| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
series Enclosed Relay KUIP Coil Contacts KUGP Contact Gap, Coil C
Top Searches for this datasheetCatalog 1308242 Issued 3-03 (PDF Rev. 9-07) series Enclosed Relay KUIP Coil Contacts KUGP Contact Gap, Coil Contacts KUEP 150VDC Load Switching KUMP 277VAC File E22575 File LR15734 RoHS Ready Features coils: 6-240VAC, 50/60 6-110VDC. Contact arrangement 4PDT. Wide selection termination mounting styles. terminals available. Push test button indicator lamps. KUEP incorporates blow magnet high voltage switching. KUIP offers contact-to-coil spacing higher degree isolation. KUGP provides contact contact-to-coil spacing. Complete line sockets rail. Class coil insulation. Users should thoroughly review technical data before selecting product part number. recommended that users also seek pertinent approvals files agencies/laboratories review them ensure product meets requirements given application. Coil Data 25°C Voltage: 110VDC 240VAC. Nominal Coil Power: Coils: Watts KUP, KUIP, KUMP, pole; KUEP, pole. Coils: Watts KUP, pole; KUEP, pole; KUGP. Coils: 2.0VA KUP, KUIP, pole; KUEP, pole. Coils: 2.7VA KUP, KUIP, pole; KUEP, pole; KUGP, KUMP. Coil Data Contact Data 25°C Arrangements: respective ordering information table. Materials: Fine silver amp) silver-cadmium oxide amp). Gold flash available standard. Gold diffused gold alloy special order. Expected Mechanical Life: Contact Ratings Material Fine Silver Arrangement UL/CSA Ratings amps 28VDC 240VAC tungsten @120VAC, 120VDC. @120VAC, 240VAC, FLA, 250VAC (FLA covered 30,000 operations). amps 28VDC 240VAC, tungsten 120VAC, 600VAC, 120VDC. 120VAC, 240, 480, 600VAC, 120VAC, FLA, 250VAC.(FLA ratings covered 30,000 operations) 277VAC, KUMP 28VDC 120VAC, 240VAC, pole exceed total 28VDC, 120VAC, 240VAC, 150VDC 150VDC 150VDC 100,000 Expected Life Volts Nominal Volts Nominal Watt Watt Ohms Nom. Ohms Nom. 32.1 1,800 26.7 1,260 10,000 6,720 Ohms 2,250 9,110 2.7VA Nom. Ohms Nom. 17.5 8.75 1,700 7,200 100,000 SilverCadmium Oxide Pole KUIP KUGP KUEP KUMP Operate Data 25°C 100,000 KUMP Pole KUIP Pole Must Operate Voltage: Coils: nominal voltage less. Coils: nominal voltage less. Operating Time (Excluding Bounce): milliseconds, typical, nominal voltage. Release Time (Excluding Bounce): milliseconds, typical, nominal voltage. 100,000 100,000 Environmental Data 100,000 KUEP SPST-NO KUEP 2PST-NO KUEP 2PDT (All other ratings apply KUEP.) Temperature Range: Operating: Enclosed Relays: -45°C maximum listed table below. Open Relays: 15°C maximum listed. KUIP KUGP KUEP KUMP pole pole +45°C pole +50°C pole +55°C +70°C +75°C +80°C +95°C pole pole pole pole pole pole pole pole pole pole pole Initial Dielectric Strength Between Open Contacts: 1,200V rms; KUGP, 3,500V rms. Between Adjacent Contacts: 2,200V rms. Between Contacts Coil: 2,200V rms; KUGP, KUIP, 3,750V rms. Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) Environmental Data (Continued) Maximum Allowable Ambient Temperature Voltage (KUP enclosed) Max. Ambient Temp. Max. Ambient Temp. Mechanical Data Termination: Quick connect, solder board. Enclosure: Clear polycarbonate dust cover. Weight: (85g) approximately. Nominal Voltage Nominal Voltage Ordering Information Typical Part Basic Series Type: Basic open relay. Basic enclosed relay. Contact Arrangement: (SPST-NO) (SPDT) (DPDT) Coil Input: 50/60 Mountings: Type Codes Available 1,3,4 OPEN STYLE #6-32 stud, .218" (5.54mm) locating tab. #6-32 tapped core, .125" (3.18mm) locating tab. #6-32 tapped core, .218" (5.54mm) locating tab. (through poles) pole models) 1,2,3,4,5, A,E,T 1,3,5,A,E PLAIN CASE; with test button. with indicator lamp.* with test button indicator lamp.* BRACKET MOUNT CASE. PLAIN CASE, #6-32 stud, locating tab. PLAIN CASE, tapped core, locating tab. FLANGE CASE. Indicator lamps available models with following coils: 6-24VAC 110VDC 120-240VAC. Only models with 120-240VAC coils recognized. -120 (3PDT) (4PDT) Terminal Contact Material: Type Pole Models Codes Available Pole Models Pole Models 1**, 5**,7, pole with .187" (4.75mm) quick connect/solder terminals will plug into sockets. Must .110" (2.79 quick connect solder terminals socket mounting. .187" (4.75mm) quick-connect/solder; silver, amps. .187" (4.75mm) quick connect/solder; silver-cadmium oxide, amps. .047" (1.19mm) printed circuit; silver-cadmium oxide, amps. pole KUP: .110" (2.79mm) quick connect/solder; silver-cadmium oxide, amps. .250" (6.35mm) quick connect; silver-cadmium oxide, amps. Gold Flashed Contact Option: Optional gold flashing silver silver-cadmium oxide contacts. Coil Voltage: 240VAC, 50/60 110VDC. Note: part numbers RoHS compliant. authorized distributors more likely stock following items immediate delivery. KUP-5A15-24 KUP-5A15-120 KUP-5A15-240 KUP-5A55-120 KUP-5D15-12 KUP-5D15-24 KUP-5D55-12 KUP-5D55-24 KUP-11A11-120 Dimensions shown KUP-11A15-12 KUP-11A15-24 KUP-11A15-120 KUP-11A15-240 KUP-11A35-120 KUP-11A55-24 KUP-11A55-120 KUP-11AT5-120 KUP-11D11-24 KUP-11D15-5 KUP-11D15-12 KUP-11D15-24 KUP-11D15-110 KUP-11D35-24 KUP-11D55-6 KUP-11D55-12 KUP-11D55-24 KUP-11D55-48 Dimensions inches over (millimeters) unless otherwise specified. KUP-11D55-110 KUP-14A11-120 KUP-14A15-12 KUP-14A15-24 KUP-14A15-120 KUP-14A15-240 KUP-14A25-120 KUP-14A35-120 KUP-14A45-120 KUP-14A55-24 KUP-14A55-120 KUP-14A55-240 KUP-14D11-24 KUP-14D15-6 KUP-14D15-12 KUP-14D15-24 KUP-14D15-48 KUP-14D15-110 KUP-14D25-24 KUP-14D35-24 KUP-14D55-12 KUP-14D55-24 KUP-17A19-120 KUP-17A55-24 KUP-17D19-24 KUP-17D55-24 reference purposes only. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) -120 Ordering Information High Isolation Design Typical Part Basic Series Type: KUIP Enclosed relay with contact coil spacing. KUGP Enclosed relay with open contact spacing contact coil spacing. (Form Form arrangements only) Contact Arrangement: Form (SPDT)* Form (DPST-NO) offered KUGP model. Coil Input: 50/60 Mountings: PLAIN CASE, SOCKET MOUNT. BRACKET MOUNT CASE. Terminal Contact Material: .047" (1.19mm) printed circuit board; silver. FLANGE CASE. Form (DPDT)* Form (3PDT)* KUIP KUGP .187" (4.75mm) quick connect/solder; silver-cadmium oxide. coil data tables. Coil Voltage: 240VAC, 50/60 110VDC. (For 277VAC, consult factory.) Note: part numbers RoHS compliant. authorized distributors more likely stock following items immediate delivery. KUGP-7D55-24 KUIP-5A55-120 KUIP-11D55-12 KUIP-11D55-24 KUIP-14A15-120 KUIP-14D15-12 KUIP-14D15-24 Ordering Information High Voltage Switching Typical Part KUEP -120 Basic Series Type: KUEP Enclosed relay with magnetic blow-outs. Contact Arrangement: (SPST-NO-DM) Coil Input: 50/60 (DPST-NO) (DPDT) Mountings: PLAIN CASE; with indicator lamp.* BRACKET MOUNT CASE FLANGE CASE. Terminal Contact Material: .187" (4.75mm) quick connect/solder; silvercadmium-oxide. *Indicator lamps available models with following coils: 6-24VAC 110VDC 120-240VAC. Only models with 120-240VAC coils recognized. .047' (1.19mm) printed circuit; silver-cadmium-oxide. Coil Voltage: 240VAC, 50/60 110VDC. (For 277VAC, consult factory.) Note: part numbers RoHS compliant. authorized distributors more likely stock following items immediate delivery. KUEP-3A15-120 KUEP-3D15-12 KUEP-3D15-24 Dimensions shown reference purposes only. KUEP-3D15-110 KUEP-7D15-24 KUEP-11A15-120 KUEP-11D15-12 KUEP-11D15-24 Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) -120 Ordering Information Switching Basic Series Type: open relay KUMP enclosed relay Contact Arrangement: (SPST-NO) (SPST-NC) (SPST-NO-DM) (SPST-NC-DB) (SPDT) (SPDT-NC-NO [DB-DM]) (DPST-NO) (DPST-NC) (DPDT) (3PST-NO) (3PST-NC) (3PDT) Coil Input: 50/60 Mountings: Type OPEN STYLE #6-32 stud, .218" (5.54mm) locating tab. 2-hole bracket, #6-32 tapped. #6-32 tapped core, .125" (3.18mm) locating tab. #6-32 tapped core, .218" (5.54mm) locating tab. #6-32 tapped core, locating tab. KUMP PLAIN CASE, #6-32 STUD LOCATING TAB; with test button. with indicator lamp.* with test button indicator lamp.* PLAIN CASE, TAPPED CORE, LOCATING TAB; with test button. with indicator lamp.* with test button indicator lamp.* FLANGE CASE. Typical Part KUMP PLAIN CASE; with test button. with indicator lamp.* with test button indicator lamp.* BRACKET MOUNT CASE; with test button. with indicator lamp.* with test button indicator lamp.* STUD PLAIN CASE. *Indicator lamps available models with following coils: 6-24VAC 110VDC 120-240VAC. Only models with 120-240VAC coils recognized. Terminal Contact Material: Type Pole Models Codes 6,8,9,G Available Pole Models 6,8,9 .205" (5.21mm) quick connect/solder; silver-cadmium-oxide. .187" (4.75mm) quick connect/solder; silver-cadmium-oxide. .047" (1.19mm) printed circuit; silver-cadmium-oxide. .250" (6.35mm) quick connect; silver-cadmium-oxide. (Not available pole models.) Coil Voltage: 240VAC, 50/60 110VDC (For 277VAC, consult factory.) Note: part numbers RoHS compliant. authorized distributors more likely stock following items immediate delivery. KUMP-11A18-24 KUMP-11A18-120 KUMP-11A18-240 KUMP-11D18-12 KUMP-11D18-24 KUMP-11D18-110 KUMP-14A18-24 KUMP-14A18-120 KUMP-14D18-12 KUMP-14D18-24 Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) Outline Dimensions Open Relays Bracket Type (4.8) 1.437 (36.50) 2.43 MAX.* (61.72) 2.33 MAX.** (59.18) 2.29 MAX.*** (58.17) Terminal Dimensions. Terminal Drawings. Seated Heights Open Relays 1.391" (35.33mm) #6-32 stud with .218" (5.54mm) locating tab. 1.52" (38.6mm) bracket with 2-#6 tapped holes. 1.282" (32.56mm) #6-32 tapped core with .125" (3.18mm) .218" (5.54mm) locating tab. 2.046" (51.97mm) relay with printed circuit terminals. (16.0) (16.0) 2.27 MAX.* 2.171 MAX.** (55.14) 2.125 MAX.*** (53.98) #6-32 THREAD TAPPED HOLES (4.1) Stud Type 2.27 MAX.* 2.171 MAX.** (55.14) 2.125 MAX.*** (53.98) .218 (5.54) 1.39 MAX.* (35.3) 1.29 MAX.** (32.8) 1.25 MAX.*** (31.8) .031 (.79) 1.468 MAX. .29) .031 (.79) STUD TYPE also available with .125" (3.18mm) tab, well without stud locating tab. Models without stud have core tapped #6-32 THREAD, .25" (6.4mm) minimum depth. *Dimensions with .250" (6.35mm) terminals. **Dimensions with .110" (2.79mm) .205"(5.21mm) terminals. ***Dimensions with .187" (4.75mm) terminals. 1.391 (35.33) .109 MAX. (2.77) 1.282 MAX. (35.56) 1.687 MAX. (42.85) .065 (1.65) .437 (11.10) #6-32 THREAD .150 WIDTH (3.81) Enclosed Relays Plain Case .288 .32) .187 (4.75) DIA. PUSH-TO-TEST BUTTON AVAILABLE KUMP Core Stud Mount Cases 1.968 MAX. (49.99) 1.906 MAX. (48.41) 1.968 MAX. (49.99) 1.906 MAX. (48.41) .219 MAX. (5.56) 1.531 MAX. (38.89) 1.406 MAX. (35.71) .130 (3.30) 1.43 MAX. (36.27) 1.74 MAX. (44.2) STUD with #6-32 THREAD CORE TAPPED #6-32 .437 .010 (11.10 .25) Terminal Dimensions. Teminal Drawings. 1.39 MAX.* (35.3) 1.29 MAX.** (32.8) 1.25 MAX.*** (31.8) .312 .92) Dimensions with .250" (6.35mm) terminals. Flange Case .078 (1.98) 1.518 MAX. (38.56) Dimensions with .110" (2.79mm), .187" (4.75mm .205" 5.21mm) terminals. *Dimensions with .250" (6.35mm) terminals. 1.713 (43.51 .08) 1.373 .010 1.989 (34.87 .25) (50.52) **Dimensions with .110" (2.79mm) .205" (5.21mm) terminals ***Dimensions with .187" (4.75mm) terminals. Stud Case 1.968 MAX. (49.99) 1.906 MAX. (48.41) 2.248 MAX. .10) .178 (4.52) (9.7) .085 MAX. (2.16) Bracket Mount Case .312 .625 (15.88) .92) 2.90 MAX. (73.7) .078 (1.98) (19.1) PUSH-TO-TESTBUTTON AVAILABLE KUMP 1.531 MAX. (38.89) 1.406 (35.71) 1.128 (28.65) (1.52) #6-32 THREAD (4.1) .375 (9.53) 2.500 (63.50) .437 (11.10) (1.8) 1.968 MAX. (49.99) 1.906 MAX. (48.41) Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) Outline Dimensions (Continued) Relay Front Diagrams Pole Relays 1.531 MAX. (38.89) 1.406 MAX. (35.71) Relays With .250" (6.35mm) Terminals 1.531 MAX. (38.89) Pole Relays 1.531 MAX. (38.89) 1.406 MAX. (35.71) 1.406 MAX. (35.71) Terminal Dimensions .110" (2.79mm) Quick ConnectQuick Connect .205" (5.21mm) Quick Connect .250" (6.35mm) .109 (2.77) HEADER .035 (.89) .311 .90) .034 (.86) .156 (3.96) HEADER .093 (2.36) .205 (5.21 .05) .035 (.89) .070 DIA. .78) HEADER .134 (3.40) .312 .92) .358 (9.09) THICKNESS .032 (0.81) .250 (6.35 .08) .280 .11) .110 (2.79) .032 THICKNESS (.81) .035 .285 (.89) .24) .316 (8.03) .032 THICKNESS (.81) .305 .75) Printed Circuit .156 (3.96) HEADER .237 .156 (6.02) (3.96) .268 (6.81) .032 THICKNESS (.81) .093 (2.36) .180 (4.57) .187" (4.75mm) Quick Connect HEADER .187 .002 (4.75 .05) .125 (3.18) Wiring Diagrams Form Form Form Form *Recommended Load Polarity Optimum Suppression. Board Layouts (Bottom Views) Form .076 DIA. (1.93) Pole Models .076 DIA. .93) .206 (5.23) .626 (15.90) .875 (22.23) .437 (11.10) .875 (22.23) .340 (8.64) .510 (12.95) 1.020 (25.91) Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. .047 (1.19) .250 .078 (6.35) (1.98) .281 REF. (7.14) .020 THICKNESS (.51) Note: drawings shown oversize. Form Form Pole Models .076 DIA. (1.93) .206 (5.23) .328 (8.33) .626 (15.90) .328 (8.33) .626 (15.90) .170 (4.32) Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) Sockets Series Relays Through Poles Socket Selection Table Stock items boldfaced. KUP, KUEP, KUGP, KUIP, KUMP relays, through poles, with .187" (4.75mm) quick connect termination. Socket 27E043 27E046 27E067 27E121 27E305 27E396 27E893 Socket Termination Solder eyelet board, .144" (3.66mm) terminals .187" (4.75mm) quick connect Screw terminals board, .184" (4.67mm) terminals .187" (4.75mm) quick connect* Screw terminals Hold-Down Spring 20C228 20C254* 20C228 20C254 20C228 20C254 20C314 socket required) 20C228 20C254 20C254 20C318 20C228 held place socket hold-down screw where 20C254 snaps onto socket. Snap-in mounting. rail mounting. Note: part numbers RoHS compliant. Hard Mount Sockets Relays Through Poles Nylon sockets with .187" (4.75mm) quick connect, solder printed circuit terminals available KUEP, KUGP, KUIP, KUMP, relays, through poles, with .187" 1.370 (4.75mm) quick connect terminals. rated amps recognized, File (34.80) E59244 certified File LR15734 27E043-with solder eyelet terminals. 27E067-with .187" (4.75mm) quick connect terminals. 1.50 (38.1) .165 DIA. (4.19) HOLES (12.7) 27E043 27E067 1.687 .010 (42.85 .25) 2.03 (51.56) 1.250 (31.75) 1.250 (31.75) .875 .010 (22.23 .25) .297 .54) MAX. (8.64) .125 (3.18) .250 (6.35) .297 .54) MAX. (8.64) .125 (3.18) .250 (6.35) 1.375 (34.93) 27E043 27E067 chassis cutout shown this page. 27E046, 27E305 Socket With Printed Circuit Terminals HOLES .165 DIA. (4.19) 1.370 (34.80) (12.7) Suggested Socket Board Layout .875 (22.23) .437 (11.10) .218 (5.54) 1.687 (42.85) 1.076 .33) .328 (8.33) 27E396 Snap-In Socket Relays Through Poles Nylon snap-in socket with .187" (4.75mm) quick connect terminals available KUEP, KUGP, KUIP, KUMP, relays, through poles, with .187" (4.75mm) quick connect terminals. Snap-in sockets reduce labor eliminating time consuming screw rivet mounting. Preassembled wiring harnesses also used sockets designed snap into chassis from either front back. rated amps recognized, File E59244. 27E396 uses chassis cutout shown this page. 27E396-with .187" (4.75mm) quick connect terminals. .076 DIA. (1.93) 1.687 .010 (42.85 .25) 2.03 (51.56) .626 (15.90) .090 (2.29) .297 (7.54) 1.50 (38.1) .875 .010 .125 (22.23 .25) (3.18) .023 (.58) .180 (4.57) .156 (3.96) 27E046 TERMINALS .144" (3.66 LONG. 27E305 TERMINALS .184" (4.67 LONG. Recommended Chassis Cutout Hard Mount Sockets .875 (22.23) 1.395 (35.43) Recommeded Chassis Cutout Snap-In Sockets .396 (10.06) 1.260 (32.0 .110 (2.79) PLACES 1.687 (42.85) 1.270 (32.26) 1.270 (32.26) 1.375 (34.93) .239 (6.07) .020 (.51) 1.395 (35.43) Recommended chassis thickness .031" (.79mm) .062" (1.57mm). .065 (1.65) .281 .14) .260 (6.60) .156 DIA. (3.96) .208 HOLES (5.28) Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 9-07) Sockets Series Relays Through Poles (continued) 27E121 Screw Terminal Socket 27E893 Screw Terminal, Rail Snap-Mount Socket (use with mounting track 24A110) 27E121 socket offers screw termination KUEP, KUGP, KUIP, KUL, KUMP relays, through poles, with .187" (4.75mm) quick connect terminals. This socket stacks 1.700" (43.18mm) centers. When surface mounting, #6-32 screws suitable length required. When track mounting, 24A071 retainer clips (not shown) required. 27E121 rated amps recognized, File E59244, certified, File LR15734. 27E893 rail, snap-mount socket offers screw termination KUEP, KUGP, KUIP, KUL, KUMP relays, through poles, with .187" (4.75mm) quick connect terminals. This socket constructed with spring-loaded latch which allows quickly snapped onto removed from "top hat" style mounting track. special tools extra hardware required installation. 27E893 rated amps, 94V-0, File E59244 rated amps, File LR15734. Terminal Location 1.700 .010 (43.18 .25) .850 .010 (21.59 .25) .895 MAX. (22.73) .540 (13.72) .315 MIN. (8.00) 1.550 (39.37) View Terminal Location View .156 (3.96) 1.500 (38.10) 3.000 (76.20) .156 (3.96) 1.500 (38.10) 3.150 MAX. (80.01) 1.703 (43.26) .317 (8.04) 1.030 (26.16) 1.450 MAX. (36.83) 1.900 MAX. (48.26) .390 (9.91) #6-32 SCREWS CAPTIVE WASHERS Sockets Series Pole Relays Socket Selection Table Stock items boldfaced. pole relays with .110" (2.79mm) quick connect termination. Socket 27E415 27E419 27E867* Socket Termianation .187" (4.75mm) quick connect board Screw terminals Hold-Down Spring 20C228 20C254 20C228 20C254 20C254 40G432 insulator customer supplied alternative. Note: part numbers RoHS compliant. Hard Mount Sockets Pole Relays 27E415-with .187" (4.75mm) quick connect/solder terminals. 27E419-with printed circuit terminals. board layout right. Note: Only pole relays with .110" (2.79mm) quick connect terminals used with pole hard mount sockets. Suggested Socket Board Layout .076 DIA. (1.93) .206 (5.23) Screw Terminal Socket Pole Relays 27E867 offers screw termination pole relays with .110" (2.79mm) quick connect/socket mount terminals. Rated amps recognized, File E59244. .156 DIA. (3.96) MTNG. HOLES 1.750 .010 (44.45 .254) 3.50 .030 (88.9 .762) .230 .030 (5.84 .762) .250 .010 #6-32 SCREWS (6.35 .254) .150 MAX. (3.81) 2.250 .010 .254) 2.750 .015 (69.96 .381) .165 (4.19 .13) HOLES (12.7) .060 (1.52) 1.687 (42.85) .340 (8.64) .328 (8.33) .626 (15.90) .170 (4.32) .510 (12.95) 1.020 (25.91) 1.370 (34.80) 2.03 (51.6) 1.250 (31.75) .062 .57) .770 MAX. (19.56) .875 (22.23) 1.50 (38.1) .125 (3.18) .297 .54) MAX. (8.1) W/QC TERMINALS .250 (6.35) 27E415 uses same chassis cutout 27E043. .461 MAX. (11.71) W/PC TERMINALS Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Other recent searchesQS-240A - QS-240A QS-240A Datasheet LB11699H - LB11699H LB11699H Datasheet LB11699HCD-ROM - LB11699HCD-ROM LB11699HCD-ROM Datasheet HMC408LP3 - HMC408LP3 HMC408LP3 Datasheet HJS18Z - HJS18Z HJS18Z Datasheet E89356 - E89356 E89356 Datasheet CO-401 - CO-401 CO-401 Datasheet C8051F352 - C8051F352 C8051F352 Datasheet 1C4956T - 1C4956T 1C4956T Datasheet
Privacy Policy | Disclaimer |