| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Model self contained, current output, powered signal conditioner bridg
Top Searches for this datasheetModel Bridgesensor Model self contained, current output, powered signal conditioner bridge type instrumentation. contains precision differential amplifier with filtered output highly regulated, noise, adjustable output bridge excitation source. Model contains isolated DC/DC converter which operates Volts unit completely encapsulated rugged environments. Complete Strain Gage Bridge Signal Conditioner 4-20 ±8mA Output Contains Isolated DC/DC Converter with 0.5mV/V 10mV/V Sensors Drives Four Bridges Volts Rugged Epoxy Encapsulated Design Applications Weighing with Load Cells Process Control Add-on Loops Intrinsically Safe Applications Used With Types Output Sensors Block Diagram Manufacturing Company, Inc. Concord, California 94520 925/687-4411 800/542-3355 Fax: 925/687-3333 www.calex.com Email: sales@calex.com D-303 Model Bridgesensor Specifications NOTE: Specifications apply 55°C Volts input. Output Current Span Input Span Zero Adjust Minimum Output Temperature Coefficient Hysteresis Amplifier Cell Sensitivity Volts Excitation) Linearity Temperature Stability Hysteresis Input Bias Current Input Noise: Common Mode Input Common Mode Rejection Output Current Loop Resistance Compliance Frequency Response Response Time 0.1% Bridge Excitation Supply Adjustment Range Load Current Stability Hysteresis Requirements mA;12 ±8mA ±75% span microamp microamp/°C typical microamp/°C maximium microamp maximum mV/V mV/V 0.005% typical ppm/°C 0.1% span maximum maximum microvolts maximum +7.5 Volts minimum Getting Started with Model This procedure large tare weights, i.e. greater than about cell's full scale rating. Hook Procedure Connect your load cell INPUT, Connect your load cell INPUT, Note: SENSE used your application, connections step need followed. SENSE going used, jumper them described steps Connect +Excitation, excitation your load cell jumper SENSE, +Excitation, Connect -Excitation, excitation your load cell jumper SENSE, -Excitation, Determine voltage power supply used adjust within volt range necessary before connecting power pins, Verify that hook procedure complete. Turn power supply check bridge excitation supply. Calibration Procedure required load cell excitation voltage using ADJUST. GAIN SWITCH expected load cell output. Short signal input pins together with clip lead. Adjust COARSE FINE OFFSET pots, output current. Remove short from step With load cell, readjust zero output. Apply live load cell adjust GAIN, desired output current. COARSE FINE OFFSET pots output current. Repeat steps until desired settings obtained. 1000 Volts maximum Hertz, Pole Filter typical Volts maximum ppm/°C maximum 0.1% Input power supply isolated from amplifier reverse polarity protected. Input Voltage Volts Input Current with 150mA load 0.17A 0.7A with Bridge 0.1A 0.35A Hertz Ripple allowed Volt Volts input input supply Volts above Volts input Isolation Volts .0033 Manufacturing Company, Inc. Concord, California 94520 925/687-4411 800/542-3355 Fax: 925/687-3333 www.calex.com Email: sales@calex.com D-303 Model Bridgesensor Amplifier built-in amplifier true differential input, noise, drift, instrumentation amplifier. high common mode rejection ratio (CMRR) provided with output offset that potentiometer adjustable. output offset pots adjust output zero current instrumentation amplifier gain switch which changes gain factors gain potentiometer fine adjustments. amplifier accepts input signals amplifier withstand input voltages Volts without damage. output amplifier filtered down using double pole Butterworth filter minimize effects high frequency electrical physical noise system. MODEL POWER INPUT 1000 supply remote sensing provisions wire configurations. sense lines minimize variations output voltage with changes load current lead resistance. should noted that sense feature being used, terminal must connected terminal Terminals must connected also. supply output, connected through safety barrier sense lines will regulate voltage across bridge between Volts. supply short circuit protection protect against short term faults. output recovers automatically from short circuit conditions once short removed. Application Figure show typical application using remote sense lines 4-20 output. When using shielded cable between model transducer, connect shield only. connected inside module. switch expected full scale output transducer figure With connected bridge, short input, pins adjust coarse fine offset pots 4.00 output. Then gain full scale calibration. Recheck zero current. zero current changed, reset full scale. SUPPLY CURRENT B+LOAD =150mA B+LOAD =30mA POWER SUPPLY VOLTAGE Bridge Excitation Supply Transducer excitation provided adjustable, well regulated, noise power supply. excitation voltage adjustable means molded-in potentiometer which allows output voltage varied from Volts. capable supplying 150mA drive five load cells Volts. fault mode maximum output current will range from approximately with 1000 ohms loop resistance into zero loop resistance. Only Switch Expected Transducer Full Scale Output FIGURE Gain Range Switch FIGURE Typical Application D-303 Manufacturing Company, Inc. Concord, California 94520 925/687-4411 800/542-3355 Fax: 925/687-3333 www.calex.com Email: sales@calex.com Model Bridgesensor Mechanical Specifications Specifically designed rugged field Model completely encapsulated epoxy using vacuum potting system insure complete seal against corrosive environments. similarly protected against shock vibration will provide years reliable accurate operation. FIGURE Case Dimensions Terminal Strip Assignments Screw Terminal Function Screw Terminal Function POWER POWER -SENSE B+SENSE CURRENT OUTPUT AMPLIFIER -INPUT +INPUT Manufacturing Company, Inc. Concord, California 94520 925/687-4411 800/542-3355 Fax: 925/687-3333 www.calex.com Email: sales@calex.com D-303 Other recent searchesSN74LVC3G17 - SN74LVC3G17 SN74LVC3G17 Datasheet SN74ALS804A - SN74ALS804A SN74ALS804A Datasheet SN74AS804B - SN74AS804B SN74AS804B Datasheet SN54ALS804A - SN54ALS804A SN54ALS804A Datasheet SN54AS804B - SN54AS804B SN54AS804B Datasheet MU9C5480A - MU9C5480A MU9C5480A Datasheet MR750 - MR750 MR750 Datasheet MR7510 - MR7510 MR7510 Datasheet MCH6602 - MCH6602 MCH6602 Datasheet IDT49FCT5805 - IDT49FCT5805 IDT49FCT5805 Datasheet HCPL-316J - HCPL-316J HCPL-316J Datasheet C2680-H - C2680-H C2680-H Datasheet bq2031 - bq2031 bq2031 Datasheet
Privacy Policy | Disclaimer |