| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
INCH IMAGE SENSOR CERDIP KC73125-M interline transfer area i
Top Searches for this datasheetKC73125-M INCH IMAGE SENSOR CERDIP KC73125-M interline transfer area image sensor developed 1/3inch video cameras. used door phone, surveillance camera, object detection pattern recognition. FEATURES High Sensitivity Optical Size 1/3inch Format Variable Speed Electronic Shutter Dark Current High antiblooming Smear Horizontal Register Drive 16pin Ceramic Package Field Integration Read System ORDERING INFORMATION Device KC73125-M Package 16pin CERDIP Operating Temperature -10°C 50°C STRUCTURE Number total pixels Number effective pixels Chip size Unit pixel size Optical blacks dummies 5.90mm(H) 5.10mm(V) 9.60µm(H) 7.50µm(V) Refer from below figure Dummy Pixels Effective Imaging Area OUTPUT V-CCD Optical Black Pixels Effective Pixels H-CCD KC73125-M BLOCK DIAGRAM INCH IMAGE SENSOR VERTICAL SHIFT REGISTER VERTICAL SHIFT REGISTER VERTICAL SHIFT REGISTER VERTICAL SHIFT REGISTER HORIZONTAL SHIFT REGISTER VOUT DESCRIPTION Symbol Description Vertical Transfer Clock Vertical Transfer Clock Vertical Transfer Clock Substrate Voltage Vertical Transfer Clock Protective Bias Voltage Ground Output drain Voltage Symbol VOUT Description Signal Output Output Gate Voltage Output Source Voltage Ground Reset Drain Voltage Charge Reset Clock Horizontal Transfer Clock Horizontal Transfer Clock KC73125-M ABSOLUTE MAXIMUM RATINGS Characteristics Substrate Voltage Supply Voltage Vertical Clock Input Voltage Horizontal Clock Input Voltage Voltage Difference between Vertical Horizontal Clock Input Pins Output Clock Protection Circuit Bias Voltage Operating Temperature Storage Temperature *(1) INCH IMAGE SENSOR Symbols SUB-GND VDD,VOUT,VSS-GND V1,V2,V3,V4-GND V1,V2,V3,V4-VL H1,H2 V1,V2,V3,V4 H1,H2 H1,H2 RG,VGG Min. -0.3 -0.3 -0.3 -0.3 -0.3 Max. Unit device destroyed, applied voltage temperature higher than absolute maximum rating voltage temperature. CONDITIONS Item Output Stage Drain Bias Output Stage Gate Voltage Output Stage Source Voltage Substrate Voltage Adjustment Range Fluctuation Voltage Range after Substrate Voltage Adjusted Reset Gate Voltage Adjustment Range Fluctuation Voltage Range after Reset Gate Voltage Adjusted Protection Circuit Bias Voltage Output Stage Drain Current Symbol VSUB VSUB VRGL VRGL Min. Typ. Max. Unit Remark 14.55 15.0 15.45 1.75 2.25 Ground through 19.0 voltage vertical clock waveform CLOCK VOLTAGE CONDITIONS Item Read-out Clock Voltage Vertical Transfer Clock Voltage Horizontal Transfer Clock Voltage Charge Reset Clock Voltage Substrate Clock Voltage Symbol VVH1~VVH4 VVL1~VVL4 VRGLH-VRGLL VSUB Min. 14.55 -0.05 -9.0 4.75 -0.05 4.75 20.0 Typ. 15.0 -8.5 23.5 Max. 15.45 0.05 -8.0 5.25 0.05 5.25 25.0 Unit Remark High level VVH=(VVH1+VVH2)/2 VVL=(VVL3+VVL4)/2 High High Shutter KC73125-M INCH IMAGE SENSOR DRIVE CLOCK WAVEFORM CONDITIONS Read clock waveform 100% Vertical transfer clock waveform VVH1 VVHH VVHH VVHH VVHL VVH3 VVHL VVHH VVHL VVL1 VVLH VVLL VVL3 VVLL VVLH VVHH VVHH VVHL VVHH VVHH VVH2 VVHL VVHL VVH4 VVHL VVL2 VVLL VVLH VVLL VVLH VVL4 KC73125-M Horizontal transfer clock waveform diagram INCH IMAGE SENSOR Reset gate clock waveform diagram VRGH Point waveform VRGL 0.5V VRGL VRGLH VRGLL waveform VRGLH maximum value RGLL minimum value coupling waveform period from Point diagram about rise VRGL=(VRGLH+VRGLL)/2 VRG=VRGH-VRGL Substrate clock waveform 100% VSUB VSUB KC73125-M INCH IMAGE SENSOR CLOCK EQUIVALENT CIRCUIT CONSTANT Item Capacitance between Vertical Transfer Clock Symbol CV1, CV2, CV12, CV34 CV23, CV41 CV13 CV24 CH1, CH12 CSUB RGND RH1, Typ. 1,300 1,300 1120 Unit Remark Capacitance between Vertical Transfer Clocks Capacitance between Horizontal Transfer Clock Capacitance between Horizontal Transfer Clocks Capacitance between Reset Gate Clock Capacitance between Substrate Clock Vertical Transfer Clock Serial Resistor Vertical Transfer Clock Ground Resistor Horizontal Transfer Clock Serial Resistor Reset Gate Clock Serial Resistor CV12 CV13 RGND CV23 CV34 KC73125-M IMAGE SENSOR CHARACTERISTICS INCH IMAGE SENSOR 25°C) Item Sensitivity Saturation Signal Smear Blooming Margin Uniformity Dark Signal Flicker Symbol YSAT Min. Typ. 0.015 1,000 Max. Unit mV/lux times Test method Remark Ta=50°C SPECTRAL RESPONSE CHARACTERISTICS (Excluding light source characteristics) SPECTRAL DISTRIBUTION RELATIVE RESPONSE RELATIVE RESPONSE WAVE LENGTH(nm) KC73125-M TEST CONDITION INCH IMAGE SENSOR light source with color temperature 3,200K light source adjusted accordance with average value signals indicated each item. Through following tests substrate voltage reset gate clock value bias condition while device condition typical value bias clock conditions. Through following tests, defects excluded unless otherwise specified optical black level (hence forth referred reference output signal which taken signal output. TEST METHODS Measure light intensities when averaged illuminance output value standard illuminance output value, 150mV (YA) when half 150mV (1/2 YA). L1YA Adjust light intensity times that signal output average value 150mV) then test signal minimum value (Y=YSAT). Adjust light intensity times that signal output average value (YA=150mV), then remove read-out clock drain signal photosensors electronic shutter operation respective horizontal blanking times with other clocks unchanged. Measure maximum illuminance output value (YSM). 100(%) Adjust light indensity 1000 times that signal output average vlaue 150mV), then confirm that Blooming dose appear. Measure maximum minimum illuminance output value (YMAX, YMIN) when light Intensity adjusted make YMAX YMIN 100(%) Measure signal output average value [mV] with horizontal idling time transfer level reference, when device ambient temperature 50°C light sources shielded. Adjust light intensity make Y=YA. Measure difference value (YF) between averaged illuminance signal values even fields. KC73125-M APPLICATION CIRCUITS INCH IMAGE SENSOR 22µH XSUB XSG1 XSG3 10µF /10V KS7221D KC73125-M 0.47µF /20V 0.47µF /20V VOUT 10µF /10V 22µH 22µH OUTPUT 4.7K KSC1623 MA110 100K /20V 47µF /10V 3.3K 180K KSC2757 /20V 3.9K 10µF /20V KC73125-M READ-OUT CLOCK TIMING CHART INCH IMAGE SENSOR Unit: FIELD 38.1 EVEN FIELD KC73125-M INCH IMAGE SENSOR CLOCK TIMING CHART (VERTICAL SYNC.) CLOCK TIMING CHART (HORIZONTAL SYNC.) XSHP XSHD CLP1 (During electronic shutter operation) KC73125-M PACKAGE DIMENSIONS INCH IMAGE SENSOR (Unit=mm) Center effective imaging area/ Center package 7.00 t=0.25+0.02 8.00+0.10 10.20+0.10 12.40+0.12 6.20 8.00+0.10 10.20+0.10 14.00+0.12 Rotation error =1.5 1.10+0.08 3.00+0.25 1.27+0.25 3.00 0.46+0.10 1.78+0.5 12.46+0.10 13.60+0.12 0.91+0.10 Optical center deviation from mechanical center ±0.15mm direction. Optical surface height from glass surface ±0.15mm Optical surface height from package backside bottom 0.10mm KC73125-M HANDLING INSTRUCTIONS INCH IMAGE SENSOR Static charge prevention image sensors easily damaged static discharge. Before handling sure take following protective measures. chargeable gloves, clothes material. Also conductive shoes. When handling directly, earth band. Install conductive floor working table prevent generation static electricity. Ionized recommended discharging when handling image sensor. shipment mounted substrates, boxes treated prevention static charges. Soldering Make sure package temperature does exceed 80°C Solder dipping mounting furnace causes damage glass other defects. grounded soldering iron solder each less than seconds. repairs remount, cool sufficiently. dismount imaging device, solder suction equipment. When using electronic disoldering tool, thermal controler zero cross On/Off type connect ground Dust Dirt protection Operate clean environments (around class 1000 will appropriate). either touch glass plates hand have object come contact with glass surface. Should dirt stick glass surface blow with blow (for dirt stuck through static electricity ionized recommended). Clean with cotton ethyl alcohol glass surface grease stained. carful scratch glass. Keep case protect from dust dirt. prevent condensation, preheat precool when moving room whith great temperature differences. When protective tape applied before shipping, just before remove tape applied electrostatic protection. reuse tape. expose strong light (sun rays) long period, color filter discolored Exposure high temperatures humidity will affect characteristics. Accordingly avoid storage usage such conditions. image sensors precise optical equipment that should subject mechanical shocks. Other recent searchesST-48 - ST-48 ST-48 Datasheet SLP1610P4T - SLP1610P4T SLP1610P4T Datasheet SLP2510P8T - SLP2510P8T SLP2510P8T Datasheet Components - Components Components Datasheet B4146 - B4146 B4146 Datasheet QSW025A0B - QSW025A0B QSW025A0B Datasheet ICS950219 - ICS950219 ICS950219 Datasheet EIA-296-E - EIA-296-E EIA-296-E Datasheet DG508A - DG508A DG508A Datasheet FN3137 - FN3137 FN3137 Datasheet AD8515 - AD8515 AD8515 Datasheet
Privacy Policy | Disclaimer |