| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Single quad output 4.25 inch package Overvoltage short circuit pr
Top Searches for this datasheetNFS110 SERIES Single quad output 4.25 inch package Overvoltage short circuit protection 110W with 20CFM Adjustable outputs EN55022, EN55011 conducted emissions level VDE, BABT safety approvals mark NFS110 series 110W universal input AC/DC power supply 4.25 inch card. NFS110 series four single three quad output models proven itself highly reliable versatile product wide range communication industrial applications, with very high peak current capability each output drive motor applications. NFS110 provides output power with free convection cooling which boosted 110W with 20CFM air. Standard features include overvoltage short circuit protection. series, with full international safety approval mark, meets conducted emissions EN55022 level NFS110 series designed power data networking, computer, telecom industrial applications such servers, thermal printers, storage devices, vending machines equipment. SPECIFICATION OUTPUT SPECIFICATIONS Voltage adjustability specifications typical nominal input, full load 25°C unless otherwise stated GENERAL SPECIFICATIONS ±3.0% ±3.0% ±0.1% max. ±0.02%/°C 6.25V±0.75V 6.25V±0.75V 15.75V±1.0V 22V±1.5V 33V±2.5V max. 160W Pout min. 110W MTBF, Note Isolation voltage Switching frequency Approvals standards Note Weight Hold-up time 110VAC 110VAC 230VAC 230VAC 110W 110W 35ms 17ms 140ms 100ms typical typical typical typical +5.1V output multi's 5.1V single output single output single output single output outputs units turn-on Efficiency Line regulation Overshoot/undershoot Multiple outputs +5.1V single singles single Input/output Input/chassis Watts output zero load Temperature coefficient outputs Overvoltage protection Multi output 5.1V only 5.1V single single single single Primary power limited 3000VAC 1500VAC 70kHz 250kHz Output power limit VDE0805, EN60950, IEC950 BABT, IEC1010, UL1950 C22.2 Singles Multiple outputs MIL-HDBK-217E 550g (19.4oz) 600g (21.2oz) 125,000 hours Minimum output current derating curve Short circuit protection INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Safety ground leakage current 230VAC 110VAC, 50Hz 230VAC, 50Hz Burst mode operation ENVIRONMENTAL SPECIFICATIONS 264VAC 370VDC 47Hz 440Hz 0.2mA, max. 0.4mA, max. Thermal performance Notes Operating, curve +70°C Non-operating -40°C +85°C +50°C, amb. convection cooled +50°C +70°C, Derate 2W/°C amb. convection cooled +50°C, 110W 20CFM forced +50°C +70°C, Derate 20CFM forced 2.75W/°C Peak, +50°C, 110W max. seconds Non-condensing Operating Non-operating 500Hz 10,000 feet max. 40,000 feet max. 2.4G approx. CHARACTERISTICS Conducted emissions Radiated emissions contact Surge Fast transients Radiated immunity Conducted immunity EN55022, part EN55022, part EN61000-4-2, level EN61000-4-2, level EN61000-4-5, level EN61000-4-4, level EN61000-4-3, level EN61000-4-6, level Level Level criteria criteria criteria criteria criteria criteria Perf. Perf. Perf. Perf. Perf. Perf. Relative humidity Altitude Vibration, Note PAGE POWER AC/DC POWER SUPPLIES 80-110W AC/DC Watt AC/DC universal input switch mode power supplies OUTPUT VOLTAGE +5.1V +12.0V -12.0V -5.0V +5.1V (IA) +24.0V (IB) +12.0V -12.0V +5.1V +15.0V -15.0V -5.0V 5.1V OUTPUT CURRENTS PEAK RIPPLE 50mV TOTAL REGULATION ±2.0% ±3.0% ±3.0% ±3.0% ±2.0% +10/-5.0% ±3.0% ±3.0% ±2.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% MODEL NUMBERS NFS110-7601P 8.0A 4.5A 0.5A 0.5A 8.0A 3.5A 4.5A 0.5A 8.0A 4.0A 0.5A 0.5A 16.0A 7.0A 5.0A 3.5A 20.0A 9.0A 1.5A 1.5A 20.0A 4.5A 9.0A 1.5A 7.5A 1.5A 1.5A 22.0A 9.0A 7.3A 4.5A 10.0A 5.0A 1.0A 1.0A 10.0A 4.5A 5.0A 1.0A 1.0A 1.0A 20.0A 9.0A 7.3A 4.5A 120mV 120mV 50mV 50mV 240mV 120mV 120mV 50mV 150mV 150mV 50mV 50mV 120mV 150mV 240mV TRANSIENT RESPONSE NFS110-7601P NFS110-7602P NFS110-7604P NFS110-7605 NFS110-7612 NFS110-7615 NFS110-7624 (7,8) (7,8) (7,8) (7,8) Notes Convection cooled, maximum. Peak outputs lasting less than seconds with duty cycle less than 10%. Total peak power must exceed 110W. Forced air, 20CFM atmosphere, 110W maximum. Figure peak-to-peak. Output ripple measured across 50MHz bandwidth using inch twisted pair terminated with 47µF capacitor. Total regulation defined static output regulation 25°C, including initial tolerance, line voltage within stated limits output voltages adjusted their factory settings. achieve stated regulation output NFS110-7602P, following load condition must true: where: +5.1V output current, +24V output current +24V output will maintain ±5.0% regulation under following additional condition: Single output models have floating outputs which referenced either positive negative. Higher voltage supplies adjusted over wide output voltage range, long total output power does exceed Watts (natural convection) Watts (forced air). Power fail detect available single output models. Derating curve application specific ambient temperatures >50°C, optimum reliability part heatsink should exceed 90oC semiconductor case temperature should exceed 100oC. Caution: Allow minimum second after disconnecting power when making thermal measurements. Three orthogonal axes, random vibration, minute test each axis. This product only inclusion professional installers within other equipment must operated stand alone product. +5.1V (7.5A 10A) +12V (2.5A -12V (0.5A (0.5A 150mV peak, recovery 100mV peak, 0.5ms recovery 100mV peak, 0.5ms recovery 100mV peak, 0.5ms recovery 150mV peak, recovery 300mV peak, recovery 100mV peak, 0.5ms recovery 100mV peak, 0.5ms recovery 150mV peak, recovery 100mV peak, 0.5ms recovery 100mV peak, 0.5ms recovery 100mV peak, 0.5ms recovery 250mV peak, recovery 360mV peak, recovery 450mV peak, recovery 720mV peak, recovery NFS110-7602P +5.1V (7.5A 10A) +24V (1.5A +12V (2.5A -12V (0.5A NFS110-7604P +5.1V (7.5A 10A) +15V (2.5A -15V (0.5A (0.5A NFS110-7605 NFS110-7612 NFS110-7615 NFS110-7624 +5.1V (10A 20A) +12V (4.5A +15V (3.65A 7.3A) +24V (2.25A 4.5A) International Safety Standard Approvals VDE0805/EN60950/IEC950/IEC1010 File 10401-3336-1049 Licence 2874, 1653 1049 UL1950 File E136005 C22.2 File LR41062C Certificate PS/603175 http://www.artesyn.com PAGE 80-110W AC/DC POWER AC/DC POWER SUPPLIES Watt AC/DC universal input switch mode power supplies (J1) mating connector Molex 09-50-3051 Molex 09-91-0500 mating connector with 2478 equivalent crimp terminals. INPUT OPTIONAL POWER FAIL DETECT TIMING DIAGRAM Power fail detect signal (Note 50msT1200ms will vary with line load T33ms Pout: 110W output open collector which will sink 40mA state. (J2) mating connector Molex 09-50-3131 Molex 09-91-1300 mating connector with 2478 equivalent crimp terminals. 0.475 ±0.010 (12.07) 4.75V OUTPUT HIGH 4.75V 3.5V SIGNAL 0-0.4 1.80 (45.72) 0.050 ±0.020 (1.27) ±0.005 (25.4) 1.55 ±0.005 (39.37) 1.00 DERATING CURVE (See Notes Output Power (Watts) 3.35 ±0.015 (85.09) 6-32 (4PL) 110W FORCED COOLING Voltage Adjust Optional Power Fail Detect Circuit (Key 0.250 ±0.010 (6.35) 0.250 ±0.010 (6.35) 6.50 ±0.005 (165.1) 7.00 ±0.020 (177.8) 4.250 ±0.020 (107.95) 3.750 ±0.005 (95.25) NATURAL CONVECTION COOLING 0.156 DIA. HOLE (4PL) MIN. LOAD REQ. ACHIEVE DESIGN MTBF 10°C 20°C 30°C 40°C 50°C 60°C 70°C DIMENSIONS INCHES (mm) Mechanical notes Metallic non-metallic stand-offs (maximum diameter 5.4mm) used four mounting holes without effecting safety approval. ground mounting hole near allows system grounding through metal stand-off system chassis. heat sink grounded, allows system grounding mechanical connection system chassis. supply must mechanically supported using mounting holes additionally supported heatsink mounting holes. always advisable attach power supply heat sink another thermal dissipator (such chassis finned heatsink etc). resulting decrease heat sink mounted component temperatures will improve power supply lifetime. standard L-bracket cover available mounting which contains screws, connectors necessary mounting hardware. different kits available, details pages Order part number `NFS110 COVER KIT' `NFS110C'. CONNECTIONS +5.1V +5.1V +5.1V Return Return Return Return +12V +12V -12V +5.1V +5.1V +5.1V Return Return Return Return +12V +12V -12V +5.1V +5.1V +5.1V Return Return Return Return +15V +15V -15V Vout Vout Vout Return Return Return Return Vout Vout -7601P Ground Neutral Line -7602P Ground Neutral Line -7604P Ground Neutral Line SINGLES Ground Neutral Line Removed +24V connection. PAGE DS_NFS110_19980401.PDF Data Sheet Artesyn Technologies, 1999 information specifications contained this data sheet believed correct time publication. However, Artesyn Technologies accepts responsibility consequences arising from printing errors inaccuracies. Specifications subject change without notice. rights under patent accompany sale such product(s) information contained herein. http://www.artesyn.com PAGE Other recent searchesRF2713 - RF2713 RF2713 Datasheet PGA-135C-C02 - PGA-135C-C02 PGA-135C-C02 Datasheet NTE853 - NTE853 NTE853 Datasheet LAN89303AM - LAN89303AM LAN89303AM Datasheet CDP68HC05 - CDP68HC05 CDP68HC05 Datasheet BDS19SMD05 - BDS19SMD05 BDS19SMD05 Datasheet ADS-117 - ADS-117 ADS-117 Datasheet
Privacy Policy | Disclaimer |