The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Getting Started Programmer Operations Command Reference Keyboard Refer


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



HW-130 Programmer User Guide
Getting Started Programmer Operations Command Reference Keyboard Reference Diagnostics Procedures Automation Wiring Conventions
HW-130 Programmer User Guide 0401575
Printed U.S.A.
HW-130 Programmer User Guide
XILINX, XACT, XC2064, XC3090, XC4005, XC-DS501, FPGA Architect, FPGA Foundry, NeoCAD, NeoCAD EPIC, NeoCAD PRISM, NeoROUTE, Plus Array, Plustran, Timing Wizard, TRACE registered trademarks Xilinx. XC-prefix product designations, XACTstep, XACTstep Advanced, XACTstep Foundry, XACT-Floorplanner, XACT-Performance, XAPP, XAM, X-BLOX, X-BLOX plus, XChecker, XDM, XDS, XEPLD, XPP, XSI, BITA, Configurable Logic Cell, CLC, Dual Block, FastCLK, FastCONNECT, FastFLASH, FastMap, HardWire, LCA, Logic Cell, LogiCore, LogicProfessor, MicroVia, PLUSASM, PowerGuide, PowerMaze, Select-RAM, SMARTswitch, TrueMap, UIM, VectorMaze, VersaBlock, VersaRing, ZERO+ trademarks Xilinx. Programmable Logic Company Programmable Gate Array Company service marks Xilinx. registered trademark PC/AT, PC/XT, PS/2 Micro Channel trademarks International Business Machines Corporation. DASH, Data FutureNet registered trademarks ABEL, ABEL-HDL ABELPLA trademarks Data Corporation. SimuCad Silos registered trademarks P-Silos P/CSilos trademarks SimuCad Corporation. Microsoft registered trademark MS-DOS trademark Microsoft Corporation. Centronics registered trademark Centronics Data Computer Corporation. PALASM registered trademark Advanced Micro Devices, Inc. UNIX trademark AT&T Technologies, Inc. CUPL, PROLINK, MAKEPRG trademarks Logical Devices, Inc. Apollo AEGIS registered trademarks Hewlett-Packard Corporation. Mentor IDEA registered trademarks NETED, Design Architect, QuickSim, QuickSim EXPAND trademarks Mentor Graphics, Inc. registered trademark Microsystems, Inc. SCHEMA SCHEMA trademarks Omation Corporation. OrCAD registered trademark OrCAD Systems Corporation. Viewlogic, Viewsim, Viewdraw registered trademarks Viewlogic Systems, Inc. CASE Technology trademark CASE Technology, division Teradyne Electronic Design Automation Group. DECstation trademark Digital Equipment Corporation. Synopsys registered trademark Synopsys, Inc. Verilog registered trademark Cadence Design Systems, Inc. Xilinx does assume liability arising application product described shown herein; does convey license under patents, copyrights, maskwork rights rights others. Xilinx reserves right make changes, time, order improve reliability, function design supply best product possible. Xilinx will assume responsibility circuitry described herein other than circuitry entirely embodied products. Xilinx devices products protected under more following U.S. Patents: 4,642,487; 4,695,740; 4,706,216; 4,713,557; 4,746,822; 4,750,155; 4,758,985; 4,820,937; 4,821,233; 4,835,418; 4,853,626; 4,855,619; 4,855,669; 4,902,910; 4,940,909; 4,967,107; 5,012,135; 5,023,606; 5,028,821; 5,047,710; 5,068,603; 5,140,193; 5,148,390; 5,155,432; 5,166,858; 5,224,056; 5,243,238; 5,245,277; 5,267,187; 5,291,079; 5,295,090; 5,302,866; 5,319,252; 5,319,254; 5,321,704; 5,329,174; 5,329,181; 5,331,220; 5,331,226; 5,332,929; 5,337,255; 5,343,406; 5,349,248; 5,349,249; 5,349,250; 5,349,691; 5,357,153; 5,360,747; 5,361,229; 5,362,999; 5,365,125; 5,367,207; 5,386,154; 5,394,104; 5,399,924; 5,399,925; 5,410,189; 5,410,194; 5,414,377; 5,422,833; 5,426,378; 5,426,379; 5,430,687; 5,432,719; 5,448,181; 5,448,493; 5,450,021; 5,450,022; 5,453,706; 34,363, 34,444, 34,808. Other U.S. foreign patents pending. Xilinx, Inc. does represent that devices shown products described herein free from patent infringement from other third party right. Xilinx assumes obligation correct errors contained herein advise user this text correction such made. Xilinx will assume liability accuracy correctness engineering software support assistance provided user. Xilinx products intended life support appliances, devices, systems. Xilinx product such applications without written consent appropriate Xilinx officer prohibited. Copyright 1991-1995 Xilinx, Inc. Rights Reserved.
Xilinx Development System
Declaration Conformity
Manufacturer's name address: Xilinx Inc. 2100 Logic Drive Jose, 95124 U.S.A. declares that product: Product name: Programmer Model number: HW-130 conforms following standards: EMC: EN55022:1995 Class EN50082-1:1992 1000-4-2:1995 Level 1000-4-3:1995 Level 1000-4-4:1995 Level Safety: This product complies with requirements Directive 89/336/EEC, Voltage Directive 73/23/EEC. Hardware Engineering Group Jose, U.S.A. April 1997 European contact: Xilinx Ireland Logic Drive, Citywest Business Campus Saggart, Dublin Ireland
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Xilinx Development System
Preface
About This Manual
This manual describes Xilinx's HW-130 Programmer interface software. HW-130 Programmer tool used programming Xilinx programmable devices Windows environment UNIX workstation. Although this manual emphasizes Windows installations, UNIX differences noted where applicable.
Manual Contents
This manual covers following topics.
Chapter "Getting Started," describes HW-130 Programmer hardware explains install hardware accompanying software. Chapter "Programmer Operations," step-by-step description software procedures programmer. Chapter "Command Reference," lists describes programmer commands alphabetically. Appendix "Keyboard Reference," lists keyboard shortcuts used interface with programmer navigate programmer display. Appendix "Diagnostics Procedures," covers auto-calibration diagnostics.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Appendix "Automation," explains programmer with autohandler automate device programming. Appendix "Wiring Conventions," covers power plug serial connector drawings.
Xilinx Development System
Conventions
following conventions used this manual's syntactical statements: Courier font regular Courier font bold italic font System messages program files appear regular Courier font. Literal commands that must enter syntax statements bold Courier font. Variables that replace syntax statements italic font. Square brackets denote optional items parameters. However, specifications, such [7:0], they required. Braces enclose list items from which must choose more. vertical ellipsis indicates material that been omitted. horizontal ellipsis indicates that preceding repeated more times. vertical separates items list choices. This symbol denotes carriage return.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Xilinx Development System
Contents
Declaration Conformity Preface
About This Manual Manual Contents.
Conventions Chapter Getting Started
Hardware Software Requirements. Installations. Workstation Installations. Hardware Installation HW-130 Programmer Description. Installation. Resetting HW-130 Programmer Software Installation. Installing Software from Windows. Installing Software Starting Program Menu Toolbar Display. Status Bar. Installing Software Workstation from CD-ROM Loading CD-ROM into Drive Checking Whether CD-ROM Drive Mounted Mounting CD-ROM Local System Running CD-ROM Installation Script Starting Program Menu Toolbar Display. Status Bar. 1-10 1-11 1-12 1-13 1-13 1-13 1-13
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Installing Software from DOS. Installing Software Configuring Software Setting Communications Options Manually Selecting Commands Dialog Options Using Mouse Using Keyboard Invoking Help
1-14 1-14 1-15 1-15 1-17 1-17 1-17 1-18
Chapter
Programmer Operations
Programming Quickstart Specifying Device (Ctrl-D). Specifying Design (Ctrl-F) Specifying Profile Creating Profile Loading Profile Deleting Profile. Programming Device (Ctrl-P) Loading Device (Ctrl-L) Verifying Device (Ctrl-V). Comparing Device File. Comparing Device Another Checking Blank Device (Ctrl-B) Calculating Device Checksum (Ctrl-K). Viewing Signature String (Ctrl-S) Saving Programmer Memory Contents File (Ctrl-C) Appending Data (Ctrl-A). 2-10 2-10 2-11 2-12
Chapter
Command Reference
Menus File Menu Options Menu. Help Menu. Alphabetical Listing Commands. About HW-130 (Help Menu). Append Data (File Menu). Auto-Calibration (Options Menu) Autohandler Mode (Options Menu). Blank Check Device (Options Menu) Communications (Options Menu) Contents (Help Menu).
viii
Xilinx Development System
Contents
Device Checksum (Options Menu) Diagnostics (Options Menu) Exit (File Menu). Load Master (Options Menu) Summary (File Menu) Open File (File Menu) Profile (File Menu) Program Device (Options Menu) Reset Programmer (Options Menu). Save File (File Menu). Save Settings (File Menu) Select Device (File Menu). Signature String (Options Menu) Sound (Options Menu). Verify Device (Options Menu).
3-10 3-10 3-10 3-10
Appendix Keyboard Reference
Keyboard Commands Quick-Key Reference.
Appendix Diagnostics Procedures
Auto-Calibration Diagnostics RS-232 Serial Communications Test. Memory Test. Driver Clock Test Programmable Supply Voltage Loop
Appendix Automation
Selecting Autohandler Mode. Programmer Operation
Appendix Wiring Conventions
Power Cord Serial Connector
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Xilinx Development System
HW-130 Programmer User Guide
Getting Started
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Chapter
Getting Started
This manual covers installation HW-130 Programmer interface software, which designed program Xilinx programmable device families running DOS, Windows, SunOS, Solaris, UNIX workstations.
Installation HW-130 Programmer interface software covered this chapter. Programming procedures covered "Programmer Operations" chapter. alphabetical list description commands included "Command Reference" chapter.
HW-130 Programmer desktop unit that communicates with host computer system means RS-232 serial port using HW-130 Programmer software. interface software enables select device download algorithm HW-130 Programmer, ensure that device blank, program device, verify that device been programmed correctly.
Hardware Software Requirements
following minimum requirements needed different systems.
Installations
have ensure your system meets following system requirements.
80286 higher
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Version higher (DOS installations only) Windows Windows Windows 3.1x (Windows installations only) RS-232 serial port conventional memory (DOS only) hard disk space available Serial mouse (recommended)
HW-130 Programmer software controls HW-130 Programmer from keyboard mouse. Appendix summary keyboard quick keys.
Workstation Installations
have workstation, ensure your system meets following system requirements.
hard disk space available DB25 serial port with read write permissions X-based Windows Manager (X11R5 higher) Operating System: SunOS: Solaris: HP9000/700: RS6000: SunOS 4.1.3 higher SunOS higher (Solaris higher) HP-UX 09.05 higher 3.2.5.0 higher
HW-130 Programmer software controls HW-130 Programmer from keyboard mouse. Appendix summary keyboard quick keys.
Hardware Installation
This section explains install configure HW-130 Programmer.
Xilinx Development System
Getting Started
HW-130 Programmer Description
HW-130 Programmer comes with following items:
RS-232 9-to-9-pin data cable 9-to-25-pin adapter
25-pin female adapter workstation users 25-pin male adapter workstation users workstation users need 9-to-25-pin adapter
Universal Power Supply Power Cord Software User Guide Vacuum Handling Tool
HW-130 Programmer consists base with 96-pin connector case attach different socket adapters each device package type. Socket adapters available each different product families. indicated Figure 1-1, programmer case three LEDs: (fail), green (pass), power indicator. push-button used operator responses.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Socket Adapter, Removable
HW-133-PC84 XC7300 EPLD Programming Adapter
INSERT LEADS DOWN
LED, Power Indicator
FAIL
PASS
LEDs (2), Fail Pass Indicators Switch, Push-button
HW-130 Programmer
Base, HW-130 Programmer
X4904
Figure Panel Programmer back panel programmer, there power jack, ONOFF power switch, female serial port connector, Ground jack with wrist strap. Figure illustrates these features.
Xilinx Development System
Getting Started
Caution: Programmer damaged static discharge into adapter connector socket. Please follow normal Electro Static Discharge (ESD) precautions when handling devices programmer order avoid damage misprogramming. ground strap when loading unloading devices into socket adapter. caution when inserting removing socket adapters.
RS-232
Figure Rear Panel Programmer
Installation
following instructions HW-130 Programmer using Figure Figure guide you. Turn power switch rear panel programmer. Connect RS-232 cable DB25 serial port your workstation programmer serial port. Connect adapter power connector input line source. Install appropriate socket adapter onto programmer 96pin connector shown Figure 1-1. Ensure that there device socket, power-on self-test (POST) will function. Turn programmer power switch. After power turned POST takes seconds test hardware. Power Indicator flashes during POST then remains lit.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Fail indicator flashes during POST there hardware problem. Refer Table determine nature problem. Table HW-130 Programmer Troubleshooting Fail Indicator Flashing time times times times times times Problem Socket adapter empty EPROM checksum failure Voltage calibration failure PVpp current measurement failure Memory banks failures Memory banks failures
Resetting HW-130 Programmer
reason, programmer stops responding, keyboard locks wish abort operations, select Reset Programmer command from Options menu execute hardware reset. This command causes HW-130 Programmer POST display test results listed Table hardware error occurs. POST runs only once each invocation Reset only active there device socket adapter.
Software Installation
This section covers installation HW-130 Programmer software. section environment using, Windows, UNIX, DOS.
Installing Software from Windows
information this section install program from Windows.
Installing Software
install software, follow these instructions: using diskette, insert diskette into appropriate
Xilinx Development System
Getting Started
drive (typically A:). using CD-ROM, insert into CD-ROM drive (typically D:). Type following invoke Windows: Select from File menu Program Manager. Type following information dialog box. a:\setup.exe (diskette) d:\windows\setup.exe (CD-ROM) HW-130 Installation dialog displayed shown Figure 1-3.
Figure Installation Dialog Click accept default installation directory type name drive directory which want install HW-130 Programmer software.
Starting Program
After finishing installation, start program follows: Turn power HW-130 Programmer. Open Xilinx HW-130 Programmer group click following icon within that program group.
Figure HW-130 Programmer Icon
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Note: software cannot establish communication with programmer, message displayed indicates possible reasons communication failure. HW-130 screen displayed. consists menu toolbar buttons. toolbar buttons allow interface directly with programmer operations.
Menu Toolbar
Display
Status
Figure Main Window (Windows)
Menu
menu located HW-130 Programmer window. includes File, Options, Help menus.
Toolbar
toolbar located screen below menu bar. displays several icons, which specify commands directly. toolbar offers alternative menu commands. Note: version program, command buttons, located bottom screen, replace toolbar. Figure 1-7.
Xilinx Development System
Getting Started
Display
display includes fields that updated with device type, design name, device quantity that select. Additional information appears perform programmer operations.
Status
status located bottom HW-130 Programmer window. provides information about commands that about select that being processed.
Installing Software Workstation from CD-ROM
This section explains install HW-130 software Sun4 (SunOS Solaris), HP9000/700 RS6000 workstations. HW-130 software product graphical interface requires X-based Windows Manager. These instructions describe
Load CD-ROM Check whether CD-ROM drive mounted. Mount CD-ROM drive, necessary. CD-ROM installation script install HW-130 software. Starting program.
Note: commands these instructions show default device name CD-ROM drive. Device names different your system. encounter problems, check your hardware reference manuals your system administrator.
Loading CD-ROM into Drive
CD-ROM caddy insert caddy into drive. caddy plastic case that holds disk. Load disk printed side facing
Checking Whether CD-ROM Drive Mounted
need have CD-ROM drive mounted before install
HW-130 Programmer User Guide
HW-130 Programmer User Guide
software. determine drive already been mounted, type: /etc/mount should list mounted devices. line similar following lines appears list, CD-ROM drive already been mounted your system. Solaris /cdrom /dev/sr0 /cdrom /dev/sr0 /cdrom /dev/dsk/c0t6/ hw130 vold (Volume Management Deamon) running. /cdrom device where device depends your system. /cdrom /dev/cd0
drive been mounted, continue "Running CD-ROM installation script."
Mounting CD-ROM Local System
mount CD-ROM local system, follow these steps: Note: must have root access. Contact your system administrator need help. Create mounting point creating `cdrom` directory. directory /cdrom does already exist, enter: mkdir cdrom Enter mount command your platform. Solaris /etc/mount hsfs /dev/sr0/cdrom /etc/mount hsfs /dev/sr0/cdrom /etc/mount device /cdrom cdfs where device depends your system. Check your hardware reference manuals your system administrator. /etc/mount `cdrfs` /dev/cd0/cdrom
1-10
Xilinx Development System
Getting Started
Verify that drive mounted correctly typing: /etc/mount displayed list mounted devices should include drive just mounted.
Running CD-ROM Installation Script
easiest install software installation script from CD-ROM. Type CD-ROM installation command your platform: Solaris: /cdrom/install /cdrom/install Note: Vold (Volume Management Deamon) might have mounted CD-ROM `/cdrom/hw130' `/cdrom/cdrom0' which case should `/cdrom/hw130/install' `/cdrom/cdrom0/install' /cdrom/install /cdrom/install.rs6
IBM:
CD-ROM installation script will un-tar file `hw130' located /cdrom/<platform_dir> target directory install_dir. script will also allow change install_dir agree with displayed default directory. Follow instructions screen. Note: install script fails install software, manually un-tar HW-130 software from appropriate subdirectory install_dir. Create install_dir target directory change directory (cd) mkdir <install_dir> <install_dir>
HW-130 Programmer User Guide
1-11
HW-130 Programmer User Guide
manually copy files your current directory, enter following command command line: Solaris: xvf/cdrom/sn2/hw130 xvf/cdrom/sol/hw130 Note: Vold (Volume Management Deamon) might have mounted CD-ROM `/cdrom/hw130' `/cdrom/cdrom0' which case should `tar /cdrom/hw130/sol/hw130' `tar /cdrom/cdrom0/sol/hw130' /cdrom/hp7/hw130 /cdrom/rs6/hw130
IBM:
further setup required software.
Starting Program
After finishing installation, start program follows: Launch X-based Windows Manager (e.g. OpenLook, OpenWindows Motif Window Manager) your system already running. Note: HW-130 software graphical interface requires X-based Windows Manager. Connect programmer serial port workstation power supply programmer. Turn power switch back HW-130 Programmer. Change directory install_dir (the directory where software installed) type following command line: hw130 Note: software cannot establish communication with programmer, message displayed indicates possible reasons communication failure. HW-130 screen displayed. consists menu toolbar buttons. toolbar buttons allow interface directly with programmer operations.
1-12
Xilinx Development System
Getting Started
Menu Toolbar
Display
Status
Figure Main Window (UNIX Workstations)
Menu
menu located HW-130 Programmer window. includes File, Options, Help menus.
Toolbar
toolbar located screen below menu bar. displays several icons, which specify commands directly. toolbar offers alternative menu commands.
Display
display includes fields that updated with device type, design name, device quantity that select. Additional information appears perform programmer operations.
Status
status located bottom HW-130 Programmer window. provides information about commands that about select that being processed.
HW-130 Programmer User Guide
1-13
HW-130 Programmer User Guide
Installing Software from
This section covers installation program start-up from DOS.
Installing Software
install software, follow these instructions: Insert HW-130 Programmer software diskette into appropriate drive select that drive (typically A:). using CD-ROM, insert into CD-ROM drive (typically D:). prompt, type following: a:/install.exe (diskette) d:/dos/install.exe (CD-ROM) Follow instructions your screen.
Xilinx
Menu
HW-130 Programmer
File
Options
Select File
Help
XC7372 Algorithm Socket Verify Blank Device Check Device Checksum String Create File Append Data File Version 1.00 HW-133-PC84
Device Design
Adapter
Display
Quantity Pass Fail Device
Checksum Checksum
Device
Secured
Program Device
Command Buttons
Load Device
Signature Exit
Cancel
Status
Selects
Device
programmed
X6034
Figure Main Screen (DOS) menus command buttons interface HW-130 Programmer. general, menu commands software configuration diagnostics, command buttons programmer operations. Refer online help detailed
1-14
Xilinx Development System
Getting Started
description menus command buttons.
Configuring Software
HW-130 software automatically configures programmer your host computer reliable communications. default ports that Workstation uses find HW130 programmer, listed Table 1-2. Once configured, communications settings saved selecting Save Settings from File menu. software cannot find programmer, dialog displayed with list possible causes. Check that have read write permissions serial ports workstation. Table Default Ports Platform Sun4 Solaris HP700 Default Ports Used COM1 COM2 COM3 COM4 ttya ttya ttya ttyb ttyb ttyb ttyb tt00 tty0 tt01 tty1
RS6000 ttya
Setting Communications Options Manually
Once configured HW-130 Programmer software operates standard baud rates that include: Auto, 1200, 2400, 4800, 9600, 19200, 38400 baud. HW-130 Programmer software change baud rate communications port necessary. Note: version also supports 57600 115200 baud rates. Select Options Communications display
HW-130 Programmer User Guide
1-15
HW-130 Programmer User Guide
Communications dialog box.
Figure Communications Dialog (Windows) Select baud rate want. Select port type want. serial port options include AUTO, COM1, COM2, COM3, COM4. Workstation, serial port options include AUTO, ttya, ttyb user defined serial device. workstations, serial port options include AUTO, ttya, ttyb, tty00, tty01 user defined serial device. workstations, serial port options include AUTO, ttya, ttyb, tty0, tty1, user defined serial device. software displays only port options ports available your workstation. AUTO default. default, software searches programmer through available communications ports negotiates highest available baud rate between workstation programmer. workstation, select port type want specifying path device name that port Serial Port Device name Communications dialog box, example, /dev/ttya. From specified serial port box, also access different serial device drivers, provided your system configured them. Click button exit from this window. save these settings selecting Save Settings File menu. These settings will used with your next programming session.
1-16
Xilinx Development System
Getting Started
Selecting Commands Dialog Options
choose menu item option dialog box, mouse keyboard.
Using Mouse
following guidelines when using mouse select menu options dialog options. Move mouse pointer over toolbar button menu name click left mouse button select object. clicked toolbar button, list dialog appears appropriate. clicked menu, menu options displayed. Click option want use. exit list dialog without selecting anything, press Cancel. exit dialog also double-click upper left corner dialog box.
Using Keyboard
following guidelines when using keyboard select menu options dialog options. choose menu item, first select menu pressing highlighted letter that menu. Note: workstation, function instead select first menu, then arrow keys select other menus. menu options displayed. arrow keys scroll down list menu list items. status describes option that currently highlighted. Press Enter when option want highlighted type underlined letter menu item name. exit list dialog without selecting anything, press Escape position cursor Cancel button press Enter key.
HW-130 Programmer User Guide
1-17
HW-130 Programmer User Guide
quick keys also supported Windows UNIX. select programmer operation, press appropriate quick key. Refer "Keyboard Reference" appendix complete list keyboard commands programmer quick keys.
Invoking Help
There several ways getting Help from HW-130 program.
help from main screen, select Contents option Help menu. help from dialog boxes, click Help button located these dialog boxes. Alternatively, AltH combination access help page that dialog box. information about menu commands, highlight menu option press key. help page corresponding menu option displayed when release key.
1-18
Xilinx Development System
HW-130 Programmer User Guide
Programmer Operations
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Chapter
Programmer Operations
This chapter describes programmer procedures available HW-130 Programmer. Before attempting programmer operations included this chapter, verify that device type other device-related criteria correct. saved settings previous programming session, software uses last-used communications port, baud rate, sound options when execute hw130.exe program. These settings stored hw130.ini file.
Programming Quickstart
following figure outlines steps required program device.
Step Select device type program. algorithm downloaded same time. Step Select design program into device. file checksum displayed after file loaded. Step Enter quantity devices program. default Step Select this button initiate programming sequence. This step includes blank check verification. device checksum updated after completion programming.
Figure Main Screen (Windows UNIX)
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Xilinx File
Step Select device type program. algorithm downloaded same time. Step Select design program into device. file checksum displayed after file loaded. Step Enter quantity devices program. default Step Select this button initiate programming sequence. This step includes blank check verification. device checksum updated after completion programming.
HW-130 Programmer
Options
Select File
Help
XC7372 Algorithm Socket Verify Blank Device Check Device Checksum String Create File Append Data File Version 1.00 HW-133-PC84
Device Design Quantity Pass Fail Device
Adapter
Checksum Checksum
Device
Secured
Program Device Load Device
Signature Exit
Cancel Selects Device programmed
X6034
Figure Main Screen (DOS) Note: Throughout this section, quick keys indicated next programmer operations. summary quick keys them available "Keyboard Reference" appendix.
Specifying Device (Ctrl-D)
specify device, Select Device command follow these instructions. Install appropriate adapter device selected programmed. Refer Figure illustration showing place adapter programmer. Note: have installed wrong adapter selected device, error message appears when begin operation. Select Select Device command from File menu click Select Device toolbar button shown Figure 2-3.
Xilinx Development System
Programmer Operations
Figure Select Device Toolbar Button After select device, software automatically downloads corresponding device algorithm into memory HW-130 Programmer. status marks progress download operation.
Figure Device Selection Dialog
Specifying Design (Ctrl-F)
Before programming device, must specify design file download programmer memory. Select design selecting Open File command from File menu clicking Select Design toolbar button displayed Figure 2-5.
Figure Select Design Toolbar Button Open File dialog displayed shown Figure 2-6.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Figure Open File Dialog Specify drive, directory, file name design download. specify file formats listed Table List Files Type locate files file type want. Table Supported File Formats Format SPROM EPLD/CPLD Description Intel MCS-86 format (preferred default) Motorola EXORmacs format Tektronix TEKHEX format Extended Intel format JEDEC format
Note: HW-130 programmer will automatically give user correct format device selected. Some formats listed applicable devices particular family. information generate these files using Xilinx tools, refer XACT development system documentation. Click button accept selections.
Xilinx Development System
Programmer Operations
design file that specify downloaded memory HW-130 Programmer when click Design File button. File Checksum field updated with checksum downloaded file. Note: XC1700 design does targeted device, message displayed, informing that your design file large selected device. this case, must select larger device your design.
Specifying Profile
Profile command define information programming session save file. store setup information selected device, such specific design file, secure option, Reset Polarity. When select profile, automatically sets programmer desired conditions, with intervention your part. Profile accessible time during programming session from File menu from toolbar, enabling load preset profile.
Figure Load Profile Toolbar Button
Creating Profile
create profile, follow these instructions: Select Profile Create from File menu. Select device from Device List. Select Secure Device(s) Reset Polarity Active High, Reset Polarity Active Low, depending device selected. Click Select design file from Open File dialog box. Click after choosing correct file. dialog appears, displaying items that selected
HW-130 Programmer User Guide
HW-130 Programmer User Guide
include your profile. everything correct, click Change button modify incorrect information. software prompts choose profile name. Select file name click profiles have .pro extension.
Loading Profile
load profile, follow these instructions: Select Profile Load from File menu. Locate profile want. Double-click profile wish load.
Deleting Profile
delete profile, follow these instructions: Select Profile Delete from File menu. Locate profile want. Double-click profile delete. software prompts confirm that this file that wish delete. click correct file, click Cancel reselect.
Programming Device (Ctrl-P)
Program Device command program more devices. This command available only have specified device. This procedure also assumes have specified design file. Specify number devices program Quantity field HW-130 display. Select Program Device command from Options menu click Program Device toolbar button shown Figure 2-8.
Figure Program Device Toolbar Button
Xilinx Development System
Programmer Operations
software prompts input Reset Polarity Device Secured field depending device selected. options available devices.
Select High active Reset. High default. Select desired security. Depending device selected, several security; options available: Select disable security feature (the default). Select activate security feature. Select Secure Only secure previously programmed device. Note: some other devices several other security alternatives also selected: Read Secure This option disables device from being read, still permits erased reprogrammed. Write Secure This option allows device read, disables ability erase reprogram. Read Write Secure This invokes both types security listed above. Once secured, only signature string read.
Note: only need answer these questions once during programming, regardless quantity selected. configure programmer opening profile, prompted answer these questions since these settings part profile. specified device quantity more than message "Please Insert Device Socket" displayed, where current device maximum quantity selected. Place first device wish program socket adapter. program next devices, also initiate program command pressing programmer pushbutton. Check status view progress programming operation. After programming device, software updates Pass/Fail Device Checksum fields display.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Repeat previous step until have programmed devices. When program device, software completes following operations: Blank Check, Program, Verify, Checksum calculation.
Loading Device (Ctrl-L)
Load Master Device command load contents master device into programmer memory. Place device wish load socket adapter. After inserting device socket, select Load Master Device command from Options menu click Load Master toolbar button shown Figure 2-9.
Figure Load Master Toolbar Button software reads device copies contents into programmer memory. device checksum field device reset polarity field certain devices updated. data program other devices verify other programmed devices against
Verifying Device (Ctrl-V)
Verify Device command compare programmed device data pattern that already been loaded into programmer memory.
Figure 2-10 Verify Device Toolbar Button
Comparing Device File
compare programmed device against file.
Xilinx Development System
Programmer Operations
After programming device, select Verify Device command from Options menu click Verify Device toolbar button. software compares device file that loaded into programmer memory. Note: programmer memory empty, prompted select file downloaded into programmer memory before software verify device. device matches file, software updates Device Checksum Pass display. there differences, error message displayed. Repeat previous step until have verified copies specified device type either clicking Verify Device toolbar button pressing programmer pushbutton.
Comparing Device Another
load device pattern programmer memory ready software compare another device. Load Master toolbar button this. After inserting programmed device socket, select Load Master load that device pattern into programmer memory. Remove device from socket insert device against which want verify data. Select Verify Device command from Options menu click Verify Device toolbar button shown Figure 210.
Checking Blank Device (Ctrl-B)
Blank Check command ensure that device socket blank. After inserting device socket, select Blank Check Device command from Options menu click Blank
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Check toolbar button shown Figure 2-11.
Figure 2-11 Blank Check Toolbar Button software executes Blank Check command. device blank, message "Failed Blank Check" displayed. Otherwise, software updates display. Repeat previous step until have checked devices either clicking Blank Check toolbar button pressing programmer push-button.
Calculating Device Checksum (Ctrl-K)
Device Checksum command calculate checksum contents device socket. method used calculate checksum ignores non-data bits, such manufacturer device reset polarity. After inserting device socket, select Device Checksum command from Options menu click Device Checksum toolbar button.
Figure 2-12 Device Checksum Toolbar Button software executes Device Checksum command updates display. Repeat previous step until have calculated checksum devices either clicking Device Checksum toolbar button pressing programmer push-button.
Viewing Signature String (Ctrl-S)
Signature String command retrieve signature device. signature string consists eight alphanumeric characters
2-10
Xilinx Development System
Programmer Operations
used identify designs devices. specify this string into design file when file compiled. After inserting device socket, select Signature String command from Options menu click Signature String toolbar button shown Figure 2-13.
Figure 2-13 Signature String Toolbar Button Device Signature message displayed, indicating signature device. Repeat previous step until have read signatures devices either clicking Signature String toolbar button pressing programmer push-button.
Saving Programmer Memory Contents File (Ctrl-C)
Save File command save programmer memory contents output file. Note: command equivalent this function Create File button. Select Save File command from File menu click Save File toolbar button.
Figure 2-14 Save File Toolbar Button software displays Save File dialog specify file name location that will store file. format output file programming file formats. Ensure specify file extension when enter file name.
HW-130 Programmer User Guide
2-11
HW-130 Programmer User Guide
Appending Data (Ctrl-A)
Append Data command create file from existing files download combined file into programmer memory. Thereafter, file program device. Append Data button available only have specified device with this feature. Select Append Data command from File menu click Append Data toolbar button.
Figure 2-15 Append Data Toolbar Button Original Design File dialog displayed specify original file which will another file. Specify design explained beginning this chapter. software then displays Design Appended dialog specify design file added original design file. software appends data original file downloads combined design file programmer memory. this point, dialog displayed prompting select three options: Program, Save File, Cancel. Select option corresponding task want perform. information Program Save File options, refer procedures "Programming Device" "Saving Programmer Memory Contents File," also covered this chapter. software updates display with file checksum combined design file.
2-12
Xilinx Development System
HW-130 Programmer User Guide
Command Reference
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Chapter
Command Reference
This chapter presents commands available HW-130 Programmer. commands listed alphabetical order. When applicable, corresponding toolbar button included command description.
Menus
HW-130 Programmer three menus, which described following sections.
File Menu
File menu contains commands select device type design file. also includes commands create files, save programmer settings, profile, exit program. access File menu with keyboard press letter underlined menu name, while holding down key. Press underlined letter corresponding menu option want. commands File menu following: Select Device Open File Save File Append Data Save Settings Selects device type. Opens design file. Saves contents programmer memory file. Adds file another file. Saves programmer communications port baud rate settings. sound options. Loads existing profile, creates deletes profile. Prints specific information.
Profile Summary
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Exit
Exits HW-130 software.
Options Menu
Options menu includes commands execute programmer commands commands configure diagnose programmer. access this menu with keyboard press letter underlined menu name, while holding down key. Press underlined letter corresponding menu option want. Program Device Verify Device Programs selected device with selected design. Compares programmed device file currently loaded programmer memory. Loads contents programmed device into programmer memory. Checks that device blank. Retrieves signature devices. Checks device checksum. Measures voltage current each power supply. Provides several diagnostics loops check port, memory, drivers, supply voltage. Resets programmer. Turns autohandler mode off. Sets port baud rate HW-130 Programmer. Sets sound off.
Load Master Blank Check Device Signature String Device Checksum Auto-Calibration Diagnostics
Reset Programmer Autohandler Mode Communications Sound
Help Menu
Help menu contains commands that enable access online help HW-130 Programmer. access this menu with keyboard press letter underlined menu name, while holding down key. Press underlined letter corresponding menu option want. Contents About HW-130 Lists online help topics. Displays program version.
Xilinx Development System
Command Reference
Alphabetical Listing Commands
This section lists menu commands HW-130 software program.
About HW-130 (Help Menu)
this command display program version, shown Figure 3-1.
Figure About HW-130 Dialog
Append Data (File Menu)
this command combine files download them into programmer memory. then save data into file that data program devices. This command available after have specified device type.
Figure Append Data Toolbar Button
Auto-Calibration (Options Menu)
this command measure voltage current each power supply. When select this command, Auto-Calibration dialog opened showing status available supplies programmer. must calibration adapter this operation.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Autohandler Mode (Options Menu)
this command turn autohandler mode off. When turn autohandler mode, Handler Mode field added bottom right-hand side display. have installed auto-handler, this command should off.
Handler Mode
Figure Handler Mode
Blank Check Device (Options Menu)
this command check that device blank. This command available after have specified device type.
Figure Blank Check Toolbar Button
Communications (Options Menu)
this command port baud rate HW-130
Xilinx Development System
Command Reference
Programmer, necessary.
Figure Communications Dialog
Contents (Help Menu)
this command bring list help topics online help window.
Device Checksum (Options Menu)
this command check device checksum.This command available after have specified device type. After calculating device checksum, program updates appropriate field display: Pass operation successful, Fail operation failed. addition, Device Checksum field display reflects value.
Figure Device Checksum Toolbar Button checksum number programmed device should match checksum file that used program device. following figure partial view display that updated
HW-130 Programmer User Guide
HW-130 Programmer User Guide
with checksum number programmed device.
Device Checksum
Figure Device Checksum Programmed Device
Diagnostics (Options Menu)
this command execute diagnostics loops check port, memory, drivers, supply voltage your programmer. Select test clicking radio button preceding test that want execute. Then press Execute button start test. more information, refer "Diagnostics Procedures" appendix.
Xilinx Development System
Command Reference
Figure Diagnostics Dialog
Exit (File Menu)
this command exit HW-130 Programmer window.
Load Master (Options Menu)
this command load contents programmed device into programmer memory. then data program another device. This command available after have specified device type.
Figure Load Master Toolbar Button After loading master device, program updates appropriate field display: Pass operation successful, Fail operation failed.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Summary (File Menu)
this command record specific information, such Number, Operator Name, Operator Number, other Information required. When printed, software automatically appends Time, Date, Operation Performed, Device Type, Algorithm Version, Profile Name applicable), Design File Name, File Checksum, Pass Fail Quantities. Note: This only applicable Windows.
Open File (File Menu)
this command open file will programming more devices.
Figure 3-10 Select Design Toolbar Button When open file, download into programmer memory. This command available after have specified device type.
Profile (File Menu)
profile consists device type, design file, device polarity security. this command load existing profile, create delete profile. Once have created profile, invoke whenever need load profile select Program command, will prompted enter device polarity security feature anymore.
Figure 3-11 Load Profile Toolbar Button
Program Device (Options Menu)
this command program more devices with selected design. This command available only have selected device
Xilinx Development System
Command Reference
type.
Figure 3-12 Program Device Toolbar Button program executes following operations: blank check, program, verify, device checksum. this command after using following commands that load design file into programmer memory: Open File, Load Profile, Append Data, Load Master. programming successful, program updates Pass field; otherwise, updates Fail field.
Reset Programmer (Options Menu)
this command reset programmer. This command equivalent turning programmer again.
Save File (File Menu)
this command save contents programmer memory file.
Figure 3-13 Save File Toolbar Button this command after using commands that load data programmer memory: Open File, Append Data, Load Master. Specify name file which data saved well file extension. file extension .tek, .mcs, .exo, .prg .jed represents file format which save file.
Save Settings (File Menu)
this command save programmer settings, such port, baud rate, sound options. data saved hw130.ini.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
using version program, also save color settings that specified.
Select Device (File Menu)
this command select type device want program. When select device, program downloads device algorithm into programmer memory.
Figure 3-14 Select Device Toolbar Button
Signature String (Options Menu)
this command display signature EPLD/CPLD devices.
Figure 3-15 Signature String Toolbar Button
Sound (Options Menu)
this command sound off. When sound program emits sound whenever encounter error.
Verify Device (Options Menu)
this command compare programmed device file currently loaded programmer memory. This command available only have selected device.
Figure 3-16 Verify Device Toolbar Button this command verify that your device successfully programmed. also this command compare device another. After programming device, replace current device
3-10
Xilinx Development System
Command Reference
with device that want evaluate click Verify. verification successful, Pass field updated programmer display; otherwise program updates Fail field.
HW-130 Programmer User Guide
3-11
HW-130 Programmer User Guide
3-12
Xilinx Development System
HW-130 Programmer User Guide
Keyboard Reference
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Appendix
Keyboard Reference
This appendix summarizes keyboard commands navigate programmer display. also lists keyboard commands activate programmer commands.
Keyboard Commands
following keyboard commands navigate select objects screen. Table Summary Keyboard Commands Shift-Tab Enter Arrow keys Alt-Character Ctrl-Character Action Traverse objects forward highlight them. Traverse objects backward highlight them. Activate selection button highlighted item list. Scroll down inside selection boxes menus. Navigate from menu another. Select menu Workstation Select menu workstation. Select programming quick operation. Unselect menu exit Help window. Abort current operation.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Quick-Key Reference
select command buttons, press appropriate quick from list displayed Table A-2. table lists programmer quick keys alternative command buttons. select quick key, locate programmer operation corresponding quick Table A-2. Hold down Ctrl while press other indicated. example, type Ctrl-P select Program Device button. Table Programming Quick Keys Programmer Operation Device Select Design File Quantity Program Device Load Device Verify Device Blank Check Device Checksum Signature String Create File Append Data Cancel Exit Ctrl-D Ctrl-F Ctrl-Q Ctrl-P Ctrl-L Ctrl-V Ctrl-B Ctrl-K Ctrl-S Ctrl-C Ctrl-A Ctrl-X Quick
Xilinx Development System
HW-130 Programmer User Guide
Diagnostics Procedures
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Appendix
Diagnostics Procedures
This appendix explains monitor calibration HW-130 Programmer diagnostic tests.
Auto-Calibration
HW-130 Programmer automatically calibrates itself whenever turn power Reset Programmer command. However, HW-130 provides capability monitor operation calibration circuitry. calibration adapter shown following figure required.
PVpp PVcc PVsp
CLOSED OPEN
HW-130-CAL
PVpp PVcc
PVsp
X4922
Figure Calibration Adapter
HW-130 Programmer User Guide
HW-130 Programmer User Guide
start auto-calibration, follow these steps after turning power your programmer: Install HW-130-CAL calibration adapter, shown Figure B-1. calibration adapter includes test points measuring voltage current levels programmable power supplies. Select Options Auto-Calibration. dialog opened showing status available supplies. Note: Depending version hardware, PVsp displayed. measure voltage current each power supply, provided switches (see Figure B-2). closed position, switches adapter connect load resistors their respective power supplies. Open switch measure current that corresponds supply being measured.
HW-130 Calibration Adapter
PVxx
X4965
Figure Measuring Voltage Current measure current, open switch that corresponds supply being measured connect external current measuring equipment adapter, shown preceding figure. HW-130 results that displayed AutoCalibration dialog should agree with value measured current measuring equipment following percentages:
PVcc should should ±10%
Xilinx Development System
Diagnostics Procedures
PVpp should should ±10% PVsp should should ±10%
Note: results only good equipment used measure programmer's results. Ensure that your meters calibrated accurate. Note: PVsp available your version hardware. Click Execute button. programmer firmware executes calibration routines. results displayed Auto-Calibration dialog box.
Diagnostics
diagnostics routines consist software loops that exercise various functional blocks within programmer, allowing verify that blocks operating properly. following guidelines select test: Select Options Diagnostics display Diagnostics dialog box. Select diagnostic loop run. Click Execute button start test. Check Diagnostics Status view results test. Note: Once select execute diagnostic loop, test
HW-130 Programmer User Guide
HW-130 Programmer User Guide
continues until cancel clicking Cancel button.
Figure Diagnostics Dialog
RS-232 Serial Communications Test
This test allows verify RS-232 port host system various baud rates. Select RS-232 Serial Communications from Diagnostics dialog box. Communications dialog opened. Specify baud rate communications port. Click close Communications dialog start test. host HW-130 Programmer transmit receive data baud rate until cancel test. Each time complete test, informed whether test successful not. message displayed communication error occurs.
Xilinx Development System
Diagnostics Procedures
Memory Test
This test writes non-repeating data pattern HW-130 Programmer data memory ensure that every location accessed that both logic written read. Each time complete test, informed whether test successful not. test fails, Diagnostics Status also displays which memory bank failed.
Driver Clock Test
Driver test exercises every address, data, clock signal that connects socket adapter interface connector. this test, install socket adapter with device socket. Select Driver Clock Test from Options Diagnostics menu. Click Execute. Note: stop test, click Cancel. address, data, clock signals driven between CMOS logic approximately kHz. view them using oscilloscope probe appropriate pins adapter socket. Refer device data sheet pin-out information. There Pass/Fail conditions this test. Warning: Exercise caution when probing socket pins avoid damaging them. When calibration adapter shown Figure B-1, signals connected such that HW-130 Programmer able test pins both input output signals. programmer will display errors that occur continuously toggle signals approximate rate KHz.
Programmable Supply Voltage Loop
HW-130 Programmer programmable power supplies called PVcc PVpp, which used program devices. this test, install socket adapter with device
HW-130 Programmer User Guide
HW-130 Programmer User Guide
socket. Select Programmable Supply Voltage from Options Diagnostics menu. Click Execute. loop causes supplies step between four voltage levels shown Figure B-4. view waveforms using oscilloscope probe appropriate pins adapter socket. Refer device data sheet pin-out information. There Pass/Fail conditions this test. Warning: Exercise caution when probing socket pins avoid damaging them.
Cycle
LEVEL (Volts)
TIME (ms)
Cycle
15.0 10.0
LEVEL (Volts)
TIME (ms)
X6043
Figure Programmable Supply Test Levels
Xilinx Development System
HW-130 Programmer User Guide
Automation
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Appendix
Automation
This chapter describes setup operation HW-130 programmer conjunction with autohandling equipment.
Selecting Autohandler Mode
select autohandler mode operation, follow these instructions. Connect HW-130 programmer autohandler. Refer Figure appropriate interface timing Figure signal locations.
START TEST
Start Pulse (typ)
PASS SIGNAL
Handler Binning Occurs (Pass)
FAIL SIGNAL
Handler Binning Occurs (Fail)
X6616
Figure Handler Timing HW-130 Programmer Request assistance from autohandler manufacturer proper connection (both mechanical well electrical).
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Description Start Test Pass Signal Fail Signal Ground
A15-A31
X6615
Figure HW-130 96-Pin Connector (Top View) Select Options Autohandler main screen indicates that autohandler
Programmer Operation
This section summarizes instructions using programmer conjunction with autohandler. Please refer "Programming Operations" chapter details individual procedures. Specify device pressing Device Select button main screen. Alternatively, select profile. profile loads device type, polarity security feature, design into programmer memory. Click Select Design toolbar button open design. Note: wish load master device, before selecting autohandler mode. Specify device quantity program Quantity field. quantity only needs specified programming. Select desired programmer operation, Program Device, Verify Device, Blank Check pressing appropriate toolbar button HW-130 Programmer main screen. Note: While autohandler mode, only Program Device, Verify Device, Blank Check commands functional. other commands, must autohandler mode.
Xilinx Development System
Automation
programmer ready-state, waiting Start-ofTest signal from autohandler. Follow instructions from autohandler manufacturer operate autohandler properly.
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Xilinx Development System
HW-130 Programmer User Guide
Wiring Conventions
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Appendix
Wiring Conventions
This appendix includes wiring information that hardware purposes.
Power Cord
following illustration indicates wiring HW-130 Programmer power cord. following illustration shows commonly used wiring convention U.S.A. power cord. wire colors wiring guide.
Hot/Live (Black) Ground (Green) Neutral (White) colors specified this diagram typical. Neutral (White) Ground (Green) Hot/Live (Black)
X4972
Figure Typical U.S.A. Power Cord
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Serial Connector
following illustration shows serial port connections.
Connector (Female)
X6044
Figure HW-130 Serial Connector
Xilinx Development System
HW-130 Programmer User Guide
Index
HW-130 Programmer User Guide
Printed U.S.A.
HW-130 Programmer User Guide
Xilinx Development System
Index
adapter calibration adapter, socket adapter, appending data, 2-12 auto-calibration, autohandler mode programmer oeprations, setup instructions, automating programmer operations,
baud rate, 1-15 buttons. commands
calculating device checksum, 2-10 calibration adapter, checking blank device, command selection keyboard, 1-17, mouse, 1-17 commands also programmer procedures About HW-130 (Help menu), alphabetical list, Append Data (File menu), Auto-Calibration (Options menu), Autohandler Mode (Options menu) Blank Check Device (Options menu) Communications (Options menu), Contents (Help menu), Device Checksum (Options menu), Diagnostics (Options menu),
Exit (File menu), Load Master Device (Options menu) Open File (File menu), Profile (File menu), Program Device (Options menu), Reset Programmer, Reset Programmer (Options menu), Save File (File menu), Save Settings, 1-16 Save Settings (File menu), Select Device (File menu), 3-10 Signature String (Options menu), 3-10 Sound (Options menu), 3-10 Verify Device (Options menu), 3-10 Communications dialog box, 1-16 communications port, 1-15 configuration software, 1-15
design selection, Device Secured field, Device Selection dialog box, device specification, diagnostics calibration adapter, measuring voltage current, memory test, driver clock test, procedures, programmable supply voltage, programmer blocks, RS-232 communications test, Diagnostics dialog box,
HW-130 Programmer User Guide
HW-130 Programmer User Guide
file formats,
hardware requirements, help, 1-14
installation requirements, software, installing adapter,
keyboard command summary, menu selection, 1-17 quick keys,
loading device,
main screen, 1-14, menu bar, 1-8, 1-13 menu selection keyboard, 1-17 mouse, 1-17 menus list commands,
loading profile, programmable supply test levels, programmer description, POST test, rear panel, resetting programmer, panel, programmer procedures appending data, 2-12 calculating device checksum, 2-10 checking blank device, loading master device, programming device, saving file, 2-11 selecting design, selecting device, specifying profile, verifying device, viewing signature string, 2-10 programming procedures, quickstart, programming device,
quantity, quick keys,
Open File dialog box,
Reset Polarity field, Reset Programmer command,
POST test, power cord wiring conventions, procedures diagnostics, programming, profile creating profile, deleting profile,
saving file, 2-11 serial connector wiring conventions, settings saving your settings, 1-16 software configuration, 1-15 installation, requirements,
Xilinx Development System
Index
software settings, 1-15 specifying profile, starting program, 1-7, 1-12 status bar, 1-9, 1-13
troubleshooting POST,
verifying device, against file, against another device, viewing signature string, 2-10
wiring conventions, power cord, serial connector,
HW-130 Programmer User Guide
HW-130 Programmer User Guide
Xilinx Development System

Other recent searches


WKI28XXS-20 - WKI28XXS-20   WKI28XXS-20 Datasheet
PT7706--3 - PT7706--3   PT7706--3 Datasheet
MPC9653 - MPC9653   MPC9653 Datasheet
MPC953 - MPC953   MPC953 Datasheet
MM1779 - MM1779   MM1779 Datasheet
MF431 - MF431   MF431 Datasheet
HMC412MS8G - HMC412MS8G   HMC412MS8G Datasheet
HC-36 - HC-36   HC-36 Datasheet
HC-43 - HC-43   HC-43 Datasheet
AT89STK-10 - AT89STK-10   AT89STK-10 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive