| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Altera® MAX+PLUS® software easily interacts with third-party tools suc
Top Searches for this datasheetUsing MAX+PLUS Software with Exemplar Logic Leonardo Software Altera® MAX+PLUS® software easily interacts with third-party tools such Exemplar Logic Leonardo software. With MAX+PLUS software, target Altera programmable logic devices (PLDs) using Leonardo software your front-end tool. Altera/Exemplar Logic Leonardo interface lets quickly synthesize implement designs Altera devices, even complete verify multiple design revisions single day. Figure shows flow diagram Altera/Exemplar Logic Leonardo interface PCs. Exemplar Logic 6503 Dumbarton Circle Fremont, 94555 (510) 789-333 http://www.exemplar.com Figure Altera/ Exemplar Logic Leonardo Interface Exemplar Logic Leonardo Software .vhd .edf MAX+PLUS Software .vho .edo .pof .sof This technical brief describes generate EDIF netlist file MAX+PLUS software using Leonardo software version 4.2.1 Flow Guide. complete instructions synthesize simulate design using Leonardo software then import into MAX+PLUS software compilation, should refer MAX+PLUS Altera Commitment Cooperative Engineering Solutions (ACCESSSM) Guidelines, which available Altera Technical Support (AtlasSM) section Altera site http://www.altera.com. guidelines also available HTML format \lit\html\maxkey directory MAX+PLUS CD-ROM (version higher). Using Leonardo Flow Guide Leonardo Flow Guide provides graphical user interface (GUI) that guides through design synthesis implementation. Figure Altera Corporation M-TB-043-01 Using MAX+PLUS Software with Exemplar Logic Leonardo Software Figure Leonardo Software Flow Guide following example procedure shows select Altera target device generate EDIF netlist file. start Flow Guide create project Altera device, click Flow Guide button choose Altera device family from Target Technology drop-down list box. Choose Flow Guide. also select software optimization parameters from Optimize Flow checkbox options. this example procedure, optimization parameters selected. Choose Load Library button. Verify that your selected device appears Technology window Load Library dialog box. Choose Load. Choose Read button. Specify your source files Filename window. source files must read from lowest highest level within design hierarchy. Then, turn Automatic Processing Source Technology option choose Altera. Then choose Read begin source code analysis. must correct coding errors that appear Leonardo software text/command screen before continue flow. These errors highlighted text. Choose Bubble Tristates button choose bubble_tristates move tristates design hierarchy. Choose Optimize button. Verify that your selected target device family selected, desired, turn Effort, Mode, Optimize options. Choose Optimize begin design synthesis. Choose Area Report button. Specify output file Report Filename window choose desired report results. Choose Report. Choose Report Delay button. Specify output file Report Filename window choose desired report delay results. Choose Report. Choose Write button. Specify output file name Filename window. sure select EDIF from Format options. Choose Write. Altera Corporation Using MAX+PLUS Software with Exemplar Logic Leonardo Software Leonardo software creates EDIF netlist file, which import into MAX+PLUS software compilation. Conclusion Altera provides extensive support documentation help successfully interface MAX+PLUS software with third-party design entry tools. technical support, contact Altera Applications (800) 800-EPLD MAX+PLUS ACCESS Guidelines. also e-mail your technical questions Altera sos@altera.com. answers common questions regarding Altera/Exemplar Logic Leonardo interface, search Atlas Solutions Altera site. More Information following documents provide more detailed information: MAX+PLUS ACCESS Guidelines MAX+PLUS Programmable Logic Development System Software Data Sheet Software Support documents available contacting Literature Services (888) 3-ALTERA; also download them from Altera site http://www.altera.com. Innovation Drive Jose, 95134 (408) 544-7000 http://www.altera.com Copyright 1998 Altera Corporation. Altera, ACCESS, Atlas, MAX, MAX+PLUS, MAX+PLUS trademarks and/or service marks Altera Corporation United States other countries. Other brands products trademarks their respective holders. specifications contained herein subject change without notice. Altera assumes responsibility liability arising application information, product, service described herein except expressly agreed writing Altera Corporation. Altera customers advised obtain latest version device specifications before relying published information before placing orders products services. rights reserved. Altera Corporation Other recent searchesTHS4130 - THS4130 THS4130 Datasheet THS4131 - THS4131 THS4131 Datasheet REJ03G0350-0200 - REJ03G0350-0200 REJ03G0350-0200 Datasheet L934ID5V - L934ID5V L934ID5V Datasheet L934GD5V - L934GD5V L934GD5V Datasheet L934YD5V - L934YD5V L934YD5V Datasheet L934SGD5V - L934SGD5V L934SGD5V Datasheet L934SRD5V - L934SRD5V L934SRD5V Datasheet HMC-T2100 - HMC-T2100 HMC-T2100 Datasheet AN-EVALSF2-ICE2A0565Z-2 - AN-EVALSF2-ICE2A0565Z-2 AN-EVALSF2-ICE2A0565Z-2 Datasheet 74VHCT08A - 74VHCT08A 74VHCT08A Datasheet
Privacy Policy | Disclaimer |