| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
DC/DC CONVERTERS VOLT INPUT SERIES WATT MODELS OUTPUT S
Top Searches for this datasheet-55°C +125°C operation input Fully isolated Magnetic feedback Fixed frequency typ. Topology Current Mode Flyback transient protection single dual models) Inhibit function Short circuit protection Undervoltage lockout DC/DC CONVERTERS VOLT INPUT SERIES WATT MODELS OUTPUT SINGLES DUALS Size (max.): 0.980 0.805 0.270 inches (24.89 20.45 6.86 Weight: grams max. Screening: Standard, (Class DESCRIPTION With miniature footprint just square inches, Seriesof DC/DC converters delivers watts output power while saving significant board real estate. wide input voltage range accepts varying voltages military, aerospace, space power tightly regulates output voltages protect downstream components. Transient protection volts milliseconds exceeds requirements MIL-STD-704A 5.2, volt single models volt dual model. volt single dual converters will withstand transients volts milliseconds. INHIBIT FUNCTION When open collector logic applied inhibit terminal, converter shuts down lowers output voltage near zero input current Leaving terminal open applying open collector logic high will enable converter. PROTECTION Undervoltage lockout prevents Series converters from operating below approximately input voltage keep system current levels smooth, especially during initialization re-start operations. models include soft-start function prevent large current draw minimize overshoot. converters also provide short circuit protection restricting current. CONVERTER DESIGN Series DC/DC converters incorporate continuous flyback topology with constant switching frequency approximately kHz. Current-mode pulse width modulation (PWM) provides output voltage regulation. Output error voltage magnetically back input side regulate output voltage. Regulation also affected load; refer Electrical Characteristics tables following pages. Dual models regulate negative output with magnetic coupling positive output. total load output providing that other output carries minimum total load. dual models used double output voltage connecting load between positive negative outputs, leaving common unconnected. (ex: MCH2805D used output.) POSITIVE INPUT MIL-STD-461 Interpoint's FMSA-461 filter pass CE03 requirements MIL-STD-461C. CONVENIENT PACKAGING Series converters packaged hermetically sealed, projection-welded metal cases which provide EMI/RFI shielding. 0.47 typical +VIN POSITIVE OUTPUT INHIBIT SHUTDOWN CONTROLLER +VOUT OUTPUT COMMON NEGATIVE OUTPUT DUAL MODELS ONLY INPUT COMMON FIGURE BLOCK DIAGRAM SERIES WATT ABSOLUTE MAXIMUM RATINGS Input Voltage Output Power Capacitive Load Single output models Dual output models Lead Soldering Temperature lead) 300°C Storage Temperature Range (Case) -65°C +150°C DC/DC CONVERTERS INHIBIT Inhibit Open Collector Logic (output disabled) Inhibit current Referenced input common Logic high (output enabled) open collector TYPICAL CHARACTERISTICS Output Voltage Temperature Coefficient ppm/°C typical Input Output Capacitance typical Undervoltage Lockout input typical Current Limit 125% full load typical Isolation megohm minimum Audio Rejection typical Conversion Frequency (kHz) 25°C, min, typ, -55°C +125°C min, typ, Inhibit Voltage (unit enabled) RECOMMENDED OPERATING CONDITIONS Input Voltage Range continuous msec transient single dual models) Case Operating Temperature (Tc) -55°C +125°C full power -55°C +135°C absolute Derating Output Power/Current (Tc) Linearly from 100% 125°C 135°C Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER CONDITIONS OUTPUT VOLTAGE1 25°C -55°C +125°C OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION -55°C +125°C -55°C +125°C FULL LOAD -55°C +125°C FULL -55°C +125°C CONTINUOUS TRANSIENT LOAD -55°C +125°C FULL LOAD -55°C +125°C INHIBITED -55°C +125°C -55°C +125°C 25°C -55°C +125°C POWER DISSIPATION -55°C +125°C RECOVERY --55°C +125°C %-100%- LOAD TRANSIENT -55°C +125°C RECOVERY =-55°C +125°C TRANSIENT -55°C +125°C RECOVERY -55°C +125°C DELAY -55°C +125°C OVERSHOOT -55°C +125°C MCH2805S MCH285R2S MCH2812S MCH2815S 4.95 5.05 5.15 5.25 11.88 12.12 14.85 15.15 4.80 5.20 5.00 5.40 11.52 12.48 14.40 15.60 -400 -500 -400 -500 0.75 0.75 -400 -500 -700 -800 1300 1400 -700 -800 UNITS INPUT VOLTAGE LOAD FULL INPUT CURRENT INPUT RIPPLE CURRENT2 EFFICIENCY LOAD FAULT 1500 1600 STEP LOAD RESPONSE5 STEP LINE RESPONSE5 START-UP -400 -500 0.75 0.75 -900 -1000 -750 1000 -850 0.47 notes following page. DC/DC CONVERTERS DUAL OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT6 OUTPUT POWER OUTPUT RIPPLE VOLTAGE +VOUT SERIES WATT UNITS Electrical Characteristics: 25°C Vin, 100% load, unless otherwise specified. CONDITIONS 25°C -55°C +125°C -55°C +125°C -55°C +125°C -55°C +125°C FULL -55°C +125°C FULL -55°C +125°C CONTINUOUS TRANSIENT LOAD -55°C +125°C FULL LOAD -55°C +125°C INHIBITED -55°C +125°C -55°C +125°C 25°C -55°C +125°C MCH2805D ±4.95 ±5.05 ±4.80 ±5.20 ±150 -300 -400 -250 -300 MCH2812D MCH2815D ±11.88 ±12.12 ±14.85 ±15.15 ±11.52 ±12.48 ±14.40 ±15.60 ±62.5 -600 -700 -500 -600 1100 1200 -600 -700 -500 -600 1300 1400 LINE REGULATION LOAD REGULATION ±VOUT INPUT VOLTAGE LOAD FULL INPUT CURRENT INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT POWER DISSIPATION -55°C +125°C RECOVERY -55°C +125°C STEP LOAD %-100%- LOAD TRANSIENT RESPONSE VOUT -55°C +125°C RECOVERY -55°C +125°C STEP LINE RESPONSE5 VOUT TRANSIENT -55°C +125°C RECOVERY -55°C +125°C START-UP DELAY VDC, VOUT -55°C +125°C OVERSHOOT -55°C +125°C Notes: Specified load. Maximum duration short circuit: 25°C-- seconds, 125°C seconds. Load fault short circuit (<50 mohms). Recovery into resistive full load. Transition Recovery time settle within Vout final value. Max. spec indicates converter's total power, available from either output. Specification applies both Vout. Although minimum load required, load output voltage increase 15%. SERIES WATT DC/DC CONVERTERS Single Output Positive Input Input Common Positive Output Output Common Case Ground connection Inhibit Dual Output Positive Input Input Common Positive Output Output Common Case Ground Negative Output Inhibit Squared corner cover indicate one. page dimensions. FIGURE MODEL NUMBERING Base Model Input Voltage Output Voltage decimal point, Vout) Number Outputs single, dual) Screening (Standard screening designator this position.) NUMBERS STANDARD MICROCIRCUIT DRAWING (SMD) 5962-9569601HXC PROCESS 5962-9569701HXC 5962-9569801HXC 5962-9570201HXC 5962-9570301HXC 5962-9570401HXC SERIES SIMILAR PART MCH2805S/883 MCH285R2S/883 MCH2812S/883 MCH2815S/883 MCH2805D/883 MCH2812D/883 MCH2815D/883 exact specifications product, refer drawing. Call your Interpoint representative status Series releases which process". SMDs downloaded from DC/DC CONVERTERS VOLT EFFICIENCY VOLT EFFICIENCY VOLT EFFICIENCY VOLT VOLT VOLT VOLT SERIES WATT TYPICAL PERFORMANCE CURVES: 25°C, full load, VDC, unless otherwise specified. VOLT VOLT 0.25 OUTPUT POWER 0.75 1.25 1.75 VOLT MODELS 0.25 OUTPUT POWER 1.25 1.75 0.75 VOLT SINGLE MODELS 0.25 OUTPUT POWER 1.25 1.75 0.75 VOLT DUAL MODELS EFFICIENCY LOAD EFFICIENCY LOAD EFFICIENCY LOAD FIGURE FIGURE FIGURE div. ATTENUATION (dB) div. FULL LOAD HALF LOAD div. VOUT HALF LOAD FULL LOAD FREQUENCY (kHz) MCH2815S Representative models 200µs div. MCH2805S 500µs div. MCH2805S LINE TRANSIENT RESPONSE LOAD TRANSIENT RESPONSE AUDIO REJECTION FIGURE FIGURE FIGURE 20V/div. div. div. +VOUT FULL LOAD HALF LOAD -VOUT HALF LOAD FULL LOAD div. 2V/div. +VOUT -VOUT 200µs div. MCH2815D VOUT -VOUT FULL LOAD HALF LOAD +VOUT HALF LOAD FULL LOAD 500µs div. MCH2815D TIME (ms) MCH2805S Representative volt models LINE TRANSIENT RESPONSE LOAD TRANSIENT RESPONSE TURN-ON INTO FULL LOAD FIGURE FIGURE FIGURE SERIES WATT DC/DC CONVERTERS ±VOUT VOLTAGE CHANGE ±VOUT VOLTAGE CHANGE TYPICAL PERFORMANCE CURVES: 25°C, full load, VDC, unless otherwise specified. 20V/div. -VOUT 5V/div. -VOUT +VOUT +VOUT TIME (ms) MCH2815D Also representative MCH2812S MCH2815S OUTPUT LOAD DUAL ISOLATED LOAD LOAD LOAD LOAD TURN-ON INTO FULL LOAD 90/10 70/30 50/50 30/70 10/90 OUTPUT LOAD DUAL ISOLATED LOAD LOAD CROSS REGULATION CROSS REGULATION FIGURE FIGURE FIGURE MAXIMUM POWER SINGLE DUAL SINGLE DUAL DUAL SINGLE TRIP POINT 125% EMISSION LEVEL Vout NOMINAL SAFE OPERATING AREA NARROWBAND INPUT VOLTAGE MODELS FULL LOAD .015 FREQUENCY (MHz) LINE DROPOUT OUTPUT VOLTAGE OUTPUT LOAD FILTERED WITH FMSA FIGURE FIGURE FIGURE DC/DC CONVERTERS case indicates one. CASE BOTTOM VIEW 0.805 Figure (20.45) configurations. SERIES WATT 0.980 (24.89) Materials Header Kovar/Nickel/Gold (Case Kovar/Nickel) Cover Kovar/Nickel Pins Kovar/Nickel/Gold, matched glass seal Case dimensions inches (mm) Tolerance ±0.005 (0.13) three decimal places ±0.01 (0.3) decimal places unless otherwise specified CAUTION Heat from reflow wave soldering damage device. Solder pins individually with heat application exceeding 300°C seconds pin. FIGURE CASE MAXIMUM DIMENSIONS BOTTOM VIEW CASE Series: Screening Standard, Seam Seal Projection Weld 0.697 (17.70 0.018 0.002 dia. (0.46 0.05) 0.097 (2.46) 0.000 0.27 ±0.02 (6.9 ±0.5) 0.270 (6.98) 0.000 0.000 0.270 (6.86) 0.000 0.27 ±0.02 (6.9 ±0.5) Squared corner case indicate one. 0.135 (3.43) 0.235 (5.97) 0.435 (11.05) 0.535 (13.59) FIGURE CASE Note: Although every effort been made render case drawings actual size, variations printing process cause some distortion. Please refer numerical dimensions accuracy. 0.835 (21.21) SERIES WATT TEST DC/DC CONVERTERS ENVIRONMENTAL SCREENING 125°C STANDARD 125°C /883 (Class PRE-CAP INSPECTION Method 2017, 2032 TEMPERATURE CYCLE times) Method 1010, Cond. -65°C 150°C Method 1010, Cond. -55°C 125°C CONSTANT ACCELERATION Method 2001, 3000 Method 2001, BURN-IN Method 1015, hours 125°C hours 125°C case (typical) FINAL ELECTRICAL TEST MIL-PRF-38534, Group Subgroups through -55°C, +25°C, +125°C Subgroups +25°C case HERMETICITY TESTING Fine Leak, Method 1014, Cond. Gross Leak, Method 1014, Cond. Gross Leak, 10-3) FINAL VISUAL INSPECTION Method 2009 Test methods referenced MIL-STD-883 determined MIL-PRF-38534. *883 products built with element evaluated components 100% tested guaranteed over Contact Information: Interpoint Headquarters Phone: 1-800-822-8782 +425-882-3100 Email: power@intp.com www.interpoint.com Interpoint Phone: +44-1252-872266 Email: poweruk@intp.com Interpoint France Phone: +33-134285455 Email: powerfr@intp.com 22422-001-DTS This revision supercedes previous releases. technical information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. Series trademark Interpoint. Copyright 1997 2000 Interpoint. rights reserved. Other recent searchesSN74HC08 - SN74HC08 SN74HC08 Datasheet MVM202P06 - MVM202P06 MVM202P06 Datasheet MHW6222 - MHW6222 MHW6222 Datasheet MF436 - MF436 MF436 Datasheet MBRA210ET3 - MBRA210ET3 MBRA210ET3 Datasheet 74ABT16841A - 74ABT16841A 74ABT16841A Datasheet 74ABTH16841A - 74ABTH16841A 74ABTH16841A Datasheet
Privacy Policy | Disclaimer |