Model self contained, powered signal conditioner bridge type instrumen


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Model Bridgesensor
Model self contained, powered signal conditioner bridge type instrumentation. contains precision instrumentation amplifier with isolated, filtered output highly regulated, noise, adjustable output bridge excitation source. unit completely encapsulated rugged environments.
Complete Strain Gage Bridge Signal Conditioner Isolated Volt Output Bridge Balance with Tare Offset Capability Excitation Supply Capable Driving Four Load Cells Powered Rugged Epoxy Encapsulated Design
Applications
Weighing with Load Cells Frequency Strain Measurements Process Control Pressure Transducers Used With Types Output Sensors
Block Diagram
2401 Stanwell Drive Concord, 94520-4841 (510) 687-4411 (510) 687-3333
http://www.calex.com
CALEX FaxFACTS:
1997
Model Bridgesensor
Specifications
NOTE: Unless otherwise noted, specifications apply after hour warm 25°C ambient. Temperature coefficients apply between 55°C ambient.
Getting Started with Model
Excitation Supply. remote sensing used, connect +Sense +Excitation, terminal connect -Sense -Excitation, terminal These connections must made adjust supply step Apply power Model adjust Excitation supply. Turn SWB-1 "ON" fixed Volts. This will supply 10.2 ±2.5% provide best temperature stability. voltages between Volts, place SWB-1 "OFF" position Excitation Supply with potentiometer SWB-2 either position. Turn power Model "OFF" connect load cell Model Excitation terminals Amplifier Inputs. Turn power 463. Turn SWA-3 "ON". output ZERO) Select expected full scale signal range according table with SWA-4 SWA-5. output from load cell known, both SW-4 SW-5 "ON" 40-50mV range. Select required ZERO output range. SWA-2 "ON" zero Volts SWA-2 "OFF" Volts. Adjust potentiometer Volts. Turn SWA-3 "OFF". Expect output change.
Isolation Input Output Amplifier Gain Adjustment Range Input Output Linearity Temperature Stability Input Noise Input Offset Temperature Coefficient Tare Adjustment Range Bridge Balance Referred Input Temperature Coefficient Input Resistance Differential Common Mode Common Mode Rejection 60Hz Common Mode Input Output Zero Adjust Temperature Coefficient Referred Output Output Voltage Range Current Frequency Resonse, -3dB Response Time Rise Time 0.1% Final Value Bridge Supply Voltage Adjustment Range Temperature Coefficient Fixed Temperature Coefficient Load Current Regulation Load Line Output Noise Bandwidth Input Optional Line Isolation Capacitance Dielectric Withstand Environment Ambient Operating Storage Weight RMS, maximum VAC, ±10V 50/60 100, VAC, ±10% typical 1100 Volts -25°C +55°C -25°C +85°C (510 grams) 3.75" 2.0" 2.87" (9.53 7.62 2000 ±0.005% Full Scale (0.005%/°C) V/°C typical 60pF
-3mV +25mV Equals F.S. 3mV/V cell V/°C typical 1000 megohm
minimum Volts maximum Volts 0.3mV/°C typical Volts maximum pole
Apply load dead weight load cell. Adjust TARE potentiometers same ZERO output Step SWA-1 "OFF" provides bridge output balance -3mV +15mV, "ON" between +15mV +25mV, referred amplifier input. This adjustment does change output bridge. Apply full scale load adjust SPAN (GAIN) potentiometer desired full scale output. Range switches SWA-4 SWA-5 required. Remove full scale load check ZERO output. Adjust FINE TARE potentiometer required. Recheck full scale Step End.
Volts typical 10.2V ±2.5% typical 0.02% maximum
Note:
2401 Stanwell Drive Concord, 94520-4841 (510) 687-4411 (510) 687-3333
http://www.calex.com
CALEX FaxFACTS:
1997
amplifier used without using Excitation Supply, external power supply side must connected -EXCITATION Model 463, inputs must tied -EXCITATION. This provides return path finite amplifier input current.
Model Bridgesensor
Amplifier
amplifier true differential input, drift Instrumentation Amplifier with less than 100pA input current. common mode range Volts with respect EXCITATION supply terminal minimum 90dB rejection common mode voltage. input amplifier excitation supply isolated from line output.
Control Switch
Tare Weight Compensation
Model different zero controls. called OUTPUT zero Volts Volts with SWA-2. other zero control called TARE. SWA-1 allows selection TARE ranges, -3mV 15mV +15mV +25mV. Potentiometers available COARSE FINE TARE adjustments.
SWA-1 SWA-2 SWA-4 SWA-5
Tare Range -3mV Zero Voltage Span Range
Connecting Sensor
amplifier finite input current which must have return path amplifier power supplies. This path automatically provided when Model Bridge Excitation Supply used excite sensor. external supply used, side external supply must connected Model -EXCITATION, Terminal sure that common mode voltage limits observed. This would generally limit external power supply Volts assuming that half voltage would common mode, case when exciting full bridge. When full scale output sensor measured millivolts, millivolts, care must exercised wiring systems. millivolts full scale, each microvolt (10-6 Volts) contributes 0.01% full scale output. Wire connections generate microvolts potential contact potentials. These will also thermoelectric potentials thus vary with temperature differences. wires used connecting Model should same material. intervening connections made such terminal block, terminal block connecting points should have good thermal contact they will always same temperature thus cancel each other.
Mechanical Specifications
Transducer Excitation
bridge excitation supply voltage SWB-1 potentiometer SWB-1 fixed Volts. This will provide best temperature stability. supply adjusted between Volts setting SWB-1 adjusting potentiometer supply will deliver 120mA current voltage setting power four sensors.
Terminal Strip Assignments
Screw Terminal Function Screw Terminal Function
SWB-1
Excitation Voltage Fixed Volts Adjustable
2401 Stanwell Drive Concord, 94520-4841 (510) 687-4411 (510) 687-3333
http://www.calex.com
CALEX FaxFACTS:
-SENSE -EXCITATION +SENSE +EXCITATION
+SIGNAL -SIGNAL OUTPUT COMMON
1997

Other recent searches


X10336 - X10336   X10336 Datasheet
VFJA130 - VFJA130   VFJA130 Datasheet
uPA1453 - uPA1453   uPA1453 Datasheet
TNY266P - TNY266P   TNY266P Datasheet
PDA60 - PDA60   PDA60 Datasheet
L63I - L63I   L63I Datasheet
L63SR - L63SR   L63SR Datasheet
L63G - L63G   L63G Datasheet
L63Y - L63Y   L63Y Datasheet
CY2XP306 - CY2XP306   CY2XP306 Datasheet
AAT1151 - AAT1151   AAT1151 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive