CEZAR Manual
Foreword
CEZAR PC-based system combines functionality traditional operator terminal with advanced programming features SCADA system. gives developer opportunities fast programming adaptability various applications. CEZAR comes with wealth ready-to-use, basic functions. CEZAR system supplied either hardware software, software only. hardware arrives with CEZAR pre-installed IPC-15 industrial running Windows Professional. This manual mainly explains configuration tool used. However, some tips such make communication efficient possible provided. function-based descriptions, please CEZAR User's Guide (MA00599A).
Beijer Electronics MA00600A, 2003-11
examples manual intended solely increase understanding software's functionality use. Beijer Electronics bears responsibility these examples used actual applications. Because large number application areas this software, users must acquire appropriate knowledge software properly their specific applications. Persons responsible application must themselves ensure that each application compliance with relevant requirements, standards legislation respect configuration safety. Beijer Electronics assumes responsibility damages that occur during installation software. Beijer Electronics hereby forbids modification software.
Beijer Electronics MA00600A
Foreword
Please fill this form with suggestions regarding manual. This page, copy sent addresses below.
Comments regarding MA00600A Page
Name Address
Company City, code. Country Telephone.Fax. E-mail
Please this page Marketing Department, Beijer Electronics +46-40-93 send conventional mail Marketing Department, Beijer Electronics 426, SE-201 Sweden. Comments also sent manuals@beijerelectronics.com.
Beijer Electronics MA00600A
Contents
Contents
Introduction System requirements Program specifications Program installation. Efficient communication. File types.
Program Structure 2.10 Project Manager Object Inspector Script Editor Properties. Cross References Dynamics Library Keyboard Shortcuts. Function Keys. Designer tips
Menus. File Menu. Edit Menu View Menu. Insert Menu. Project Menu. Layout Menu. Tools Menu. Window Menu Help Menu.
Configuration forms screens. Screens. Controller Databases: General information Data Logger Recipes. Alarm Server Security Manager Script Modules.
Beijer Electronics MA00600A
Contents Static Graphical Objects General Properties. Line Rectangle Ellipse Arc. Polyline. Freehand. Text User-defined grouped objects.
ActiveX Objects Adding ActiveX Objects.
Windows Objects General Properties. Check Combo Edit Box. List
Dynamic Graphical Objects 8.10 General properties. Analog Numeric. Button Multi Symbol. Multi Text Bargraph Slider Meter Trend. Picture
Other Objects Alarm Viewer. Timer. Browser
Beijer Electronics MA00600A
Contents Runtime. 10.1 10.2 10.3 10.4 10.5 10.6 Controller Tool Operation Autostart project Printing screens. Trend History. Windows Access.
Beijer Electronics MA00600A
Introduction
Introduction
This manual describes menus, configuration forms objects configuration tool CEZAR 2.0. manual assumes that reader familiar with Windows operating system. Programming accomplished using properties dialogs, Object Inspector Script Editor, dependant user's programming experience. those choose program Script Editor, solid knowledge Visual Basic Script required, since this syntax followed. Beijer Electronics provides scripting support. addition this manual, User's Guide with user-friendly step-by-step instructions also included program
System requirements
Hardware software Operating system Recommended Windows Workstation 4.0, Build 1381: Service Pack Windows 2000 Professional Windows Professional Pentium Internet Explorer later
Processor Installed software
Available space hard drive
Program specifications
Parameter Description Signals (data items) 2048, dependant license purchased. Internal variables Graphical user interface 2048, dependant license purchased. Screens created using predefined objects. also possible ActiveX objects from third-party providers. ActiveX objects objects with specific property settings saved library reuse. software provided with server that includes drivers most manufacturers controllers other automation equipment. Several servers used same time, also possible servers from third-party vendors. Recipes created, changed saved database. Alarms defined analog digital signals. These grouped, example, priority. Alarms displayed Alarm Viewer, where alarms also searched sorted. Alarms saved database. Data Logger used store values database, controlled time event. security level assigned objects. Operators assigned various authorization levels individual passwords. software communicate with various standard databases, such Server, Oracle, dBase Microsoft Access. Microsoft Visual Basic Script used application development. Please note that Beijer Electronics provides scripting support.
Drivers
Recipes Alarm Server
Data Logger Security Manager Database support Scripting language
Beijer Electronics MA00600A
Introduction
Program installation
When placed CD-ROM drive, select install different versions program: Demo, Development Runtime. Additionally, manuals available.
CEZAR Demo version
possible work with configuration tool Demo mode minutes with full program functionality. project into Runtime mode minutes test project. possible save project continue working with during unlimited number 30-minute sessions. license number required running Demo version.
CEZAR Development version
Development version contains configuration tool that used create project. license number required. minutes Runtime mode included testing project.
CEZAR Runtime version
Runtime version used project. license number required install Runtime version, dongle used project. number data items that used, 2048, determined dongle. CEZAR project created tested Development version. project then transferred where application run, using Project/ Transfer function.
Efficient communication
performance project depends many different parameters, which many driver-specific. Additionally, connected controller executes controller program prior communicating, which means that performance problems originate from controller program. further information refer driver controller documentation. also section Server.
Batch operations
Batch operations used optimize read write operations when many items written read from server. procedure BatchStart called controller enter BatchMode, calls BatchWrite BatchRead cached batch. Then BatchCommit BatchCommitAsync called perform actual write read operations server. When batch committed data items batch with same UpdateRate (which means that they same group) sent single write read command. more than 1000 items written read, they divided into commands 1000 items.
Beijer Electronics MA00600A
Introduction following procedures used controller object:
Procedure BatchStart Description Tells controller BatchMode. After that BatchWrite BatchRead called data items that written/read batch. Calling BatchStart more than once causes error. BatchStart cannot called while BatchCommitAsync operation progress server. When BatchCommit called batch operations performed synchronously, which means that function does return until values written/read. Note: error caused BatchStart been called. When BatchCommitAsync called batch operations performed asynchronously, which means that function returns immediately values written/read background. When server finished requested operations event BatchCommitAsyncComplete fired. Note: error caused BatchStart been called. batch operations since controller entered BatchMode cancelled. Note: error caused BatchStart been called.
BatchCommit
BatchCommit Async
BatchCancel
complete read operation performed this example.
Note: BatchCommit method automatically used recipes.
Beijer Electronics MA00600A
Introduction
File types
following file types used application:
File extension .czr .czp Description file associated with runtime version CEZAR. Double-clicking this file will start project runtime. project file. This file tells program which objects (screens etc.) that included project. project settings made Project Properties also stored here. objects application (screens etc.) saved separate files with .czx extension. .czx files text files. data object that cannot saved text, e.g. pictures, will saved additional file with same name with .czxs extension. Backup files marked with beginning extension.
.czx .czxs
.~czx
files necessary during development well runtime project function correctly.
Beijer Electronics MA00600A
Program Structure
Program Structure
What displayed application window depends project functions. Objects placed screen window assigned various properties. These properties linked various settings. right-clicking object configuration form, available choices displayed. program windows displayed using various layouts choosing desktop setting. section Desktops. Several program windows docked various locations, either horizontally vertically, become part configuration tool. Dragging dockable window while pressing Ctrl-key makes possible place window anywhere without docking. right-clicking window title bar, option Dockable displayed. Dockable been deselected, window obscured active foreground windows only visible placed unoccupied area application window. Colors windows determined Windows system colors, which selected under Start/Settings/Control Panel/Display/Appearance.
Project Manager Object Inspector docked each side working space, where screens controller form open editing.
Objects
Objects automatically assigned object names numbers, which changed either Object Inspector object's properties dialog.
File names
File names files related project contain more than characters. Non-valid characters spaces automatically replaced with underscore (_).
Beijer Electronics MA00600A
Program Structure
Project Manager
project components managed Project Manager. addition screens, there several configuration forms special processing storage signals values project, such alarm processing.
Screens configuration forms available from Project Manager. Project components added, deleted have their names changed Project Manager. Some options available right-clicking project components.
Select start-up screen automatically display that screen when project loaded runtime. Double-click screen Project Manager display that screen. When configuration form double-clicked, properties dialog displayed. configuration forms described chapter Configuration forms screens.
Beijer Electronics MA00600A
Program Structure
Project properties
Some properties double-clicking project tree structure.
Settings that determine application will behave runtime made under Application Window tab.
start-up screen stated under Application Object tab.
Beijer Electronics MA00600A
Program Structure
Properties Data Connection, Database Compression Tool, Line Printer, Touch Screen Keyboard Windows Access specified under Settings tab.
Data Connection
display data connections uncertain quality selecting Data Connection clicking Edit Settings.
Quality Uncertain
Description Indication signals read program. When reading signals failed.
Database Compression Tool
Microsoft Access Databases automatically compressed with interval hours. compression disabled setting compression interval
Beijer Electronics MA00600A
Program Structure
Line Printer
choosing Line Printer from list then clicking Edit Settings, total printed rows page specified which printer use.
Note: LPT1 LPT4 always available selection Line printer. check whether ports available computer made.
individual alarm item alarm server printed, option Printer checked. section Alarm Item Properties information. selecting Line_Printer action object under Dynamics/Action properties dialog, following action types available.
this example, printer dialog displayed clicking Button4.
Action type PrintPage PrintText Description Prints current page sending FormFeed command printer. Prints value data item text specified Parameter Settings.
ShowPrinter Displays Windows printer dialog. Dialog
also chapter 10.4 Printing screens.
Beijer Electronics MA00600A
Program Structure
Keyboard Settings
Settings graphical keyboard, that most often used touch screens, made selecting Touch Screen keyboard clicking Edit Settings.
Option keyboard Popup keyboard automatically Position keyboard automatically Adjust keyboard type automatically Keyboard type alphanumeric input
Description graphical keyboard used. Displays graphical keyboard automatically when objects Analog Numeric, Edit dialogs regarding recipes (save, load delete) selected displayed. Positions graphical keyboard automatically object which data entry expected. keyboard type adapted input field. Simple alphanumeric keyboard: Displays only numeric keys. Full keyboard: Displays full keyboard.
Beijer Electronics MA00600A
Program Structure keyboard displayed hidden selecting Keyboard action object under Dynamics/Action properties dialog.
this example, keyboard will displayed clicking Button3.
Action type HideKeyboard ShowKeyboard Hides keyboard. Displays keyboard. Description
Windows Access
information, chapter 10.6 Windows Access.
Beijer Electronics MA00600A
Program Structure
Object Inspector
Object Inspector used basic settings. With just exceptions, object settings accessible. objects have different property configurations.
Properties
Each object's appearance function altered Properties settings. This done either entering values fields using button similar component right, where drop-down menus displayed with available options.
Events
Under Events tab, list displayed with events available object. conditions necessary number events occur specified objects. When specific event occurs (such mouse-click object), event procedure executed object change color, example). overview events, section Action.
Object Inspector Properties Events tab.
Beijer Electronics MA00600A
Program Structure
Script Editor
users with solid knowledge script programming, scripting also alternative.
Note: Using scripts recommended only experienced users. Beijer Electronics provides scripting support.
Scripts written Script Editor, displayed right-clicking object selecting Edit Script from View/Tools menu. scripts displayed also Cross Reference tool.
Fundamentals
script handling based event handlers. event handlers procedures that will executed when certain event triggered from object control. procedure named sequence statements executed unit. example, Function types procedures. event handler script procedure with name composed from object name event name that handles. example, procedure Button1_Click will executed when Click event triggered Button1 object. included objects edited screen available Objects combo box. When object selected, events this object listed Events combo box.
Objects combo left Events combo right. When event selected, empty event handler added script. Empty event handlers that added this removed when script editor closed event handler another object added. Program coding divided screens. Each screen script context, where events from objects that screen will handled. This also means that cannot write event handler Screen2 handle event from object Screen1. Code entered outside event handler becomes global, will executed when screen loaded. access procedures other screens, screen name entered before procedure name. call, example, procedure Test Screen1 from Screen2, simply write Screen1.Test. Variables declared with statement global area script context also accessed this according following example.
Beijer Electronics MA00600A
Program Structure
Global script entered Screen1.
Procedures buttons Screen2. object that event handlers Script Editor removed, will shown italics Object combo box. event handlers removed from script when object deleted. object with same name deleted added, object will execute event handlers deleted object. Clicking Ctrl+Space opens list with available objects. After selecting object from list, type display list with properties procedures that object.
built-in programming presents lists available options. Program code errors registered until project Runtime mode. programming conventions comply with syntax Visual Basic Script. more information, refer Microsoft Windows Script page Microsoft help files Visual Basic included this installation available needed.
Beijer Electronics MA00600A
Program Structure
Properties
When configuring project, properties objects configuration forms many ways. most common methods described below.
Properties for.
Double-clicking object opens properties dialog which most object's properties changed defined. properties, categorized under separate tabs, vary widely between different objects.
Checking Instant Update makes settings apply immediately. several objects selected same time, only properties that common selected objects will displayed properties dialog. This useful when example appearance property changed several objects.
Note: Object Inspector recommended simultaneously changing common properties several objects.
Beijer Electronics MA00600A
Program Structure
Cross References
Cross Reference tool available from Cross Reference toolbar rightclicking most objects. also displayed using keyboard shortcut Alt+X. tree view components project then displayed, well every object connected other objects.
tree view modified using buttons.
Button Properties Expand Contract Find Select root Description Displays properties dialog selected object, screen data item. Expands folders tree view. Contracts folders tree view. Opens search tool finding objects data items within project. also section Find tool. Another root than application root selected reduce number objects displayed cross reference window.
Additionally, possible show only objects with references, using radio buttons bottom window.
Note: keyboard shortcut Alt+R used refresh objects displayed Cross Reference tool.
Beijer Electronics MA00600A
Program Structure
Dynamics
Dynamic settings made objects configuration forms. General descriptions these settings provided following section. Dynamic setting made under separate Properties dialog. Dynamics five sub-tabs: Property, Action, Size Move. These functions used define conditions implementing action when defined event occurs.
object example shown hidden depending value digital signal.
Property
Settings property will modified when properties value fulfills chosen criteria made under Property tab.
this example back color ellipse changed using digital signal. When digital signal Light set, back color red, when reset, color turns green.
Beijer Electronics MA00600A
Program Structure field value from, property's value selected screen, configuration form object tree structure. tree structure's first level, addition screens configuration forms, Parent Self. Under Parent property values screen group location selected object. choosing property values Parent, reference will relative. This makes possible copy object without needing adjust references. Under Self property values selected object. choosing property value Self, reference processed internally within object therefore copied other locations project without needing adjust references. application Parent screens, objects screen, screen Parent. objects group, group Parent. internal external value/signal associated property field value from. Next, condition specified (Get value when) that must fulfilled property modification applied. Other settings vary depending objects properties chosen. which signal value affects object defined field Conversion type.
Conversion type
Conversion type Conversion Interval Text Integer Color OffsetGain MoveX MoveY SizeX SizeY Description Value used without conversion function. text string displayed when value within specified range. Specifies colors specified range. selected value range changed factor and/or offset. object moved horizontally. These settings also made under Move tab. section Move. object moved vertically. These settings also made under Move tab. section Move. object' width changed. These settings also made under Move tab. section Size. object' height changed. These settings also made under Move tab. section Size.
Events associated several properties; these marked Properties list. Associations deleted from selected property clicking Delete Association.
Beijer Electronics MA00600A
Program Structure
Action
Conditions implementing actions under Action tab.
this example, recipe Brownies will loaded when clicking Button1. first event event) defined that will trigger action, such mouse keyboard activity. Then select which object affect (Action object). actions that available that object then listed Action type drop-down list. contents list varies with selections made other fields. When settings above made event, event added list clicking Add. After this, settings next event defined. fields settings event, Action type Action object cleared clicking Clear. Changes made selecting event list clicking Update. option Show actions selected, events defined under other tabs will also displayed.
Note: ActiveX objects added, events that described available.
Events
events table below available objects. Events that apply specific objects listed each object, mainly chapter Configuration forms screens.
Event Click DblClick Initialize KeyDown KeyPress KeyUp MouseDown MouseMove MouseUp Click object. Double-click object. When object loaded. pressed. pressed held. released. Mouse button pressed. Mouse movement. Mouse button released. Description
Beijer Electronics MA00600A
Program Structure
Action types
Action types specific objects listed each object, mainly chapter Configuration forms screens. certain action types, additional values parameters must specified. This done Parameter Settings field. Some action types available application. These displayed selecting Application action object Dynamics/Action.
this example, Button6 used close application.
Action type CheckSecurity Close Description Checks security level object stated Parameter Settings. Closes application.
objects such buttons edit action type SetFocus available. This highlights selected object runtime, which useful when wanting guide operator screen.
Beijer Electronics MA00600A
Program Structure
this dialog, event specified screen, program search path Internet page initiated Runtime mode. screen, program Internet page opened when defined event occurs specified under Destination. screen selected, screen displayed specified field. Execute program selected, search path specified program exe-file); file associated program (for opening program with specific file); Internet address (for opening browser with particular page). file opened associated program, path program file entered upper field search path file lower field Parameters. also possible execute additional functions using this field. These functions dependent specified program. more information, manuals from respective software vendors. When settings event completed, they saved list clicking Add. Existing settings changed selecting them list clicking Update after making changes. field cleared clicking Clear.
Example: When Button4 clicked, Welcome screen opened.
Beijer Electronics MA00600A
Program Structure
Size
settings made under this affect properties relating object size. width height object changed reflect value data item.
this example width Rectangle1 changed when MyDataItem4.Value changes. When value data item width rectangle when value data item 100, width rectangle 550. This example used illustrate graph.
Parameter Value from Value from/to Width/Height from/to Description Selection which object object property value from. value object stated Value from. width graphical object that will influenced. Clicking button will adjust value edit actual width graphical object. Clicking button will adjust width graphical object according value entered edit box. Origin Selection which direction change object size.
Value when Selection condition that will trigger change size.
Note: These settings also made under Dynamics/Property tab. Changes made under automatically changed under other.
Beijer Electronics MA00600A
Program Structure
Move
settings made under this affect properties relating object placement. position object changed reflect value data item.
this example Group8 image elevator) moves screen value data item Elevator changed. When data item value position group 100, when data item value 100, position group 150.
Parameter Value from Value from/to From/To position Description Selection which object object property value from. value object stated Value from. position graphical object that will influenced. Clicking button will adjust value edit actual position graphical object. Clicking button will adjust position graphical object according value entered edit box. Origin Selection which direction change object position.
Value when Selection condition that will trigger change position.
Note: These settings also made under Dynamics/Property tab. Changes made under automatically changed under other.
Beijer Electronics MA00600A
Program Structure
Library
Library, objects groups objects saved reuse other locations project other projects. installation contains objects such buttons switches divided into folders.
Drag Help-object screen information about customize objects folder. selected library object dragged into screen. graphical object screen added into library right-clicking selecting Copy, then right-clicking library selecting Paste, using keyboard shortcuts Ctrl+C Ctrl+V. object also dragged into library folder pressing Alt-key same time object dragged. library folders added right-clicking library selecting Catalogue/New.
Three grouped objects added into library folder created user. library object displayed Library window icon with text beneath. right-clicking icon, choose display only text, only icon, both. Scripts also saved library. Right-click highlighted program code Script Editor, select Copy, right-click Scripts folder library select Paste.
Beijer Electronics MA00600A
Program Structure
Keyboard Shortcuts
Standard Windows keyboard shortcuts, such Ctrl+C copy used. combinations that useful when designing screens listed table below.
combination Description
Ctrl+click drag Copies object group objects within same screen. Alt+click drag Ctrl+drag Ctrl+Z Ctrl+Shift+Y Ctrl+Shift+Z Ctrl+Y Ctrl+F Gr+drag Copies object group objects another screen library. Allows placing dockable program window application window without docking. Within screen, most recent changes undone. maximum undo-operations redone. Displays Find tool when properties window active. cursor changes appearance when pressed. When editable text property found, cursor changes I-beam form (in-place edit function). grouped objects, Gr+click allows editing individual objects group. Sets order objects screen. section Order. Shift-key held down same time object edited screen, object proportions kept. example, circular Ellipse object stays circular instead becoming ellipse. configuration tool, objects will behave they will Runtime mode. Displays cross references tool. root tree view depends which object selected when using combination. Refreshes cross references window.
Ctrl+I Shift
Ctrl+Shift Alt+X
Alt+R
Function Keys
Function Displays appropriate help section determined cursor position. In-place edit allows editing text selected object (e.g. button label) without opening properties dialog. Search function Starts Runtime Displays list objects that included selected group. Each grouped objects selected edited Object Inspector. Displays Controller tool with status information controller.
Beijer Electronics MA00600A
Program Structure
2.10 Designer tips
Find tool
From Controller properties window, displayed double-clicking controller Project Manager, Find tool available clicking Find button. Enter name item search for, check Match whole word only Match case-boxes desired. Click Find display data items that matches search criteria. Clicking will highlight data item location controller. Pressing will next matching data item.
Data items located easily using Find tool.
Adding multiple objects same kind
number objects same kind, without having select object toolbar again, hold Shift-key down while selecting object toolbar. object will stay selected until another object clicked toolbar.
Special Characters
insert special characters, such Character application selecting Map.
Dimensions
dimensions specified pixels. Dimensions will vary depending monitor used selected resolution (pixels centimeter).
Beijer Electronics MA00600A
Menus
Menus
This chapter describes various menu commands. Many menu commands selected using keyboard shortcuts shown along right edge each menu.
Toolbars
Many commands available toolbar buttons. tooltip, explaining each toolbar button, displayed cursor placed button. toolbars either viewed hidden.
toolbars displayed from View menu.
Standard Toolbar used functions such open, save, copy, paste undo. These commands also available from File- Edit menus.
project into Runtime mode, then stopped, using Toolbar.
Font Toolbar used select font, font size, font style text alignment. text properties correspond settings such Header Font Scale Font that made Object Inspector.
Align Toolbar makes easy arrange multiple objects screen neatly.
Layout Toolbar used group objects, send objects front back another, rotate objects different ways. There also buttons editing points polyline objects. Grid settings also made.
Setting back- fore color objects made using Color Toolbar. Other color selections objects made properties dialogs, Object Inspector Script Editor.
Beijer Electronics MA00600A
Menus
Values from external devices (hardware software) well internal variables connected objects using Data connection Toolbar. data source from which signal retrieved selected left-hand field, individual signal specified right-hand field. section Controller further information.
Personalized well default settings application window chosen from Desktop Toolbar. section Desktops further information.
Cross reference Toolbar used display cross references within project particular object. chapter Cross References further information.
Note: Viewing preferences toolbars saved desktop configurations described section Tools Menu.
Beijer Electronics MA00600A
Menus
File Menu
Projects created, saved opened from File menu. most recently used projects listed File menu. maximum number listed projects defined under Tools/Options/General Settings. section Tools Menu.
Create project
Create project selecting File/New. State Controller system project Screen size Project dialog. projects unnamed. first time project saved, will prompted enter project name. Certain settings selected external device made clicking Settings. settings available vary depending selected controller. details, section Server.
Settings made when creating project changed later from Project menu.
Update drivers
update available drivers latest version, install drivers, select File/ Update Drivers/From Internet From Disk. projects must closed before this function used. must able connect Internet From Internet selected, browser required. list drivers which downloaded displayed when Internet connection established.
When installing drivers from disk, browse folder where drivers saved. Select which drivers install. Click Mark newer select drives available newer versions than ones installed, including drivers installed. Select Download. Each driver takes approximately ready soon download completed.
Beijer Electronics MA00600A
Menus
Updating drivers runtime
Drivers easily updated clicking button runtime, using action object UpdateDriversTool selecting action type UpdateDriversFromInternet.
Beijer Electronics MA00600A
Menus
Edit Menu
Besides accessing standard editing commands, also save desktop settings from Edit menu. editing commands, such Paste also available from Standard Toolbar using keyboard shortcuts.
Desktops
configuration program's application window adapted individual needs preferences. There three options choose from: Advanced, editing space Medium. With default setting (Medium), window displayed with quite working space with Project Manager displayed. This especially suitable when using Property dialogs. Advanced setting more appropriate those program using Object Inspector Script Editor. Personalized settings also saved this dialog. Select View/Tools View/ Toolbars choose which tools toolbars display program's application window. save desktop configuration, enter name Desktop name field click Save. Default personalized desktop settings loaded clicking Load button deleted clicking Delete button.
Personalized well default desktop settings available from Desktop Toolbar.
Beijer Electronics MA00600A
Menus
View Menu
tools toolbars displayed program's application window selected from View menu. They arranged different ways within application window. toolbars described section Toolbars.
Script Editor
Programming with Script Editor suitable users with solid knowledge Visual Basic Script programming. Beijer Electronics provides scripting support. Selecting View/Tools/Script Editor displays scripts project; selecting View/ Edit script. displays scripts selected object. section Script Editor information about using Script Editor.
Project Manager
Project Manager provides overview configuration forms screens project. Project Manager described chapter Project Manager.
Library
library buttons, switches etc. provided with program installation. also possible user objects library well library folders. objects library reused other locations project other projects. further information, section Library.
Objects Tool
Default objects available from Objects Tool. Buttons added removed. button ActiveX control, right-click toolbar choose Add. remove object button, right-click button choose Remove. Objects placed screen different ways: First select object from Objects Toolbar. object either placed screen sized default size settings dragging from toolbar with cursor, click once screen object placed there. When using second method, mouse used size object.
Beijer Electronics MA00600A
Menus functions each object described separate sections according table below.
Object Cursor Line Rectangle Ellipse Polyline Freehand Text ActiveX Object Check Combo Edit List Analog Numeric Button Multi Symbol Multi Text Bargraph Meter Slider Trend Picture Alarm Viewer Timer Browser Selection tool section Line section Rectangle section Ellipse section section Polyline section Freehand section Text chapter ActiveX Objects section Check section Combo section Edit section List section Analog Numeric section Button section Multi Symbol section Multi Text section Bargraph section Meter section Slider section Trend section 8.10 Picture section Alarm Viewer section Timer section Browser Reference Icon
Beijer Electronics MA00600A
Menus
Object Inspector
functions appearance object changed various ways using Object Inspector. section Object Inspector information.
Properties
Opens properties dialog selected object. detailed description provided section Properties for.
Cross Reference (for Object)
Displays cross references entire project selected object. chapter Cross References information.
Status
Displays information about status controller lower edge window.
Insert Menu
project components such screens, data loggers, alarm servers script modules added project from Insert menu.
Project Menu
Program execution started stopped from Project menu. Choosing Transfer from Project menu makes possible transfer projects from, example, personal computer which application developed) industrial computer another personal computer which Runtime program will run. Selecting Project/Properties opens properties dialog project. This dialog also displayed double-clicking project Project Manager. further information, chapter Project Manager.
Beijer Electronics MA00600A
Menus
Layout Menu
Layout menu functions facilitating configuration screen layouts.
Selecting multiple objects
select multiple objects, press hold either Shift-keys while selecting objects. object with black markings so-called master object, i.e. object that adjustments based make another object master, select master object within selection while pressing Ctrl-key.
Distributing objects screen
selecting Layout/Align Objects, multiple objects aligned their left, right, bottom edges, their centers along their vertical horizontal axis. Selected objects arranged with even horizontal vertical spacing selecting Space Evenly Across Down from Layout menu. Objects furthest top, bottom sides affected. Objects centered vertically horizontally screen selecting Layout/ Center View. From Layout menu, dimensions selected objects changed that they become same size.
Order
Tab-key used shift focus between objects Runtime mode. order which selection made with this function, which deactivated choosing option False Stop property. choosing Layout/Tab Order Stop (True), selected object will receive index label.
cursor changes appearance when pressing Ctrl+I. objects with option True chosen Stop property index label. order starts from object with black index label. Right-clicking object which starts Order makes index label black. order between objects changed using various methods. clicking objects preferred order, they assigned order numbers that displayed upper-left corners objects. right-clicking object, order number changed when chosen; preferred order number entered from keyboard. order changed there many objects screen, function origin very helpful. right-clicking object choosing origin option, counting begins from this object's order number, which marked black. This useful, example, when order objects with order numbers changed. object chosen that does have Stop option selected, dialog opens with prompt activate this function (True). Stop function deactivated choosing False option properties dialog Object Inspector. leave Order settings, click screen, press Enter.
Beijer Electronics MA00600A
Menus
Grid Settings
grid displayed order design screens easily. Objects cannot placed outside grid.
Option Show Grid Snap Grid Snap Center Spacing Margins Displays grid.
Description
Objects snap grid, even when resizing. Objects centered over grid (active only when Snap Grid selected). distance between grid. Specified points, horizontally vertically. Distances from outer edges grid.
Note: When Snap grid been selected, objects still resized placed between grid lines pressed after having started move resize object.
Arranging objects screen
Objects placed front back another selecting Layout/ Arrange.
Note: Several objects selected simultaneously.
objects divided into groups, Window Windowless. Only objects from same group placed front back another. objects from different groups, Window object will always placed foreground. following list shows group which various objects belong.
Window Alarm Viewer Button Check Combo Edit Timer Trend Browser Bargraph Ellipse Freehand Line Windowless Meter Multi Symbol Multi Text Picture Polyline Rectangle Slider
Analog Numeric List
Beijer Electronics MA00600A
Menus
Grouping objects
Grouping objects made selecting Layout/Group. group treated object. Regardless objects that included, available properties group same. Group, Ungroup Edit Group also accessible from rightclick menu. Objects grouped levels; group contain several grouped objects. Properties individual object within group changed pressing right-clicking selecting Edit Group when group selected. list objects included group displayed. When object chosen from list, corresponding object selected screen with handles marked gray. Properties selected object displayed Object Inspector, selecting from list clicking properties dialog shown.
Option Group Ungroup EditGroup Description group objects, select them choose Group command. grouped objects treated single object that resized. Separates grouped objects into individual objects. Changes single object group made. dialog containing objects group displayed when this option selected.
Rotating objects
Select Layout/Rotate rotate selected object around specified point. center point normally chosen, with option Free Rotate, rotation point moved. This done selecting object choosing Layout/Rotate/Free Rotate; appearance cursor will then change. rotation point moved when this cursor displayed.
Note: Only works with static graphic objects; with Line objects. function used with Polyline object, end-points joined object filled with color. Note: gradient colors shadowing chosen object, these will disappear object rotated. They will displayed only object original position. Option Free Rotate Unrotate Rotate Right Description Rotation position grabbing selection markers. Resets object original position (with exception Line, which shifts horizontal). Object rotates degrees clockwise.
Contour
Contour tool used modifying irregular graphic objects, such Polyline Freehand objects.
Option Edit Points Description object's contour changed grabbing points pulling. points also added clicking dragging. pressing Ctrl points deleted. End-points opened closed.
Open/Close
Beijer Electronics MA00600A
Menus
Tools Menu
Select Tools/Options open dialog general settings program.
Script Editor visual properties
Select Script Editor make settings Script Editor visual properties.
Option Description
Indent automatically Indents text code window. Syntax coloring width Font Color Text script window having various functions assigned different colors making selections under Color. Number character-spaces tabs. Selection font, font format font size text code window. Color selections various script texts.
General Settings
Select General Settings specify number recently used projects that displayed File menu. Checking Reload last project opens most recently used project program start-up.
Designer Settings
General settings options various configuration forms made from Designer Settings tab.
Controller
Option Description
DataItems warning- Specifies when display warning message that number level available data items about exceeded. still possible data items after warning message been displayed. default setting maximum number items available. data item automatically Confirm automatic addition Permits name item entered directly field under Data Connection each object. This makes button unnecessary. Selected default. Properties dialog selected item will displayed automatically when item added. selected default.
Settings
Under Settings possible determine project saved before entering Runtime mode.
Note: project must saved order settings used Runtime.
Tool Settings
tamper with Tool Settings unless told support technician from Beijer Electronics.
Beijer Electronics MA00600A
Menus
Window Menu
Window menu used specify window arrangements program windows. Select Cascade program windows overlap another, Tile tile undocked program windows above other. list open windows displayed. Management open windows made selecting Window/Windows.
Help Menu
help topics displayed selecting Help/Contents, Help/Search Help/Index. Users have installed demo version program subsequently obtained license register entering their license number under Help/Register. controller help, Controller Properties dialog, select controller system click Settings. Properties dialog controller, click Help. Selecting Help/About displays program version information.
Beijer Electronics MA00600A
Configuration forms screens
Configuration forms screens
This chapter provides descriptions various configuration forms screens. configuration forms process values signals visible Runtime mode. configuration forms screens available from Project Manager.
Project Manager with configuration forms different folders.
Screens
screen window where graphical objects, displayed Runtime mode, placed. properties events each object define functions. screen automatically added whenever project created.
Screens designed configuration tool. screens created project placed screen folder Project Manager. screen created either right-clicking screen folder choosing Screen, importing existing screen (from previous project, example) with Import from file. project include several screens. Right-click screen, select start-up screen automatically display that screen when project loaded Runtime mode.
Beijer Electronics MA00600A
Configuration forms screens
Screen Properties
Right-click screen Project Manager select Properties display Screen Properties dialog. Window selected below.
Window
Property Title Show title Window style Always Show Modal state Dockstate Description State title text displayed top-left corner screen Runtime mode. When checked (default setting) title displayed. options screen style Runtime mode FullScreen (default setting), PopUp Dockable. When checked, screen always foreground Runtime mode. Only available when PopUp selected Window style. When checked, screen must closed access other screens project Runtime mode. Only available when PopUp selected Window style. options screen docked Runtime mode None (default setting), Left, Right, Top, Bottom Floating (before screen docked). Only available when Dockable selected Window style.
Position, Size, Different parameters properties such position, size, butShow System menu tons system menu scroll bars available depending Size move Window style settings.
Picture Color
background picture screen selected. display picture tiled manner, select Tiled PictureStyle Object Inspector. icon also selected (only valid PopUp screens). Select background cursor color under Color tab.
Beijer Electronics MA00600A
Configuration forms screens
Extended
Parameter Name Load automatically start-up Access
Description Select name screen. default name Screen1. When checked, screen loaded Runtime mode, displayed more quickly. Security level screen Runtime mode. object accessible users value (default setting). information, section Security Manager.
Note: Selecting option Load automatically start-up many screens will influence performance start-up.
Dynamics
properties under Dynamics/Property correspond properties listed above. addition, following properties available:
Property ClientHeight ClientWidth CursorBlink CursorColor CursorWidth Sets appearance runtime cursor that indicates object that currently keyboard focus. Description size actual screen, exclusive borders, title etc.
Beijer Electronics MA00600A
Configuration forms screens following screen events available under Dynamics/Action /GoTo tabs:
Event Activate Close Deactivate Hide Show screen activated. screen closed. Focus released from screen. screen hidden. screen displayed. Description
When screen selected action object event e.g. button, following action types available.
Action type Activate Hide Load Maximize Minimize Print Restore Show ShowPrinter Dialog screen activated. screen hidden.
Description
screen loaded RAM, displayed, quicker access running scripts. available AutoLoad selected. screen maximized. screen minimized. screen printed Windows default printer. screen size restored size before maximized minimized. screen displayed. Windows printer dialog displayed selection another printer than default printer.
Beijer Electronics MA00600A
Configuration forms screens
Controller
When project created, controller form automatically created along with form internal variables. Double-clicking controller Project Manager displays Controller form.
Controller Form
settings connecting external devices (data sources) their signals configuration software made Controller form. able communicate with data source, server drivers required. Controller form must created each external unit that connected configuration tool.
Form Internal Variables
settings correspond settings controller form, these signals processed internally within program. internal variables used limit spending external data items. internal variable can, example, used trigger logging data items. Using internal variables will strain connection external controller.
Beijer Electronics MA00600A
Configuration forms screens
Server
Click Properties when controller selected Controller form display following dialog. Alternatively, right-click controller Project Manager select Properties.
Parameter Server
Description Choice Server. default Server CEZAR InProcess Server. Choice driver. default driver DEMO. Browse configuration file when alternative brand server been selected.
Remote server node Path server another within network. Controller system Configuration file
application provided with server CEZAR InProcess Server along with drivers number different control systems automation equipment. Settings processing external signals made Controller properties dialog, under Server. other servers installed computer, these will also available list. server another computer within network also used entering search path field Remote server node.
Drivers
Normally, server connected only type controller, while CEZAR InProcess Server connect several. These chosen from list Controller System. clicking Settings button, dialog opens with settings selected driver. contents dialog vary depending selected driver. Detailed help information each driver available pressing When server other than CEZAR InProcess Server chosen, field Configuration file used specify search path file that configures server, provided that server supports this method.
Beijer Electronics MA00600A
Configuration forms screens
Dynamics
Dynamic settings made controller under Dynamics with three tabs.
Besides properties under Server Extended tabs, following properties also available under Dynamics/Properties tab:
Property Active Loaded Description Determines driver built-in server connected device. Active False (the device connected). object loaded into memory.
following events available under Dynamics/Action /GoTo tabs:
Event ServerError BatchCommit AsyncComplete Description Error signal from server. When server completed operations requested through BatchCommitAsync procedure. section Batch operations.
Beijer Electronics MA00600A
Configuration forms screens When controller selected action object event e.g. button, following action types available.
Action type BatchCancel BatchCommit BatchCommitAsync BatchStart Load
Description Actions used optimize read write operations with many data items. section Batch operations information.
Only applicable screens.
Beijer Electronics MA00600A
Configuration forms screens
Data types
data type data item selected automatically. following data types used:
Data type Default Signed 16-bit Signed 32-bit Float 32-bit Float 64-bit Date Time String Boolean Unsigned 16-bit Unsigned 32-bit Description server chooses data type Integer from -32,768 32,767 Integer from -2,147,483,648 2,147,483,467 Float from -3.4E+38 3.4E+38 Float from -1.79E+308 1.79E+308 Date time data Characters (letters and/or digits) True (=1) False (=0) 65,535 4,294,967,295
Adding data items
Individual signals from data sources added clicking Controller form. Data Items dialog displayed.
Adding individual data item.
Beijer Electronics MA00600A
Configuration forms screens number data items easily added controller clicking Generate.
Adding range data items (D12-D21) named MyDataItem0, MyDataItem1, etc.
Parameter Name Address/ Item Data type Size Description Select name data items added. After name, individual data items will given number. Select first address range data items added. data type different from default data type selected from list. Maximum number characters when data type String selected.
Poll Interval/ Interval between reading signal values. default value Update rate Active options logging values from external devices True (continuous logging), False logging) Auto (values updated only when connected objects visible screen continuous logging required, such trend). default setting Auto. Applies only Runtime mode. State number data items consequtively, following data item stated Address field.
Count
Note: able script data item event object that visible screen moment, Active property True.
incoming signal values from external devices converted specific range that provides representative values. clicking button (Offset Gain Calculation), preferred value range specified. Conversion factors calculated automatically presented Calculated Offset Calculated Gain.
Beijer Electronics MA00600A
Configuration forms screens update rate data items affects, among other things, performance project. longer poll interval than default might sufficient many cases. update rate group data items changed once selecting them Controller form clicking Properties.
Clicking Properties will allow setting another update rate selected data items.
Beijer Electronics MA00600A
Configuration forms screens
Dynamics
addition properties under DataItem Properties tab, following runtime properties available under Dynamics/Property tab.
Property Active Quality RawValue Value Description options logging values from external devices (True, False Auto) described section Adding data items. information, www.opcfoundation.org. Data item value without modifying factors Offset Gain. Data item value.
following events available under Dynamics/Action /GoTo tabs.
Event ValueChange ValueChangeOrError ValueOff ValueOn
Description When vaule data item changes. When vaule data item changes value cannot read. When value data item When value data item
Beijer Electronics MA00600A
Configuration forms screens When data item selected action object e.g. button, following action types available.
this example value MyDataItem4 will increased clicking Button1.
Action type BatchRead BatchWrite Decrease Increase Read Reset SetValue Toggle Description Caches data item batch written when Batch Commit BatchCommitAsync procedure called. section Batch operations information. value data item decreased value specified Parameter Settings. value data item increased value specified Parameter Settings. Reads value; event executed only value changes. Resets value data item (can either analog digital). Sets value data item, non-synchronous. Sets value data item according value specified Parameter Settings. Each time influenced, signal status changes from (0), vice versa. used objects that connected data item. Sets value data item according value specified Parameter Settings, synchronous.
Write
Beijer Electronics MA00600A
Configuration forms screens
Data item import export
properties individual signal from external devices (data items) exported file. saved property settings later imported resuse same project another project. Clicking Export. button Controller properties dialog opens dialog Export data items file.
Select file name destination exported data items field Export file. Then select character that will separate information columns field Column separator. available properties listed left under Available properties. clicking properties will added list properties exported (Export properties). With only selected property added list. properties order list export file modified list using Down buttons. clicking Export, information saved file location specified search path.
Beijer Electronics MA00600A
Configuration forms screens import corresponding data achieved clicking Import. controller properties dialog.
Select file type; Text file Developer MELSEC MEDOC file. file imported specified field Import from file. State path, browse button right-hand side. Then select character that will separate information columns field Column separator. Selection properties import made similarly export procedure described above. properties available selection only when Text file selected. Exclude column button exclude columns import file. This useful when properties source file match data item properties project. Click Import data items project.
Beijer Electronics MA00600A
Configuration forms screens
Databases: General information
Values from recipes, trends alarms stored common database, data items connected Data Logger. Depending which configuration form database tables created different column configurations will created.
more information which functions used with values tables, documentation that accompanied software.
Data Link Provider
default database Microsoft Access Microsoft Access 2000 also selected. When either these selected, tables created .mdb-format, even Microsoft Access installed computer. However, configuration forms with database associations, alternative database selected properties dialog under Data Connection choosing option Connection String. clicking Connection button, Data Link Provider window opens settings made database processing. Connection databases such Oracle, Server other data source possible since CEZAR support open interface (OLE DB). section Using other databases information.
Beijer Electronics MA00600A
Configuration forms screens
General database properties
When completing configuration form with database association, click Check database. under Database Connection tab. dialog confirming that database been successfully created displayed after check database, tables columns completed.
configuration forms that connected databases (Data Logger, Recipe, Trend Alarm Server) have some properties common. These listed below. Specific properties listed each form.
Property Access Database Filename Connection string Confirm automatic changes Table Maximum number stored records Description Select type Access database, file name database. browse-button save database location other than current project folder. State data base connection string when using database connection other than Access Access 2000. Displays dialog confirm addition columns database tables. checked default. Table name database. When using several recipes data loggers, tables have given different names. Maximum number stored values. After this number reached, oldest record removed added. default value 5,000.
Beijer Electronics MA00600A
Configuration forms screens checking Confirm automatic changes, dialog displayed listing items add, asking columns should created them. selected default, selections cleared. similar dialog shown when database association created.
option Confirm automatic changes selected default, which means that check made columns added without displaying dialog.
Using other databases
When using other databases, Connection string selected under Database connection instead Access Database Filename.
Server
Perform following steps configure Microsoft Server database connection: Create database Server right-clicking Databases folder, then select Database. Choose name database click
Start CEZAR open your project. Right-click DataLogger Project Manager select Properties open data logger properties window, select Database connection tab.
Beijer Electronics MA00600A
Configuration forms screens Select Connection string.
Click Connection button, choose Microsoft Provider under Provider tab, click Next.
Select enter server name, indicating name computer where Server installed.
Note: using Windows computer name must entered manually.
Note: Server located remote computer, same account must valid both computers.
Beijer Electronics MA00600A
Configuration forms screens Select Windows Integrated security. (This choice could different your site depending your system configured). Select Select database server select database that created earlier, click Test Connection.
Click then again. Click Check database. Providing that everything order, following message displayed:
database created with table current columns.
Beijer Electronics MA00600A
Configuration forms screens
Data Logger
Signal values from external devices registered database, using Data Logger. Logging made different time intervals example, triggered event object. data logger added project either choosing Data Logger from Insert menu right-clicking folder Data Loggers Project Manager.
default database format .mdb (Microsoft Access), other formats used. Individual values (data items) added Data Logger clicking Add. Select item, then click Properties select properties such database field name controller data item item.
Note: maximum items added Data Logger.
Data Logger Properties
properties below listed they presented Object Inspector. same properties, under similar names, available right-clicking Data Logger Project Manager selecting Properties. section General database properties similar properties dialog.
Property (Name) LogIdFieldName LogTimeField Name LogTimerInterval LogTriggerEvent Description Configuration form name your choice. default name DataLogger1. Name database column heading. default name LogId. Field name where time displayed. default name LogTime. Interval seconds between storage signal values database. interval data stored (default setting). Specifies event object (indicated LogTriggerObject) that determines when register value Data Logger.
LogTriggerObject Specifies object/configuration form which event connected register value Data Logger.
Dynamics
properties under Dynamics/Property correspond properties listed above. following events available under Dynamics/Action /GoTo tabs:
Event AfterLog BeforeLog Description When data logging completed. Before data logging started.
Beijer Electronics MA00600A
Configuration forms screens
Item Properties
properties below listed they presented Object Inspector. same properties, under similar names, available double-clicking data logger Project Manager, selecting item clicking Properties.
Property (Name) Description Item name your choice. default name LogItem1.
DatabaseFieldName Name field database which values logged. default name LogItem1. DataItem DataSource Value Value logged signal. data item data source connected item.
Dynamics
properties under Dynamics/Property correspond properties listed above. addition, property below available:
Property Parent Description This property returns Parent object this case Data Logger).
also section General database properties. When data logger selected action object event e.g. button, following action types available.
Action type CheckDatabase Load
Description Control function columns tables database association. Only applicable screens. Logging values started.
Beijer Electronics MA00600A
Configuration forms screens
Recipes
Recipes created Recipes folder Project Manager. recipes stored database. stored configurations saved file, used, example, various operational situations facility. conjunction with creation recipe, database also created. Although default database format .mdb (Microsoft Access), other formats used. individual value linked database Recipe Item. Settings each recipe item made properties dialog, displayed double-clicking recipe item. Recipe items added deleted from recipe using buttons.
Note: maximum recipe items added Recipe.
Recipe Editor
Recipe Editor used edit existing recipe create recipes. Values changed Recipe Editor. Clicking buttons will delete records database. changes stored database, click Update button. Even Recipe Editor open, content updated clicking Update button, that correct values retrieved from database.
Update button
Recipe Editor ActiveX object that used Runtime mode. Recipe Editor Object Toolbar, right-click Object Toolbar, choose then select BERecipeEditorCtrl Class.
Beijer Electronics MA00600A
Configuration forms screens
Recipe Properties
properties below listed they presented Object Inspector. same properties, under similar names, available right-clicking recipe Project Manager selecting Properties. section General database properties description recipe properties dialog.
Property (Name) ConfirmOverwrite Description Configuration form name your choice. default name Recipe1. Displays dialog confirm overwriting previous recipe.
Dynamics
following events available under Dynamics/Action /GoTo tabs:
Event AfterRecipeLoad AfterRecipeSave BeforeRecipeLoad BeforeRecipeSave RecipeLoadFailed RecipeSaveFailed Description When recipe load complete. When recipe save process complete. When recipe load begins. When recipe save process begins. When recipe load failed. When recipe save process failed.
Beijer Electronics MA00600A
Configuration forms screens
Recipe Item Properties
Double-click recipe Project Manager display recipe properties dialog. Then double-click individual recipe item make settings recipe item. Select data item connect recipe item under Data Connection tab. Select Recipe Item display dialog below.
Property Name Database field name Format
Description Recipe Item name your choice. default name RecipeItem1. Name database column. default name RecipeItem1. options signal value formats Decimal, String (letters and/or digits), Boolean/Bit Date Time. default setting Decimal. Name presented column heading Recipe Editor. left empty, Name stated above used. Unit value that presented column heading. Placed within parenthesis after name. Minimum value signal range. default value Maximum value signal range. default value 65,535.
Editor unit name Editor column title value value
also section General database properties.
Beijer Electronics MA00600A
Configuration forms screens When recipe selected action object event e.g. button, following action types available.
Action type CheckDatabase CopyRecipe DeleteRecipe Load LoadRecipe SaveRecipe
Description Control function columns tables database association. Copies recipe from Source Destination stated Parameter Settings. Deletes recipe stated Parameter Settings. Only applicable screens. Loads recipe stated Parameter Settings. Parameter Settings left blank, Load Recipe window displayed. Saves recipe stated Parameter Settings. Parameter Settings left blank, Save Recipe window displayed.
Load Recipe dialog displayed action LoadRecipe recipe entered Parameter Settings. Similar dialogs displayed SaveRecipe DeleteRecipe.
Beijer Electronics MA00600A
Configuration forms screens
Alarm Server
Settings alarm management made Alarm Server. Alarm settings made individual signals. These arranged various groups that also assigned properties.
specify more than Alarm Server, which appropriate e.g. facility spread over several buildings. This permits alarms each building collected single Alarm Server. There four different alarm conditions, that used different configuration forms alarm management:
Alarm condition Active Inactive Acknowledged Normal Description unacknowledged active alarm. unacknowledged alarm that returned normal condition. acknowledged active alarm. alarm (e.g. acknowledged alarm that inactive).
Right-clicking Alarm Server Project Manager selecting Properties displays dialog below.
General Alarm Server properties.
Beijer Electronics MA00600A
Configuration forms screens
Alarm Server Properties
Parameter Alarm active data source data item Description Selection data item Alarm Server when there active alarm. selecting data item using browse button right Data Item field, Data Source field automatically filled
Alarm unacknowledge Selection data item Alarm Server when data source data item there unacknowledged alarm. selecting data item using browse button right Data Item field, Data Source field automatically filled Remote acknowledge data source data item Selection data item that, when from another object, acknowledges alarms Alarm Server, both active unacknowledged. selecting data item using browse button right Data Item field, Data Source field automatically filled Selection many alarms display Alarm Viewer Runtime mode. default setting 200. maximum number 10,000. options displaying symbols None, Unacknowledged, Active Both (default setting).
Maximum number alarms Alarm Viewer Show alarm symbol
Database connection
Alarms automatically logged database. information section General database properties. Functions started clicking alarm symbol. Settings selections this made under Dynamics/Action.
Picture
sets symbols active unacknowledged alarms selected example display flashing lamp swaying bell. Suitable pictures found CEZAR Graphics folder. When show alarm symbols selected under General tab.
Beijer Electronics MA00600A
Configuration forms screens
Printer Settings
Under Printer Settings property dialog columns printed number characters each column selected. Empty spaces filled with blanks.
individual alarm signal (Alarm Item) printed, printer-box checked under General Alarm Item Properties dialog.
Note: warnings displayed paper width exceeded.
Printer settings described section Line Printer.
Dynamics
properties under Dynamics/Property correspond properties listed above. following events available under Dynamics/Action /GoTo tabs:
Event Acknowledge Alarm Inactive OnAlarmSymbolDblClick Remove Description Alarm acknowledgement. Alarm enabled. Alarm becomes inactive. Double-click alarm symbol. When alarm item removed from alarm list.
Beijer Electronics MA00600A
Configuration forms screens When alarm server selected action object event e.g. button, following action types available.
Action type Acknowledge CheckDatabase ClearAlarmList Load
Description Acknowledge alarms (Acknowledge required selected). Control function columns tables database association. Removes alarms AlarmViewer. Only applicable screens.
Beijer Electronics MA00600A
Configuration forms screens
Alarm Group Properties
Property Name Comment Enabled Color Alarm active data source data item Alarm unacknowledged data source data item Remote acknowledge data source data item
Description Alarm group name your choice. default name Group0. Optional comment that displayed Alarm Viewer. When checked (default setting), alarm group accessible Runtime. Background font color selection alarms different conditions, displayed Alarm Viewer. Selection data item when there active alarm group. selecting data item using browse button right Data Item field, Data Source field automatically filled Selection data item when there unacknowledged alarm group. selecting data item using browse button right Data Item field, Data Source field automatically filled Selection data item that, when set, acknowledges alarms group, both active unacknowledged. selecting data item using browse button right Data Item field, Data Source field automatically filled
Dynamics
settings under Dynamics correspond options above.
Beijer Electronics MA00600A
Configuration forms screens
Alarm Item Properties
General properties
Property Name Alarm Text Comment Limit Deadband Description Alarm item name your choice. default name AlarmItem1. Alarm message displayed Alarm Viewer when alarm active. Optional comment that displayed Alarm Viewer. Limit value signal. option accessible digital signals. default value value determines number Trigger point Alarm limit units over/under alarm limit Reset point which alarm signal activated/deactivated. gray zone so-called deadband. trigger point reset point vary somewhat depending properties options Deadband chosen Condition. option accessible digital alarms.
Alarm signal (on/off)
Acknowledge required History Enabled
When checked (default setting), alarms must acknowledged deactivated when alarm conditions longer fulfilled. When checked (default setting), inactive acknowledged alarms kept alarm list. When checked (default setting), alarm functions accessible. Applies only Runtime mode.
Beijer Electronics MA00600A
Configuration forms screens
Property printer
Description When unchecked (default setting), alarms printed out. When checked, alarm events triggered this alarm item printed out. also section Printer Settings. Select condition alarm activation: Less than limit alarm activated when value under limit value. Deadband also affected when alarm activated deactivated. Greater than limit (default setting) -alarm activated when value over limit value. Deadband also affected when alarm activated deactivated. equal alarm activated when deviates from preset alarm limits. disable, value must return preset level. Rising Edge -anything other than Falling Edge value Selection data item reset when alarm acknowledged. selecting data item using browse button right Data Item field, Data Source field automatically filled Selection data item that, when reset, acknowledges alarm. selecting data item using browse button right Data Item field, Data Source field automatically filled
Condition
Acknowledge notify Remote acknowledge
Data Connection
Select data source data item under Data Connection tab.
Beijer Electronics MA00600A
Configuration forms screens
Dynamics
properties under Dynamics/Property correspond properties listed above. following events available under Dynamics/Action /GoTo tabs:
Event Acknowledge Alarm Inactive OnInfoButtonClicked Description Alarm acknowledgement. Alarm enabled. Alarm becomes inactive. Click alarm symbol.
this example, screen Tank_Overflow_Screen will displayed when event Alarm occurs alarm item Tank_Overflow. also sections Using Info-button Connecting Info-button particular alarm item.
Presentation Runtime mode
AlarmViewer used presentation alarms Runtime mode. information, section Alarm Viewer.
Beijer Electronics MA00600A
Configuration forms screens
Security Manager
Settings project security management made Security Manager. Users added, security levels passwords defined.
Note: Only Security Manager included project.
Authorization Levels
Maneuverable objects assigned various security levels. this way, authorization system established various operators. authorization system hierarchical with number designations. specified authorization level operator also gives access objects with lower authorization levels, i.e. level operator also access objects with levels operator clicks object with authorization level higher than what operator authorized access, password requested. buttons created logging e.g. selecting action ShowLoginDialog under button Dynamics tab. There also option automatic logout. time specified long login will remain active after operator last used program function. Security Manager displayed Runtime mode permit users added, existing users change their passwords.
button display Security Manager Runtime Mode: Select button Dynamics/Action tab, Action type: Show Action object: SecurityManager1.
Beijer Electronics MA00600A
Configuration forms screens
Security Manager Properties
General properties
Property Automatic request Login Access Denied Description When checked (default setting), login dialog opens automatically when user attempts access objects configuration forms having security levels higher than those assigned most recently logged user. When checked, message displayed denied login. checked default setting. Message displayed when login denied because incorrect user security level. default message Access Denied. Message displayed when login approved. Message displayed when login approved. Minimum number characters password, days that password valid. default values Minutes before automatic logout occurs. default value automatic logout).
Show message Access Denied Access Denied message
Login succeeded text Login failed text Password: Min. characters Validity time Auto Logout time
Beijer Electronics MA00600A
Configuration forms screens
Window
settings under Window described section Window.
Extended
Parameter Name Load automatically start-up Access Description Select name Security Manager. default name SecurityManager1. default setting, checked, cannot changed. Security level Security Manager Runtime mode. object accessible users value (default setting).
Dynamics
properties under Dynamics/Property correspond properties listed above. addition property below also available:
Property CurrentUser Description Indicates which user currently logged
following events available under Dynamics/Action /GoTo tabs:
Event AccessDenied Activate AfterLogOut BeforeLogOut Close Deactivate Hide LoginFailed LoginSucceeded Show Description When access object denied current user. When security manager focus. When user logged out. Before user logged out. Closes security manager. When focus released from security manager. security manager hidden. When login attempt failed. When login attempt succeeded. Screen Security Manager displayed.
Beijer Electronics MA00600A
Configuration forms screens When security manager selected action object event e.g. button, following action types available.
Action type Activate Hide Load LogIn LogOut Maximize Minimize Restore Show ShowChangePassword Dialog ShowLoginDialog
Description
security manager hidden. security manager loaded quicker access. user stated Parameter Settings logged current user logged out. Maximizes security manager. Minimizes security manager. Saves window size. security manager displayed. change password dialog displayed. login dialog displayed.
Beijer Electronics MA00600A
Configuration forms screens
User Properties
Property Name Password
Description User name your choice. default name User1. password field left empty development mode, dialog which password defined will open when user attempts first time. user access objects with security level lower than equal this value. default value
Security level
Dynamics
properties under Dynamics correspond properties listed above.
Script Modules
script module handles subs that associated with screen object project, which means that they used global subs. script module executed from other scripts within project, e.g. from button.
this example, Cezar_script executed when clicking Button1. script modules created project placed Script modules folder Project Manager. script module created either right-clicking Script modules folder choosing Script module, importing existing script module (from previous project, example) with Import from file. possible several subs same script module, subs divided into different script modules.
Beijer Electronics MA00600A
Static Graphical Objects
Static Graphical Objects
objects within this group used create background graphics screen. These objects most often used enhance operator environments that they easy monitor facilitate learning. Events also associated these objects. clickable static object used, example, start program.
Note: Static objects cannot placed over some dynamic objects, such Analog Numeric, Button, List Box, Edit Box, Alarm Viewer, Browser Check objects.
properties following tables listed they available from Object Inspector. same properties, under similar names, also displayed properties dialog each object.
General Properties
Properties that available some static graphical objects listed below. addition, specific properties described each object.
Property BackColor EnableOperator Input EndGradient Color ForeColor Gradient Description Determines back/fill color object. default value 255.255.255. Determines object accessible operators Runtime mode. default setting True. Determines gradient color BackColor when toning used. default value 0.0.0. Determines color line font. default value 0.0.0. options toning style None (default setting), Left Right, Right Left, Bottom, Bottom Top, Center Edge, Edge Center, Vertical Center Edge (from center edges vertically), Vertical Edge Center (from edges center vertically), Horizontal Center Edge Horizontal Edge Center. Placement object from left edge screen. options line format Solid (default setting), Dash, Dot, Dash Dash Dot. Line point width. default value Determines angle rotation object. default value options rotation point (handles objects) Center (default setting), Left, Center, Right, Center Left, Center Right, Bottom Left, Bottom Center, Bottom Right Custom (free rotation).
Left PenStyle PenWidth RotateAngle RotationCenter Type
RotationCenterX X-coordinate rotation point placement. default value RotationCenterY Y-coordinate rotation point placement. default value SecurityLevel Security level screen/form object Runtime mode. object accessible users value (default setting). information, section Security Manager. options shadow effect objects None (default setting), Left (from edge left), Bottom Right, Bottom Left Right. Color shadow effect. default value 128.128.128. Determines Tab-key used jump between objects Runtime mode. Active when True. default setting False. more information, section Order. Informative text displayed when cursor over object. Placement object from edge screen. default setting, True, makes object visible Runtime mode.
Shadow ShadowColor TabStop
ToolTip Visible
Beijer Electronics MA00600A
Static Graphical Objects
Line
Line tool used create lines. holding down Shift-keys same time object positioned screen, line will snap angles 45degree intervals.
Line Properties
Property (Name) Arrowhead Description Object name your choice. default name Line1. options arrowheads None (default setting), Point (arrowhead second fixed point), Start Point (arrowhead first fixed point) Both. represents start-point, end-point line screen, according drawing below.
End-point (X2,
ArrowheadHeight Size arrowhead, value specified points. default value
Start-point (X1,
also section General Properties.
Rectangle
Rectangle tool used create rectangular objects. holding down Shift-keys same time object positioned screen, rectangle will become quadratic.
Rectangle Properties
Property (Name) BorderStyle Height Description Object name your choice. default name Rectangle1. format options object frame None, Single (default setting), Raised Sunken. Determines object height. default value
Transparent Determines background image will visible through field, within frame. Other objects cannot clicked through transparent surface. default setting False. Width Determines object width.The default value
also section General Properties.
Beijer Electronics MA00600A
Static Graphical Objects
Ellipse
Ellipse tool used create circles circular objects. holding down Shift-keys same time object positioned screen, circle will created.
Ellipse Properties
Property (Name) Height Description Object name your choice. default name Ellipse1. Determines object height. default value
Transparent Determines background image will visible through field, within frame. Other objects cannot clicked through transparent surface. default setting False. Width Determines object width. default value
also section General Properties.
tool used create objects. holding down Shift-keys same time positioned screen, quarter-circle will created.
Properties
Property (Name) Height StartAngle StopAngle Description Object name your choice. default name Arc1. Determines object height. default value Setting angle arc's start-point. default value Setting angle arc's end-point. default value
(-90)
Transparent
Determines background image will visible through field formed imaginary line between end-points. Applicable only Wedge True. Other objects cannot clicked through transparent surface. default setting True. Determines end-points closed against circle's center-point. default setting False (open).
Wedge
Closing against circle's center
Width
Determines object width. default value
also section General Properties.
Beijer Electronics MA00600A
Static Graphical Objects
Polyline
Polyline tool used create polygons. first line drawn clicking dragging. Next, points clicked through which next line will drawn. holding down Shift-keys same time cursor moved onto screen, line will snap angles 45-degree intervals. open close polygon, Layout/Contour. points also added polygon under Layout/Edit point. Right-click finish drawing polygon lines.
Polyline Properties
Property (Name) Height Transparent Description Object name your choice. default name Polyline1. Determines object height. Determines background image shall visible through empty field within figure's lines. Applicable only endpoints closed. Other objects cannot clicked through transparent surface. True Transparent (default setting) False Field filled with color specified ForeColor Determines object width.
Width
also section General Properties.
Freehand
Freehand tool used create freehand figures. resulting figure will have same name functions Polyline object. open close figure, Layout/Contour. points also added figure under Layout/Edit point. Right-click finish drawing freehand figures.
Beijer Electronics MA00600A
Static Graphical Objects
Text
Text tool used create static text. holding down Shift-keys object being placed screen, object will take rectangular form, adapted text. Text from Microsoft Word pasted into this object, complete with tabs, carriage returns, etc. original font, however, retained.
Keyboard shortcut Ctrl Ctrl Enter Inserts character Carriage return Function
Text Properties
Property (Name) Alignment AutoSize BorderStyle Font Height Layout StretchFont Description Object name your choice. default name Text1. options text alignment Left Justify, Right Justify Center (default setting). Determines object adapts space requirements text. default setting False. format options object frame None (default setting), Single, Raised Sunken. Selection font. default font Sans Serif. Determines object height. default value options text placement frame Bottom, Center (default setting) Top. font size adjusts proportionally size change object. default setting True. StretchFont only available AutoSize WordWrap False. Entered static text. default text Text. Text with effect. default value False. Determines background image will visible through field, within frame. Other objects cannot clicked through transparent surface. True Transparent (default setting) False Field filled Determines object width. default value Automatic carriage return AutoSize disabled (False). default setting False.
Text Text3D Transparent
Width WordWrap
also section General Properties.
Beijer Electronics MA00600A
Static Graphical Objects
User-defined grouped objects
number symbols available from Library, some users might interested creating symbols their own. These made dynamic easy steps, described following example. Place ellipse slightly larger ellipse, edit their colors according your preferences from each ellipse's appearance tab.
Select both ellipses clicking them while pressing Shift-key, group them selecting Group/Group from Layout-menu. Select group select Group/Edit group from Layout-menu. window with individual objects group displayed.
Which grouped object that selected displayed screen background. Select upper ellipse, click display ellipse properties dialog. Click Dynamics tab, select BackColor click browse-button next value from field.
Beijer Electronics MA00600A
Static Graphical Objects Select parameter Value under Parent click
Select color value (interval From: click Add. Then select color value (interval From:1 To:1), click once more. Then click close ellipse properties window.
grouped object prepared connected data item. Since smaller ellipse connected Parent.Value parameter, once grouped object connected digital signal, smaller ellipse will affected.
group changes color value changes digital signal connected
Beijer Electronics MA00600A
ActiveX Objects
ActiveX Objects
ActiveX technology based Microsoft standards. Objects created several different environments communicate with another. CEZAR functionality enhanced using ActiveX objects. These objects developed third-party vendors.
Adding ActiveX Objects
ActiveX object placed screen using ActiveX Object Objects Toolbar.
dialog displayed warning risks viruses. warning dialog disabled checking Don't show this dialog again. Next, selection list displayed with ActiveX objects that available your computer (i.e. contents list vary what installed your computer). help file, which opened pressing often included with object. ActiveX objects also placed Objects Toolbar. ActiveX object Object Toolbar, right-click Object Toolbar, choose then select desired object from list.
Settings
Each ActiveX object specific properties. These displayed Object Inspector. properties vary with object constructed, also names various properties differ from existing objects configuration tool.
Beijer Electronics MA00600A
Windows Objects
Windows Objects
Window objects used create check boxes, combo boxes, edit boxes list boxes. properties following table listed they available from Object Inspector. same properties, under similar names, also displayed properties dialog each object.
General Properties
Properties that available some static graphical objects listed below. addition, specific properties described each object.
Property Appearance BackColor DataItem DataSource Enable OperatorInput Font ForeColor Left SecurityLevel Description format options objects Flat (default setting). Determines fill color object. default value varies different objects. Individual value data source, such signal from controller. information, section Controller. Data source where various values retrieved, such controller. information, section Controller. Determines object accessible operator Runtime mode. default setting True. Selection font, font size font format object. default font Sans Serif. Determines font color. default value 0.0.0. Placement object from left edge screen. Security level screen/form object Runtime mode. object accessible users value (default setting). information, section Security Manager. options shadow effect objects None (default setting), Left (from edge left), Bottom Right, Bottom Left Right. Color shadow effect. default value 128.128.128. Determines Tab-key used jump between objects Runtime mode. Active when True (default setting). information, section Order. Informative text displayed when cursor over object. Placement object from edge screen. Value signal. default value default setting, True, makes object visible Runtime mode.
Shadow
ShadowColor TabStop
ToolTip Value Visible
Beijer Electronics MA00600A
Windows Objects
Check
check box, more predefined options selected. These options used activate deactivate digital signals, example.
Check Properties
Property Caption Alignment Description Caption text object. default caption CheckBox. placement options check frame Left Justify (default setting) Right Justify.
also section General Properties.
Combo
combo box, users either choose from several predefined options from attached list box, type their alternative option. There various options that operator choose among under Texts properties dialog. words numbers that will appear list entered Texts field. Each option associated with value that shown field Value, value that specified each proposed option. order options modified using Down buttons. When option combo selected Runtime mode, value will sent specified location data source.
Combo Properties
Property (Name) Height Text Width Description Object name your choice. default name ComboBox1. Determines object height. default value Text options Combo Box. Each option connected value property Value. Determines object width. default value 120.
also section General Properties.
Beijer Electronics MA00600A
Windows Objects
Edit
This object used enter numeric alpha-numeric values into memory register, example.
Edit Properties
Property (Name) Alignment Height Horizontal Scrollbar InputStyle Text Vertical Scrollbar Width Description Object name your choice. default name EditBox1. options text alignment Left Justify (default setting), Right Justify Center. Determines object height. default value Displays horizontal scroll bar. default setting False. options type entry data that object accepts Numeric (numbers only) AlphaNumeric (numbers letters default setting) Entered static text. Displays vertical scroll bar. This option makes possible enter text that wraps over several lines. default setting False. Carriage returns made with Ctrl Enter. Determines object width. default value 120.
also section General Properties.
List
list box, several predefined options selected. there space options list box, scrollbar will automatically appear right. Under Texts properties dialog various options that operator choose among. Texts field, words numbers entered that will appear list box. Each option associated value that shown field Value, value that specified each proposed option. clicking New, option added list. order options modified using Down buttons. When option list selected Runtime mode, value will sent specified location data source.
List Properties
Property (Name) Height Width Description Object name your choice. default name ListBox1. Determines object height. default value 120. Determines object width. default value 120.
also section General Properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Dynamic Graphical Objects
Dynamic graphical objects connected internal external analog digital signals.
General properties
Some tabs properties dialog similar some dynamic graphical objects. These described below. addition, specific properties described each object.
Data Connection
connection controller internal variables made under Data Connection tab.
Select data source; controller internal variables. data item selected list added typing name. Clicking button also possible. also section Adding data items.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Appearance
Settings appearance object made under Appearance tab.
There many possibilities customizing looks various objects.
Note: When selecting Transparent option, objects cannot clicked through transparent surface.
Color
color different object components selected under Color tab.
Each property selected list adjusted according your preferences. Windows System Colors color selected instead standard colors.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Font
font different object components selected under Font tab.
preview selected font properties displayed.
Note: Text option under Appearance affects text properties.
Picture
Some objects enhanced using picture. graphics folder included program installation.
option Picture stretch under General makes picture fill object surface.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Extended
explanatory tooltip, displayed when cursor moved over object Runtime mode, entered under Extended tab.
Tab-key used jump between objects Runtime mode. Tabstob option, selected default, includes current object. also section Order. Also select security level object Runtime mode. object accessible users value (default setting). also section Security Manager. Enable operator input option makes object accessible operator Runtime mode. checked default.
Dynamics
dynamic functions described chapter Dynamics. objects selected action object under Dynamics/Action properties dialog e.g. button. Then, action type SetFocus available, which used facilitate navigation operator.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Analog Numeric
analog numeric object presents sets numeric value internal external analog signal.
Analog Numeric Properties
Property Display format Description options signal display type Binary, Decimal (default setting), Exponent, Hex, Octal String (letters and/or digits). Number decimals displayed.The default value font size adjusts proportionally size change object default setting. Fills with zeros until number characters specified Number characters reached. unchecked default. options text alignment Left, Right, Center (default setting). When Stretch font checked, will overriding selection this property. Check display and/or input value. outside range minimum maximum values, background color changes OverflowColor specified under Color tab. unchecked default.
Number characters Number characters displayed.The default value Number decimals Stretch font Zero fill
Alignment
Check value range
also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Button
This tool creating buttons. buttons maneuvered example, mouse clicks.
Button Properties
Property Text Picture stretch Text layout Text alignment Picture layout Picture alignment Event Description Text displayed button. default text Button. Determines image selected under Picture adapted button's size default setting. Select location text button, horizontally vertically. Select location picture selected under Picture tab, horizontally vertically. When Picture Stretch checked, will overriding selection this property. options button function Momentary (default setting), Toggle, Reset.
pictures selected under Picture tab. When button pressed, image selected PictureDown displayed. also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Multi Symbol
multi symbol object displays different images depending value associated analog digital signal.
symbol, click New. State value range, browse image file each symbol. graphics folder included program installation. Runtime mode, symbol displayed will change depending value connected data item.
Note: option Automatic size under General adjusts size symbol according original image file. This means that size multi symbol object vary depending value connected data item.
also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Multi Text
multi text object displays different texts depending value associated analog digital signal.
text, click New. State text value range. Runtime mode, text displayed will change depending value connected data item. also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Bargraph
bargraph object presents values internal external analog signal form bargraph.
Warning levels bargraph object under WarningZone tab.
Bargraph Properties
Property Caption value value Scale division Scale ticks Scale Description Object caption your choice. default caption Bargraph. Specifies maximum minimum graph values. default values Selection range scale division. default value Selection range scale ticks. default value Checking Automatic will override Scale division Scale ticks preferences, scale divided according value value. Also decide whether show scale ticks numbers. bargraph displayed vertically (default setting) horizontally. Displays indicator highest lowest measured values. options None (default setting), Low, High High.
Orientation Indicator
also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Slider
slider object used analog values maneuvering graphical slider either direction. analog value used internally externally.
Moving slider changes value connected data item.
Slider Properties
Property Caption value value Scale division Scale ticks Frequency Scale Description Object caption your choice. default caption Slider. Specifies maximum minimum slider values. default values Selection range scale division. default value Selection range scale ticks. default value Sets resolution values registered slider. default value Checking Automatic will override Scale division Scale ticks preferences, scale divided according value value. Also decide whether show scale ticks numbers. slider displayed vertically (default setting) horizontally.
Orientation
also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Meter
meter object presents values internal external analog signal form graphical meter.
appearance meter customized many ways.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Meter Properties
Property Header Footer value value Scale division Scale ticks Scale position Indicator style Start angle Stop angle
Description Header text your choice. default header text Meter. Footer text your choice. There default footer text. Specifies maximum minimum meter values. default values Selection range scale division. default value Selection range scale ticks. default value options placement scale numbering Inside (default setting) Outside. options indicator style Arc, Needle (default setting) pictures above. Specifies start- end-point scale, degrees.
(-90)
default angles (start-point) degrees (endpoint). Alarm high value Alarm value thickness Needle style Specifies width arc-formed scale. Permitted values: 0.01 0.4. default value 0.11. options meter needle shape Thin Line, Thick Line, Short Filled Triangle, Short Hollow Triangle, Long Filled Triangle (default setting) Long Hollow Triangle. Upper lower alarm limits. default limits
also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Trend
Several analog values connected trend object. Value changes trends viewed line diagram that provides operator with signal history. possible zoom section trend chart runtime mode drawing rectangle with cursor. Right-click return full view trend chart. Double-clicking trend chart runtime displays trend history, providing that database connection been configured.
trend chart with curves runtime mode. There eleven tabs trend object properties dialog. Tabs specific trend object described below.
arrows upper right navigate among tabs.
Beijer Electronics MA00600A
Dynamic Graphical Objects
Curves
signal values that linked curves trend object specified under Curves tab. Each curve assigned unique name (label) color. Curves added deleted using buttons. settings selected curve made right-hand side. Click Data Connection button connect each curve data item. Each curve connected specific axis.
General
Descriptive header, subheader footer texts entered under General tab. Additionally, whether show grid selected, grid settings made.
Legend
name each curve displayed object using Legend option. location legend determined under Legend tab.
Axes
settings axes made under Axes tab. Y-axes used values, displayed either side trend, both. Y-axes with different value ranges defined, curves connected either axes. X-axis used time. Different time formats selected. Unit parameter used present unit other information above axis.
Database connection
values registered database checking Database connection option. also chapter Databases: General information.
Dynamics
Most properties under Dynamics/Property correspond properties described above. addition, following properties available:
Property MouseZoom ShowInfo TrackCurve MissingDataIndicator Visible Description Allows user zoom using cursor. Displays info about curve. Activates analysis tool. Determines display missing data; vertical dashes, dotted line penwidth solid line. Decides curve visible.
Beijer Electronics MA00600A
Dynamic Graphical Objects When trend object selected action object e.g. button, following action types available.
Action type CheckDatabase GetEndDate GetStartDate SetEndDate SetStartDate SetFocus Zoom Sets focus trend object runtime. Zooms trend according parameters startX, startY, endX endY. trend chart divided into logical units. example below. Zooms towards center trend chart. Zooms step. Pans zoomed area down/to left/to right/up. Only valid trend been zoomed. Sets end/start date trend. Description Checks database. Creates database database exists. Gets end/start date trend.
ZoomIn ZoomOut ZoomPanDown ZoomPanLeft ZoomPanRight ZoomPanUp
this example, upper left part trend chart will zoomed when clicking Button3. also section General properties.
Beijer Electronics MA00600A
Dynamic Graphical Objects
8.10 Picture
picture object displays image. holding down Shift-keys same time object positioned screen, quadratic object will created. image file selected from Picture tab. graphics folder included program installation. Checking Automatic size under General adjusts picture object size selected image file. With default setting Picture stretch, image will fill picture object. also section General properties.
Beijer Electronics MA00600A
Other Objects
Other Objects
Alarm Viewer, Timer Browser objects presented following sections.
Alarm Viewer
object Alarm Viewer used present alarms; Alarm Viewer used each Alarm Server. Alarms acknowledged with acknowledge button ACK. More detailed information alarm displayed pressing information button This information presented screen text document, example. Alarm Viewer include information about alarm group, status alarm, time alarm registered acknowledged etc.
Acknowledge button Information button Search function Sort function
fields buttons that will displayed selected Object Inspector Properties dialog. operator convenience, there buttons search sort functions. Displaying these buttons optional. Alarms alarm groups, maximum number alarms display Alarm Viewer, defined Alarm Server configuration form. section Alarm Server.
Sorting alarms
Sorting alarms configured using SortColumn SortOrderAscending properties under Dynamics using Object Inspector. SortColumn used sort alarms Alarm Viewer depending column. With default setting, alarms sorted; most recent alarm displayed list. sort e.g. group name column, position that column Alarm Viewer (which would Alarm Viewer picture above) stated. numbering columns depends which columns have decided show, their order. property Fields table describing Alarm Viewer Properties. property SortOrderAscending True default, which means that most recent alarm displayed list. Changing setting False sorts alarms descending.
Beijer Electronics MA00600A
Other Objects
Alarm Viewer Properties
Double-click Alarm Viewer display properties window.
Property Show
Description Select which alarms display Alarm Viewer. alarms selected default. alarm conditions described chapter Alarm Server. Selection alarm server object from which alarms will retrieved. default object AlarmServer1. Select order titles columns displayed Alarm Viewer. Check Vis