) versions, there limitation maximum amount leakage inductance. this limit exceeded, transmitter rise fall times increase, possibly causing amplitude fall below minimum level required MILSTD-1553. addition, excessive leakage imbalance result transformer dynamic offset that exceeds 1553 specifications. maximum allowable leakage inductance measured follows: side transformer that connects Hybrid defined "primary" winding. side primary shorted primary center-tap, inductance should measured
across "secondary" (stub side) winding. This inductance must less than Similarly, other side primary shorted primary center-tap, inductance measured across "secondary" (stub side) winding must also less than difference between these measurements "differential" leakage inductance. This value must less than Beta Transformer Technology Corporation (BTTC), subsidiary DDC, manufactures transformers variety mechanical configurations with required turns ratios 1:2.5 direct coupled, 1:1.79 transformer coupled. Table provides listing many these transformers. further information, contact BTTC 631-244-7393 www.bttc-beta.com.
TABLE BTTC TRANSFORMERS WITH BU-63705X3
TRANSFORMER CONFIGURATION Single epoxy transformer, through-hole, 0.625 0.625, 0.250" height Single epoxy transformer, through-hole, 0.625 0.625, 0.220" height Single epoxy transformer, flat pack, 0.625" 0.625", 0.275" height Single epoxy transformer, surface mount, 0.625" 0.625", 0.275" height Single epoxy transformer, surface mount, hi-temp solder, 0.625" 0.625", 0.220" height Single epoxy transformer, flat pack, 0.625" 0.625", 0.150" height Single epoxy transformer, surface mount, 0.625" 0.625", 0.150" height
Single epoxy transformer, through hole, transformer coupled only, 0.500" 0.350", 0.250" height
BTTC PART B-3067 B-3226 B-3818 B-3231 B-3227 B-3819 LPB-5014 LPB-5015 B-3229 TST-9007 TST-9017 TST-9027 TLP-1205 TLP-1105 TLP-1005 HLP-6014 HLP-6015
Dual epoxy transformer, twin stacked, 0.625" 0.625", 0.280" height Dual epoxy transformer, twin stacked, surface mount, 0.625" 0.625", 0.280" height Dual epoxy transformer, twin stacked, flat pack, 0.625" 0.625", 0.280" height Dual epoxy transformer, side side, through-hole, 0.930" 0.630", 0.155" height Dual epoxy transformer, side side, flat pack, 0.930" 0.630", 0.155" height Dual epoxy transformer, side side, surface mount, 0.930" 0.630", 0.155" height Single metal transformer, hermetically sealed, flat pack, 0.630" 0.630", 0.175" height Single metal transformer, hermetically sealed, surface mount, 0.630" 0.630", 0.175" height
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE ISOLATION TRANSFORMER GUIDE
PART NUMBER TURNS RATIO DIRECT XFORMER COUPLED COUPLED RECOMMENDED XFORMER PLUG-IN SURFACE MOUNT B-2387, B-2343, DESC M21038/27 -12, M21038/27 LPB-5002 LPB-5009 LPB-6002 LPB-6009 LPB-5001 LPB-5008 LPB-6001 LPB-6008
BU-63705X1
1.41:1
BUS-25679, B-2203, DESC M21038/2702
1:0.83
BUS-29854
BU-63705X2 1.25:1 (See Note)
1:0.67
B-2388, DESC B-2204,DESC M21038/27 -13, M21038/27B-2344, DESC M21038/27
BU-63705X3
1:2.5
1:1.79
TABLE
Note:
B-2204, B-2388, B-2344 transformers have slightly different turns ratio direct coupled taps than turns ratio BU-29854 direct-coupled taps. They however, have same transformer coupled ratios. transformer coupled applications, either transformer used. transceiver BU-63705D2, BU-63705F2 designed work with 1:0.83 ratio direct-coupled applications. direct-coupled applications, 1:0.83 turns ratio recommended, 1.25:1 used. 1.25:1 turns ratio will result slightly lower transmitter amplitude (approximately 3.6% lower) slight shift RT's receiver threshold.
DATA SYNC
ALWAYS ZERO
CHANNEL TRANSMITTER TIMEOUT
CHANNEL TRANSMITTER TIMEOUT
HANDSHAKE FAILURE
CHANNEL TRANSMITTER TIMEOUT
CHANNEL LOOP TEST FAILURE
CHANNEL LOOP TEST FAILURE
MODE CODE ERROR CODE ILLEGAL RESERVED MODEWITH MODE CODE ILLEGAL BROADCAST MESSAGE SERVICING ABORTED WORD COUNT
CHANNEL LOOP TEST FAILURE
CHANNEL TRANSMITTER SHUTDOWN
CHANNEL TRANSMITTER SHUTDOWN
MESSAGE SERVICING ABORTED HIGH WORD COUNT
NON-MODE BROADCAST COMMAND TRANSMIT
NOTES
BITS CLEARED BEGINNING EACH MESSAGE UPDATED MESSAGE. THEY ONLY REFLECT PRESENT COMMAND WORD. BITS 10-13 LATCHED ONLY CLEARED MODE RESET COMMAND MASTER RESET (RESET). BITS ONLY MODE COMMAND "TRANSMITTER SHUTDOWN" CLEARED MODE COMMAND "OVERRIDE TRANSMITTER SHUTDOWN" "RESET REMOTE TERMINAL". BITS ALSO CLEARED RESET.
FIGURE BUILT-IN-TEST (BIT) WORD REGISTER
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
1.0µs 1553 1514 1110
TRANSMIT WORDS
STATUS 1514 1110
0.5µs
0.5µs
NBGT 100-150ns INCMD 825-925 200ns DTGRT 250ns DTACK 100-150ns DTSTR A10(T/R BIT) DAT/CMD 450-550ns
PREVIOUS MESSAGE
DTREQ
2.4µs
9.8µs
100-150ns
50ns
200-400ns A9-A5 A4-A0 D15-D0 100ns STATEN
PREVIOUS SUBADDRESS
COMMAND WORD SUBADDRESS FIELD
WORD COUNT
PREVIOUS WORD COUNT
CURRENT WORD COUNT 00000 note
BITEN
FAIL FAIL
100ns
225-275ns 50ns 475-550ns 825-925ns 3.5µs
225-275 50ns 475-550ns INTERNAL DATA BUFFERS INPUTS
5.88µs A10-A0 VALID (COMMAND WORD) DTGRT RECOGNIZED
MORE CONTINUOUS DATA ENCODER STARTED
COMMAND WORD TRANSFER SUBSYSTEM START STATUS INPUTS COMMAND WORD STROBED INITIALIZATION BUSY ILLCMD STROBED SSFLAG A4-A0 0(CURRENT ADBC WORD COUNTER) RTFLAG REQUESTS DATA 250ns Setup time COMMAND HOLD TIME 600ns WORD TRANSFER
STATUS WORD TRANSFERRED ENCODER REGISTERS
ENCODER REGISTERS AVAILABLE NEXT WORD REQUESTS DATA DATA WORD TRANSFER (RTFAIL CLEARED SET)
FIGURE TRANSMIT TIMING DIAGRAM
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
DATA 151413 1110 DATA 1312 1110
3.4±0.5µS 1.2±.0.5µs 1.2±.0.5µs
200ns
9.8µs
200ns
100-150ns
100-150ns
CURRENT WORD COUNT 00001 note Data
CURRENT WORD COUNT 00010
note Data
50ns 225-275ns 475-550ns SUBSYSTEM DATA MUST VALID DATA WORD TRANSFER DTGRT RECOGNIZED DATA TRANSFER STARTS, SUBSYSTEM SHOULD DRIVING DATA ENCODER REGISTERS AVAILABLE NEXT WORD REQUESTS DATA DATA WORD TRANSFER
225-275ns 50ns 475-550ns SUBSYSTEM DATA MUST VALID DATA WORD TRANSFER DTGRT RECOGNIZED DATA TRANSFER STARTS, SUBSYSTEM SHOULD DRIVING DATA INTERNAL DATA BUFFERS OUTPUTS
NOTES
LEGEND DON'T CARE DATA UNDEFINED EACH WORD DRIVEN 18-19µS D15-D05. ACTIVE LAST WORD AVAILABLE 3.5-4µS SINCE STATUS WORD MUST SUPPORTED. DATA SHOWN WITH CONNECTED DTACK (SEE FUNCTION TABLE, POSITION DTACK WILL VARY DEPENDING WHEN DTGRT ISSUED. HSFAIL ASSERTED UPON EXCESS DTGRT RESPONSE TIME. INCMD WILL SUBSEQUENTLY LOW, FURTHER DATA TRANSFERS WILL OCCUR. RTFAIL CLEARED WHEN STATUS WORD TRANSMITTED. ONCE SET, FLAG WILL REMAIN ENTIRE MESSAGE. INCMD FALLING EDGE USED LATCH RTFAIL STATUS. 100nS REPRESENTS SETUP TIME VALID DATA BEFORE DTSTR GOES WRITE CYCLE. READ CYCLE REQUIRES VALID DATA AFTER DTACK GOES
FIGURE TRANSMIT TIMING DIAGRAM (CON'T)
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
250ns
250ns
RECEIVE WORDS
1553 151413121110 DATA 151413 1110 DATA 15141312 1110
0.5µs
0.5µs
0.5µs
NBGT 100-150ns INCMD DTREQ DTGRT DTACK 2.4µs 100-150ns 450-550ns
PREVIOUS MESSAGE
825-925ns 200ns 250ns
200ns 250ns 3.3µs
DTSTR (T/R BIT) DAT/CMD
50ns
100-150ns
100-150ns
A9-A5 PREV 200-400ns A4-A0 D15-D0
PREVIOUS WORD COUNT WORD COUNT
COMMAND WORD SUBADDRESS FIELD
CURRENT WORD COUNT 00000 note 100ns note 100ns
STATEN BITEN 100ns FAIL RTFAIL 225-275ns 50ns 475-550ns 825-925ns 3.5µs A10-A0 VALID (COMMAND WORD) START COMMAND WORD INITIALIZATION DTGRT RECOGNIZED
100ns
225-275ns 50ns DATA VALID DATA WORD RECEIVED VALIDATED REQUESTS DATA DATA WORD TRANSFER 475-550ns DATA WORD TRANSFER DTGRT RECOGNIZED DATA TRANSFER STARTS
COMMAND WORD TRANSFER SUBSYSTEM STATUS INPUTS STROBED BUSY SSFLAG ADBC RTFLAG 250ns Setup time HOLD TIME 600ns
ILLCMD STROBED A4-A0 (CURRENT WORD COUNTER) REQUESTS DATA COMMAND WORD TRANSFER
FIGURE RECEIVE TIMING DIAGRAM
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
STATUS 15141312 1110 3.4±0.5µs
1.2±0.5µs
250ns 3.3µs
100-150ns
100-150ns
CURRENT WORD COUNT 00001 note
CURRENT WORD COUNT 00010
5.88µs
225-275ns 50ns
225-275ns 50ns 475-550ns FAIL CLEARED
DATA VALID DATA WORD RECEIVED VALIDATED REQUESTS DATA DATA WORD TRANSFER 475-550ns DATAWORD TRANSFER DTGRT RECOGNIZED DATA TRANSFER STARTS
NOTES
LEGEND DON'T CARE DATA UNDEFINED REPRESENTS SEQUENCE EVENTS COMMAND BROADCAST. NOTE: STATUS WOULD TRANSMITTED 1553 BUS. EACH WORD DRIVEN 18-19µS D15-D0. ACTIVE LAST WORD AVAILABLE 3.5-4µS SINCE STATUS WORD MUST SUPPORTED. DATA SHOWN WITH CONNECTED DTACK (SEE FUNCTION TABLE, POSITION DTACK WILL VARY DEPENDING WHEN DTGRT ISSUED. HSFAIL ASSERTED UPON EXCESS DTGRT RESPONSE TIME. WILL SET. RTFAIL CLEARED WHEN STATUS WORD TRANSMITTED. ONCE SET, FLAG WILL REMAIN ENTIRE MESSAGE. INCMD FALLING EDGE USED LATCH RTFAIL STATUS. 100ns REPRESENTS SETUP TIME VALID DATA BEFORE DTSTR GOES LOW.
STATUS WORD TRANSFERRED ENCODER REGISTERS MORE CONTINUOUS DATA ENCODER STARTED
FIGURE RECEIVE TIMING DIAGRAM (CON'T)
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
100ns
200ns
TRANSMITTING RESPONSE TIME
RECEIVE COMMAND
TRANSMIT COMMAND
STATUS15 1413121110 DATA 151413 1110 0.5µs 0.5µs
1553 151413121110 DATA 151413 1110 0.5µs
NBGT 100-150ns INCMD 2.1µs DTREQ DTGRT DTACK 100-150ns DTSTR 50ns (T/R BIT) DAT/CMD A9-A5 A4-A0
PREVIOUS SUBADDRESS PREVIOUS WORD COUNT WORD COUNT PREVIOUS MESSAGE
200ns 250ns
100-150ns
100-150ns
100-150ns
COMMAND WORD SUBADDRESS FIELD CURRENT WORD COUNT 00000
note D15-D0 100ns STATEN BITEN FAIL RTFAIL 225-275ns 450-550ns 825-925ns A10-A0 VALID (COMMAND WORD) START COMMAND WORD INITIALIZATION 3.5µsec DTGRT RECOGNIZED VERIFIED TRANSMITTING ADDRESS LATCHED TRANSMITTING STATUS WORD ADDRESS CHECKED 475-550ns DATA WORD RECEIVED VALIDATED REQUESTS DATA DATA WORD TRANSFER 50ns
STATUS INPUTS STROBED BUSY COMMAND WORD FLAG TRANSFER ADBC SUBSYSTEM FLAG ILLCMD STROBED 250ns Setup time A4-A0 0(CURRENT HOLD TIME 600ns WORD COUNTER) REQUESTS DATA COMMAND WORD TRANSFER
FIGURE (RECEIVE) TIMING DIAGRAM
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
9±1µs DATA 151413121110 1.1±0.5µs STATUS 15141312 1110 1.2±0.5µs 3.4±0.5µs
3.3µs 200ns 250ns
3.3µs 200ns 250ns
225-275ns 100-150ns
225-275ns 100-150ns 100-150ns
CURRENT WORD COUNT 00001
CURRENT WORD COUNT 00010
note6 100ns
note6 100ns
4.5µs
225-275ns 50ns DATA VALID 475-550ns DATA WORD TRANSFER DTGRT RECOGNIZED DATA TRANSFER STARTS DATA WORD RECEIVED VALIDATED REQUESTS DATA DATA WORD TRANSFER
225-275ns
225-275ns 50ns DATA VALID 475-550ns
50ns 475-550ns
FAIL CLEARED
DATA WORD TRANSFER DTGRT RECOGNIZED DATA TRANSFER STARTS
NOTES
STATUS WORD TRANSFER ENCODER REGISTERS MORE CONTINUOUS DATA ENCODER STARTED
LEGEND DON'T CARE DATA UNDEFINED REPRESENTS SEQUENCE EVENTS COMMAND BROADCAST. NOTE: STATUS WOULD TRANSMITTED 1553 BUS. EACH WORD DRIVEN 18-19µS D15-D0. ACTIVE LAST WORD AVAILABLE 3.5-4µS SINCE STATUS WORD MUST SUPPORTED. DATA SHOWN WITH CONNECTED DTACK (SEE FUNCTION TABLE, TIMING DIAGRAM REPRESENTS DTGRT RESPONSE TIME 0.92µS COMMAND TRANSFER 2.1µS DATA. MAXIMUM RESPONSE TIME FROM DTREQ DTGRT GUARANTEE SUCCESSFUL TRANSFER 2.4µS COMMAND TRANSFER 3.3µS DATA TRANSFER SUBSYSTEM. POSITION DTACK WILL VARY DEPENDING WHEN DGRT ISSUED RTFAIL CLEARED WHEN STATUS WORD TRANSMITTED. ONCE SET, FLAG WILL REMAIN ENTIRE MESSAGE. INCMD FALLING EDGE USED LATCH RTFAIL STATUS. 100nS REPRESENTS SETUP TIME VALID DATA BEFORE DTSTR GOES LOW.
FIGURE (RECEIVE) TIMING DIAGRAM (CON'T)
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
RECEIVE COMMAND
TRANSMIT COMMAND
TRANSMIT WORDS
STATUS151413121110
1553 151413121110 DATA 151413 1110
0.5µs
0.5µs
NBGT INCMD DTREQ DTGRT DTACK 2.4µs 100-150ns DTSTR A10(T/R BIT) DAT/CMD A9-A5 A4-A0 PREVIOUS SUBADDRESS PREVIOUS WORD COUNT WORD COUNT note D15-D0 100ns STATEN BITEN FAIL RTFAIL 450-550ns 225-275ns 50ns 475-550ns 825-925ns 3.5µs 5.88µs A10-A0 VALID (COMMAND WORD) DTGRT RECOGNIZED MORE CONTINUOUS DATA ENCODER STARTED ENCODER REGISTERS AVAILABLE NEXT WORD REQUESTS DATA DATA WORD TRANSFER (RTFAIL CLEARED SET) 475-550ns 225-275ns 50ns INTERNAL DATA BUFFERS INPUTS COMMAND WORD SUBADDRESS FIELD CURRENT WORD COUNT 00000 PREVIOUS MESSAGE 200-400ns 50ns 100-150ns 100-150ns 100-150ns
250ns 9.8µs
COMMAND WORD TRANSFER SUBSYSTEM START ILLCMD STROBED COMMAND WORD STATUS INPUTS INITIALIZATION A4-A0 0(CURRENT STROBED WORD COUNTER) REQUESTS DATA BUSY COMMAND FLAG WORD TRANSFER ADBC FLAG 250ns Setup time HOLD TIME 600ns
STATUS WORD TRANSFERRED ENCODER REGISTERS
FIGURE (TRANSMIT) TIMING DIAGRAM
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
4-12µs RECEIVING RESPONSE TIME
DATA 151413121110 DATA 151413 1110
STATUS15 141312 1110
1.2±0.5µs
1.2±0.5µs
3.4±0.5µs
250ns
250ns 9.35µs
100-150ns
100-150ns
CURRENT WORD COUNT=00001
CURRENT WORD COUNT=00010
note DATA 100ns
note DATA 100ns
225-275ns 475-550ns 50ns
225-275ns 475-550ns INTERNAL DATA BUFFERS INPUTS 50ns SUBSYSTEM DATA MUST VALID DATA WORD TRANSFER INTERNAL DATA BUFFERS OUTPUTS
SUBSYSTEM DATA MUST VALID
DATA WORD ENCODER REGISTERS TRANSFER AVAILABLE NEXT DTGRT WORD RECOGNIZED REQUESTS DATA DATA TRANSFER DATA WORD STARTS, SUBSYSTEM TRANSFER SHOULD DRIVING DATA
DTGRT RECOGNIZED DATA TRANSFER STARTS, SUBSYSTEM SHOULD DRIVING DATA
NOTES
LEGEND DON'T CARE DATA UNDEFINED REPRESENTS SEQUENCE EVENTS COMMAND BROADCAST. NOTE: STATUS WOULD TRANSMITTED 1553 BUS. EACH WORD DRIVEN 18-19µS D15-D0. ACTIVE LAST WORD AVAILABLE 3.5-4µS SINCE STATUS WORD MUST SUPPORTED. DATA SHOWN WITH CONNECTED DTACK (SEE FUNCTION TABLE, MAXIMUM RESPONSE TIME FROM DTREQ DTGRT GUARANTEE SUCCESSFUL TRANSFER 2.4µS FROM COMMAND WORD 9.8µS FROM DATA TRANSFER FROM SUBSYSTEM. POSITION DTACK WILL VARY DEPENDING WHEN DGRT ISSUED. RTFAIL CLEARED WHEN STATUS WORD TRANSMITTED. ONCE SET, FLAG WILL REMAIN ENTIRE MESSAGE. INCMD FALLING EDGE USED LATCH RTFAIL STATUS. 100nS REPRESENTS SETUP TIME VALID DATA BEFORE DTSTR GOES WRITE CYCLE. READ CYCLE REQUIRES VALID DATA 150nS AFTER DTACK GOES LOW.
FIGURE (TRANSMIT) TIMING DIAGRAM (CON'T)
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
MODE CODES
BU-63705 implements mode codes applicable dualredundant systems. Mode codes also illegalized using appropriate signals. Mode command illegalization handling detailed below TABLE
TABLE MODE CODES IMPLEMENTED
DYNAMIC CONTROL (00000) MESSAGE SEQUENCE STATUS responds with status. subsystem wants control bus, must DBACC. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error, (SW), High Word Count (BIT Word). Zero. status response. Bits set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code, Error (BIT Word). Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code (BIT Word). SYNCHRONIZE WITHOUT DATA WORD (00001) MESSAGE SEQUENCE SYNC STATUS responds with status. sent broadcast, broadcast receive will status response suppressed. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word) Zero. status response. Bits set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error (BIT Word).
STATUS WORD (00010) MESSAGE SEQUENCE TRANSMIT WORD STATUS status word registers altered this command contain status from previous command. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW) Zero. status response. Bits set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error (BIT Word). Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code (BIT Word).
INITIATE SELF-TEST (00011) MESSAGE SEQUENCE SELF TEST STATUS responds with status word. command broadcast, broadcast received status transmission suppressed. Short-loop test initiated status word transmitted. test fails, fail flag set. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word) Zero. status response. Bits set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error (BIT Word). Fault Test. Bits set: RTFail Output Flag, Loop Test Fail, Current 1553 Loop Test Fail (BIT Word)
TRANSMITTER SHUTDOWN (00100) MESSAGE SEQUENCE =SHUTDOWN STATUS This command only used with dual redundant systems. responds with status. status transmission, inhibits further transmission from dual redundant channel. Once shutdown, transmitter only reactivated OVERRIDE TRANSMITTER SHUTDOWN RESET commands RESET. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word) Zero. status response. Bits set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error (BIT Word).
Status Response Time
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE MODE CODES IMPLEMENTED (continued)
OVERRIDE TRANSMITTER SHUTDOWN (00101) MESSAGE SEQUENCE OVERRIDE SHUTDOWN STATUS This command only used with dual redundant systems. responds with status. status transmission, reenables transmitter redundant bus. command broadcast, broadcast received status transmission suppressed. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word) Zero. status response. Bits set: message error, Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error (BIT Word). INHIBIT TERMINAL FLAG (00110) MESSAGE SEQUENCE INHIBIT TERMINAL FLAG STATUS responds with status inhibits further internal external setting terminal flag status register. Once terminal flag been inhibited, only reactivated Override Inhibit Terminal Flag Reset command RESET. command broadcast, broadcast received status transmission suppressed. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word) Zero. status response. Bits set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error (BIT Word).
OVERRIDE INHIBIT TERMINAL FLAG (00111) MESSAGE SEQUENCE OVERRIDE INHIBIT TERMINAL FLAG STATUS responds with status reactivates terminal flag status register. command broadcast, broadcast received status transmission suppressed. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word) Zero. status response. Bits set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error (BIT Word).
RESET REMOTE TERMINAL (01000) MESSAGE SEQUENCE RESET REMOTE TERMINAL STATUS responds with status internally resets. Transmitter shutdown Inhibit Terminal Flag commands Word, will reset. command broadcast, broadcast received status word suppressed. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word). Zero. status response. Bits Set: message error (S/W), Error (BIT Word). Zero Broadcast Address. status response. Bits set: message error, broadcast received (S/W), Error (BIT Word).
RESERVED MODE COMMAND (01001-01111) MESSAGE SEQUENCE RESERVED MODE COMMAND STATUS responds with clear status data. command illegalized through optional PROM, message error only status word transmitted. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word), Illegal Mode Code (BIT Word) Zero. status response. Bits set: message error (S/W), Illegal Mode Code (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code (BIT Word). Status Response Time
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE MODE CODES IMPLEMENTED (continued)
TRANSMIT VECTOR WORD (10000) MESSAGE SEQUENCE TRANSMIT VECTOR WORD STATUS VECTOR WORD transmits status word followed vector word. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count (BIT Word) Zero. status response. Bits set: message error (S/W), Word Count (BIT Word) Error (BIT Word). Zero Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Error, Word Count (BIT Word). Broadcast Address. status response. Bits set: message error, broadcast received (S/W), Illegal Mode Code, (BIT Word). SYNCHRONIZE WITH DATA WORD (10001) MESSAGE SEQUENCE SYNCHRONIZE WITH DATA WORD STATUS data word received following command word transferred RAM. status word then transmitted. command broadcast, broadcast received status transmission suppressed. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), Word Count (BIT Word) Command Followed many Data Words. status response. Bits Set: message error (SW), High Word Count (BIT Word) Command One. status response. Bits set: message error (S/W), Error, High Word Count (BIT Word). Command Broadcast Address. status response. Bits set: message error, broadcast received (S/W), High Word Count, Error (BIT Word). TRANSMIT LAST COMMAND (10010) MESSAGE SEQUENCE TRANSMIT LAST COMMAND STATUS status word registers altered this command. contains status from previous command. data word transmitted contains previous valid command (providing another TRANSMIT LAST COMMAND). ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW). Zero. status response. Bits set: message error (S/W), Error, Word Count (BIT Word). Zero Broadcast Address. status response. Bits Set: message error (S/W), Broadcast (S/W), Error (BIT Word), Word Count (BIT Word). Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code (BIT Word).
TRANSMIT WORD (10011) MESSAGE SEQUENCE TRANSMIT WORD STATUS responds with status followed word. word altered this command; however, next will reflect errors this transmission. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: Message Error (S/W)
Status Response Time
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE MODE CODES IMPLEMENTED (continued)
SELECTED TRANSMITTER SHUTDOWN (10100) MESSAGE SEQUENCE SELECTED TRANSMITTER SHUTDOWN STATUS VECTOR WORD data word received transmitted subsystem status transmitted. other action taken RTU. command broadcast, broadcast received status transmission suppressed. Intended with RT's with more than dual redundant channel. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), Word Count, Illegal Mode Code (BIT Word) Command Followed many Data Words. status response. Bits Set: message error (SW), High Word Count, Illegal Mode Code (BIT Word) Command One. status response. Bits set: message error (S/W), Illegal Mode Code, High Word Count (BIT Word). Command Broadcast Address. status response. Bits Set: message error, broadcast received (S/W), Illegal Mode Code, High Word Count (BIT Word). OVERRIDE SELECTED TRANSMITTER SHUTDOWN (10101) MESSAGE SEQUENCE OVERRIDE SELECTED TRANSMITTER SHUTDOWN STATUS data word received after command transferred subsystem. other action taken RTU. command broadcast, broadcast received status transmission suppressed. ERROR CONDITIONS Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), Word Count, Illegal Mode Code (BIT Word) Command Followed many Data Words. status response. Bits Set: message error (SW), High Word Count, Illegal Mode Code (BIT Word) Command One. status response. Bits set: message error (S/W), Illegal Mode Code, High Word Count (BIT Word). Command Broadcast Address. status response. Bits set: message error, broadcast received (S/W), Illegal Mode Code, High Word Count (BIT Word). RESERVED MODE CODES (10110-11111) MESSAGE SEQUENCE RESERVED MODE CODE (T/R STATUS RESERVED MODE CODE (T/R STATUS Valid (T/R responds with status. command broadcast, broadcast received status transmission suppressed. command illegalized through optional PROM, message error only status word transmitted. Valid (T/R Respond with status data word. ERROR CONDITIONS (T/R Invalid Command. response, command ignored. Command Followed Data Word. status response. Bits Set: message error (SW), High Word Count, Illegal Mode Code (BIT Word). ERROR CONDITIONS (T/R Invalid Command. response, command ignored. Command followed Contiguous Data Word. status response. Bits set: message error (S/W), Word Count, Illegal Mode Code (BIT Word). Command followed many Data Words. status response. Bits Set: message error (S/W), High Word Count, Illegal Mode Code (BIT Word). UNDEFINED MODE CODES (T/R MODE CODES 00000 01111) Response, message error status (T/R Error (BIT Word) [00000-01001] Illegal Mode (BIT Word) [01001-01111]). Status Response Time
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE FUNCTIONS
PACKAGE 78-Pin 78-Pin FlatPack FUNCTION DESCRIPTION 78-Pin
TABLE FUNCTIONS (continued)
PACKAGE 78-Pin FlatPack FUNCTION DESCRIPTION
(SA4) (SA2) (SA0) DB11 DB13 DB15
Latched output most significant (MSB) subaddress field command word. Latched output third most significant subaddress field command word. Latched output least significant (LSB) subaddress field command word. Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data (MSB) Broadcast enable when HIGH, this input allows recognition address ones command word broadcast message. When LOW, prevents response address unless assigned terminal address. Input assigned terminal address. Input assigned terminal address. Input assigned terminal address. Output signal used inform subsystem address parity error. LOW, indicates parity error will respond command address single terminal. will respond broadcast commands HIGH. output primary side coupling transformer that connects channel 1553 bus. Power Supply return connection channel transceiver. Input from HIGH side primary side coupling transformer that connects channel 1553 Bus. Multiplexed address line output. When INCMD thru zeroes ones (Mode Command), represents latched output word count field command word. When INCMD HIGH thru zeroes ones, represents current word counter. Multiplexed address line output. When INCMD thru zeroes ones (Mode Command), represents latched output word count field command word. When INCMD HIGH thru zeroes ones, represents current word counter.
DTGRT
Data transfer grant active input signal from subsystem that informs when DTREQ asserted, start transfer. Once transfer started, DTGRT removed. In-Command HIGH level output signal used inform subsystem that presently servicing command. Handshake Fail output signal that goes stays whenever subsystem fails supply DTGRT time successful transfer. Cleared next NBGT. level output pulse (125ns) present middle every data word transfer over parallel data bus. Used latch strobe data into memory, FIFOs, registers, etc. Recommended using rising edge clock data
INCMD
HSFAIL
DTSTR
Address line output that whenever command word being transferred (DAT/CMD) subsystem over parallel data bus, HIGH whenever data words being transferred. Remote Terminal Failure latched active output signal subsystem flag detection remote terminal continuous self-test failure. Also Watchdog Timeout circuit activated. Cleared start next message transmission (status word) problem again detected. Data Transfer Request active output signal subsystem indicating that data needs data from subsystem requests data transfer over parallel data bus. Will stay until transfer completed transfer timeout occurred. Accept Dynamic Control active input signal from subsystem used Dynamic Control Acceptance status register command word valid, legal mode command dynamic control. Factory test point output-DO (see note Latched output command word. Illegal Command active input signal from subsystem, strobed rising edge INCMD. Used define command word illegal message error status register. Subsystem Service Request Input from subsystem used control Service Request status register. when status word updated, Service Request will set; HIGH, will cleared. Built-in-Test Word Enable level output pulse (.5µs), present when built-in-test word enabled parallel data bus. Input from side primary
ADDRE (RTAD4) ADDRC (RTAD2) ADDRA (RTAD0)
RTFAIL
DTREQ
RTADERR
TXDATA RXDATA
ADBC
TEST (T/R)
(WC3/ CWC3)
ILLCMD
(WC1/ CWC1)
BITEN
RXDATA side coupling transformer that connects channel 1553 Bus.
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE FUNCTIONS (continued)
PACKAGE 78-Pin 78-Pin FlatPack FUNCTION DESCRIPTION 78-Pin
TABLE FUNCTIONS (continued)
PACKAGE
78-Pin FUNCTION FlatPack
DESCRIPTION
+5VA
input power supply connection channel transceiver. -15V/-12V input power supply connection BU-63705X1/2 Channel transceiver connection BU63705X3). HIGH output primary side
(WCO/ CSWO)
Multiplexed address line output. When INCMD thru zeroes ones (Mode Command), represents latched output word count field command word. When INCMD HIGH thru zeroes ones, represents current word counter. Data Transfer Acknowledge active output signal during data transfers from subsystem indicating received DTGRT response DTREQ presently doing transfer. connected directly (BUF ENA) control tri-state data buffers; tri-state address buffer control lines, they used. Multiplexed address line output. When INCMD thru zeroes ones (Mode Command), represents latched output word count field command word. When INCMD HIGH thru zeroes ones, represents current word counter. Read/Write output signal controls direction internal data buffers (logic "1"= reading data D15-D0; logic writing data D15-D0). Prior reception 1553 command word, RD/WR will logic "0", indicating that BU(S)-65142 writing data connected subsystem. Following reception/transfer transmit command word, RD/WR transitions from high, remains high until after last data word read from system transmission 1553 bus. After that last data word transfer, RD/WR returns logic "0". Good Block Received level output pulse (.5µs) used flag subsystem that valid, legal, non-mode receive command with correct number data words been received without message error successfully transferred subsystem. 16MHz Clock Input input master clock used circuits. Buffer Enable input used enable tristate internal data buffers when they driving bus. When LOW, data buffers enabled. Could connected DTACK, sharing same data subsystem. (see note 2)*. Input resets entire when LOW. Remote Terminal Flag Input signal used control terminal flag status register. when status word updated, terminal flag would set; HIGH, would cleared. Normally connected RTFAIL. Watchdog Timeout test point USE. (See note (input).
TXDATA coupling transformer that connects
channel 1553 Bus. Grant level output pulse (125ns) used indicate start protocol sequence response command word just received. Latched output subaddress field command word. Latched output subaddress field command word. Bi-directional parallel data (LSB) Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data Bi-directional parallel data input power supply connection digital logic section. Power supply return digital logic section. Input assigned terminal address. Input assigned terminal address. Input Address Parity Bit. combination assigned terminal address ADDRP must parity work. HIGH, output primary side
NBGT (SA3) (SA1) DB10 DB12 DB14 ADDRD ADDRB ADDRP
DTACK
(WC4/ CWC4)
RD/WR
TXDATA coupling transformer that connects
channel transceiver. -15V/-12V input power supply connection BU-63705X1/2 Channel transceiver connection BU-63705X3). input power supply connection channel transceiver. Input from side primary side coupling transformer that connects channel 1553 Bus. Multiplexed address line output. When INCMD thru zeroes ones (Mode Command), represents latched output word count field command word. When INCMD HIGH thru zeroes ones, represents current word counter.
16MHz
+5VB RXDATA
RESET
(WC2/ CSW2)
RTFLAG
TEST
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
TABLE FUNCTIONS (continued)
PACKAGE 78-Pin 78-Pin FlatPack FUNCTION DESCRIPTION
FUNCTION TABLE NOTES (TABLE TEST Factory Test Point This provides output BU-63705 Comparison output. logic (high) indicates mismatch. Normally this left open. BUFENA This typically tied DTACK, causing BU-63705 drive shared data only while DTACK active. desired BUFENA grounded. data will remain latched data pins 18µs from DTSTR 3.5µs last word message device's status word word transferred (STATEN BITEN low). Once STATUS Word transfer complete, data will automatically again contain last data word. BU-63705 will automatically switch direction internal buffers during transmit operation. TEST This test allows user force active channel transmit indefinitely, order test built-in Watchdog Timer feature BU63705. When this grounded active channel stimulated with valid transmit command, BU-63705 will respond with status word contiguous data (last data word loaded STATUS WORD none loaded) until built-in time occurs. Normally this left open optional pull-up used. connected (N/C) BU-63705X3.
SSBUSY
SSFLAG
Subsystem Busy input from subsystem used control busy status register. when status word updated, busy will set, HIGH will cleared. busy status register, data will requested from subsystem response transmit command. receive commands, data will transferred subsystem. Subsystem Flag input from subsystem used control subsystem flag status register. when status word updated, subsystem flag will set; HIGH will cleared. Message Error output signal that goes stays whenever there format word error with received message over 1553 Data Bus. Cleared next NGBT. Input from HIGH side primary side coupling transformer that connects channel 1553 Bus. Power supply return connection channel transceiver. connected. output primary side coupling transformer that connects channel 1553 Bus. Status Word Enable level active output signal present when status word enabled parallel data bus. These pins used this package.
RXDATA
TXDATA
STATEN
0.210 (5.33)
2.100 (53)
NUMBERS REFERENCE ONLY
1.500 (38)
1.800 (46) 1.650 (42)
0.100 (2.54) 0.050 (1.27) DETAIL 1.800 (46) 1.900 (48) INDEX DENOTES
0.018 ±0.002 (0.46 ±0.05) 0.250 ±0.010 (6.35 ±0.25)
DETAIL
NOTE: DIMENSIONS INCHES (MM).
FIGURE BU-63705D MECHANICAL OUTLINE (HI-REL RADIATION TOLERANT VERSION) (78-PIN CERAMIC QIP)
Data Device Corporation www.ddc-web.com BU-63705 A-04/05-1M
0.425 ±.020 (10.80)
DENOTED INDEX LEAD BRAZE
0.575 ±.020 (14.61) 1.800 (45.72) 0.400 (10.16)
2.100 (53.34) 0.018 ±.002 (0.457)
0.050 1.90 NONCUM (1.27 48.26)
NUMBERS REFERENCE ONLY
0.050 (1.27) 0.010 ±0.002 (0.25 ±0.05) 0.050 (1.27)
0.100 ±0.010 (2.54 ±0.25) 0.210 (5.33) 1.824 (46.32) 0.010 (0.254)
0.035 (0.89)
NOTES: LEAD CLUSTER CENTRALIZED ABOUT CASE CENTER LINE WITHIN ±0.010. DIMENSIONS INCHES (MM).
FIGURE BU-63705F MECHANICAL OUTLINE (HI-REL RADIATION TOLERANT VERSION) (78-PIN CERAMIC FLAT PACK)
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
ORDERING INFORMATION
BU-63705F3-120X Supplemental Process Requirements: Pre-Cap Source Inspection 100% Pull Test (standard this device) 100% Pull Test Pre-Cap Source Inspection Date Code Date Code PreCap Source Inspection Date Code 100% Pull Test Date Code, PreCap Source Inspection 100% Pull Test Blank None Above Test Criteria: Standard Testing X-Ray Process Requirements: Standard Processing, Burn-In MIL-PRF-38534 Compliant (notes (note MIL-PRF-38534 Compliant (notes with PIND Testing MIL-PRF-38534 Compliant (notes with Solder MIL-PRF-38534 Compliant (notes with PIND Testing Solder (note with PIND Testing (note with Solder (note with PIND Testing Solder Standard Processing with Solder Dip, Burn-In Temperature Grade/Data Requirements: -55°C +125°C -40°C +85°C +70°C -55°C +125°C with Variables Test Data -40°C +85°C with Variables Test Data +70°C with Variables Test Data Transceiver Option: Volts Volts Volts Volts Volts (Only) Package Options: 78-pin Package 78-pin Flatpack Product Type: BU-63705 "SPACE Radiation Tolerant Remote Terminal
(Consult Factory Local Representative Lead Times.) Notes: Standard processing this device includes hours burn-in 100% non-destruct pull-test. (See Table Standard Processing with burn-in full temperature (-55°C +125°C) test. MIL-PRF-38534 product grading designated with following dash numbers: Class -11X, 13X, 14X, 15X, 41X, 43X, 44X, Class -21X, 23X, 24X, 25X, 51X, 53X, 54X, Class -31X, 33X, 34X, 35X, 81X, 83X, 84X,
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
NOTES
Data Device Corporation www.ddc-web.com
BU-63705 A-04/05-1M
information this data sheet believed accurate; however, responsibility assumed Data Device Corporation use, license rights granted implication otherwise connection therewith. Specifications subject change without notice. Please visit site www.ddc-web.com latest information.
Wilbur Place, Bohemia, York, U.S.A. 11716-2482 Technical Support 1-800-DDC-5757 ext. 7771 Headquarters, N.Y., U.S.A. Tel: (631) 567-5600, Fax: (631) 567-7358 Southeast, U.S.A. Tel: (703) 450-7900, Fax: (703) 450-6610 West Coast, U.S.A. Tel: (714) 895-9777, Fax: (714) 895-4988 United Kingdom Tel: +44-(0)1635-811140, Fax: +44-(0)1635-32264 Ireland Tel: +353-21-341065, Fax: +353-21-341568 France Tel: +33-(0)1-41-16-3424, Fax: +33-(0)1-41-16-3425 Germany Tel: +49-(0)89-150012-11, Fax: +49-(0)89-150012-22 Japan Tel: +81-(0)3-3814-7688, Fax: +81-(0)3-3814-7689 World Wide http://www.ddc-web.com
ERED
DATA DEVICE CORPORATION REGISTERED 9001:2000 FILE A5976
A-04/05-1M
PRINTED U.S.A.

Other recent searches


SF2063A - SF2063A   SF2063A Datasheet
SC4809A - SC4809A   SC4809A Datasheet
MAX4278 - MAX4278   MAX4278 Datasheet
MAX4178 - MAX4178   MAX4178 Datasheet
MAX4278 - MAX4278   MAX4278 Datasheet
MAX4178ESA - MAX4178ESA   MAX4178ESA Datasheet
DL5221C - DL5221C   DL5221C Datasheet
DL5267C - DL5267C   DL5267C Datasheet
D32FU - D32FU   D32FU Datasheet
AN1064 - AN1064   AN1064 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive