REPORT E940698
TEST REPORT
According
55022: 1998+A1: 2000+A2:2003 61000-3-2: 2000 61000-3-3: 1995+A1: 2001 55024: 1998+A1: 2001+A2:2003 61000-4-2: 1995+A1: 1998+A2:2001 61000-4-3: 2002+A1:2002 61000-4-4: 1995+A2: 2001 61000-4-5: 1995+A1: 2001 61000-4-6: 1996+A1: 2001 61000-4-8: 1993+A1: 2001 61000-4-11: 1994+A1: 2001 Name Model Applicant Address Chipi UC232R FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. SCOTLAND ST.,GLASGOW G58QB SCOTLAND U.K.
Test Engineer
MICK CHOU
Reviewed
BARRY
Issued Date:
SEP.
2005
test report shall reproduced except full, without written approval laboratory. report can't used client claim product endorsement Testing Laboratory. This report only equipment which described page
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
TABLE General General Information Place Measurement Test Standards Product Information
CONTENTS
Description Test Conclusion Modification(s) Test Software Used Support Equipment Used 55022 Conducted Disturbance Test Test Limits Test Setup Photos Test Data
55022 Radiated Disturbance Test Test Description Test Setup Test Limits Test Setup photos Test Data 61000-3-2 Harmonic Current Test Test Description Flow-chart determining Conformity
Test Setup Test Limits Test Setup photo Test Data
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-3-3 Voltage Fluctuations Test 10.1 Test Description 10.2 Test Limits 10.3 Test Setup Photo 10.4 Test Data
61000-4-2 Electrostatic Discharge Test 11.1 Test Description 11.2 Test Setup 11.3 Test Limits 11.4 Discharge Test Drawing 11.5 Test Data
61000-4-3 Radio-Frequency Electromagnetic Field Test 12.1 Test Description 12.2 Test Block Diagram 12.3 Test Limits 12.4 Test Setup Photo 61000-4-4 Fast Transient Burst Test 13.1 Test Description 13.2 Test Setup 13.3 Test Limits 13.4 Test Setup Photo 13.5 Test Data 61000-4-5 Surge Immunity Test 14.1 Test Description 14.2 Test Setup 14.3 Test Limits 14.4 Test Setup Photo 14.5 Test Data
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-6 Immunity Conducted Disturbances, Induced Radio-Frequency Fields 15.1 Test Description 15.2 Test Setup 15.3 Test Limits 15.4 Test Setup Photo 15.5 Test Data
61000-4-8 Power Frequency Magnetic Field Immunity Test 16.1 Test Description 16.2 Test Setup 16.3 Test Limits 16.4 Test Setup Photos 61000-4-11 Voltage Dips, Short Interruptions Voltage Variations Immunity Tests 17.1 Test Description 17.2 Test Setup 17.3 Test Limits 17.4 Test Setup Photo 17.5 Test Data
Labelling Requirement, Warning
List Test Instruments Photos
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
General
General Information
Applicant Address FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. SCOTLAND ST.,GLASGOW G58QB SCOTLAND U.K.
Manufacturer Address
FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. SCOTLAND ST.,GLASGOW G58QB SCOTLAND U.K.
Measurement Procedure
EN55022
Measurement Uncertainty uncertainty testing result given below. method uncertainty Calculation provided Testing document QP-T-28-B QP-T-27-B 0.15 1000 Frequency Expanded Uncertainty Confidence Level; (dB) 2.84 (dB)
Place Measurement
TESTING LABORATORY 12-3Fl, 27-1, Lane 169, Kang-Ning Taipei Hsien, Taiwan, 886-2-26922097 886-2-26956236 NVLAP CODE 200097-0 Registration 90868 NEMKO Aut. ELA133 BSMI Aut. SL2-IN-E-11 VCCI Registration C-493/R-477 St., Hsi-Chih,
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Test Standards
Tested compliance with: 55022:1998 Information Technology Equipment Radio disturbance +A1: 2000+A2: 2003 61000-3-2: 2000 characteristics Limits methods measurement Electromagnetic compatibility (EMC) Part 3-2: Limits Limits harmonic current emissions (equipment input Current including phase Electromagnetic compatibility (EMC) Part 3-2: Limits Limitation voltage fluctuations flicker low-voltage supply systems equipment with rated current Information technology equipment Immunity characteristics Limits methods measurement Electromagnetic compatibility (EMC) Part Testing measurement techniques, Section Electrostatic discharge immunity test Basic Publication Electromagnetic compatibility (EMC) Part Testing measurement techniques, Section Radiated, radioFrequency, electromagnetic field immunity test Electromagnetic compatibility (EMC) Part Testing measurement techniques, Section Electrical fast transient Burst immunity test Basic publication Electromagnetic compatibility (EMC) Part Testing measurement techniques, Section Surge immunity test (includes corrigendum: 1995) Electromagnetic compatibility (EMC) Part Testing measurement techniques, Section Immunity conducted disturbances, induced radio-frequency fields Electromagnetic compatibility (EMC) Part Testing measurement techniques, Section Power frequency magnetic field immunity test Basic publication Electromagnetic compatibility (EMC) Part Testing measurement techniques, Section Voltage dips, short interruptions voltage variations immunity tests
61000-3-3: 1995 +A1: 2001 55024:1998 +A1: 2001+A2: 2003 61000-4-2: 1995 +A1: 1998+A2: 2001 61000-4-3: 2002 +A1: 2002 61000-4-4: 1995 +A2: 2001 61000-4-5: 1995 +A1: 2001 61000-4-6: 1996 +A1: 2001 61000-4-8: 1993 +A1: 2001 61000-4-11: 1994 +A1: 2001
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Product Information
Name: Model Type Frequency Crystal/Oscillator(s) Chassis Used Port/Connector(s) Power Rating Condition Chipi UC232R Connector RS-232 Connector from Prototype Sample Production Sample Test Item Receipt Date SEP. SEP. 2005 2005 SEP. 2005 Engineering Sample
Date(s) performance test
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Description Test Conclusion
equipment under test (EUT) Chipi model UC232R. data cable designed application communicating RS232 interface devices. 5Vdc interface required operate EUT. more detail specification about EUT, please refer user's manual. Test method: According major function designed, configuration following steps test: Connect RS232 connector modem. Connect connector port. corresponding peripherals ports were proceed with test. test carried operational condition worst-case test result recorded provided this report. Conducted emission test: system setup with diagnostic software running. power line conducted tests were line neutral conductors power cord results were recorded. effect varying position interface cables been investigated find worst-case configuration that produces maximum emission. frequencies where peak values emission exceeded quasi-peak limit, emissions were also measured with quasi-peak detectors. average detector also measured emission either quasi-peak values were under quasi-peak limit exceeded average limit, peak values were under quasi-peak limit exceeded average limit. Radiated emission test: maximum readings were found varying height antenna then rotating turntable. Both polarization antenna, horizontal vertical, measured. effect varying position interface cables been investigated find configuration that produces maximum emission. highest emissions were also analyzed details operating spectrum analyzer fixed tuned quasi-peak mode determine precise amplitude emissions. addition, following test standards applicable related tests same configuration operational condition during radiated emission test conducted emission test: 61000-3-2, 61000-3-3, 61000-4-2, 61000-4-3, 61000-4-4, 61000-4-5, 61000-4-6, 61000-4-8 61000-4-11.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Modification(s):
Test Software Used
WinEMC TEST program that continuously generates complete line repeating letter software used during test.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Support Equipment Used
Personal Computer Intel Declaration Conformity(DoC) Manufacturer Model Number MS-6728 Power Supply Switching Power Cord Data Cable
2.Keyboard (KBS1 PS/2)
E5XKB5121WTH0110 Manufacturer Model Number 5121W Power Supply +5Vdc from Power Cord Data Cable Shielded Non-detachable,1.6m Back Shell Metal
3.Monitor (MON1 15")
Declaration Conformity(DoC) Manufacturer SAMSUNG Model Number 550S Power Supply Switching Power Cord Non-Shielded, Detachable, 1.8m Data Cable Shielded Non-detachable,1.5m Back Shell Metal
4.Printer (PRN1)
Declaration Conformity(DoC) Manufacturer Hewlett-Packard Model Number C2642E Power Supply Linear, 30Vdc Power Cable Non-Shielded Detachable,1.7m Data Cable Shielded Detachable,1m Back Shell Metal
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
5.Modem (MOD1)
IFAXDM1414 Manufacturer ACEEX Model Number 1414 Power Supply Linear, 9Vac Power Cable Non-Shielded Detachable,1.7m Data Cable Shielded Detachable,1m Back Shell Metal
6.Mouse (MOUS/1 PS/2)
DZL211106 Manufacturer ACER Model Number M-S42 Power Supply +5Vdc from Power Cord Data Cable Shielded Non-detachable,1.8m Back Shell Metal
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
55022 Conducted Disturbance Test
Test Standard Model Result Compliant
55022
UC232R
Conducted Disturbance Test Limits Main Ports
Frequency Rang
Limits dB(uV) Class Class Quasi-peak Average
Quasi-peak
Average
0.15 0.50 0.50
66-56
56-46
Remarks: average limit when quasi-peak detector used, shall deemed meet both limits measurement with average detector unnecessary. lower limit shall apply transition frequency limit decreases linearly with logarithm frequency range 0.15MHz 0.50 MHz.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Conducted Disturbance Test Setup Photos
FRONT VIEW
REAR VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Conducted Disturbance Test Data Main Ports (LISN)
Model Frequency range Detector Temperature Humidity
UC232R 150KHz 30MHz Peak Value
Test Data
1060 1065
LINE NEUTRAL
Note
Level Read Level Probe (LISN) Factor Cable Loss Over Limit Level Limit Line Margin
Page
Page
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
55022 Radiated Disturbance Test
Test
Standard
Model
Result Compliant
55022
UC232R
Radiated Disturbance Test Description
Preliminary measurements were made indoors chamber meter using broadband antennas, broadband amplifier, spectrum analyzer determine frequency producing maximum EME. Appropriate precaution taken ensure that from were maximized investigated. system configuration, clock speed, mode operation video resolution, turntable azimuth with respect antenna were noted each frequency found. spectrum scanned from 1000 using logbicon antenna. Above 1GHz, linearly polarized double ridge horn antenna were used. Final measurements were made outdoors 10-meter test range using biconical, dipole antenna horn antenna. test equipment placed wooden bench situated 1.5x1 meter area adjacent measurement area. Sufficient time EUT, support equipment, test equipment allowed order them warm their normal operating condition. Each frequency found during pre-scan measurements re-examined investigated using Quasi-Peak Adapter. detector function CISPR quasi-peak mode bandwidth receiver 120kHz. half-wave dipole antenna tuned frequency found during preliminary radiated measurements. EUT, support equipment interconnecting cables were re-configured set-up producing maximum emission frequency were placed 0.8-meter high non-metallic meter table. EUT, support equipment, interconnecting cables were re-arranged manipulated maximize each emission. turntable containing system rotated; antenna height varied meters stopped azimuth height producing maximum emission.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Radiated Disturbance Test Setup
(EUT) GROUND PLANE 0.8m TURN TABLE RECEIVER
Equipment Under Test
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Radiated Disturbance Test Limits
Limits radiated disturbance Class measuring distance Frequency Field Strength V/m)
NOTES lower limit shall apply transition frequency. Additional provisions required cases where interference occurs.
Limits radiated disturbance Class measuring distance Frequency Field Strength V/m)
NOTES lower limit shall apply transition frequency. Additional provisions required cases where interference occurs.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Radiated Disturbance Test Setup Photos
FRONT VIEW
REAR VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Radiated Disturbance Test Data
Model UC232R Frequency range 30MHz 1GHz Temperature
Detector Humidity
Quasi-Peak Value
Antenna polarization
HORIZONTAL
Test distance
Over Freq. (MHz) Level Limit (dBuV/m) (dB)
Limit
Read
Antenna Cable Loss (dB)
Preamp Factor (dB) Azimuth angle) Antenna High(m)
Line Level Factor (dBuV/m) (dBuV) (dB)
110.780 131.007 150.131 170.311 209.036 327.780
21.99 20.42 22.24 22.45 20.06 19.93
-8.01 -9.58 -7.76 -7.55 -9.94 -17.07
30.00 30.00 30.00 30.00 30.00 37.00
29.62 26.70 26.04 27.73 28.05 25.03
11.86 13.08 15.40 13.85 10.81 13.30
0.81 0.94 1.10 1.17 1.40 1.79
20.30 20.30 20.30 20.30 20.20 20.19
283.0 195.0 244.0 304.0 274.0 185.0
Note Level Read Level Antenna Factor Cable Loss Preamp Factor Over Limit Level Limit Line
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Model UC232R Frequency range 30MHz 1GHz Temperature
Detector Humidity
Quasi-Peak Value
Antenna polarization
VERTICAL
Test distance
Over Freq. (MHz) Level Limit (dBuV/m) (dB)
Limit
Read
Antenna Cable Loss (dB)
Preamp Factor (dB) Azimuth angle) Antenna High(m)
Line Level Factor (dBuV/m) (dBuV) (dB)
110.744 129.953 149.693 170.329 209.016 327.358
19.51 21.16 20.28 17.53 19.85 21.96
-10.49 -8.84 -9.72 -12.47 -10.15 -15.04
30.00 30.00 30.00 30.00 30.00 37.00
27.14 27.57 24.14 22.81 27.84 27.06
11.86 12.96 15.34 13.85 10.81 13.30
0.81 0.93 1.10 1.17 1.40 1.79
20.30 20.30 20.30 20.30 20.20 20.19
101.0 272.0 312.0 287.0 195.0 147.0
Note Level Read Level Antenna Factor Cable Loss Preamp Factor Over Limit Level Limit Line
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-3-2 Harmonic Current Test
Test standard 61000-3-2 Model UC232R Result Compliant
Harmonic Current Test Description
equipment under test supplied series with shunt(s) current transformer(s) from source having same nominal voltage frequency rated supply voltage frequency equipment under test. Whether equipment operates with automatic mixed manual control measurements shall made under normal load conditions adequate heat discharge under normal operating conditions. User's operation controls automatic programmers shall produce maximum harmonic component each successive harmonic component turn. purpose harmonic current limitation equipment classified follows Class Balanced three-phase equipment; Household appliances excluding equipment identified Class Tools excluding portable tools; Dimmers incandescent lamps; Audio equipment. Equipment specified three other classes shall considered Class equipment. NOTE Equipment that shown have significant effect supply system reclassified future edition standard. Factors taken into account include number use; duration use; simultaneity use; power consumption; harmonic spectrum, including phase. Class Portable tools Portable tools; welding equipment which professional equipment. Class Lighting equipment. Class Equipment having specified power according 6.2.2 less than equal 600W, following types: Personal computers personal computer monitors; Television receivers. NOTE Class limits reserved equipment that, virtue factors listed note shown have pronounced effect public electricity supply system.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Flow-chart determining Conformity
Start here determine Class (Clause
Uses Techniques allowed 6.1? Professional equipment Does conform
Clause
Belongs exceptions Clause annex Test conditions Defined Onwards `generic' conditions 6.2.1
Conform -3-2
Apply those conditions
Relevant limits Professional equipment Does conform 61000-3 Clause
Conforms
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Harmonic Current Test Setup
power supply source measurement equipment equipment under test test voltage
input impedance measurement equipment internal impedance supply source harmonic component order line current open-loop voltage supply source
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Harmonic Current Test Limits
Table Limits Class equipment Harmonic order harmonics 15<=n<=39 Even harmonics 8<=n<=40 1.08 0.43 0.30 0.23 2.30 1.14 0.77 0.40 0.33 0.21 0.15 Maximum permissible harmonic current
Note Class equipment, harmonics input current shall exceed absolute values given table Class equipment, harmonics input current shall exceed values given table multiplied factor 1,5.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Table Limits Class equipment Harmonic order Maximum permissible harmonic current expressed percentage input current fundamental frequency
11<=n<=39 (odd harmonics only) circuit power factor
Note harmonic current limits lighting equipment shall exceed relative limits given table Table Limits Class equipment Harmonic 13<=n<=39 (odd harmonics only) Maximum permissible harmonic current watt mA/W 0.35 3.85 Maximum permissible harmonic current 2.30 1.14 0.77 0.40 0.33 table
Note harmonics input current shall exceed values that derived from table
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Harmonic Current Test Setup Photo
FRONT VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Harmonic Current Test Data
Model Line Voltage Current Real Power Fundamental Line Frequency Device Class Harm. Order Indicated Values -0.086 0.018 0.008 0.006 0.010 0.008 0.005 0.010 0.006 0.005 0.004 0.002 0.006 0.004 0.002 0.003 0.002 0.002 0.002 UC232R Vrms 0.296 59.54 892.8 mArms Harm. Order Indicated Values 0.004 0.000 0.000 0.000 0.000 0.001 0.001 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Max. Permits Harm. Current Ampere 1.08 0.43 0.30 0.23 0.18 0.15 0.13 0.12 0.10 0.09 0.08 0.08 0.07 0.07 0.06 0.06 0.05 0.05 0.05 0.05
Max. Permits Harm. Current Ampere -2.30 1.14 0.77 0.40 0.33 0.21 0.15 0.13 0.12 0.11 0.10 0.09 0.08 0.08 0.07 0.07 0.06 0.06 0.06
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-3-3 Voltage Fluctuations Test
Test
Standard
Model
Result Compliant
61000-3-3
UC232R
10.1 Voltage Fluctuations Test Description
61000-3-3 standards define measurement requirements, power source requirements, line impedance requirements, voltage fluctuation flicker limits assessing electronic electrical equipment's propensity cause voltage disturbances mains. Compliance with these standards ensures that voltage fluctuations interfere with other equipment connected mains cause incandescent lights visibly flicker that causes annoyance health risk human observer. When automatic controls cycle off, they cause frequent changes toehold supply. When fluctuating load branch circuit with other loads, these changes cause voltage fluctuations that affect loads branch. particular, variations voltage amplitude cause changes light output filament lamps branch circuit. Because output filament lamp proportional square applied voltage, changes light intensities significant even small changes voltage.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
10.2 Voltage Fluctuations Test Limits
limits shall applicable voltage fluctuations flicker supply terminals equipment under test. following limits apply: value shall greater than 1.0; value shall greater than 0.65; value d(t) during voltage change shall exceed 3.3% more than relative steady-state voltage change, shall exceed 3.3%; maximum relative voltage change dmax, shall exceed without additional conditions; equipment which switched manually, switched automatically more frequently than twice day, also either delayed restart (the delay being less than tens seconds), manual restart, after power supply interruption.
NOTE cycling frequency will frequency will further limited limit. example: dmax producing rectangular voltage change characteristic twice hour will give about 0.65. equipment which attended whilst (for example: hair dryers, vacuum cleaners, kitchen equipment such mixers, garden equipment such lawn mowers, portable tools such electric drills), switched automatically, intended switched manually, mote than twice day, also either delayed restart (the delay being less than tens seconds) manual restart, after power supply interruption.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
10.3 Voltage Fluctuations Test Setup Photo
FRONT VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
10.4 Voltage Fluctuations Test Data
Model
UC232R
Voltage Real Power Apparent Power
56.79 65.39
Current Peak Current Frequency
0.285 0.501 50.0
Indicated Values Dmax D(t) 0.072 0.072 0.00% 0.00% 0.00% Short-term flicker indicator
Limit 0.65 3.3% 3.3%
Pass(P) Fail
Long-term flicker indicator Relative steady state voltage change Dmax Maximum relative voltage change Voltage change
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-2 Electrostatic Discharge Test
Test
Standard
Model
Result
61000-4-2
UC232R
test results shall classified basis operating conditions functional specifications equipment under test following unless different specifications given product committees product specifications Performance Criterion normal performance within specification limits temporary degradation loss function performance which self-recoverable temporary degradation loss function performance which requires operator intervention system reset
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
11.1 Electrostatic Discharge Test Description
This standard relates equipment, systems, sub-systems peripherals which involved static electricity discharges owing environmental installation conditions. such relative humidity, low-conductivity (artificial-fiber) carpets, vinyl garments, etc., which exist allocations classified standards relevant electrical electronic equipment. test set-up shall consist wooden able, high standing ground reference plane. horizontal coupling plane(HCP), shall placed table. cables shall isolated from coupling plane insulating support thick ground reference plane shall provided floor laboratory. shall metallic sheet 0.25 minimum thickness. minimum size reference plane exact size depending dimensions shall project beyond coupling plant least sides. shall connected protective grounding system. order minimize impact environmental parameters test results, tests shall carried climatic electromagnetic reference conditions. Climatic conditions ambient temperature: relative humidity:
atmospheric pressure: (860 mbar) (1060 mbar). NOTE other values specified product specification. Electromagnetic conditions electromagnetic environment laboratory shall influence test results.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
11.2 Electrostatic Discharge Test Setup
Example test set-up table-top equipment, laboratory tests
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
11.3 Electrostatic Discharge Test Limits
Test levels Contact discharge Level
discharge Level Test voltage Special
Test voltage Special
open level level specified dedicated
equipment specification higher voltages than those shown specified special test equipment needed
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
11.4 Direct Discharge Test Drawing
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Indirect Discharge Test Drawing
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
11.5 Electrostatic Discharge Test Data (Direct Discharge)
Model
UC232R
Test
Item Direct Discharge
Instrument NoiseKen ESS-100L Relative Humidity
Temperature Storage Capacitor
Discharge Resistor
Discharge Rate
Discharge
Contact Discharge
means function correct during test test.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Electrostatic Discharge Test Data (Indirect Discharge)
Model
UC232R
Test
Item Indirect Discharge
Instrument NoiseKen ESS-100L Relative Humidity
Temperature Storage Capacitor
Discharge Resistor
Discharge Rate
Discharge
Contact Discharge
means function correct during test test.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-3 Radio-Frequency Electromagnetic Field Test
Test
Standard
Model
Result
61000-4-3
UC232R
Field Strength
Level 1KHz
Modulation Start
Stop
1000
Power Power
test results shall classified basis operating conditions functional specifications equipment under test following unless different specifications given product committees product specifications Performance Criterion normal performance within specification limits temporary degradation loss function performance which self-recoverable temporary degradation loss function performance which requires operator intervention system reset
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
12.1 Radio-Frequency Electromagnetic Field Test Description
Most electronic equipment some manner, affected electromagnetic radiation. This radiation frequently generated such sources small hand-held radio transceivers that used operating, maintenance security personnel, fixed-station radio television transmitters, vehicle radio transmitters, various industrial electromagnetic sources. addition electromagnetic energy deliberately generated, there also spurious radiation caused devices such welders, thyristors, fluorescent lights, switches operating inductive loads, etc. most part, this interference manifests itself conducted electrical interference and, such, dealt with other parts this standard. Methods employed prevent effects from electromagnetic fields will normally also reduce effects from these sources. electromagnetic environment determined strength electromagnetic field (field strength volts meter). field strength easily measured without sophisticated instrumentation easily calculated classical equations formulae because effect surrounding structures proximity other equipment that will distort and/or reflect electromagnetic waves. testing equipment shall performed configuration close possible installed case. Wiring shall consistent with manufacturer's recommended procedures, equipment shall housing with covers access panels place, unless otherwise stated. equipment designed mounted panel, rack cabinet, shall tested this configuration.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
12.2 Radio-Frequency Electromagnetic Field Test Block Diagram
Field Leveling Signal
Field Monitor
Fiber Optic Cable
Detector Input Source Power Amplifier Input Bulkhead Feedthrough Antenna
Field Probe
Anechoic Chamber
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
12.3 Radio-Frequency Electromagnetic Field Test Limits
Table Test Level
levels Test field strength Special
NOTE open test level. This level given Product specification.
Table gives details field strength unmodulated signal. testing equipment, this signal amplitude modulate with sinewave simulate actual threats.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
12.4 Radio-Frequency Electromagnetic Field Test Setup Photo
FRONT VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-4 Fast Transient Burst Test
Test
standard
Model UC232R
Result
61000-4-4
test results shall classified basis operating conditions functional specifications equipment under test following unless different specifications given product committees product specifications Performance Criterion normal performance within specification limits temporary degradation loss function performance which self-recoverable temporary degradation loss function performance which requires operator intervention system reset
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
13.1 Fast Transient Bursts Test Description
repetitive fast transient test test with bursts consisting number fast transients, coupled into power supply, control signal ports electrical electronic equipment. Significant test short rise time, repetition rate energy transients. test shall carried basis test plan including verification performances defined technical specification. Climatic conditions tests shall carried standard climatic conditions accordance with 68-1: ambient temperature: relative humidity: atmospheric pressure: 86kPa (860 mbar) 106Kpa (1060 mbar) NOTE other values specified product specification. Electromagnetic conditions electromagnetic conditions laboratory shall such guarantee correct operation order influence test results.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
13.2 Fast Transient Burst Test Setup
Couping/decupling sections shall mounted directly reference ground plane. Bonding connections shall short possibke. Lines Decoupling network
Lines/terminals tested Capacitor clamp
Coupling device
lnsulating support
Reference plane
Electrical fast transievt/burst generator
Grounding conection according manufacturer's specification. Length specified test plan.
This length should
Block-diagram electrical fast transient/burst immunity test
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
13.3 Fast Transient Burst Test Limits
Test levels Open-circuit output test voltage repetition rate impulses power supply port, Level Voltage peak
(Input/Output) signal, data control ports Voltage peak 0.25 Special Repetition rate Special
Repetition rate Special
Special
open level. level specified dedicated equipment specification.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
13.4 Fast Transient Burst Test Setup Photo
FRONT VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
13.5 Fast Transient Burst Test Data
MODEL
UC232R
REGULATION
According 61000-4-4
1995+A2: 2001
Spec
TEST RESULT Temperature degree Duration tests Time between test Power second
Relative Humidity Pulse Burst
Power
Voltage Polarity Test Point Mode Result Power Line Signal Line Clamp Test Note
mean function correct during Fail test
test
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-5 Surge Immunity Test
Test
Standard
Model
Result
61000-4-5
UC232R
test results shall classified basis operating conditions functional specifications equipment under test following unless different specifications given product committees product specifications Performance Criterion normal performance within specification limits temporary degradation loss function performance which self-recoverable temporary degradation loss function performance which requires operator intervention system reset
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
14.1 Surge Immunity Test Description
task described laboratory test find reaction under specified operational conditions caused surge voltages from switching lightning effects certain threat levels. following equipment part test set-up equipment under test (EUT); auxiliary equipment (AE); cables specified type lengeh); coupling device (capacitive arrestors); test generator (combination wave generator, 1.2/50 generator); decoupling network/protection devices; additional resistors, surge applied terminals capacitive coupling network. Decoupling networks required order avoid possible adverse effects equipment under test that powered same lines provide sufficient decoupling impedance surge wave that specified wave developed lines under test
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
14.2 Surge Immunity Test Setup
Combination wave generator Decoupling network C=18µF AC(DC) power supply network Earth reference Example test set- capacltive coupling a.c./d.c. kines; line-to-earth coupling (according 7.2) Combination wave generator
Decoupling network AC(DC) power supply network Earth reference
Example test set- capacltive coupling a.c./d.c. kines; line-to-line coupling (according 7.2)
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
14.3 Surge Immunity Test Limits
preferential range test levels given table Table 1-Test levels Open-circuit test voltage Level
Special NOTE open class level specified product specification
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
14.4 Surge Immunity Test Setup Photo
FRONT VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
14.5 Surge Immunity Test Data
MODEL TEST SETUP TEST RESULT Temperature Waveform Times According
UC232R 61000-4-5 (1995+A1: 2001)
Relative Humidity
times each condition
Test rate power
\Phase \Voltage\Mode\Polarity\Result Line Neutral Line Neutral Line Ground Neutral Ground Note
means function correct during test test
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-6 Immunity Conducted Disturbances, Induced Radio-Frequency Fields
Test
Standard
Model
Result
61000-4-6
UC232R
test results shall classified basis operating conditions functional specifications equipment under test following unless different specifications given product committees product specifications Performance Criterion normal performance within specification limits temporary degradation loss function performance which self-recoverable temporary degradation loss function performance which requires operator intervention system reset
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
15.1 Immunity Conducted Disturbances, Induced RadioFrequency Fields Description
shall placed insulating support, above ground reference plane. table-top equipment, ground reference plane placed table (see figure) cables tested, coupling decoupling devices shall inserted. coupling decoupling devices shall placed ground reference plane, making direct contact with about from EUT. cables between coupling decoupling devices shall short possible shall bundled wrapped. height above ground reference plane shall between provided with other earth terminals, they shall, when allowed, connected ground reference plane through coupling decoupling network CDN-M1, (i.e. port CDN-M1 then connected ground reference). provided with keyboard hand-held accessory, then artificial hand shall placed this keyboard wrapped around accessory connected ground reference plane. Auxiliary equipment (AE) required defined operation according specifications product committee, e.g. communication equipment, modem, printer, sensor, etc., well auxiliary equipment necessary ensuring data transfer assessment functions, shall connected through coupling decoupling devices. However, possible number cables tested should limited restricting attention representative functions.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
15.2 Immunity Conducted Disturbances, Induced RadioFrequency Fields Setup
<0.3m
CDN-T2 Balanced pair
telecommunication lines
Mains
CDN-M2 Mains Insulating support Reference ground plane
Unscreened non-balanced cable
CDN-AF2
Test generator
NOTE clearance from metallic obstacles shall least non-excited input ports CDNs shall terminated loads
Example test set-up with single-unit system class safety equipment (see 536)
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
15.3 Immunity Conducted Disturbances, Induced RadioFrequency Fields Test Limits
tests required induced disturbances caused electromagnetic fields coming from intentional transmitters frequency range kHz, open-circuit test levels (e.m.f.) unmodulated disturbing signal, expressed r.m.s., given table test levels port coupling decoupling devices. testing equipment, this signal amplitude modulated with sine wave simulate actual threats.
Table1 Test levels Frequency range 80MHz Level
Voltage level (e.m.t.) [dB( Uo[V] special
open level.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
15.4 Immunity Conducted Disturbances, Induced RadioFrequency Fields Test Setup Photo
FRONT VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
15.5 Immunity Conducted Disturbances, Induced RadioFrequency Fields Test Data
MODEL REGULATION TEST RESULT
UC232R
61000-4-6 (1996+A1: 2001)
Temperature degree Start 0.15 Stop Modulation 1kHz. Output impedance Performance criterion Test Ports Input Output power 0.15 0.15 Input Output Signal lines Control lines Note Frequency(MHz) Range 0.15
Relative Humidity Power 230V (YES Source impedance 1V(rms) Field strength 3V(rms) Field strength
Condition NORMAL NORMAL NORMAL
mean function correct during test. test.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-8 Power Frequency Magnetic Field Immunity Test
Test
Standard
Model
Result
61000-4-8
UC232R
Test instruments HAEFELY&TRENCH magnetic field tester MAG100.1 HAEFELY&TRENCH coil with clamp HAEFELY&TRENCH support with castors height
test results shall classified basis operating conditions functional specifications equipment under test following unless different specifications given product committees product specifications Performance Criterion normal performance within specification limits temporary degradation loss function performance which self-recoverable temporary degradation loss function performance which requires operator intervention system reset
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
16.1 Power Frequency Magnetic Field Immunity Test Description
magnetic fields which equipment subjected influence reliable operation equipment systems. following tests intended demonstrate immunity equipment when subjected power frequency magnetic fields related specific location installation condition equipment (e.g. proximity equipment disturbance source). power frequency magnetic field generated power frequency current conductors more seldom, from other devices (e.q. leakage transformers) proximity equipment. influence nearby conductors, should differentiate between: current under normal operating conditions, which produces steady magnetic field, with comparatively small magnitude; current under fault conditions which produce comparatively high magnetic fields short duration, until protection devices operate milliseconds with fuses, seconds protection relays). test with steady magnetic field apply types equipment intended public industrial voltage distribution networks electrical plants. test with short duration magnetic field related fault conditions, requires test levels that differ from those steady state conditions; highest values apply mainly equipment installed exposed places electrical plants. test field waveform that power frequency. many cases (household areas, sub-stations power plant under normal conditions), magnetic field produced harmonics negligible. However, very special cases like heavy industrial areas (large power convectors, etc.) they occur, will considered future revision this standard.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
16.2 Power Frequency Magnetic Field Immunity Test Setup
power source
MAG100
Vertical magnetic field drawing
power source
MAG100
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
16.3 Power Frequency Magnetic Field Immunity Test Limits
Table 1-Test levels continuous field Level Magnetic field strength special
NOTES open level. This level given product specification. Table Test levels short duration: Level Magnetic field strength n.a.2) n.a.2) n.a.2) 1000 special
NOTES
open level. This level, well duration test, given product specification. "n.a." applicable
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
16.4 Power Frequency Magnetic Field Immunity Test Setup Photos
VERTICAL VIEW
HORIZONTAL VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
61000-4-11 Voltage Dips, Short Interruptions Voltage Variations Immunity Tests
17.1 Voltage Dips,short Interruptions Voltage Variations Immunity Test Description
Electrical electronic equipment affected voltage dips, short interruptions voltage variations Power Supply. Voltage dips short interruptions caused faults network, installations sudden large change load. certain cases, more consecutive dips interruptions occur. Voltage variations caused continuously varying loads connected network. Before starting test given equipment, test plan shall prepared. recommended that test plan shall comprise following items type designation EUT; information possible connections (plugs, terminals, etc.) cables, peripherals; input power port equipment tested; representative operational modes test; performance criteria used defined technical specifications; operational mode(s) equipment; description test set-up. actual operating signal sources available EUT, they simulated. each test degradation performance shall recorded. monitoring equipment should capable displaying status operational mode during after tests. After each group tests full functional check shall performed.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
17.2 Voltage Dips, short Interruptions Voltage Variations Immunity Test Setup
Variable transformer Phase Switch
Power supply Switch Variable transformer Neuteal
Voltmeter oscilloscope
Schematic test lnstrumentation voltage dlps short interrupions using variable transformers seitches
Phase
Controllwe
Power supply
Wave-form generator
Power amplifier
Voltmeter oscilloscope
Neutral
Schematic test instrumentation voltage dips, short interruptions variations using power amplifier
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
17.3 Voltage Dips, short Interruptions Voltage Variations Immunity Test Limits
Preferred test levels durations voltage dips short interruptions Test level Voltage short interruptions 0.5* Duration period)
period, test shall made positive negative polarity, i.e. starting 180o, respectively NOTES more above test levels durations chosen tested voltage dips 100%, generally unnecessary test other levels same durations. However, some cases (safeguard systems electromechanical devices) true. product specification product committee shall give indication applicability this note open duration. This duration given product specification. Utilities Europe have measured dips short interruptions duration between period 3000 periods, duration less than periods most common. duration apply test level
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
17.4 Voltage Dips, short Interruptions Voltage Variations Test Setup Photo
FRONT VIEW
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
17.5 Voltage Dips, short Interruptions Voltage Variations Immunity Test Data
MODEL REGULAR
UC232R 61000-4-11 (1994+A1: 2001) Test Voltage 230Vac Test Level Duration 5000 Performance Criterion
TEST RESULT
Voltage dips
Voltage interruptions
rated voltage equipment.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Labelling Requirement, Warning
vertical size 5mm. mark will placed visible spot outside equipment, cases where that impractical, included packaging and/or documentation.
subdivided into categories denoted class class ITE. Class Class category other which satisfies Class limits Class limits. Such equipment should restricted sale following warning shall included instructions Warning This Class product. domestic environment this product cause radio interference which case user required take adequate measures.
Class Class category apparatus which satisfies class disturbance limits. Class intended primarily domestic environment include: equipment with fixed place use; example, portable equipment powered built-in batteries; telecommunication terminal equipment powered telecommunication network; personal computers auxiliary connected equipment.
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
List Test Instruments
Test Mode Instrument Advantest Spectrum LISN(EUT) Conduction (No.2) Kyoritsu LISN(2nd) Cable Receiver Schaffner Pre-Amp. Model R3261A ESH2-Z5 KNW-242 No.4 ESBI CPA-9232 Serial 91720076 831886/004 8-837-7 845658/003 1012 9161-4051 10095 970+971 953+954 829846/038
Next Cal. Date Cal. Interval
June 2006 Apr. 2006 Feb. 2006 July 2006 Aug. 2006 2006 2006 Feb. 2006 1Year 1Year 1Year 1Year 1Year 1Year 1Year 1Year
Radiation No.3)
SCHWARZBECK 9161 Antenna COM-Power AH-118 Horn Ant. (1GHz~18GHz) Cable
SCHWARZBECK Precision Dipole Ant.
No.2 VHAP
(30MHz~1GHz)
June 2006
3Year
Signal Generator
SMY01
Feb. 2007
2Year
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Test item
Instrument (EMC-PARTNER) Transient Tester (EMC-PARTNER) Test System (EMC-PARTNER) EFT/B Clamp (EMC-PARTNER) Magnetic Field Loop antenna
Model
TRA-2000/N6
Serial
Next Cal. Date Aug. 2006
Cal. Interval 1Year
-4-2 -4-4 -4-5 -4-8 -4-11
TRA1Z03B TAR1Z03B
CNEFT 1000-268 1000-169 102C3117
Aug. 2006 Aug. 2006
1Year 1Year
MF-1000 CIT-10 /102C3117 HAR-1000
Aug. 2006 July 2006
1Year 2Years
-4-6 -3-2 -3-3
CONDUCTED IMMUNITY (EMC-PARTNER) Harmonic/ Flicker (Amplifier Research) Power Amplifier (Amplifier Research) Power Meter (Amplifier Research) Field Monitor (Amplifier Research) Field Probe (Amplifier Research) Direct Coupler (Boonton) Power Sensor (Boonton) Power Sensor
July 2006
2Years
(NO.2)
100W1000M11
25616 25355 25339 31094 31078
2006 2006 2006 2006 2006 2006 2006
2Years 2Years 2Years 2Years 2Years 2Years 2Years
PM2002
FM5510
-4-3
FP5000
DC6080
51011-EMC
31011-EMC
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Photos
MODEL UC232R
Page
Laboratory
12-3Fl, 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, TEL: 886-2-26922097 FAX: 886-2-26956236
REPORT E940698
Page
VERIFICATION
conformity with European Directive
E940698
Document holder: Type equipment: Type designation:
FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. Chipi UC232R
sample equipment been tested CE-marking according Directive, 89/336/EEC. 92/31/EEC 93/68/EEC Standard(s) used showing compliance with essential requirements directive:
Standard(s):
55022: 1998+A1: 2000+A2: 2003 61000-3-2: 2000 61000-3-3:1995+A1: 2001 55024: 1998+A1: 2001+A2:2003 61000-4-2: 1995+A1: 1998+A2:2001 61000-4-3: 2002+ A1:2002 61000-4-4: 1995+A2: 2001 61000-4-5: 1995+A1: 2001 61000-4-6: 1996+A1: 2001 61000-4-8: 1993+A1: 2001 61000-4-11: 1994+A1: 2001 Class
Performance Criterion
referred test report(s) show that product fulfills requirements Directive marking. this basis, together with manufacturer's documented production control, manufacturer European authorized representative) Declaration Conformity verify compliance with Directive. Signed behalf
Testing Laboratory
Date: SEP. 2005
Tsui President
Declaration
following Applicant Equipment Model Report
Conformity
FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. Chipi UC232R E940698
herewith confirmed comply with requirements Council Directive Approximation Laws Member States relating Electromagnetic Compatibility(89/336/EEC) amendments Council Directive 92/31/EEC, 93/68/EEC. evaluation above mentioned Directives, following standards were applied: 55022: 1998+A1 2000+A2 2003 Class 61000-3-2 2000 61000-3-3 1995+A1: 2001 55024 1998+A1 2001+A2 2003 61000-4-2 1995+A1: 1998 +A2: 2001 61000-4-3 2002+A1: 2002 61000-4-4 1995+A2: 2001 61000-4-5 1995+A1: 2001 61000-4-6 1996+A1: 2001 61000-4-8 1993+A1: 2001 61000-4-11 1994+A1: 2001
following manufacturer responsible this declaration: FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. SCOTLAND ST., GLASGOW G58QB SCOTLAND
SEP. 2005 Place Date
Signature responsible Person

Other recent searches


TMP86PM29UG - TMP86PM29UG   TMP86PM29UG Datasheet
PD60130H - PD60130H   PD60130H Datasheet
IR2122 - IR2122   IR2122 Datasheet
LTC4268-1 - LTC4268-1   LTC4268-1 Datasheet
BU506 - BU506   BU506 Datasheet
BU506D - BU506D   BU506D Datasheet
AO4612 - AO4612   AO4612 Datasheet
AO4612L - AO4612L   AO4612L Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive