| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
DC/DC CONVERTERS VOLT INPUT HR300 SERIES WATT MODELS OU
Top Searches for this datasheet-40° +85°C operation input input HR301-2805) Fully Isolated Optocoupler feedback Fixed frequency, typical Topology Push-Pull Forward transient protection Inhibit function Indefinite short circuit protection Remote sense HR301-2805 model efficiency DC/DC CONVERTERS VOLT INPUT HR300 SERIES WATT MODELS OUTPUT SINGLE DUAL Size (max.): 2.720 1.350 0.505 inches (69.09 34.29 12.83 Section case dimensions. Weight: grams max. Screening: Standard only. Section screening description. DESCRIPTION HR300 SeriesDC/DC converters combine small size high reliability hybrid-based components, high efficiency switching regulators, isolation, regulation, noise characteristics linear regulators. SMALL SIZE RELIABILITY HR300 DC/DC converters thick-film hybrid manufacturing techniques smaller size, lighter weight higher reliability than converters produced with other circuit techniques. With footprint less than square inches inch height, HR300 converters reach power densities watts cubic inch. HR300 parts same manufacturing procedures quality controls that Interpoint applies converters built aerospace military applications. converters hermetically sealed metal packages that guaranteed maximum leak rate less than 10-3 atm-cc/sec. Short circuit protection provided through foldback current limiting. When output current reaches approximately 125% full rated load, output voltage begins reduce protect converter. converter sustain true short circuit condition indefinitely. HR300's flanged case facilitates removal heat provides mechanically secure mounting. full power operation indefinite short circuit protection system requirement, HR300 converter should mounted with efficient heat sink contact with mounting flange. Internal filters HR300 converters provide noise both input outputs. HR301 models, two-section filters limit output ripple voltage reflected input ripple current. HR302 models, single-section filters perform same function. maximum output regulation, HR301-2805 provided with external output voltage remote sense pins. Connecting remote sense pins load provides four-terminal voltage mode which eliminates adverse effects line resistance voltage drops. Remote sense pins left unconnected, cautions this data sheet. normal operation, remote sense pins should connected respective output pins. HIGH PERFORMANCE HR300 converters constant frequency pulse-width modulated switching regulator design operating forward mode with clock switching frequency kHz. Isolation achieved through transformer forward power circuit optocoupler feedback control loop. full load output power watts available over entire input range HR301-2805). dual output models, full power available from either output combined total watts. HR300's high efficiency maintained over entire input voltage range from approximately full load full load (see typical efficiency curves). INHIBIT FUNCTION inhibit provided allow logic input shut down converter. open circuit inhibit (pin allows normal operation. connection between inhibit input common (pin disables internal oscillator, shutting down output. inhibit open circuit voltage single output models, HR302-2812 HR302-2815. inhibit mode, approximately must sunk from inhibit pin. active open collector required activate inhibit function. B4-39 HR300 SERIES WATT ABSOLUTE MAXIMUM RATINGS Input Voltage HR301-2805) Output Power watts Lead Soldering Temperature lead) 300°C Storage Temperature Range (Case) -55°C +125°C DC/DC CONVERTERS INHIBIT Inhibit Open Collector Logic (output disabled) Inhibit current typical Referenced input common Logic high (output enabled) Open collector TYPICAL CHARACTERISTICS Output Voltage Temperature Coefficient ppm/°C typical Input Output Capacitance typical single output models typical HR302-2812 typical HR302-2815 Current Limit 125% full load, typical Isolation megohm minimum Conversion Frequency Inhibit Voltage (unit enabled) single output models HR302-2812 HR302-2815 RECOMMENDED OPERATING CONDITIONS Input Voltage Range continuous HR301-2805 msec transient Case Operating Temperature (Tc) -40°C +85°C full power Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE LINE REGULATION1 LOAD REGULATION2 INPUT VOLTAGE -40°C +85°C INPUT CURRENT -40°C +85°C MIN. MAX. LOAD FULL LOAD FULL TRANSIENT LOAD FULL LOAD INHIBITED INPUT RIPPLE CURRENT EFFICIENCY START-UP DELAY2 OVERSHOOT 1200 1500 CONDITIONS HR301-2805 4.95 5.05 30.0 1370 HR301-2812 11.88 12.12 30.0 1400 14.85 HR301-2815 15.15 30.0 1400 UNITS Notes HR301-2805, with remote sense pins connected load resistance between output pins load. output impedance power source required input realize this start-up time. less than full surge current available, start-up time will longer CAUTION Permanent damage HR301-2805 will result shorted ground. Damage also result disconnected from load during operation with remote sense leads connected load. remote sense pins connected load, output voltage HR301-2805 will rise approximately measured across pins B4-40 DC/DC CONVERTERS TRIPLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE CONDITION +VOUT VOUT OUTPUT CURRENT1 OUTPUT POWER1 OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION CROSS REGULATION2 -40°C +85°C LOAD FULL +VOUT VOUT INPUT VOLTAGE -40°C +85°C INPUT CURRENT CONTINUOUS TRANSIENT LOAD FULL LOAD INHIBITED DELAY3 OVERSHOOT 11.88 11.88 HR302-2812 12.0 12.0 1500 12.12 12.12 30.0 1350 HR302-2815 15.0 15.0 1500 15.15 15.15 30.0 1400 UNITS 14.85 14.85 HR300 SERIES WATT Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. INPUT RIPPLE CURRENT EFFICIENCY START-UP Notes full power available from either output providing total power does exceed watts. effect output voltage either output (held watts) when other output varied from watts. output impedance power source required input realize this start-up time. less than full surge current available, start-up time will longer Squared corner cover indicate one. Dual Output Positive Input connection Positive Output Output Common Negative Output connection Case Ground Inhibit Input Common Input Common HR301-2805 Positive Input Inhibit Sense Return Output Common Positive Output Positive Sense Case Ground connection connection Input Common Single Output Positive Input Inhibit connection Output Common Positive Output connection Case Ground connection connection Input Common BOTTOM VIEW HR300 Section case dimensions. FIGURE MODEL NUMBERING HR30 Base Model Number Outputs single, dual) Input Voltage Output Voltage B4-41 HR300 SERIES WATT DC/DC CONVERTERS Typical Performance Curves: 25°C Efficiency Output Power (Watts) Efficiency Efficiency Output Power (Watts) Output Power (Watts) HR301-2805 Efficiency FIGURE HR301-2812 Efficiency FIGURE HR302-2812 Efficiency FIGURE Input Voltage (Volts) Inupt Voltage (Volts) HR301-2812 HR301-2815 Efficiency HR302-2815 HR302-2812 Output Power (Watts) Output Power (Watts) Output Power (Watts) HR302-2815 Efficiency HR301-2812 HR301-2815 Line Dropout HR302-2812 HR302-2815 Line Dropout FIGURE FIGURE FIGURE B4-42 24421-009-DTS 2009 technical information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. HR300 Series trademark Interpoint. Copyright 1991 1999 Interpoint. rights reserved. CASE CASES case indicates CASE BOTTOM VIEW Figures configuration 1.350 (34.29) 2.720 (69.09) Flange Thickness: Cases Case Cases 0.060 (1.52) 0.073 (1.85) 0.067 +0.005/-0.007 (1.70 +0.13/-0.8) Materials Header Case Cold Rolled Steel/Nickel/Gold Cases Cold Rolled Steel/Nickel/Tin Cover Case Kovar/Nickel Case Cold Rolled Steel/Nickel/Tin Pins alloy (all cases) Case Series Triple compression glass seal Series Triple ceramic seal Cases compression glass seal Case dimensions inches (mm) Tolerance ±0.005 (0.13) three decimal places ±0.01 (0.2) decimal places unless otherwise specified CAUTION Heat from reflow wave soldering damage device. Solder pins individually with heat application exceeding 300°C seconds pin. FIGURE CASE MAXIMUM DIMENSIONS Note: Although every effort been made render case drawings actual size, variations printing process cause some distortion. Please refer numerical dimensions accuracy. B8-22 CASES BOTTOM VIEW CASE Flanged cases: Designator required Case Option position model number. FMD28-461 Filter (down-leaded): Screening Standard Solder Seal 1.173 (29.79 0.040 dia. (1.02) 0.673 (17.09) CASE Squared corner case indicate one. 0.162 (4.11) Solder Tip-off 0.173 (4.39) 0.000 0.000 0.25 (6.4) 0.210 (5.33) 0.000 0.170 (4.32) 1.370 (34.80) 0.505 (12.83) 1.770 (44.96) 1.980 (50.29) 0.162 (4.11) 1.980 (50.29) FIGURE CASE BOTTOM VIEW CASE Flanged cases: Designator required Case Option position model number Series Series only. Series, Series, Series: Screening Standard HR300 Series: screening options Solder Seal 1.173 (29.79 0.040 dia. (1.02) 0.673 (17.09) Squared corner case indicate one. Solder Tip-off 0.173 (4.39) 0.000 0.000 0.25 (6.4) 0.210 (5.33) 0.000 0.170 (4.32) 0.570 (14.48) 0.970 (24.64) 1.370 (34.80) 0.505 (12.83) 1.770 (44.96) FIGURE CASE B8-25 SCREENING PRODUCTS PRODUCTS TEST products) PRE-CAP INSPECTION Method 2017 FINAL ELECTRICAL TEST MIL-PRF-38534, Group Subgroups +25°C case HERMETICITY TESTING Gross Leak, 10-3) FINAL VISUAL INSPECTION Method 2009 STANDARD Test methods referenced MIL-STD-883 determined MILPRF-38534. Applies following products: HR700 Series HR300 Series HR150 Series HR120 Series HR40 Series C2-13 Other recent searchesXilinx - Xilinx Xilinx Datasheet XAPP210 - XAPP210 XAPP210 Datasheet Linear - Linear Linear Datasheet Feedback - Feedback Feedback Datasheet Shift - Shift Shift Datasheet Registers - Registers Registers Datasheet Virtex - Virtex Virtex Datasheet Devices - Devices Devices Datasheet application - application application Datasheet note - note note Datasheet RHRP3070 - RHRP3070 RHRP3070 Datasheet RHRP3080 - RHRP3080 RHRP3080 Datasheet RHRP3090 - RHRP3090 RHRP3090 Datasheet RHRP30100 - RHRP30100 RHRP30100 Datasheet LSE2040 - LSE2040 LSE2040 Datasheet HMC389LP4 - HMC389LP4 HMC389LP4 Datasheet DS7880 - DS7880 DS7880 Datasheet DS8880 - DS8880 DS8880 Datasheet AN-806 - AN-806 AN-806 Datasheet AN-808 - AN-808 AN-808 Datasheet 2SB1162 - 2SB1162 2SB1162 Datasheet
Privacy Policy | Disclaimer |