Ultra-compact Digital Panel Controller Convenient Functions Packe


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



SENSOR CONTROLLERS
Ultra-compact Digital Panel Controller
Convenient Functions Packed Small Body!
PS-18V Power Supply
Analog Input
Input
Marked
Conforming Directive
Ultra-compact
Ultra-compact size D65.5mm. mounted even tight space.
Large display
Though size compact, measurement display uses digit, letter height, 7-segment LEDs.
Flexible scaling
conversion input values different scale simply done operation. Since need convert displayed value eliminated, required information confirmed immediately.
20mA input 50MPa
Displayed value (pressure)
24mm 65.5mm 48mm
Letter height
Conversion
Incorporates useful functions
Changing each threshold level cumbersome
Measurement with master workpiece standard
aAuto-reference function useful!
Auto-reference function original function developed SUNX which, example, there reference pressure change during pressure measurement, change automatically added threshold level. Hence, need change threshold level every time.
Threshold level Reference pressure increase Threshold level shift
aZero-adjust function useful!
Zero-adjust function enables setting standard measured value `0'. Hence, useful error check taking measured master workpiece value standard.
Application Judging object height
Analog fiber sensor
Before reference pressure change
After reference pressure change With auto-reference function auto-reference input before pressure level judgement, when reference pressure changes, threshold levels automatically changed accordingly correct judgment possible.
Product judged Without auto-reference function change reference pressure, even product judged product.
Height judgment easily done using zeroadjust function setting measured values master workpiece `0'.
APPLICATIONS
Thickness distinction Detecting improper lathe chuck tightening
High accuracy eddy current type displacement sensor
Measuring inner diameter rings
collimated beam sensor
Analog fiber sensor
Measuring turbidity water tank turbidity water tank measured analog Super manner.
analog sensor
independent outputs incorporated
independent comparative outputs (OUT have been incorporated. High output comparison operation/ output comparison operation each output. Further, hysteresis each outputs arbitrarily.
`H',
Independent high output comparison operation
Comparative output
Hysteresis Hysteresis
`H',
Independent high output comparison operation
Comparative output
Hysteresis Hysteresis threshold value threshold value
`L',
Independent output comparison operation
Comparative output
Hysteresis Hysteresis threshold value threshold value
threshold value threshold value
Various input ranges
series provided with types input ranges: 20mA, 10V. used with suitable analog sensor.
20mA
price
saves space incorporating various functions extremely small size. Further, priced.
types input ranges available.
Power Supply PS-18V
Analog Input
Input
SENSOR CONTROLLERS
SENSOR CONTROLLERS
ORDER GUIDE
Appearance Input range
20mA
Model CA2-T1 CA2-T2 CA2-T3 CA2-T4 CA2-T5
Output
Input
open-collector transistor
Analog Input
Applicable SUNX sensors
Input range Model 20mA CA2-T1
High accuracy eddy current type displacement sensor GP-A series
CA2-T2
Analog fiber sensor FX-11A
CA2-T3
Analog-output inductive proximity sensor series sensing range
CA2-T4
High accuracy eddy current type displacement sensor GP-A series
CA2-T5
Super analog sensor RS/RT-SAS series
Refer P.140
PS-18V Power Supply
Refer P.804 Laser collimated beam sensor LA-510, LA-511 Infrared displacement sensor DSA-L100
Refer P.608 Differential pressure sensor with analog current output DP-M2A
Refer P.806
Refer P.608 Analog-output inductive proximity sensor series sensing range
Refer P.564 collimated beam sensor LA-300 series
Refer P.805
Applicable models
Refer P.734 Refer P.806 Refer P.576 display digital pressure sensor series
Refer P.696 display anti-corrosive digital pressure sensor DP-Y series
Refer P.724
SPECIFICATIONS
Model Item
Supply voltage Power consumption Input range Analog inputs Input impedance inputs Input method conversion method Sampling rate Zero-adjust input (0-ADJ.) Auto-reference input (A-REF.) Start/hold input 20mA Single input Ripple less 2.8W less
CA2-T1
CA2-T2
CA2-T3
CA2-T4
CA2-T5
Selectable from times/sec., times/sec., times/sec. times/sec. Input condition: Non-voltage contact open-collector transistor input Signal condition: Negative logic, Input time duration 10ms more Signal level: 1.5V less (output current: 10mA less) Supply voltage open Guaranteed zero-adjust input usage: 10,000,000 times less (for zero-adjust back-up setting) High level (supply voltage, open): Start, level (1.5V less): Hold open-collector transistor Maximum sink current: 100mA Applied voltage: less (between comparative output GND) Residual voltage: 1.3V less 100mA sink current) 0.4V less 16mA sink current) DC-12 DC-13 less (when start/hold input used sampling rate times/sec.) Variable from 3,999 digit 7-segment display (letter height: 8mm) Selectable from times/sec., times/sec., times/sec., times/sec., time/sec. time/sec. Selectable span 4,000 Nos. between (0.1% F.S. 9999 9999 displayed. 5°C, 50°C displayed)
Utilization category Response time Hysteresis Display Display refresh rate Display range Display accuracy Temperature characteristics Setting resolution Threshold value setting range Polarity indication Indicators operation operation Auto-reference operation Functions Pollution degree Environmental resistance Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Vibration resistance Shock resistance Back-up memory Material Connecting method Weight Orange
digit)
0.5% F.S. over digit 9999 9999
(lights when displayed value threshold value negative) Lights Blinks when display changed display. Measurement mode: when OUTwhen value comparison conditions whenthreshold valuescale setting function set. Setting mode: Blinks threshold zero scale Measurement mode: Lights when Blinks when display changed threshold value display. Orange Setting mode: Blinks when threshold value comparison conditions when full scale scale setting function set. Green (lights when auto-reference function used) Auto-reference function, zero-adjust function, scale setting function, threshold value setting function, hysteresis setting function, comparative output timer function, start/hold function, memory clear function, power supply ON-delay function etc. (Industrial environment) 55°C condensation), Storage: 70°C
Storage: Emission: EN50081-2, Immunity: EN50082-2 1,500V min. between supply terminals connected together enclosure 100M, more, with 500V megger between supply terminals connected together enclosure 55Hz frequency, 1.5mm amplitude directions hours each 294m/s2 (30G) acceleration directions three times each Non-volatile memory (EEPROM), Guaranteed write operations: 1,000,000 less Enclosure: Polycarbonate Terminal block connection approx.
Power Supply PS-18V
Comparative outputs (OUT
Analog Input
Successive approximation method
Input
SENSOR CONTROLLERS
SENSOR CONTROLLERS
CIRCUIT WIRING DIAGRAMS
Input circuit diagram
ST/HOLD, 0-ADJ./ A-REF.
Terminal
Terminal arrangement
(Note
Input
7.5k Main circuit 2.2k 7.5k 2.2k
ST/HOLD
COM. 0-ADJ./ (0V) HOLD A-REF. Start/hold input Load Comparative output Load Comparative output
Analog Input
0-ADJ./ A-REF. COM. (0V)
Internal circuit
Users' circuit
Signal input Zero-adjust/ auto-reference input Signal input 2-wire type analog sensor (Note
Output circuit diagram
Terminal
Notes: COM. (0V) internally connected GND. Notes: shield wire analog sensor connected, make sure connect (Terminal No.7).
Load Load
PS-18V Power Supply
Main circuit
Non-voltage contact open-collector transistor
100mA max. 100mA max.
1.5V less (output current 10mA less) OFF: Supply voltage, open
Internal circuit
Users' circuit
Symbols Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, output transistor
PRECAUTIONS PROPER
This product safety controller. does possess control functions needed accident prevention safety maintenance. Functional description
Description
Function
A-REF
Measurement mode: Lights when Blinks when display changed operation threshold value display. Setting mode: Blinks when threshold value indicator (Orange) comparison conditions when full scale scale setting function set. Auto-reference operation indicator Lights when auto-reference function used. (Green)
MODE
DIGITAL PANEL CONTROLLER
Function
Mode
Description
When pressed while pressing mode key, sensor changes from measurement mode setting mode. Further, changes mode setting mode. shifts settable digit. changes setting numerical value set. setting shown display. setting selected increment confirmed key. When numerical value set, settable digit blinks. blinking digit incremented pressing increment key. also used directly display input value. changes item setting mode. item conditions confirmed key. also used change threshold value display measurement mode.
Shift
Display (Red)
Measurement mode: Display scaled measured value, input value, threshold value threshold value Setting mode: Display setting menu setting parameters Error: Display error code Lights when displayed value threshold value negative.
Increment
Polarity indicator (Red)
Measurement mode: Lights when Blinks when display changed operation threshold value display. indicator Setting mode: Blinks when threshold value (Orange) comparison conditions when zero scale scale setting function set.
PRECAUTIONS PROPER
Functions glance
Function Details
Using this function, input value range converted arbitrary display range (span 4,000 Nos. 9,999 9,999). within Example: case `beam interrupted width' displayed when using analog sensor series having output Since series outputs analog voltage CA2-T2, which input range used.
display Analog sensor value output voltage
Function
Details
making zero-adjust (0-ADJ.) input 10ms, more, output value forcibly made measurement then done taking input value this instant standard `0'. Zero-adjust function cannot used when autoreference function selected. zero-adjust backup used, input value stored even when power supply switched off. cancel zero-adjust function, zero-adjust setting OFF. this case, standard value will return value before zero-adjust input. ON-delay: makes short duration sensing signal ineffective. OFF-delay: extends output signal fixed time period 99.99 sec.).
Zero-adjust function
Zero scale: 1500 Full scale: 0000
Full beam Full beam interruption reception
Full beam received condition Full beam interrupted condition
1500 0000
Time chart
Sensing condition Sensing sensing ON-delay OFF-delay
Full beam Full beam interruption reception (1V) (5V)
15mm
Threshold value setting function
Using this function, threshold value 9,999 9,999. from displayed threshold value setting mode. set, high output comparison operation obtained, set, output comparison operation obtained. Each comparative output each threshold value independent. Hysteresis Independent high Hysteresis output comparison threshold value threshold value operation
Comparative output
Comparative output timer function
Normal operation
Timer period 99.99 sec. (settable units 0.01 sec.)
This function maintains output display comparative outputs (OUT based input value start/hold (ST/HOLD) input falling edge restores normal operation start/hold input rising edge.
Input value Display value
Independent high output comparison operation Independent output comparison operation
Comparative output
Hysteresis threshold value
Hysteresis
Start/Hold function
threshold value Hysteresis
Start/Hold (ST/HOLD) input
High(OFF) Low(ON)
Comparative output
Hysteresis threshold value
Input signal condition 10ms more (sampling rate times/sec.) 100ms more (sampling rate times/sec.) 200ms more (sampling rate times/sec.) 400ms more (sampling rate times/sec.) Memory clear function This function clears settings returns controller initial setting condition. This function activated pressing while pressing shift sec. more. This function delays commencement measurement time period 9,999 sec.) from instant power supply switched This function selects refresh rate measurement value display from times/sec., times/sec., times/sec., times/sec., time/sec. and, time/sec. does affect comparison operation.
threshold value
Hysteresis setting function
This function enables independent setting hysteresis (difference between points) comparative outputs (OUT range 3,999. This function automatically compensates threshold values according change reference input value. When auto-reference (A-REF.) input made Low, measured value that instant added each threshold value (OUT values) give threshold values.
Initial threshold values threshold values
Power supply ON-delay function Display refresh rate selection function
Auto-reference function
Change reference value
This function selects sampling rate measurement from Sampling rate selection function times/sec., times/sec., times/sec. and, times/sec. Decimal point position This function sets position decimal point. setting function Zero-suppression This function removes unnecessary upper digits. setting function (e.g.): 0460 This function fixes least significant digit display `0'. (least significant digit) merely fixes least significant digit display does fixed display function affect comparison operation. Key-protect function This function makes increment ineffective that conditions changed mistake. [When keyprotect function canceled, increment usable.]
Auto-reference (A-REF.) input
High (OFF) (ON) 10ms more
selected whether auto-reference function used not. Auto-reference operation indicator (green) lights when auto-reference function used. Auto-reference function cannot used when zeroadjust function selected.
Power Supply PS-18V
Analog Input
Scale setting function
Input
SENSOR CONTROLLERS
SENSOR CONTROLLERS
Input
PRECAUTIONS PROPER
Ferrite clamp this product used (European standard Directive) approved product, make sure connect ferrite clamps, with loop, connection cables, shown right figure.
Ferrite clamp
Analog Input
<Recommended ferrite clamp> Manufactured TDK: Noise filter single line ZCAT3035-1330
DIMENSIONS (Unit: CA2Digital panel controller
Panel cut-out dimensions
(40) Terminal block (10)
PS-18V Power Supply
(10)
Note: panel thickness should 4mm.
55.5
operation indicator (Orange) Display (Red) operation indicator (Orange)
MODE
Polarity indicator (Red) Mode Shift
Auto-reference operation indicator (Green) Increment

Other recent searches


TD62502 - TD62502   TD62502 Datasheet
TD62502FNG - TD62502FNG   TD62502FNG Datasheet
TD62503FNG - TD62503FNG   TD62503FNG Datasheet
RN4989 - RN4989   RN4989 Datasheet
PCS3P73Z01AW - PCS3P73Z01AW   PCS3P73Z01AW Datasheet
MC33110 - MC33110   MC33110 Datasheet
HM5117400BS - HM5117400BS   HM5117400BS Datasheet
HM514100CS - HM514100CS   HM514100CS Datasheet
HD74LVC245A - HD74LVC245A   HD74LVC245A Datasheet
AN134 - AN134   AN134 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive