| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
AGASTAT 7000 series Industrial Electropneumatic Timing Relay
Top Searches for this datasheetCatalog 1308242 Issued 3-03 (PDF Rev. 4-05) AGASTAT 7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Series 7000 Timing Relays also manufactured MIL-SPEC requirements, conforming requirements MIL-C-2212F (SHIPS) with exception MILS-901. Consult factory ordering information. Note:7032 types certain models with accessories agency approved. Users should thoroughly review technical data before selecting product part number. recommended that users also seek pertinent approvals files agencies/laboratories review them ensure product meets requirements given application. Design Features Available on-delay, true off-delay, on/off-delay. Timing from seconds minutes, linear increments. Oversize time-calibrated adjustment knobs, serrated with high-resolution markings visible from angles makes timer easy timers. Inherent transient immunity. Standard voltages from 6-550VAC 12-550VDC (special voltages available.) Available 2-pole 4-pole models. Numerous enclosure options: explosion proof, dust tight, watertight, hermetically-sealed, NEMA Auxiliary timed instantaneous switches added greater switching flexibility. Many mounting options: Surface mount, Panel mount, Octal plug-in mounting. Options: quick-connect terminals, dial stops, transient protection module. Easy-to-reach screw terminals, face unit, clearly identified. Modular assembly timing head, coil assembly switchblock individual modules, with switches field-replaceable. On-delay model 7012 (delay pickup) Applying continuous voltage coil (L1-L2) starts time delay lasting preset time. During this period normally closed contacts (3-5 4-6) remain closed. delay period normally closed contacts break normally open contacts (1-5 2-6) make. contacts remain this transferred position until coil deenergized, which time switch instantaneously returns original position. De-energizing coil, either during after delay period, will recycle unit within msec. will then provide full delay period upon re-energization, regardless often coil voltage interrupted before unit been permitted "time-out" full delay setting. Design Construction There three main components Series 7000 Timing Relays: Calibrated Timing Head uses needle valve, recirculates under controlled pressure through variable orifice provide linearly adjustable timing. Patented design provides instant recycling, easy adjustment long service life under severe operating conditions. Precision-Wound Potted Coil module supplies initial motive force with minimum current drain. Total sealing without external leads eliminates moisture problems, gives maximum insulation value. Snap-Action Switch Assembly custom-designed over-center mechanism provides greater contact pressure transfer time positive, flutter action. Standard switches DPDT arrangement, with flexible beryllium copper blades silver-cadmium oxide contacts. Special "timing-duty" design assures positive wiping action, sustained contact pressure greater heat dissipation during long delay periods. Each these subassemblies forms self-contained module which then assembled factory with other afford wide choice operating types, coil voltages, timing ranges. squared design with front terminals rear mounting permits grouping Series 7000 units side-by-side minimum panel space. Auxiliary switches added base unit, without affecting overall width depth. Off-delay model 7022 (delay dropout) Applying voltage coil (for least msec) will instantaneously transfer switch, breaking normally closed contacts (1-5 2-6), making normally open contacts (3-5 4-6). Contacts remain this transferred position long coil energized. time delay begins immediately upon de-energization. delay period switch returns normal position. Re-energizing coil during delay period will immediately return timing mechanism point where will provide full delay period upon subsequent deenergization. switch remains transferred position. increase versatility basic timer models, auxiliary switches added either on-delay off-delay types. They switch additional circuits, provide two-step timing action, furnish electrical interlock sustained coil energization from momentary impulse, depending type selected adjustment. Because their simple attachment adjustment features, they installed factory field, competent mechanic. auxiliary switches SPDT with listings 125, 250, VAC. maximum Code Code auxiliary switches added each relay. switch available with on-delay relays only. switch available with both on-delay off-delay relays. Auxiliary Switch Options On-Delay Instant Transfer (Auxiliary Switch Code maximum relay.) Energizing coil begins time delay transfers auxiliary switch. Main switch transfers after total preset delay. De-energizing coil resets both switches instantly. Auxiliary switch nonadjustable. Two-Step Timing (Auxiliary Switch Code maximum relay.) Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Operation basic operating types available. "On-Delay" models provide delay period energization, which switch transfers load from contacts another. Deenergizing unit during delay period immediately recycles unit, readying another full delay period re-energization. "Off-Delay" models switch transfers load immediately upon energization, delay period does begin until unit deenergized. delay period switch returns original position. Re-energizing unit during delay period immediately resets timing, readying another full delay period de-energization. power required during timing period. addition these basic operating types, "Double-Head" models offer sequential delays pull-in drop-out unit. With addition auxiliary switches basic models provide two-step timing, pulse actuation interlock circuits, added circuit capacity. NOTE: Seismic radiation tested E7000 models available. Consult factory detailed information. Dimensions shown Dimensions inches over (millimeters) unless otherwise specified. 1248 reference purposes only. Catalog 1308242 Issued 3-03 (PDF Rev. 4-05) AGASTAT Auxiliary switch options increase versatility basic timer models, auxiliary switches added either on-delay off-delay types. They switch additional circuits, provide two-step timing action, furnish electrical interlock sustained coil energization from momentary impulse, depending type selected adjustment. Because their simple attachment adjustment features, they installed factory field, competent mechanic. auxiliary switches SPDT with listings 125, 250, VAC. maximum Code Code auxiliary switches added each relay. switch available with on-delay relays only. switch available with both on-delay off-delay relays. Auxiliary Switch Options On-Delay Instant Transfer (Auxiliary Switch Code maximum relay.) Energizing coil begins time delay transfers auxiliary switch. Main switch transfers after total preset delay. De-energizing coil resets both switches instantly. Auxiliary switch nonadjustable. Two-Step Timing (Auxiliary Switch Code maximum relay.) Energizing coil begins time delay. After first delay auxiliary switch transfers. Main switch transfers after total preset delay. De-energizing coil resets both switches instantly. First delay independently adjustable, overall delay. (Recommended maximum seconds.) Auxiliary Switch Options Off-Delay these models same auxiliary switch provides either two-step timing instant transfer action, depending adjustment actuator. Two-Step Timing (Auxiliary Switch Code maximum relay.) Energizing coil transfers main auxiliary switches instantly. De-energizing coil begins time delay. After first delay auxiliary switch transfers. Main switch transfers after total preset delay. First delay independently adjustable, overall delay. (Recommended maximum seconds.) Instant Transfer (Auxiliary Switch Code maximum relay.) Energizing coil transfers main auxiliary switches instantly. De-energizing coil resets auxiliary switch begins time delay. Main switch transfers after total preset delay. Auxiliary switch factory adjusted give instant transfer operation, easily adjusted field provide two-step timing. On-delay, off-delay model 7032 (double head) Double Head model provides delayed switch transfer energization coil, followed delayed resetting upon coil deenergization. Each delay period independently adjustable. circuit designs improvement existing controls using more conventional timers, Double Head unit offers distinct advantages. compact design saves precious panel space, while simplified wiring reduces costly interconnection. On-delay, off-delay model 7032 (double head) With addition extra switch block bottom basic unit, this version Series 7000 offers four pole switch capacity with simultaneous timing two-step timing. two-step operation achieved factory adjustment your specifications. two-step operation, maximum timing ratio between upper lower switches recommended. Once adjusted factory, this ratio remains constant regardless changes dial settings. (Ex: upper switch transfer dial sec., minimum time lower switch should sec.) This Series 7000 unit offers many performance features found basic models voltage ranges, timing switch capacities virtually identical. Four pole models approximately 1-1/4" maximum height basic model, approximately 1/8" depth. They designed vertical operation only. Surge/transient protection option Features Protect electronic control circuits from voltage transients generated timer coil. Fast response rapidly rising back E.M.F. High performance clamping voltage characteristics. recognized, (except varistor coil together). Timer polarity sensitive. Surge/Transient Protection Option protects electronic control circuits from transients surges which generated when timer coil activated. Built with minimum moving parts, unit provides fast response rapidly rising voltage transients. accurate, precision-made device polarity sensitive permits user initiate, delay, sequence program equipment actions over wide range applications under most severe operating conditions. consists specially modified coil case, varistor, varistor cover, terminal extensions washers that normal terminations used. varistor will affect operating characteristics 7000 Timer. varistor bilateral symmetrical voltage current characteristics therefore used place back-to-back zener diodes. This characteristic also means that coil will polarity sensitive. Transient Suppressor Option Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: 1249 Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-05) AGASTAT Timing Specifications (All values shown nominal voltage 25°C unless otherwise specified). Operating Modes: Model 7012/7014: On-delay (delay pick-up). Model 7022/7024: Off-delay (delay drop-out). Model 7032: On-delay, off-delay (double head). Timing Adjustment: Timing simply turning dial desired time value. zone approximately separating high timing ranges A,D,E, instantaneous operation time delay) will occur. other ranges produce infinite time delay when dial this zone. Models 7014 7032 available with letter-calibrated dials only. upper time ranges these models twice values shown. Linear Timing Ranges: Models 7012, Models 7014, Code 7022, 7024 7032 Sec. Sec. Sec. Sec. Sec. Sec. Sec. Sec. Sec. Min. Min. Min. Min. Min. Avail. Cyc. Avail. Sec. Avail. 7012*, 7022, 7024: 7014*: +10% 7032: +15% delays greater than seconds: 7012*, 7022, 7014*, 7024: +10% 7032: +15% first time delay afforded Model 7012 with min.) min.) time ranges Model 7014 with time range will approx. longer than subsequent delays coil temperature rise. Reset Time: msec. (except model 7032) Relay Release Time: msec. on-delay models (7012/7014) Relay Operate Time: msec. off-delay models (7022/7024) Operating Voltage Coil Data (for DPDT) Coil Part 7000 Code Letter 7010 Rated Voltage Operating* Voltage Range 60Hz 102-132 204-264 408-528 468-605 20.5-26.5 10.2-13.2 5.1-6.6 178-229 Dual Voltage Coil (Combines A&B) Special Coils (L1, etc.) 22.4-30.8 38.4-52.8 19.2-26.4 100-137.5 9.6-13.2 48-66 200-275 440-605 12.8-17.6 25.8-35.2 76.8-105.6 4.8-6.6 176-242 Special Coils (X1, etc.) Rated Voltage Operating Voltage Range @50Hz 93.5-121 187-242 Repeat Accuracy: delays seconds less: Minimum operating voltages based vertically mounted 7012 units. 7012 horizontally mounted 7022 vertically horizontally mounted units will operate satisfactorily minimum voltages approximately lower than those listed. units drop approximately rated voltage. units drop approximately rated voltage. units operated intermittent duty cycles voltages above listed maximums (intermittent duty maximum duty cycle minutes "on" time.) Surge/Transient Protection Option Characteristics Timers Only) Coil Voltage Excess De-energization Nominal (DC) Energy Capacity (Joule) Transient Voltage 3.57 Surge Life Applied 100,000 times continuously with interval seconds room temperature. Below VAC: 12A; Above VAC: Temperature Range Operating: -22°F +167°F (-30°C 75°C) Storage: -40°F +167°F (-40°C +75°C) Output/Life Contact Ratings: Contact Capacity Amps (Resistive Load) Contact Min. 100,000 Min. 1,000,000 Voltage Operations Operations 15.0 60Hz 20.0 15.0 60Hz 20.0 15.0 60Hz 12.0 10.0 Amps Resistive, Horsepower, VAC/240VAC (per pole) Amps (per pole) Amps, General Purpose, 600VAC (per pole) Dielectric: Withstands 1500 volts 60Hz between terminals ground. 1,000 volts between non-connected terminals. dielectric specification hermetically sealed models consult factory. Insulation Resistance: Megohms with 500VDC applied. Temperature Range: Operating: -20°F +165°F (-29°C 74°C) Storage: -67°F +165°F (-55°C 74°C) Temperature Variation: Using fixed time delay which measured when ambient temperature 77°F (25°C), maximum observed shift average three consecutive time delays -20% -20°F (-29°C) +20% 165°F (74°C). Mounting/Terminals: Normal mounting basic unit vertical position, from back panel. front mounting bracket also supplied with each basic unit, installation from front panel. units calibrated vertical operation. Basic models (7012, 7022) also horizontally mounted, will adjusted accordingly when Accessory specified your order. Standard screw terminals (8-32 truss head screws supplied) located front unit, with permanent schematic markings. Barrier isolation designed accommodate spade ring tongue terminals, with spacing meet industrial control specifications. basic Series 7000 also panel mounted with addition panelmount that includes necessary hardware faceplate. This offers convenience "out-front" adjustment, with large calibrated dial skirt knob. faceplate knob blend with advanced equipment console designs, while body unit wiring protected behind panel. Other mounting options include plug-in styles special configurations meet unusual installation requirements. Contact factory details. Power Consumption: Approximately watts power rated voltage Approximate Weights: Models 7012, 7022 lbs. ozs. 7014, 7024 lbs. ozs. 7032 lbs. ozs. Weight vary slightly with coil voltage. 108-140 204-264 *Four pole Models: Operational voltage range 110% units; 110% units. next column more coil data. Dimensions shown 1250 reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-05) AGASTAT Outline Dimensions (Dimensions inches). Models 7012, 7022 Models 7014, 7024 Model 7032 Panel mount Option Surge/Transient Protection Option Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: 1251 Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-05) AGASTAT Ordering Information Typical Part Basic Series: 7000 series electropneumatic timing relay Operation: On-delay Off-delay Contact Arrangement: 2PDT form On-delay, off-delay (double head) 4PDT form Coils 28VDC 48VDC 24VDC 125VDC 12VDC 60VDC 250VDC 550VDC 16VDC 32VDC 96VDC 6VDC 220VDC Special coils (X1, etc.) Models 7014 7032 model 7032 specify separate time range code each head. Example: ranges selected. sec. sec. sec. sec. sec. min. min. Explosion-proof Enclosure (note Auxiliary Switch, instant transfer. 7012 only (notes Aux. Switches, instant transfer. Model 7014 Factory Installed Only. (notes Dust-tight Gasketing (notes Octal Plug Adapter. combined only with options l1,l2. (note Dial Stops. Auxiliary Switch, two-step timing (notes Transient/Surge Protection (for coil voltage only). Watertight Enclosure (note Panelmount includes hardware adjustment horizontal operation (note Horizontal calibration, horizontal operation without panelmounting (note Horizontal calibration, with Compensating Spring vertical operation (note Coil Voltage: Coils 120VAC, Hz.; 110VAC, 50Hz. 240VAC, Hz.; 220VAC, 50Hz. 480VAC, 550VAC, 24VAC, 127VAC, 240VAC, 50Hz. 12VAC, Dual voltage (combines Special coils (L1, etc.) Timing Range: Models 7012, 7022 7024 sec. sec. sec. sec. sec. min. min. min. cyc. sec. Options: Single quick-connect terminals (note Double quick-connect terminals (note Plug-in connectors (note Enclosure with bottom knockouts (note Hermetically sealed enclosure, solder (notes Hermetically sealed enclosure, octal (notes Hermetically sealed enclosure, screw terminal block (notes Hermetically sealed enclosure, solder (notes Hermetically sealed enclosure, octal (notes Hermetically sealed enclosure, screw terminal block (notes Tamper-proof Cap, opaque black (Cannot combined with Option Tamper-proof Cap, transparent (Cannot combined with Option Notes: Cannot combined with Options Cannot combined with Options Cannot combined with Options Avail. 4-Pole Models Available with options. Available hermetically sealed units. Sized accommodate Auxiliary Switch available On-Delay, Off-Delay (Double Head) model. Available with letter calibrated dials only. Upper time range twice value shown cycles sec. authorized distributors more likely maintain following items stock immediate delivery. 7012AA 7012AB 7012AC 7012AD 7012AE 7012AF 7012AH 7012AK 7012ACL 7012BC 7012NC 7012PA 7012PB 7012PC 7012PD 7012PF 7012PJ 7012PK 7012PKX 7012PJX 7022AA 7022AB 7022AC 7022AD 7022AE 7022AF 7022AH 7022AI 7022AJ 7022AKT 7022BC 7022BK 7022PA 7022PB 7022PC 7022PK Dimensions shown 1252 reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: Refer inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 4-05) AGASTAT Ordering options only orderd factory installed options (Dimensions, where shown, inches.) Single Quick-Connect Terminals Double Quick-Connect Terminals Plug-In Connectors with Accessory below. Total Enclosure With knockouts bottom connection. 3.16" 3.84" 7.63"H Hermetically Sealed Enclosure Tamper-Proof Cover Explosion proof Enclosure (Meets requirements Class Groups locations). 7.50"W 6.00" 10.38" Auxiliary Switch Auxiliary Switch Dustight Octal Plug Adapter Dial Stops Gasket Gasket Auxiliary Switch Transient/Surge Protection Watertight Enclosure (NEMA-4) 4.75" 4.44" 9.75" Transient Protection Panelmount Mounting hardware included. Accessories (Not available 7032 models) Plug-In Receptacle (Accessory Screw Terminals Catalog 700137. with Option Plug-In Receptacle (Accessory Quick Connect Terminals Catalog 700141. with Option. Ordering options only ordered factory installed options. Dimensions shown reference purposes only. Dimensions inches over (millimeters) unless otherwise specified. Specifications availability subject change. www.tycoelectronics.com Technical support: 1253 Refer inside back cover. Other recent searchesZAD-3H+ - ZAD-3H+ ZAD-3H+ Datasheet SN66268 - SN66268 SN66268 Datasheet Si7172DP - Si7172DP Si7172DP Datasheet SB3417 - SB3417 SB3417 Datasheet PVC6Q200C01B00 - PVC6Q200C01B00 PVC6Q200C01B00 Datasheet FCPL1114-5 - FCPL1114-5 FCPL1114-5 Datasheet AN983 - AN983 AN983 Datasheet 74LVT640 - 74LVT640 74LVT640 Datasheet
Privacy Policy | Disclaimer |