Fieldbus Installationbus 4-channel receiver Galvanically sep


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Receiver Digital Signals Types 3430 1149, 3430 2249, 3430 4443
Fieldbus
Installationbus
4-channel receiver Galvanically separated SPDT SPST relay outputs Load: A/250 A/250 A/250 H4-housing mounting DIN-rail 50022) LED-indications supply, outputs Dupline® carrier power supply Channel coding 1605 (see data sheet 1605 details)
Product Description
Dupline receiver. SPDT relay outputs control loads
Ordering
Type: Dupline H4-housing Receiver channels Output type Power supply
3430 4443
VAC/10 SPST relay outputs control loads VAC/5
Type Selection
Supply Ordering channel A/250 3430 1149 3430 1149 3430 1149 3430 1149 3430 2249 3430 4443 Ordering channels A/250 3430 2249 3430 2249 3430 2249 Ordering channels A/250 3430 4443 3430 4443 3430 4443
Output Specifications
3430 1149 channel) SPDT relay (micro gap) A/250 (2500 A/250 (250 A/25 (250 A/230 A/24 operations operations 7200 operations/h kVAC (rms) pulse train 3430 2249 channels) SPDT relays (micro gap) A/250 (2500 A/250 (250 A/25 (250 A/230 A/24 operations operations 7200 operations/h kVAC (rms) pulse train 3430 4443 channels) SPST relays (micro gap) A/250 (1250 0.25 A/250 A/25 (125 A/230 A/24 operations operations 7200 operations/h kVAC (rms) pulse train
Outputs Isolated groups Contact ratings (AgCdO) Resistive loads Inductive loads Mechanical lifetime Electrical lifetime load) Operating frequency Dielectric voltage Outputs Dupline® Response time
Specifications subject change without notice (28.09.99) Dupline® registered trademark. product CARLO GAVAZZI Group
3430 1149, 3430 2249, 3430 4443
Fieldbus
Installationbus
Supply Specifications
Power supply Overvoltage cat. (IEC 60664) Rated operational voltage through term. (IEC 60038) (IEC 60038) Frequency Voltage interruption Rated operational power 3430 1149 024/115/230 Typ. 3430 2249 024/115/230 Typ. 3430 4443 024/115/230 Typ. Power dissipation 3430 1149 024/115/230 3430 2249 024/115/230 3430 4443 024/115/230 Rated impulse withstand voltage Dielectric voltage Supply Dupline® kVAC (rms) Supply Outputs kVAC (rms) Power supply types Operational voltage through term. Ripple Reverse-polarity protection Rated operational current 3430 1149 3430 2249 3430 4443 Power dissipation 3430 1149 3430 2249 3430 4443 Inrush current Rated impulse withstand voltage Dielectric voltage Supply Dupline Supply Outputs Overvoltage cat. (IEC 60664) (ripple included) (ripple included) (rms) kVAC (rms)
General Specifications
Output delay Upon loss Dupline carrier Power delay Power delay Indication Supply Output Dupline® carrier Environment Degree protection Pollution degree Operating temperature Storage temperature Humidity (non-condensing) Mechanical resistance Shock Vibration Dimensions Material (see Technical informations) Weight 3430 1149, 3430 2249 3430 4443 Typ. LED, green LED, (one output) LED, yellow (IEC 60664) -20° +50°C (-4° +122°F) -50° +85°C (-58° +185°F)
Mode Operation
1-channel receiver with change-over contact output output coded means code programmer 1605. output normally OFF. When transmitter coded selected channel activated, output turns remains until respective channel becomes deactivated. default setting such that upon loss Dupline® carrier output goes off. 2-channel receiver with change-over contact outputs Each output coded individually means code programmer 1605. outputs normally off. When transmitter coded selected channel activated, output turns remains until respective channel becomes deactivated. default setting module such that upon loss Dupline® carrier outputs off. 4-channel receiver with four normally open contact outputs Each output coded individually means code programmer 1605. default setting module such that upon loss Dupline® carrier outputs off. changing default setting, please refer datasheet 1605.
H4-housing
Operation Diagram
Power supply Dupline® carrier Transmission channel Output Transmission channel Output
Specifications subject change without notice (30.04.03) Dupline® registered trademark. product CARLO GAVAZZI Group
3430 1149, 3430 2249, 3430 4443
Fieldbus
Installationbus
Wiring Diagrams
channel 3430 1149 (DC) supply channels 3430 2249 (DC) supply
Signal wire
Output Power supply
Signal wire
OutPower supply
Output
channels 3430 4443 (DC) supply
Accessories
DIN-rail further information, "Accessories".
Power supply
Signal wire
Specifications subject change without notice (28.09.99) Dupline® registered trademark. product CARLO GAVAZZI Group

Other recent searches


ZXGD3102T8 - ZXGD3102T8   ZXGD3102T8 Datasheet
ZLF645 - ZLF645   ZLF645 Datasheet
SC16C550 - SC16C550   SC16C550 Datasheet
RB495D - RB495D   RB495D Datasheet
NJW1144 - NJW1144   NJW1144 Datasheet
NJW1144TVBBE - NJW1144TVBBE   NJW1144TVBBE Datasheet
NJW1144BBE - NJW1144BBE   NJW1144BBE Datasheet
NJW1144GK1 - NJW1144GK1   NJW1144GK1 Datasheet
LB140DS30 - LB140DS30   LB140DS30 Datasheet
IA186XX-D - IA186XX-D   IA186XX-D Datasheet
IA186ES-PQF100I-03 - IA186ES-PQF100I-03   IA186ES-PQF100I-03 Datasheet
AN1321 - AN1321   AN1321 Datasheet
ST72141 - ST72141   ST72141 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive