| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Size (max.): Weight: Screening: DC/DC CONVERTERS VOLT INPUT
Top Searches for this datasheet-55° +125°C operation input Fully isolated Optocoupler feedback Fixed frequency, typical (400 typ. output model) Topology Flyback transient protection Inhibit function Indefinite short circuit protection efficiency, W/in3 Size (max.): Weight: Screening: DC/DC CONVERTERS VOLT INPUT SERIES WATT MODELS OUTPUT SINGLE DUAL 1.075 1.075 0.270 inches (27.31 27.31 6.86 grams maximum. Standard, (Class DESCRIPTION Seriesof high frequency DC/DC converters offers standard performance power, military/aerospace grade DC/DC converters. parts provide watts output power over full military temperature range with efficiency. Thick-film hybrid techniques provide military/aerospace reliability levels optimum miniaturization. hermetically sealed case only 1.075 1.075 inches with height only 0.270 inches. Power density Series parts watts cubic inch. Series' small size, height, hermetically sealed metal enclosures make them ideal military, aerospace other high reliability applications. Units available with standard, screening, "ES", fully compliant "883" screening. page screening options descriptions. WIDE VOLTAGE RANGE converters designed provide full power operation over full voltage range. Operation below volts, including MIL-STD-704E emergency power conditions possible with derated power. Please refer line dropout graphs (Figures details. voltage lockout feature keeps converter shutdown below approximately ensure smooth initialization. IMPROVED DYNAMIC RESPONSE feed-forward compensation system provides excellent dynamic response noise rejection. Audio rejection typically minimum maximum step line transient response typically less than INHIBIT FUNCTION converters provide open collector-compatible inhibit feature that used disable internal switching inhibit unit's output. Inhibiting this manner results standby current, generation switching noise. converter inhibited when compatible (0.8 applied inhibit pin. unit enabled when pin, which internally connected pull-up resistor, left unconnected connected open collector gate. open circuit output voltage associated with inhibit inhibit mode, maximum must sunk from inhibit pin. CONVERTER DESIGN converters switching regulators that flyback converter design with constant switching frequency kHz. They regulated, isolated units using pulse width modulated topology built high reliability thick-film hybrids. Isolation between input output circuits provided with transformer forward power path optical link feedback control loop. Excellent input line transient response audio rejection achieved advanced feed-forward compensation technique. Negative output regulation maintained tightly coupled magnetics. watts, total output power, available from either output, provided that opposite output simultaneously carrying total power. Each output must carry minimum total output power order maintain specified regulation negative output. Predictable current limit accomplished direct monitoring output load current, which results constant current output above overload point. Internal input output filters eliminate need external capacitors. UNDERVOLTAGE LOCKOUT TRANSIENT PROTECTION Undervoltage lockout helps keep system current levels during initialization re-start operations. They withstand short term transients volts without damage. SERIES WATT ABSOLUTE MAXIMUM RATINGS Input Voltage Output Power watts Lead Soldering Temperature lead) 300°C Storage Temperature Range (Case) -65°C +135°C DC/DC CONVERTERS INHIBIT Inhibit Open Collector Logic (output disabled) Logic voltage Inhibit current Referenced input common Logic high (output enabled) Open collector TYPICAL CHARACTERISTICS Output Voltage Temperature Coefficient ppm/°C typical Input Output Capacitance typical Isolation megohm minimum Audio Rejection typical Conversion Frequency typical (400 model) min, min, model Inhibit Voltage (unit enabled) RECOMMENDED OPERATING CONDITIONS Input Voltage Range continuous msec transient Case Operating Temperature (Tc) -55°C +125°C full power -55°C +135°C absolute Derating Output Power/Current (Tc) Linearly from 100% 125°C 135°C Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER CONDITIONS OUTPUT VOLTAGE -55°C +125°C OUTPUT CURRENT -55°C +125°C OUTPUT POWER OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION INPUT VOLTAGE LOAD FULL INPUT CURRENT -55°C +125°C INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT3, SHORT CIRCUIT STEP LOAD RESPONSE4, STEP LINE RESPONSE4, -55°C +125°C -55°C +125°C LOAD FULL -55°C +125°C -55°C +125°C CONTINUOUS TRANSIENT LOAD FULL LOAD INHIBITED -55°C +125°C POWER DISSIPATION RECOVERY 100% TRANSIENT RECOVERY TRANSIENT RECOVERY START-UP DELAY OVERSHOOT 12.5 MSA2805S MSA285R2S MSA2812S MSA2815S 4.95 5.00 5.05 5.15 5.20 5.25 11.88 12.00 12.12 14.85 15.00 15.15 1000 MSA2860S1 59.1 60.00 60.9 UNITS Notes MSA2860S specifications 25°Tc only, contact your Interpoint representative more information over temperature specs. Line regulation 2805S models 125°C (case) (max). Indefinite short circuit protection guaranteed above 125°C (case). Recovery time measured from application transient point which VOUT within VOUT final value. Transition time >10µs. DC/DC CONVERTERS DUAL OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT1 OUTPUT POWER1 OUTPUT RIPPLE VOLT. LINE REGULATION CONDITIONS +VOUT -VOUT -55°C +125°C -55°C +125°C -55°C +125°C +VOUT -VOUT LOAD REGULATION LOAD FULL -55°C +125°C +VOUT -VOUT CROSS REGULATION2 INPUT VOLTAGE -55°C +125° INPUT CURRENT -55°C +125°C INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT3, LOAD FULL ~CONTINUOUS TRANSIENT msec LOAD FULL LOAD INHIBITED -55°C +125°C POWER DISSIPATION SHORT CIRCUIT RECOVERY 100% BALANCED TRANSIENT RECOVERY STEP LINE RESP.4, TRANSIENT RECOVERY DELAY OVERSHOOT 4.95 2805D 5.00 ±500 5.05 MSA2812D 11.88 11.76 12.00 12.00 ±208 12.12 12.24 14.85 14.70 SERIES WATT MSA2815D 15.15 15.30 UNITS Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. 15.00 15.00 ±167 ±150 ±750 ±500 1200 1200 ±300 ±750 ±125 ±125 1000 ±300 ±150 ±100 ±750 1250 ±375 ±250 2000 STEP LOAD RESPONSE4, START-UP Notes watts (80% full power) available from either output providing opposite output carrying total power. Shows regulation effect minus output during defined cross loading conditions. Figures Indefinite short circuit protection guaranteed above 125°C (case). Recovery time measured from application transient point which VOUT within VOUT final value. Transition time >10µs. SERIES WATT DC/DC CONVERTERS Single Output Positive Output Output Common connection connection Inhibit Positive Input Input Common Case Ground Dual Output Positive Output Output Common Negative Output connection Inhibit Positive Input Input Common Case Ground Squared corner package indicate one. BOTTOM VIEW page dimensions. FIGURE BOTTOM VIEW NUMBERS MODEL NUMBERING Base Model Input Voltage Output Voltage decimal point, Vout) Number Outputs single, dual) Screening (Standard screening designator this position.) STANDARD MICROCIRCUIT DRAWING (SMD) 5962-9309201HXC PROCESS 5962-9309301HXC 5962-9309401HXC 5962-0052201HXC 5962-9308901HXC 5962-9309001HXC SERIES SIMILAR PART MSA2805S/883 MSA285R2S/883 MSA2812S/883 MSA2815S/883 MSA2860S/883 MSA2812D/883 MSA2815D/883 exact specifications product, refer drawing. Call your Interpoint representative status releases. "883" suffix indicates similar part. SMDs downloaded from: DC/DC CONVERTERS SERIES WATT Typical Performance Curves: 25°C Vin, 100% load, unless otherwise specified. EFFICIENCY EFFICIENCY EFFICIENCY OUTPUT POWER (Watts) MSA2805S EFFICIENCY OUTPUT POWER (Watts) OUTPUT POWER (Watts) MSA2812S EFFICIENCY MSA2815S EFFICIENCY FIGURE FIGURE FIGURE ATTENUATION (dB) 20V/div. EFFICIENCY 20mV/div. VOUT OUTPUT POWER (Watts) FREQUENCY (kHz) 100µs/div MSA2815D EFFICIENCY SERIES AUDIO REJECTION MSA2805S STEP LINE RESPONSE FIGURE FIGURE FIGURE 100% 100% 20V/div. 1V/div. 50mV/div. 50mV/div. 100% 100% VOUT 100µs/div 100% 100µs/div 100% MSA2805S TURN-ON INTO LOAD MSA2805S STEP LOAD RESPONSE MSA2805S STEP LOAD RESPONSE FIGURE FIGURE FIGURE 20V/div. -POUT=2.5W -POUT=0.5W 100mV/div. 100mV/div. +VOUT -VOUT 200mV/div. 200µs/div 100µs/div 50%) 200µs/div MSA2815D INPUT STEP LINE RESPONSE MSA2815D STEP LOAD RESPONSE MSA2815D STEP LOAD RESPONSE FIGURE FIGURE FIGURE SERIES WATT DC/DC CONVERTERS Typical Performance Curves: 25°C Vin, 100% load, unless otherwise specified. -VOUT VOLTAGE CHANGE -VOUT VOLTAGE CHANGE 90/10 70/30 50/50 30/70 10/90 2815D 2812D COND 2812D COND 2815D 2812D 20V/div. 5V/div. +VOUT -VOUT 500µs/div MSA2815D TURN-ON INTO LOAD OUTPUT LOAD (+VOUT -VOUT 90-10% LOAD 10-90% LOAD DUAL CROSS REGULATION OUTPUT LOAD COND. LOAD COND. LOAD DUAL CROSS REGULATION FIGURE FIGURE FIGURE MSA2805S INPUT VOLTAGE (Volts) MSA2812S INPUT VOLTAGE (Volts) MSA2815D MSA2815S MSA2812D OUTPUT POWER (Watts) DROP OUTPUT POWER (Watts) DROP LINE DROPOUT LOAD LINE DROPOUT LOAD FIGURE FIGURE DC/DC CONVERTERS case indicates Materials Header Cold Rolled Steel/Nickel/Gold Cover Cold Rolled Steel/Nickel Pins Copper/Nickel/Gold compression glass seal 1.075 (27.31) Case dimensions inches (mm) Tolerance ±0.005 (0.13) three decimal places ±0.01 (0.3) decimal places unless otherwise specified CAUTION Heat from reflow wave soldering damage device. Solder pins individually with heat application exceeding 300°C seconds pin. SERIES WATT CASE BOTTOM VIEW Figure configurations. 1.075 (27.31) FIGURE CASE MAXIMUM DIMENSIONS BOTTOM VIEW CASE Series: Screening Standard, Seam Seal Projection Weld 0.932 (23.67) 0.025 (0.64) dia. Squared corner case indicate one. 0.132 (3.35) 0.000 0.000 0.270 max. (6.86) 0.205 ±0.010 (5.21 ±0.25) 0.000 0.205 ±0.010 (5.21 ±0.25) 0.270 max. (6.86) 0.000 0.132 (3.35) 0.332 (8.43) 0.532 (13.51) 0.732 (18.59) FIGURE CASE Note: Although every effort been made render case drawings actual size, variations printing process cause some distortion. Please refer numerical dimensions accuracy. 0.932 (23.67) SERIES WATT TEST (125°C Products) PRE-CAP INSPECTION Method 2017, 2032 DC/DC CONVERTERS ENVIRONMENTAL SCREENING STANDARD /883 (Class TEMPERATURE CYCLE times) Method 1010, Cond. -65°C 150°C Method 1010, Cond. -55°C 125°C CONSTANT ACCELERATION Method 2001, 3000 Method 2001, BURN-IN Method 1015, hours 125°C hours 125°C case (typical) FINAL ELECTRICAL TEST MIL-PRF-38534, Group Subgroups through -55°C, +25°C, +125°C Subgroups +25°C case HERMETICITY TESTING Fine Leak, Method 1014, Cond. Gross Leak, Method 1014, Cond. Gross Leak, 10-3) FINAL VISUAL INSPECTION Method 2009 Test methods referenced MIL-STD-883 determined MIL-PRF-38534. *883 products built with element evaluated components 100% tested guaranteed over full military temperature range -55°C +125°C. Contact Information: Interpoint Headquarters Phone: 1-800-822-8782 +425-882-3100 Email: power@intp.com www.interpoint.com Interpoint Phone: +44-1252-815511 Email: poweruk@intp.com Interpoint France Phone: +33-134285455 Email: powerfr@intp.com 22021-001-DTS This revision supercedes previous releases. technical information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. Series trademark Interpoint. Copyright 1994 2001 Interpoint Corporation. rights reserved. Other recent searchesVN5160S-E - VN5160S-E VN5160S-E Datasheet TUSB1210 - TUSB1210 TUSB1210 Datasheet PI74ST1G00 - PI74ST1G00 PI74ST1G00 Datasheet MEPUM10006-J10 - MEPUM10006-J10 MEPUM10006-J10 Datasheet LQ6RA01 - LQ6RA01 LQ6RA01 Datasheet LQ6RA02 - LQ6RA02 LQ6RA02 Datasheet LQ6RA01 - LQ6RA01 LQ6RA01 Datasheet LQ6RA02 - LQ6RA02 LQ6RA02 Datasheet IAM-C11 - IAM-C11 IAM-C11 Datasheet CAM-C12 - CAM-C12 CAM-C12 Datasheet EP2AGX95 - EP2AGX95 EP2AGX95 Datasheet bq2014HEVM - bq2014HEVM bq2014HEVM Datasheet
Privacy Policy | Disclaimer |