The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

WATT DC-DC POWER SUPPLY ALLEN BRADLEY 1771 SYSTEM FEATURES Active


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



PLC4000 SERIES
WATT DC-DC POWER SUPPLY ALLEN BRADLEY 1771 SYSTEM
FEATURES Active Current Sharing Full Redundant Operation Swap Capability Remote Sense Monitor Alarm Status Hold Time 20mS Multiple Input Voltage Ranges Input Output Protection
Input
Input Power: watts max. Status Alarm: Signals input voltage drops below specified range. Transient Protection: Fuse back back zener diodes protect against catastrophic failure. Reverse Polarity Protection: Unit will turn verse polarity detected. Isolation: 725V minute, 850V second. Conditions: input output input case.
General Description
lntronics' PLC4xxx external DC-DC power supply designed completely safely power fully loaded Allen Bradley 1771 PLC. PLC4xxx operated "stand alone" "redundant mode" high availability system configurations. units mount externally 1771 maximize available slots provide amps 5Vdc power most standard 1771 rack configurations. units contain appropriate monitoring alarm circuitry interface with 1771 rack. event input power failure, units have sufficient hold time ensure orderly system shutdown.
Output
Output Voltage: 4.87 5.25 (normal range 1771 system, including noise ripple.) Current Range (non-redundant): min., max. Current Range (redundant): min., max. Remote Sense: Maintains accurate voltage with
General Specifications
Size: 3.8" Refer figure Power supply System Interface: Refer fig. stand alone configuration. Refer fig. redundant mode configuration. Fuse: user accessible. Input Cable: wire. Output Cable: wire, foot max. Indicator: Input output voltages within specified limits when illuminated. Safety Agency Approval: Pending (UUCSA/CE).
recommended cable wire).
Overcurrent: Unit will shutdown 110-130% rated output current. Reset cycling power seconds. Overvoltage: Unit shuts down output voltage exceeds redundant configuration, range Undervoltage: Provides status alarm. Turn Time: sec. max. specified output range. Ripple: max. p-p, ripple noise: max. measured power input (through cable). Load Sharing: Active load sharing enabled redundant configuration. Hold Time: min. after ride-through under worst case line load conditions. Transient Load: Maintains specified operation load change. Shutdown result transients greater than 25%. Status Output: Closed relay contact when outputs within specified range. Output: Power good signal 1771 rack.
Ordering Information
Model Number PLC4024 PLC4048 PLC4125 Input Voltage nominal) nominal) (125 nominal)
Rockwell Automation EncompassPartner
Intronics, Inc. 1400 Providence Highway, Building Norwood, 02062 Phone: 781-551-5500 Fax: 781-551-5555 Toll Free: 800-367-0004 www.intronicspower.com
Mechanical Specifications Connection Diagrams
Mechanical Configuration Figure
.250 .203 plcs) Screw
Ordering Information
Model Number PLC4024 PLC4048 PLC4125 Input Voltage nominal) nominal) (125 nominal)
7.500
Intronics DC-DC Converters
FUSE
8.000
PLC4XXX
Cables
Stand alone configuration
IPN: 808-19960-10 (figure
Input Power Status Line
8.230 9.00
Cable S1/J5 Cable R1/TB1
Length Length
.335
4.115
Single Redundant configuration
IPN: 808-19960-20 (figure
3.80
SIDE VIEW
INPUT POWER STATUS LINE Power Output Current Share Redundant
Single Unit Configuration Figure
Terminal Block
Note: Cable kits must ordered separately. connectors included cable kits.
PLC4xxx Power Supply S1/J5
1771
Connections Description
J1-1 J1-2 J1-3 J2-1 J2-2 J3-1 J3-2 J3-3 J3-4 Description Chassis Status Status Share Share Blank Blank Share Return Shield Chassis Connect J5-A1 J5-1 J5-2 J5-3 J5-4 J5-A2 Case Description +5Vdc +Sense -Sense +5Vdc Return Chassis
Redundant Unit Configuration Figure
PLC4xxx Power Supply
R1/TB1 1771
J3-5 J3-6 J3-7 J3-8 J3-9 Case
PLC4xxx Power Supply
Note: hazardous environments, input power must turned when fuses being changed units being swapped.
Environmental Specifications
Storage Temperature: -40°C 85°C Operating Temperature: 60°C, baseplate 75°C Humidity: non-condensing
Note: Specifications subject change without notice.
Intronics, Inc. 1400 Providence Highway, Building Norwood, 02062 Phone: 781-551-5500 Fax: 781-551-5555 Toll Free: 800-367-0004 www.intronicspower.com

Other recent searches


S-90N0232SUA - S-90N0232SUA   S-90N0232SUA Datasheet
RB215T-90 - RB215T-90   RB215T-90 Datasheet
eZ430 - eZ430   eZ430 Datasheet
EL5525 - EL5525   EL5525 Datasheet
FN7393 - FN7393   FN7393 Datasheet
DS51308A - DS51308A   DS51308A Datasheet
DB848H65 - DB848H65   DB848H65 Datasheet
DB848H65-XY - DB848H65-XY   DB848H65-XY Datasheet
DB848H65E-XY - DB848H65E-XY   DB848H65E-XY Datasheet
CCSO-914X-1000 - CCSO-914X-1000   CCSO-914X-1000 Datasheet
2SC3688 - 2SC3688   2SC3688 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive