| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Radio Chip 2400 Frequency Agile With Interface High Level Integra
Top Searches for this datasheetHRF-ROC094XC Radio Chip 2400 Frequency Agile With Interface High Level Integration Minimizes System Cost Data Rates over 128.8 Kbits/Sec Direct Connection Microprocessor Integrated Antenna Switch Adjustable detection bandwidths, data rates Adjustable gain, detection level/ hysterisis high beta detection modes Integrated Manchester coding/decoding Programmable Power, Frequency Tx/Rx/Standby Modes Operates From Single 2.5V Power Supply Surface Mount Leadless Plastic Packaging Description Honeywell HRF-ROC094XC half-duplex transceiver wireless communication data applications. Direct microprocessor connection control data transfer, eliminate need additional ICs, while integrated data encode/decode reduces instruction requirements microprocessor. HRF-ROC094XC ideally suited battery powered wireless applications conjunction with microprocessors voice data communication. Adjustable data rates, filter bandwidths detection levels allow used wide variety high sensitivity high environments. Product Photo HRF-ROC094XC Functional Schematic Limiter Demod Control, Code/Decode Switch Site: Email: 2003 09425XC www.mysoiservices.com mysoiservices@honeywell.com Published February 2003 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-ROC094XC Electrical Specifications Advance Information Minimum Typical Parameter Sensitivity Compression Output Power Power Control Data Rate, Channel Rejection Detection Control/Data Test Condition 2.5V 2.5V Frequency 2400-2500 2400-2500 2400-2500 Maximum Units Kbps Continuous PacketizedData Adjacent Channels 350KHz Baseband Filter Passband Serial Peripheral Interface (SPI). Direct Connection Micro controller/Microprocessor Bandwidth reduction possible using chip elements Electrical Specifications 25oC Parameter Power Supply Voltage Power Supply Current During Output Power Dependant (2450 MHz) Power Supply Current (IDD) During (2450MHz) Sleep Mode Current Consumption CMOS Logic Level CMOS Logic Level Input Leakage Current Minimum Typical Maximum Units Absolute Maximum Ratings1 Parameter Absolute Maximum Units Maximum Input Power Voltage (Human Body Model) Operating Temperature Degrees Degrees Storage Temperature (Note Operation HRF-ROC094XC Beyond These Parameters Cause Permanent Damage. Protection: HRF-ROC094XC Contains reduced Protection Circuitry sensitive I/O. Precautions Should Taken During Handling/Assembly Until Protected External Circuitry Housings Site: Email: 2003 09425XC www.mysoiservices.com mysoiservices@honeywell.com Published February 2003 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-ROC094XC Typical Application Analog Power ROC093XC Digital Power Package Outline Leadless Plastic Chip Carrier VIEW HRF-ROC094XC inductance RF/DC ground connection required below part bottom ground used device grounding. Additionally, this connection prodvides direct connection enhanced thermal dissipation. Package shown scale. Site: Email: 2003 09425XC www.mysoiservices.com mysoiservices@honeywell.com Published February 2003 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-ROC094XC Configuration HRF-ROC094XC LPCC(7 Package List RF/Digital ground provided through backside slug pad. Name Sw_Ant Switch Bias Input Digital Gain Control mixer bias mixer bias filter filter filter filter data Detection level Demod Resetn SPI_data_in Dig_data_in SPI_SSN_in SPI_CLK_in Function Antenna connection when on-chip switch used connection when on-chip switch used Bias resistor Receiver input supply voltage gain control supply voltage Mixer supply voltage Resistive bias adjust Resistive bias adjust Baseband filter adjust Baseband filter adjust Baseband filter adjust Baseband filter adjust Analog electronics supply Common mode voltage filtering Analog detected data Detection level adjust Demod common mode voltage power-on reset serial data input Digital receiver test data input slave select clock Name SPI_data_out SPI_INT_out Tx_data_v Rx_out_p Hysterisis Hysterisis P_test_out R_test_out XTAL_Div Crystal Crystal Pdout Rext_PLL Tx_mod data Modulation Modulation High VP-VCO PA_Out_DC PA_Out_AC switch Function serial data output interrupt output Buffered transmitter data Received data, analog output Digital positive supply Digital sample window control Digital sample window control N-counter output R-counter Crystal divided output reference crystal connection reference crystal connection Phase detector charge pump output bias resistor Phase detector supply Data charge pump output Varactor deviation Varactor high deviation Positive supply voltage supply voltage Output, Coupled Positive supply PA_out, coupled thru 10pF connection when on-chip switch used Site: Email: 2003 09425XC www.mysoiservices.com mysoiservices@honeywell.com Published February 2003 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-ROC094XC Customer Demonstration Board Customer Demonstration Board provides ROC094XC radio with microcontroller that interfaces through connection. Using software provided user send files, perform range tests Error Tests. more complete understanding operation radio, user also control operating frequency, power levels internal registers early product development/prototyping. board operates from power single volt supply. Single antenna operation attained through internal switch. Separate Tx/Rx/ ports also available. available, HRF-ROC094XC-K, which includes boards, antennas, cable, documentation control software. Ordering Information Ordering Number HRF-ROC094XC HRF-ROC094XC Note Contact Honeywell details Delivered Tape Reel2 Engineering Evaluation Product Honeywell reserves right make changes improve reliability, function design. Honeywell does assume liability arising application product circuit described herein; neither does convey license under patent rights rights others. Site: Email: 2003 09425XC www.mysoiservices.com mysoiservices@honeywell.com Published February 2003 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 Other recent searchesIS61LV25616AL - IS61LV25616AL IS61LV25616AL Datasheet IR6320G - IR6320G IR6320G Datasheet IDT72V263 - IDT72V263 IDT72V263 Datasheet IDT72V273 - IDT72V273 IDT72V273 Datasheet IDT72V283 - IDT72V283 IDT72V283 Datasheet IDT72V293 - IDT72V293 IDT72V293 Datasheet IDT72V2103 - IDT72V2103 IDT72V2103 Datasheet IDT72V2113 - IDT72V2113 IDT72V2113 Datasheet GL8TR42 - GL8TR42 GL8TR42 Datasheet EURMG2965M - EURMG2965M EURMG2965M Datasheet BZX84C2V4T1 - BZX84C2V4T1 BZX84C2V4T1 Datasheet BF908WR - BF908WR BF908WR Datasheet B32560 - B32560 B32560 Datasheet B32564 - B32564 B32564 Datasheet
Privacy Policy | Disclaimer |